• Title/Summary/Keyword: 구 유동

Search Result 751, Processing Time 0.023 seconds

A study on the flow characteristics in a MILD combustion waste incinerator with the change of flue gas recirculation inlet location (MILD 연소 폐기물 소각로에서 배기가스 재순환 흡입구 위치에 따른 유동 특성 연구)

  • Ha, Ji Soo;Shim, Sung Hun;Jung, Eung Ho
    • Journal of Energy Engineering
    • /
    • v.23 no.3
    • /
    • pp.51-57
    • /
    • 2014
  • A MILD(Moderate and Intense Low oxygen Dilution) combustion, which is effective in the reduction of NOx, is considerably affected by the recirculation flow position of hot exhaust gas to the combustion furnace. A numerical analysis was accomplished to elucidate the flow characteristics in the MILD combustion incinerator for several cases with or without exhaust gas recirculation. It could be seen from the result of the present numerical study that the flow recirculation could be observed in the upper region over the vertical dividing wall for the case without exhaust gas recirculation. The optimal position of exhaust gas recirculation position was derived by the comparison of %RMS of x directional velocity for the cases with exhaust gas recirculation. The case with the exhaust gas recirculation position at the upper right of free board was the most effective with the smallest value of 57.4% RMS.

A Unified 3D Numerical Analysis of a Model Scramjet Engine with a Cavity Flame-Holder and Two Intake Side Walls (공동형 보염기를 갖는 모델 스크램제트 엔진의 흡입구 측면효과를 고려한 3차원 통합 유동해석)

  • Yeom, Hyo-Won;Kim, Sung-Jin;Sung, Hong-Gye;Kang, Sang-Hoon;Yang, Soo-Suk
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.590-593
    • /
    • 2009
  • To identify the detailed 3D flow characteristics of a model scramjet engine, a unified 3D numerical analysis was performed. The numerical domain of concern includes the entire flow path of the model scramjet engine extending from the intake to the nozzle exhaust. Turbulent models($k-{\omega}$ SST and low Reynolds number k-e with Sarkar model) were applied with comparison of experiment result. Intake side wall's effect on flow characteristics was analyzed in view points of flow quality at inlet duct and near the flame holder as well. The code is paralleled with multi-block feature using MPI(Massage Passing Interface) library to speed up the 3D calculation.

  • PDF

A Comparative Study on the Effects of Location Factors on Sales by Restaurant Type (입지요인이 음식업 업종별 매출액에 미치는 영향 비교연구)

  • Noh, Eun Bin;Lee, Sang Kyeong
    • Korea Real Estate Review
    • /
    • v.28 no.4
    • /
    • pp.37-51
    • /
    • 2018
  • The purpose of this paper is to analyze the effects of location factors on sales by restaurant type in the six districts of Seoul (Jongno-gu, Jung-gu, Yeongdeungpo-gu, Gangnam-gu, Seocho-gu, and Songpa-gu). Ordinary least squares (OLS) regression model is selected for four restaurant types whose spatial autocorrelation is not identified, spatial lag model (SLM) is only selected for seafood restaurant, and spatial error model (SEM) is selected for nine other restaurant types. The floating population and the workers of surrounding businesses have generally positive effects on the sales of restaurants. The floating population elasticity of the sales of restaurants are found to be in the descending order of Oriental food, pub, Western food, and traditional food restaurant, and the elasticity of the workers of surrounding businesses are in the descending order of bakery, Oriental food, and Western food restaurant. The spatial multiplier effects are in the descending order of Oriental food, pub, and Western food restaurant. There is a statistically significant sales gap between roast meat, pub, and bakery in Gangnam-gu and those in five other districts. The results of this research can help in starting a restaurant in that they can provide information on the suitability of location by restaurant type.

Characteristics of Flow-Induced Noise in the Suction Nozzle of a Vacuum Cleaner with a Double-Blade Fan (이중 블레이드 팬이 장착된 진공청소기 브러쉬의 유동소음 특성)

  • Park, I-Sun;Sohn, Chae-Hoon;Oh, Jang-Keun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.2
    • /
    • pp.205-213
    • /
    • 2011
  • The characteristics of noise generation in the suction nozzle of a vacuum cleaner are analyzed numerically and experimentally. First, the flow resistance induced by each element in the suction nozzle of a vacuum cleaner with a double-blade rotary fan is investigated numerically and its relation with flow-induced noise and suction performance is examined in an anechoic room. The flow resistance and vorticity in the suction nozzle are calculated, and it is found that they are closely related to flow-induced noise and that the upper limit of noise reduction is only 4 dBA. This upper limit can be achieved by changing the design of the brush nozzle. Two methods for noise reduction by enlargement of flow-inlet area and by optimization of the number of blades are tested. Finally, the effects of each method are verified experimentally.

Blood Flow Rate Estimation using Proximal Isovelocity Surface Area Technique Based on Region-Based Contour Scheme and Surface Subdivision Flow Model (영역기반 윤곽선 기법과 표면 분할 유동모델에 기반한 근위 등속 표면적 기법을 이용한 혈류량 추정)

  • Jin, Kyung-Chan;Cho, Jin-Ho
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.38 no.1
    • /
    • pp.45-52
    • /
    • 2001
  • The proximal isovelocity surface area (PISA) method is an effective way of measuring the regurgitant blood flow rate in the mitral valve. This method defines the modelling required to describe the geometry of the isotach of the PISA. In the normal PISA flow model, the flow rate is calculated assuming that the surface of the isotach is either hemispherical or non-hemispherical numerically. However, this paper evaluated the estimate flow rate using a direct surface subdivision flow model based on the height field after isotach extraction using a region-based scheme. To validate the proposed method, the various PISA flow models were compared using pusatile color Doppler images with flow rates ranging from $30\;cm^3/sec\;to\;60\;cm^3/sec$ flow rate. Whereas the hemispherical flow model had a mean value of $29\;cm^3/sec$ and underestimated the measured flow rate by 35%, the proposed model and non-hemispherical model produced a c;ame mean value of $45\;cm^3/sec$, moreover, both flow models produced a similar pulsatile flow rate.

  • PDF

The Effect of Floating Location on Goodwill and Rent of Retail Shop -Focused on Seocho·Gangnam Commercial Area- (유동인구가 상가권리금과 임대료에 미치는 영향 -서초·강남구 상권을 중심으로-)

  • Lee, Se-won;Noh, Seung-Chul;Park, Yong-Beom;Kim, Hyun-Deok
    • Journal of Cadastre & Land InformatiX
    • /
    • v.48 no.1
    • /
    • pp.229-244
    • /
    • 2018
  • The purpose of this study is to analyze the factors affecting the influence of the size and composition of the floating population on goodwill and Rent. First, the conceptual difference between location value and rent is clearly distinguished. Second, the value of land price is divided into fixed land value and floating land value. The empirical analysis utilized consulting data from 188 shops in Seocho and Gangnam-gu in 2013 ( restaurants, resting restaurants, drinking places, general stores, entertainment and sports). The results using linear regression analysis are as follows. Goodwill and rent have a positive correlation, but the evaluation system and factors are different. Especially the influence of the floating location factor is larger than the rent. And the fixed location factors such as building deterioration bus stops, were found to be significant influencing factors in the rents, but they did not affect goodwill. This result implies that the value of location of goodwill should be taken into consideration of a temporal and spatial concept. Since, in order to resolve disputes between the landlord and the tenant, it is necessary to accumulate data continuously and to study the objective evaluation system in the future.