• Title/Summary/Keyword: 구조손상평가

Search Result 985, Processing Time 0.028 seconds

Tsunami Fragility Evaluation for Offsite Transformer in Nuclear Power Plants (지진해일에 의한 원자력발전소 소외변압기의 취약도 평가)

  • Kim, Min Kyu;Choi, In-Kil;Kang, Keum Seok
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.22 no.1
    • /
    • pp.18-24
    • /
    • 2010
  • In this study, a tsunami fragility methodology was determined for a probabilistic safety assessment(PSA) induced tsunami event in Nuclear Power Plant(NPP) site. For this purpose, a fragility evaluation method was presented using previous external PSA method. Failure mode and failure criteria about major safety related equipments and structures were determined. Finally, a tsunami fragility assessment was performed for offsite transformer in NPP site. For the fragility evaluation, structural failure like overturning and sliding and functional failure induced by inundation. Through this study, it can be concluded that a functional failure according to inundation height was governed total probability of failure of offsite transformer in NPP.

Seismic Performance Evaluation of URM Buildings Using Capacity Spectrum Analysis (역량스펙트럼해석을 통한 조적조 건축물의 내진성능평가)

  • Kim, Jin-Seon;Lee, Jung-Han;Kim, Hye-Won;Park, Byung-Cheol;Yi, Waon-Ho
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.137-140
    • /
    • 2010
  • 본 논문에서는 국내 지진발생 시 비보강 조적조 건축물의 손상상태 예측 및 내진성능 평가를 위해 기존건축물을 대상으로 역량스펙트럼 해석을 수행하였다. 이는 지진피해를 보다 상세하게 예측하고 건축물의 거동을 파악하기 위한 방법으로 국내 설계 지진하중과 부재의 비선형 특성을 적용하여 해석을 수행하였으며 해석 결과는 구조물의 손상상태에 따라 Slight, Moderate, Extensive, Complete 등으로 구분하여 평가하였다. 그 결과 대부분의 건축물에서 약간의 구조적 피해(Slight)와 보통의 구조적 피해(Moderate) 정도로 나타났으며, 일부 건축물에서 심각한 구조적 피해(Extensive)가 발생하는 것으로 예측되었다. 이전 연구에서 비보강 조적조 건축물의 내진성능평가를 위해 구조내진판정지표를 사용하여 내진성능을 판정하였으며 대부분의 비보강 조적조 건축물이 내진성능을 만족하지 못하였다. 본 연구에서는 기존 건축물에 구조내진 판정지표를 적용하고 그 결과를 바탕으로 역량스펙트럼 해석을 함에 따라 보다 상세한 구조물의 피해정도를 예측할 수 있었다.

  • PDF

Multi-Damage Detection in RC Bridges Using Differential Evolutionary Algorithm (차분진화 알고리즘을 이용한 다중 손상된 RC교량의 손상평가)

  • Tak, Moon-Ho;Noh, Myung-Hyun;Park, Tae-Hyo;Jang, Han-Teak
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.296-299
    • /
    • 2009
  • 본 논문은 차분진화 알고리즘을 이용한 다중 손상된 RC 슬라브 교량에 대한 시스템 인식(System Identification)기법을 소개한다. 제안된 기법을 이용하여 이동하중에 의한 교량의 동적응답을 기반으로 손상유무, 위치, 크기가 추정된다. ABAQUS를 이용한 손상된 3차원 슬라브 모델을 실험대상으로 하여, 모델로부터 동적응답을 찾아내었다. 차분진화 알고리즘(Differential Evolutioinary algorithm)을 기반으로 동적응답과 Bi-variate Gaussian 함수로 강성저하된 2차원 유한요소 MZC모델을 이용하여 손상된 위치와 크기, 이동하중의 크기와 속도가 추정되었다. 차분진화 알고리즘을 이용한 RC교량의 손상위치와 이동하중에 대한 추정은 3%이내의 오차를 보였고, 이로부터 제안된 방법의 효율성과 정확성이 검증되었다.

  • PDF

Shear Damage Behavior of Reinforced Concrete Beams under Fatigue Loads (반복하중을 받는 철근콘크리트보의 전단피로손상거동)

  • 오병환;한승환;이형준;김지상;신호상
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.1
    • /
    • pp.143-151
    • /
    • 1998
  • 최근들어 반복하중에 의한 철근콘크리트 구조물의 손상이 자주 발견되고 있으며 교량 등의 구조물 등은 때때로 과적차량에 의한 초과하중을 받아 이러한 피로손상이 심화되고 있다. 본 연구에서는 이러한 반복 하중을 받는 철근 콘크리트보의 누적피로손상에 대한 실험적 연구룰 수행하여 피로하중에 의한 철근콘크리트보의 손상과정을 규명하였다. 실험 변수를 전단철근의 양과 반복되는 하중의 크기 및 반복횟수로 하여 실험부재를 제작하였으며, 하중제어에 의한 휨시험법에 의해 3Hz의 반복하중을 시편에 재하하였다. 사인장 균열하중과 사인장 균열 후 반복하중에서의 보의 손상누적거동 즉 처짐. 전단철근의 변형도, 에너지 손실 등의 변화를 실험적으로 평가하였으며, 이를 통하여 반복하중에 의한 누적손상에 의해 철근 콘크리트보의처짐 및 전단변형도가 초기하중상태에서는 급격히 증가하다가 이후 점진적으로 증가하는 것을 규명하였다. 본 연구의 결과는 사용하중상태에서 점진적으로 발생할 수 있는 피로손상의 누적과정을 기술하여 주고 있다.

Relationship between Crack Characteristics and Damage State of Strengthened Beam (보강된 보의 균열특성과 손상상태의 상관관계)

  • 한만엽;김상종
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.805-812
    • /
    • 2002
  • The number of old concrete structure which needs to be strengthened has been increased. The repair and strengthening methods have to be determined based on the current status of the structure. Consequently the estimation method for the damage status of the structure has been desperately needed, but no studies have been tried to use the crack and deflection characteristics to estimate the damage status. In this study, the crack characteristics depending on load level were measured and analysed. The crack characteristics observed from 11 samples were compared with damage status, and load level, The crack characteristics examined in this study include crack number, crack length, crack range, crack interval, maximum crack length, crack area, and average crack length. The deflections were normalized based on yield deflection, and the relationship between the relative deflection and the standardized crack characteristics were compared. Among the crack characteristics, crack interval, crack area, crack range, and maximum crack length, have been showed a close relationship to the relative deflection. Therefore, if such crack characteristics are evaluated, the maximum load applied to the structure is believed to be estimated. if additional parameters such as size of specimen, strength of concrete and steel, and steel ratio are studied, the damage status of structure can be estimated more accurately.

Quantitative Damage Index of RC Columns with Non-seismic Details (비내진상세를 가지는 철근콘크리트 기둥의 정량적 손상도 평가 기준)

  • Kim, Kyung-Min;Oh, Sang-Hoon;Choi, Kwang-Yong;Lee, Jung-Han;Park, Byung-Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.6
    • /
    • pp.11-20
    • /
    • 2013
  • In this paper, the quantitative damage index for reinforced concrete (RC) columns with non-seismic details were presented. They are necessary to carry out the postearthquake safety evaluation of RC buildings under 5 stories without seismic details. The static cyclic test of the RC frame sub-assemblage that was an one span and actual-sized was first conducted. The specimen collapsed by the shear failure after flexural yielding of a column, lots of cracks on the surfaces of columns and beam-column joints and the cover concrete splitting at the bottom of columns occurred. The damage levels of these kinds of columns with non-seismic details were classified to five based on the load-displacement relationship by the test result. The residual story drift ratios and crack widths were then adapted as the quantitative index to evaluate the damage limit states because those values were comparatively easy to measure right after earthquakes. The highest one among the residual story drift ratios under the similar maximum story drift ratio decided on the residual story drift ratio of each damage limit state. On the other hand, the lowest and average ones among the respective residual shear and flexural widths under the similar maximum story drift ratio decided on the residual shear and flexural widths of each damage limit state, respectively. These values for each damage limit state resulted in being smaller than those by the international damage evaluation guidelines that are for seismically designed members under the same deformations.

Stability of Analytical Fragility Curve of Bridge on Earthquake (지진의 변화에 따른 교량의 해석적 손상도 곡선의 안정성)

  • Lee, Jong-Heon;Lee, Soo-Choul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.2 s.54
    • /
    • pp.145-152
    • /
    • 2009
  • In performing a risk analysis on structure for earthquake, it is imperative to identify the vulnerability of structures associated with various stages of damage. And the earthquake resisting capability is needed for structures like bridge. So the damage analysis of bridges with or without isolator for earthquake effects is necessary. In this paper, the risk analysis of seismic isolated LRB bridges considering earthquake effects such as PGA, PGV, SA, SV, and SI is performed using fragility curves to assure the earthquake resisting capability of the structures. And, the stability of fragility curve is investigated with respect to input earthquake.

Impact Damage Detection of Smart Composite Laminates Using Wavelet Transform (웨이블릿 변환을 이용한 스마트 복합적층판의 충격 손상 검출 연구)

  • 성대운;오정훈;김천곤;홍창선
    • Composites Research
    • /
    • v.13 no.1
    • /
    • pp.40-49
    • /
    • 2000
  • The objective of this research is to develop the impact monitoring techniques providing impact identification and damage diagnostics of smart composite laminates susceptible to impacts. This can be implemented simultaneously by using the acoustic waves by the impact loads and the acoustic emission waves from damage. In the previous research, we have discussed the impact location detection process in which impact generated acoustic waves are detected by PZT using the improved neural network paradigm. This paper describes the implementation of time-frequency analysis such as the Short-Time Fourier Transform (STFT) and the Wavelet Transform (WT) on the determination of the occurrence and the estimation of damage.

  • PDF

Estimation of Cable Damages using Piezo Disk and Optical Fiber Sensors (압전소자와 광섬유센서를 이용한 케이블의 손상평가)

  • Park, Kang-Geun;Kim, Ie-Sung
    • Journal of Korean Association for Spatial Structures
    • /
    • v.9 no.3
    • /
    • pp.67-74
    • /
    • 2009
  • Presently means of utilizing sensors such as Piezoelectric(PZT) Element for evaluating the affect of oscillator, strain gauge for analyzing physical changes and use of Fiber Bragg Grating(FBG) Sensor are widely practiced in the field. In this study, PZT and FBG sensors were used to tearing damage of cable systems in these sensors. Cable systems are a construction of elements carrying only tension and no compression or bending in membrane structure. But damage detection of cable systems by using existing safety diagnosis is difficult to detect the characteristic change of overall structural action. If cable snaps are occurred to cable release and tear in tension structures, these are set up a vibration. So, we used piezo-electric materials and result of experiment using this was compared with result of experiment using FBG sensors The purpose of this research is to develop of damage detection method of cable system in tensile stress.

  • PDF

The Relationship between Damage Pattern and Structural Performance for 7-Wire Strand of Stay Cables (사장교 케이블용 7연선 손상 패턴과 구조성능 수준과의 관계 분석)

  • Seo, Dong-Woo;Na, Wongi;Kim, Byung-Chul;Park, Ki-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.810-816
    • /
    • 2017
  • This study investigates the relationship between the damage patterns and structural performance levels of a multi-strand 7-wire strand that is used as an important member of stay cables. Stay cables are continuously damaged after completion, and corrosion is the main cause. However, it is difficult to check the damage pattern inside the cable due to its structural characteristics, and it is difficult to evaluate the degradation level of the damage quantitatively. This study derives the relationship between the damage pattern and the performance level of the stranded wire by comparing results and analyzing them through an indoor experiment and finite element analysis. In order to simulate the damage of a 7-wire strand, artificial damage was applied by mechanical precision machining to perform a performance evaluation. The results of the analysis show that regardless of the damage size of the strand, the structural performance deteriorated immediately after the damage. It was experimentally and analytically deduced that the type and amount of damage should be considered as a parameter for evaluating the performance level of the strand. This information can be used for the safety management of a cable stayed bridge by constructing a database according to the pattern and amount of damage.