• Title/Summary/Keyword: 국부 오염

Search Result 52, Processing Time 0.017 seconds

Short-term Variability of Carbon Dioxide within and across the Korean Peninsula: Case Study during 1995-1997 (이산화탄소의 단주기적 농도변화 특성)

  • Song, Ki-Bum;Youn, Yong-Hoon;Kim, Ki-Hyun
    • Journal of the Korean earth science society
    • /
    • v.21 no.5
    • /
    • pp.623-634
    • /
    • 2000
  • This study was conducted to analyze the patterns associated with the short-term variability of CO$_2$ concentrations over 24-h scale within and across the Korean Peninsula. In the course of our study, we compared the data sets obtained from Moo-Ahn (MAN) station located in the far western coastal area of Korea with those determined from major background observatory stations around the world from the periods of Aug. 1995 to Dec. 1997. The mean CO$_2$ concentration of the MAN area for the whole study periods, when computed using the daily mean values, was found out to be 374.5${\pm}$6.6 ppm (N=884); seasonal mean values were found out to be 378${\pm}$5.2 (spring: N=181), 372${\pm}$10.2 (summer: N =210), 372${\pm}$7.2 (fall: N=243), and 376${\pm}$5.4 ppm (winter: N=206). When the data from MAN was compared with those of major background stations, the effects of both daily and seasonal components appear to vary distinctively across different stations. Those effects are expected to reflect the mixed effects of various factors which include: seasonal pollution patterns, weather conditions, vegetation, and so forth. Based upon this comparative analysis, we suspect that the MAN area is under the strong influence of anthropogenic source processes relative to all the other stations under consideration. If that is not the case, the existence of enhanced CO$_2$ level may be rather ubiquitous phenomena in Korea. More detailed inspection of CO$_2$ behavior from various respects is strongly desired in the future.

  • PDF

Study on Development of Embedded Source Depth Assessment Method Using Gamma Spectrum Ratio (감마선 스펙트럼 비율을 이용한 매립 선원의 깊이 평가 방법론 개발 연구)

  • Kim, Jun-Ha;Cheong, Jea-Hak;Hong, Sang-Bum;Seo, Bum-Kyung;Lee, Byung Chae
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.1
    • /
    • pp.51-62
    • /
    • 2020
  • This study was conducted to develop a method for depth assessment of embedded sources using gamma-spectrum ratio and for the evaluation of field applicability. To this end, Peak to Compton and Peak to valley ratio changes were evaluated according to 137Cs, 60Co, 152Eu point source depth using HPGe detector and MCNP simulation. The effects of measurement distance of PTV and PTC methods were evaluated. Using the results, the source depth assessment equation using the PTC and PTV methods was derived based on the detection distance of 50 cm. In addition, the sensitivity of detection distance changes was assessed when using PTV and PTC methods, and error increased by 3 to 4 cm when detection distance decreased by 20 cm based on 50 cm. However, it was confirmed that if the detection distance was increased to 100 cm, the effects of detection distance were small. And PTV and PTC methods were compared with the two distance measurement method which evaluates the depth of source by the change of net peak counting rate according to the detection distance. As a result of source depth assessment, the PTV and PTC showed a maximum error of 1.87 cm and the two distance measurement method showed maximum error of 2.69 cm. The results of the experiment confirmed that the accuracy of the PTV and PTC methods was higher than two distance measurement. In addition, Sensitivity evaluation by horizontal position error of source has maximum error of less than 25.59 cm for the two distance measurement method. On the other hand, PTV and PTC method showed high accuracy with maximum error of less than 8.04 cm. In addition, the PTC method has lowest standard deviation for the same time measurement, which is expected to enable rapid measurement.