• Title/Summary/Keyword: 구조시험(structural test)

Search Result 1,304, Processing Time 0.126 seconds

Evaluation of Bridge Load Carrying Capacity of PSC Girder Bridge using Pseudo-Static Load Test (의사정적재하시험을 이용한 PSC 거더교의 공용 내하력평가)

  • Yoon, Sang-Gwi;Shin, Soobong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.53-60
    • /
    • 2019
  • In this study, a method for updating the finite element model of bridges with genetic algorithm using static displacement were presented, and verified this method using field test data for PSC girder bridge. As a field test, static load test and pseudo-static load test were conducted, and updated the finite element model of test bridge using each test data. Finally, evaluated the bridge load carrying capacity with updated model using pseudo-static load test's displacement data. To evaluate the bridge load carrying capacity, KHBDC-LSD, KHBDC and AASHTO LRFD's live load model were used, and compared the each results.

과하중 방지기의 전기체 구조시험 적용에 관한 연구

  • Kim, Sung-Chan;Chae, Dong-Chul;Kim, Sung-Jun;Hwang, In-Hee
    • Aerospace Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.11-17
    • /
    • 2003
  • This paper present a method of meter-out flow control for overload protection valve in full-scale airframe test. Emergency stop, which results in dump state, can be happened during full-scale airframe test by several causes. Because servo valve can't control hydraulics actuator in the dump state, pressure in cylinder chamber may rise abruptly and overload can be acted to the test article. In this paper, the procedure and technology of orifice setting are investigated to protect the test article from unexpected loads by dump. The test results show that the presented methods decrease peak loads and improve unloading characteristics of hydraulic actuators in the dump state.

  • PDF

Studies on the evaluation method of structural concrete strength using joint separation test body (접합분리 시험체를 사용한 구조체 콘크리트 강도 평가에 관한 실험적 연구)

  • Kim, Seong-Deok;Lee, Seon-Ho;Kim, Kwang-Ki;Jung, Kwang-Sik;Lim, Nam-Ki;Jung, Sang-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.993-996
    • /
    • 2008
  • It has been reported that destruction test by core collection is the most reliable of the structural concrete strength in present building construction field. But it causes low efficiency by damage and cutting in structure due to the core collection. It also has some problems in repairing. Additionally in case of strength test with management specimen, different environment compared to the structure environment cause problems about estimation precise structure strength. Therefore, it is required to develop structure direct strength test that has test values and credibility above the ones obtained by core specimen collection strength test and seasonal specimen test to suggest a reasonable and practical management method of structural concrete.

  • PDF

Study on the Impact Analysis of Front Loader for Tractor (트랙터용 프론트 로더의 충격해석에 관한 연구)

  • Lim, Gi-Soo;Lee, Boo-Youn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5051-5059
    • /
    • 2015
  • Structural behaviour of the front loader for an agricultural tractor was analyzed for three impact test conditions: drop and catch, corner pull, and corner push. Rigid-body dynamic, transient structural, and static structural analyses were conducted using a commercial finite element software. Analysis of the drop and catch test dealt with the case that the bucket located at the maximum elevation was dropped and catched through three steps. Analysis of the corner pull test dealt with the case that the bucket constrained to the ground by a chain at its corner was raised suddenly. Analysis of the corner push test dealt with the case that the corner of the bucket collided with an obstacle. Results of analyses of the three test conditions showed that maximum stress occurs at the geometrically discontinuous location in the mount and is caused from local stress concentration. Results of the present research can be utilized as a guideline to achieve more reliable and safe structural design of the front loaders.

Test research of Structural Safety for Steel Wire-Integrated Deck Plate System (철선일체형 데크 플레이트 구조성능평가를 위한 실험적 연구)

  • Lee, Yong-Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.6
    • /
    • pp.220-228
    • /
    • 2010
  • A steel wire-integrated deck plate that welds integrated triangle truss steel wires on a galvanized steel sheet is developed to reduce construction costs of a slab or formwork such as shores and supports, and it is already widely applied in many construction fields. This study selected upper and lower steel wires, lattice steel wires, span, and cutting methods of ends as variables, and conducted an experimental test by manufacturing a total of 32 full scale test bodies. According to the result, changes in final destruction types of the test bodies and cutting methods of ends didn't affect structural performance of test bodies, and for a 3.2m-span test body, there was no big problems in using ${\Phi}4.5$ of lattice steel wires.

전기체 정적시험 치구설계 기술보고서

  • Kim, Sung-Chan;Shin, Jeong-Woo;Shim, Jae-Yeul;Hwang, In-Hee
    • Aerospace Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.32-44
    • /
    • 2002
  • This paper contains the information that describes the test fixture design and technology for full-scale airframe static test. Obtained technologies consist of determination of design load for test fixture, design technique for loading system, counterbalance system, positioning system of test article, test equipment and overload protection method. Full-scale airframe static test of advanced jet trainer was implemented using test fixture which are applied these technique.

  • PDF

Ground Test & Evaluation of Conformal Load-bearing Antenna Structure for Communication and Navigation (통신 항법용 다중대역 안테나 내장 스킨구조의 지상시험평가)

  • Kim, Min-Sung;Park, Chan-Yik;Cho, Chang-Min;Jun, Seung-Moon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.11
    • /
    • pp.891-899
    • /
    • 2013
  • This paper suggests a test and evaluation procedure of conformal load-bearing antenna structure(CLAS) for high speed military jet application. A log periodic patch type antenna was designed for multi-band communication and navigation antenna. Carbon/Glass fiber reinforced polymer was used as a structure supporting aerodynamic loads and honeycomb layer was used to improve antenna performance. Multi-layers were stacked and cured in a hot temperature oven. Gain, VSWR and polarization pattern of CLAS were measured using anechoic chamber within 0.15~2.0 GHz frequency range. Tension, shear, fatigue and impact load test were performed to evaluate structural strength of CLAS. Antenna performance test after every structural strength test was conducted to check the effect of structural test to antenna performance. After the application of new test and evaluation procedure to validate a new CLAS, a design improvement was found.

Space Simulation Test and Thermal Verification of HAUSAT-2 STM (Structural-Thermal Model) by Using Surface Heaters (표면히터를 이용한 HAUSAT-2 위성 STM의 우주모사 및 열해석 검증 연구)

  • Lee, Mi-Hyeon;Kim, Dong-Woon;Hwang, Ki-Lyong;Chang, Young-Keun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.11
    • /
    • pp.106-114
    • /
    • 2005
  • This study addresses space simulation test results and thermal modelling verification of HAUSAT-2 nanosatellite STM (Structural-Thermal Model). The thermal modelling of the HAUSAT-2 has been modified in accordance with test results. Thermal analysis results were repeatedly compared with test results for modified thermal modelling. It is verified that the analysis results for modified thermal modelling agree well with test results. Some surface heaters were implemented to simulate solar illumination for HAUSAT-2 Thermal Vacuum/Balance Test. A low-cost and effective thermal test methodology, which is applicable to ultra-small satellite system, was proposed and verified by test results in this study.

Experimental Fatigue Characteristics of Composite Bridge Deck of Hollow Section (중공단면 복합소재 교량 바닥판의 실험적 피로특성 분석)

  • Lee, Sung-Woo;Hong, Kee-Jeung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.19 no.4 s.74
    • /
    • pp.337-345
    • /
    • 2006
  • In this study, to evaluate fatigue characteristics of developed composite bridge deck, compression fatigue test at girder support and flexural fatigue test for the 2.8m-long flexural test model were carried out. For the test specimen, DB 24 truck load was applied up to 2,000,000 cycles. In the compression fatigue test, behavior at deck tube and its bonded connection were evaluated. In the flexural fatigue test, deck behavior at mid-span and girder connection were evaluated.

High-temperature Structural Analysis of Small-scale Prototype of Process Heat Exchanger (III) (공정열교환기 소형 시제품에 대한 고온구조해석(III))

  • Song, Kee-Nam;Lee, Heong-Yeon;Kim, Chan-Soo;Hong, Seong-Duk;Park, Hong-Yoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.2
    • /
    • pp.191-200
    • /
    • 2011
  • A PHE (Process Heat Exchanger) is a key component of nuclear hydrogen system for massive production of hydrogen; the PHE transfers the very high temperature heat ($950^{\circ}C$) generated from the VHTR (Very High Temperature Reactor) to a chemical reaction. The Korea Atomic Energy Research Institute developed a small-scale gas loop for testing the performance of VHTR components and manufactured a modified PHE prototype for carrying out the testing in the gas loop. In this study, as a part of the evaluation of the high-temperature structural integrity of the modified PHE prototype which is scheduled to test in the gas loop, we carried out high-temperature structural analysis modeling, macroscopic thermal and structural analysis of the PHE prototype under the gas loop test conditions as a precedent study before carrying out the performance test in the gas loop. The results obtained in this study will be used to design the performance test setup for the modified PHE prototype.