• Title/Summary/Keyword: 국부부식

Search Result 118, Processing Time 0.025 seconds

Evaluation on Bearing Capacity of End Girder Member with Local Corrosion (지점부 부재의 부식손상에 따른 강거더 단부 지압강도 평가)

  • Ahn, Jin Hee;Lee, Won Hong;Kim, In Tae;Jeong, Young Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.5
    • /
    • pp.74-82
    • /
    • 2017
  • Localized corrosions damages in their structural sections can be occurred affected by installed environment conditions with high temperature as near the coastline and humidity or their poor maintenance situation. In bearing supports of steel bridges, especially, lower web and vertical stiffener in end girder support can be easily corroded because of relatively higher humidity due to the narrow space in the end of girder and the wetted accumulated sediments affected by rain water or antifreezing admixture leaked from expansion joint. It can be related to change in their structural performance. In this study, thus, bearing strength test specimens were fabricated considering corrosion damage in the web and vertical stiffeners and the change in their bearing strengths were experimentally evaluated. From the test results, localized corrosion damage of structural members in the end girder affected the bearing strength of end girder support, especially, localized corrosion damage of the vertical stiffener relatively highly affected their bearing strengths.

A Study on the Degradation of Polymer-Coated Stesl in 0.5M NaCl Solution (0.5M NaCl 용액내에서 일어나는 고분자재료로 피복된 강의 퇴화에 관한 연구)

  • Byeon, Su-Il;Jeong, In-Jo;Mun, Seong-Mo;An, Sang-Ho
    • Korean Journal of Materials Research
    • /
    • v.6 no.10
    • /
    • pp.1025-1033
    • /
    • 1996
  • 본 연구에서는 0.5M NaCI 용액내에서 일어나는 고분자재료로 피복된 강의 퇴화현상을 광학현미경 관찰 및 A.C. impedance spectroscopy를 이용하여 연구하였다. 강의 부식은 고분자재료로 피복된 강의 경우 국부부식(localized corrosion)의 형태로 나타난 반면, 피복되지 않은 강의 경우에는 전면부식(uniform corrosion)의 형태로 진행되었다. 고분자재료로 피복된 강의 부식이 국부적으로 진행되는 것은 피복층내에 존재하는 기공이나 크랙과 같은 결함 등에서 부식이 선택적으로 일어나기 때문으로 사료된다. 피복층의 박리(delamination) 현상은 고분자재료로 피복된 강/구리 갈바닉쌍(galvanic couple)의 경우 구리표면 위의 피복층에서만 관찰되었다. 이는 캐소드(cathode)로 작용하는 구리의표면에서 산소의 환원반응에 의해서 형성된 수산화이온(OH-)이 피복층의 박리를 조장하고 있음을 보여준다. 또한, 고분자재료 피복층의 파손 현상은 고분자재료/강의계면에서 석출된 부식생성물에 의해서 크게 조장되고 있음을 알 수 있다.

  • PDF

Measurement of Localized Corrosion Resistance in Additively Manufactured Ti-6Al-4V Alloys Using Electrochemical Critical Localized Corrosion Temperature (E-CLCT) versus Electrochemical Critical Localized Corrosion Potential (E-CLCP) (적층가공 (3D 프린팅) Ti-6Al-4V합금의 국부부식 저항성 평가를 위한 임계국부부식온도와 임계국부부식전위 측정방법의 비교)

  • Seo, Dong-Il;Lee, Jae-Bong
    • Corrosion Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.37-43
    • /
    • 2021
  • Additively manufactured (AM) Ti-6Al-4V alloys exhibit a dominant acicular martensite phase (α'), which is characterized by an unstable energy state and highly localized corrosion susceptibility. Electrochemical critical localized corrosion temperature (E-CLCT, ISO 22910: 2020) and electrochemical critical localized corrosion potential (E-CLCP, ISO AWI 4631: 2021) were measured to analyze the localized corrosion resistance of the AM Ti-6Al-4V alloy. Although E-CLCP was measured under mild corrosive conditions such as human body, the validity of evaluating localized corrosion resistance of AM titanium alloys was demonstrated by comparison with E-CLCT. However, the mechanisms of resistance to localized corrosion on the as-received and heat-treated AM Ti-6Al-4V alloys under E-CLCT and E-CLCP differ at various temperatures because of differences in properties under localized corrosion and repassivation. The E-CLCT is mainly measured for initiation of localized corrosion on the AM titanium alloys based on temperature, whereas the E-CLCP yields repassivation potential of re-generated passive films of AM titanium alloys after breaking down.

Corrosion of Steel Bars in Concrete at Joints under Tidal Environment (조수간만대 환경의 콘크리트 조인트에서 철근의 부식)

  • Lee, Joon-Gu;Park, Kwang-Su;Kim, Myung-Won;Kim, Kwan-Ho
    • Magazine of the Korea Concrete Institute
    • /
    • v.18 no.5 s.94
    • /
    • pp.73-82
    • /
    • 2006
  • 다양한 조인트를 갖도록 제작된 콘크리트 실험체내 철근의 부식에 대한 상세한 조사가 이루어졌다. 실험체들은 25년 동안 조수간만대에 노출되었다. 몇몇 실험체들은 25년 후에 가속챔버내에서 보다 가혹한 열화환경에 노출되었다. 실험항목은 부착강도, 중성화깊이, 염분농도, 부식의 전기화학적, 물리적 측정, 그리고 조인트부 생성물이다. 에폭시나 라텍스 페이스트로 처리된 조인트면을 제외하고 조인트면에 자동생성되는 생성물은 콘크리트 내 철근의 부식을 막는다. 철근과 콘크리트 계면에서의 공극은 국부부식의 주원인이다. 조인트 표면의 레이탄스 제거가 조인트면의 중성화 깊이를 줄인다. 레이턴스 제거 후 모르타르 코팅처리가 라텍스 페이스트나 에폭시코팅처리에 비해 가장 작은 중성화 깊이를 보인다. 레이턴스 제거후 에폭시코팅처리는 가장 강한 부착력을 갖지만 절점부 콘크리트 내 철근부식 방지에는 가장 우수한 성능을 보이지 못한다.

A Study on the Ultimate Compressive Strength of Ship Plate with Local Corrosion (국부이상부식을 가진 선체판의 압괴강도에 관한 연구)

  • 고재용;남정길
    • Journal of the Korean Institute of Navigation
    • /
    • v.22 no.3
    • /
    • pp.65-72
    • /
    • 1998
  • The use of high tensile steel plates is increasing in the fabrication of ship and offshore structures. In usual, plate element contributes to inplane stiffness against the action of inplane load. If the plate element has local corrosion, its load carrying capacity under inplane load is expected to be reduced. Until now, however, the research report concerned with this topic has not seen. In this study, a basic study which clarifies the influence of local corrosion on the ultimate collapse strength of plate element subjected to axial compression is carried out by using elasto-platic large deformation finite element analysis. In particular, influence of corrosive area, corrosive thickness and slenderness ratio of dented plate is investigated.

  • PDF

An Evaluation on the Mechanical Performance of a Corroded Rebar as the Corrosion Pattern of Rebar in Concrete (콘크리트중에서의 철근부식형태에 따른 부식철근의 역학적 특성에 관한 연구)

  • Kim, Hyung-Rae
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.393-396
    • /
    • 2008
  • The purpose of this paper is to find out quantitatively the relationship between the surface shape and the mechanical properties of corroded reinforcement. Three-dimensional measurements were carried out on the surface shape of variously corroded reinforcements and parameters expressing the characteristics of the shape, which included the maximum decrement of sectional area of reinforcement, its distribution along the axis. It was investigated that which parameters could correspond to the mechanical properties of corroded reinforcement and it was confirmed that the maximum decrement of sectional area of reinforcement could express the mechanical properties most appropriately. Finally, this paper proposes a constitutive model of corroded reinforcement for analyzing the structural behavior of reinforced concrete structures considering the localized corrosion of by finite element method.

  • PDF

Characteristics of Thin Film Electric Resistance Probe Prepared at Various Sputtering Condition (박막형 전기저항식 부식속도 측정 센서의 금속층 증착조건에 따른 전기화학적 특성 변화)

  • 방일환;원덕수;송홍석;장상엽;이성민;고영태;김지영
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1998.05a
    • /
    • pp.95-95
    • /
    • 1998
  • 현장에서 부식속도를 측정하는 방법의 하나인 전기저항 프로브(Electric Resistance Probe, ER probe)는 시편이 부식되는 양에 비례하여 저항이 증가하는 원리를 이용한 것으로 부식기구에 무관하게 직접적인 부식속도의 측정이 가능하다. 그러나, 와이어나 판형으로 기계 가공된 프로브로 제작되어 미량의 부식에는 저항변화폭이 작아 긴 측 정시간이 필요하고, 특히 국부 부식의 경우 부식이 상당히 진행되더라도 전체 저항변 화가 크지 않은 문제점이 있다. 박막형 전기저항프로브는 미량의 부식에서도 저항변화폭이 크게 나타나도록하기 위 하여 금속 박막을 스퍼터링으로 증착하여 동일 부식량에서 저항 변화율을 크게 향상 시킨 프로브이다. 이 프로브는 좁은 선폭(O.25-1mm)의 세선을 복수개 포함한 형상으로 프로브를 설계하여 핏팅이 발생하면 하나의 세선이 끊어지도록 하여 국부적인 부식이 일어날 경우에도 저항변화가 크게 나타나도록 고안되었다. 탄소강의 경우 일반적인 환경에서는 부식속도가 결정립의 크기, 가공경화의 정도등 에 민감하게 변화되지 않는 것으로 알려져 있으나, 박막으로 증착되었을 경우에는 별 크재료와는 전혀 다른 미세구조를 가지므로 벌크의 부식거동과는 다른 거동을 보일 수 있다. 이 연구에서는 증착조건을 달리하여 증착된 철 박막의 결정성, 비저항, 표면 상태, 조성등을 4 point 프로브, SEM, Auger spectroscopy등을 이용하여 조사하고 각각의 전위, 부식속도등과의 상관관계를 조사하였다. 증착된 박막의 비저항은 증착중 혼입된 산소의 양에 따라 매우 민감하게 변화하였다. 산소가 l0at%이상 함유된 철은 강의 알려진 비저항보다 수십배 높은 비저항을 보이며, 부식전위가 높아지고 실제 부식속도 또한 매우 낮게 나타났다. 박막의 부식거동은 미량 불순물에 의해서도 크게 변화하였는데 동일한 수준의 비저 항을 갖는 철 박막에서도 99.9% 순도의 철을 타켓으로 하여 증착된 막은 일반 저탄소 강을 타켓으로 하여 증착된 막보다 훨씬 낮은 부식속도를 보였다.

  • PDF

고리 1호기 증기발생기 전열관의 2차측 응력부식균열 Part I: 손상원인 분석

  • 박인규;황일순;황세기;이상학;이계용;김봉수;홍연완
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.211-216
    • /
    • 1995
  • 1994년 11월에 나타난 고리 1호기 증기발생기의 전열관 누설에 대한 원인을 조사하기 위하여 인출 전열관의 파손 분석과 슬러지 분석 및 pH 분석 등을 수행하였다. 손상원인은 국부적인 염기도 상승과 부식전위 상승에 따른 2차측 응력부식균열(ODSCC)로 밝혀졌다. 전열관 표면과 접한 관판 상부의 퇴적슬러지 끝단에 형성된 틈새에서 나타나는 비등현상으로 $Na^{+}$ 등의 양이온이 농축하게 되며, Cl$^{-}$ 등의 음이온 증발로 인하여 국부적으로 염기도의 상승현상이 야기되었다. 또한 재 가동시 전열관 표면에 침착된 잔류 구리와 용존산소의 결합으로 부식전위가 상승되었다. 이와 같은 ODSCC 발생환경은 1990년이래 지속적으로 형성된 것으로 판단된다.

  • PDF

Evaluation of Corrosivity of Antifreeze for Automobiles Containing Non-amine Type Corrosion Inhibitors for Copper (Non-amine계 부식방지제를 포함하는 자동차용 부동액의 구리 부식성 평가)

  • Soh, Soon-Young;Chun, Yong-Jin;Park, In-Ha;Han, Sang-Mi;Jang, Hee-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.619-626
    • /
    • 2020
  • The development of new antifreeze mixtures containing non-amine-type corrosion inhibitors, which considers environmental protection, has become a major issue. In this study, four non-amine-type corrosion inhibitors were synthesized and used to produce five kinds of new antifreeze for automobiles to evaluate the rate of copper corrosion. The effects were evaluated by the weight change, surface observation, roughness measurement, and measurement of copper elution in the solution. The amount of copper eluted measured by ICP from Sample 4 was small, and the elution rate was prolonged. Sample 4 showed the best anti-corrosion performance owing to a corrosion suppression effect by passivating copper because the metal surface was smooth after the test, and the corrosion product layer was formed evenly on the surface as small local corrosion was observed. The major corrosion inhibitor added to Sample 4 was 1-aminomethyl(N',N'-di(2-hydroxyethyl)benzotrazole, which contained a certain amount in Sample 5 to show relatively high local corrosion but passivation in progress. Therefore, among the four corrosion inhibitors, 1-aminomethyl(N',N'-di(2-hydroxyethyl)benzotrazole had the highest corrosion inhibitory effect. This corrosion inhibitor prevents corrosion by promoting the passivation of copper on the antifreeze.