• Title/Summary/Keyword: 구조성능 실험

Search Result 5,142, Processing Time 0.032 seconds

Experimental Techniques for Evaluating Seismic Performance of Base-Isolated Structure (기초격리된 구조물의 내진성능평가를 위한 실험기법)

  • 윤정방;정우정;김남식;김두훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.4
    • /
    • pp.45-58
    • /
    • 1997
  • This paper describes a series of shaking table and pseudodynamic tests for evaluation of seismic performance of base-isolated structures subjected to various seismic earthquake inputs. The main objectives of this study are : (1) evaluation of the effectiveness of base-isolation systems for low-rise structures against severe seismic loads through shaking table tests, (2) verification of the substructuring pseudodynamic test method for the base-isolated structures in comparison with the shaking table test results. In the shaking table test, a quarter scaled three-story structure base-isolated by laminated rubber bearings is tested. In the pseudodynamic test, only the laminated rubber bearing s are tested using the substructuring technique, while the concurrent seismic responses of the superstructure are computed using on-line numerical integration. Comparison with the shaking table test results indicates that the substructuring pseudodynamic test method is very effective for determining the dynamic responses of the base-isolated structure.

  • PDF

다양한 분포의 데이터를 이용한 시계열 패턴 인덱스의 성능 비교

  • 김영인
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 1998.10a
    • /
    • pp.791-805
    • /
    • 1998
  • 음성데이타베이스 이미지 데이터베이스 등과 같은 응용에서 다차원 구조의 시계열 패턴을 효율적으로 처리하기 위한 인덱스 구조가 필요하다. 이러한 인덱스구조로 시계열 패턴 인덱스(9)가 제안되었다. 본 논문에서는 시계열 패턴 인덱스가 실제 응용에 적용가능한가를 판단하기 위하여 , 다양한 분포의 대량 데이터를 이용한 실험을 통한 성능을 비교한다. 성능 실험결과 저장시의 성능은 균일 분포에서 좋은 성능을 나타냈다. 질의 처리시의 성능은 모든 분포에서 좋은 후보 선택의 결과를 나타냈다.

A Study on Similitude Law for Evaluation of Seismic Performance (내진성능평가를 위한 상사법칙에 관한 연구)

  • Kim, Nam-Sik;Kwak, Young-Hak;Chang, Sung-Pil
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.208-215
    • /
    • 2003
  • 지진하중에 대한 구조물의 동적 거동과 성능을 예측 평가하기 위하여 실험적 방법들이 흔히 사용되고 있으나, 실험장비의 제약과 구조물의 규모 등으로 대부분 축소모형실험에 의존하고 있다. 그러나 일반적인 상사법칙(similitude law)은 탄성범위에서 유도된 것으로 지진거동과 같은 비탄성 거동을 예측하는 경우에는 한계가 있다. 또한 탄성범위 내에서도 크기효과(size offset)가 발생하므로 축소모형의 실험결과를 원형 구조물에 직접 적용하는 것은 많은주의가 필요하다. 본 연구에서는 원형 구조물(prototype)과 축소모형(scaled model)을 모두 실험 대상으로 하여 실제 축소모형만을 실험하여 원형 구조물의 거동을 예측하는 경우의 문제점을 확인하고 그 해결방법을 모색하고자 한다. 실제로 축소모형실험에서는 원형 구조물의 경계조건을 정확히 재현하기 어려우며, 실험모형의 제작과정과 실험과정에서의 모든오차가강성의 변화로 반영되어 나타난다. 따라서 본 연구에서는 기하학적 상사율과 변화된 강성비(stiffness ratio)를 함께 고려하여 고유진동수의 오차를 보정하고 비탄성 거동중에도 직접적인 실험결과의 비교가 가능한 상사법칙을 제안하였다. 더불어 제안된 상사법칙을 적용한 유사동적실험 (pseudodynamic test)을 수행하여 실험오차보정(experimental error compensation)효과를 검증하였다.

  • PDF

Structural Performance Evaluation on Flexural and Shear Capacity for Weight Reducing Steel Wire-Integrated Void Deck Plate Slab (자중저감 철선일체형 중공 데크플레이트 슬래브의 휨 및 전단내력에 대한 구조성능평가)

  • Kim, Sang-Seup;Ryu, Deog-Su;Boo, Yoon-Seob
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.4
    • /
    • pp.411-422
    • /
    • 2012
  • The purpose of this study is to evaluate the flexural and shear capacity of steel wire-integrated void deck plate slabs. In order to evaluate flexural and shear capacity, we make five 150mmspecimens and three 200mmspecimens by slab depth as main variable. Each series of specimen is comprised of an existing steel wire-integrated deck-plate slab and two specimens using topping depth as variable. From the series of experiments, steel wire-integrated void deck plate slabs has any decline in flexural and shear performance. Therefore, a void-deck-plate slab which inserts Omega-steel plate showed reducing a using concrete-volume and had flexural and shear capacity following existing steel wire-integrated deck-plate.

Assessment of the Seismic Capacity of Structure Using Pseudodynamic Test (유사동적 실험법을 이용한 구조물의 내진 성능 평가)

  • 김대곤;김대영;안재현;박칠림
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.2
    • /
    • pp.49-57
    • /
    • 1997
  • It is necessary to conduct researches about seismic design and analysis to protect various structures from earthquakes which are one of the most destructive natural disaster to human civilization. To assess the seismic capacity of structure, not only analytical but also experimental researches are important. Currently, pseudodynamic test known as computer-actuator on-line test is one of the available test methods to assess seismic capacity of structure without using shaking table. In this paper seismic capacity of simple one-degree of freedom structure was estimated by pseudodynamic test. Good agreement between the experimental and analytical results was obtained. Better results would be obtained when more sophisticated measuring and controlling instruments are available.

  • PDF

Structural Health Monitoring System Employing Smart Sensor Technology Part 1: Development and Performance Test of Smart Sensor (스마트 센서 기술을 이용한 구조물 건전도 모니터링 시스템 Part I : 스마트 센서의 개발과 성능평가)

  • Heo, Gwang Hee;Lee, Woo Sang;Kim, Man Goo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.2
    • /
    • pp.134-144
    • /
    • 2007
  • In this study, a smart sensor unit is developed by using the smart sensor technology that is being rapidly developed in recent years for structural health monitoring system, and its performance is evaluated through various experiments, and also, damage detection experiment is performed on a model structure. This paper as the first half of this study contains the development and performance evaluation of the smart sensor. In the latter half of this study, structure damage detection experiment is performed for the application of verified smart sensor unit into structural health monitoring, and it is compared with a wire measurement system. The smart sensor is developed by using high-power wireless modem, MEMS Sensor and AVR microcontroller, and an embedded program is also developed for the control and operation of the sensor unit. To verify the performance of the smart sensor, many experiments are performed for sensitivity and resolution analysis tests, data acquisition by using cantilever beam and shaker, and on-site application using actual bridge. As a result, the smart sensor proves to be satisfactory in its performance.

Parallel Programming for Exploiting Hybrid Parallel Model of CLUMP system and its Performance Evaluation (다중 메모리 모델의 CLUMP 시스템을 이용하기 위한 병렬 프로그래밍 기법과 성능 평가)

  • 이용욱;라마크리쉬나
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2000.10c
    • /
    • pp.621-623
    • /
    • 2000
  • 클러스터를 구성하는 단위 노드로 SMP가 새로운 대안으로 시장에 등장하였다. 이러한 멀티프로세서 클러스터(CLUMP)는 하나의 시스템에 다중 메모리 구조를 가지는데, CLUMP가 가지는 다중 메모리 구조를 효과적으로 사용하기 위해서 본 논문에서는 중첩된 병렬화 프로그램 모델을 제안하였다. 중첩된 병렬화 모델은 중첩된 루프 레벨의 병렬화, 중첩된 태스크 레벨의 병렬화, 그리고 다중 중첩된 병렬화로 나뉜다. 본 논문에서는 중첩된 루프 레벨의 병렬화를 실험대상으로 하여 그 성능을 평가하고 단일 메모리 구조의 병렬화 프로그램과 성능을 비교하였다. 실험 결과 시험한 중첩된 병렬화 모델이 단일 메모리 구조의 병렬화 프로그램에 비하여 좋은 성능을 나타내었지만, 실험대상이 된 루프 레벨 병렬화의 잠재적인 특징으로 인해 실행에 참여하는 노드 수가 많아질수록 성능 향상 폭이 감소하는 결과를 보였다. 프로그램의 성능 향상 폭과 확장성은 문제 크기가 클수록 좋은 특성을 보였다.

  • PDF

Seismic Capacity Evaluation of Wood Structure Using Soil-Wall Test (흙벽 실험에 의한 목조 건축물의 내진성능 평가)

  • Kim, Hye-Won;Yang, Won-Jik;Oh, Sang-Hoon;Lee, Jung-Han;Park, Byung-Cheol;Yi, Waon-Ho
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.409-412
    • /
    • 2010
  • 본 연구는 목조 건축물 흙벽의 수평가력실험 결과를 이용한 내진성능 평가를 목적으로 한다. 흙벽 실험시험체는 기둥과 보 결합방식에 따라 민도리, 초익공, 장여방식으로 분류되고 벽체 형태에 따라 창문, 문, 전면 벽체, 인방 부재수 등으로 계획을 하였다. 12개 흙벽 시험체의 가력결과, 전면 벽체 시험체는 변위각 1/30에서 가장 큰 강성 저하율을 보이며 중인방과 수직재가 있는 벽체는 에너지 소산능력이 가장 큰 것으로 나타났다. 기존 연구로부터 목조 건축물 항복점 평가방법을 이용하여 등가탄소성 곡선으로 나타낸 전단내력은 민도리방식이 프레임과 전면 벽체일 경우 가장 크고, 전단응력은 벽체 개구율에 따라 다르게 나타났다. 실험결과로부터 적용 대상 건축물의 X, Y방향 구조성능을 산출하고 구조내진지표와 역량스펙트럼을 이용하여 내진성능 평가를 실시한 결과, 대상 목조 건축물은 내진성이 있음으로 평가되었다.

  • PDF

An Experimental Study on The Fire Resistance Performance of Steel Framed motar Beam with Loading Condition (철골철망 모르타르 보의 재하하중에 따른 내화성능변화에 관한 실험적 연구)

  • Kim, Hyung-Jun;Kim, Heung-Youl;Cho, Bum-Yean;Yeo, In-Hwan;Min, Byung-Youl
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.103-106
    • /
    • 2011
  • 국토해양부령 제320호인 건축물의 피난 방화구조 등의 기준에 관한 규칙 제 3조에서는 내화구조에 관한 세부기준을 정하고 있다. 이러한 법정내화구조 중에서 철골철망 모르타르조의 피복두께에 따른 내화성능 변화를 분석하기 위하여, 본 연구에서는 고온 재하하중조건에서 내화실험을 수행하였다. 철골조의 피복두께를 50 mm ${\cdot}$ 60 mm ${\cdot}$ 70 mm로 변화하여 내화실험을 수행하였으며, 재하하중비를 변화시킴으로 동일 피복두께에서의 내화성능 변화를 분석하고자 하였다. 실험결과 단면소성모멘트 대비 하중비 0.4 조건에서의 철골철망 모르타르조의 내화성능은 180분이 나왔으며, 피난 방화구조 등의 기준의 별표 1에서 정하고 있는 내화구조의 성능기준 중 최대 내화성능시간인 3시간을 확보하는 것으로 나타났다.

  • PDF

Shaking Table Test for Seismic Performance Evaluation of Non-Seismic Designed Wall-Type Apartment (내진설계 되지 않은 공동주택의 진동대 실험에 의한 내진성능 평가)

  • Chung, Lan;Lee, Joung-Woo;Park, Tae-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.6 s.96
    • /
    • pp.721-728
    • /
    • 2006
  • Earthquakes are reported thai building structures have been colossal damaged, but before 1988 designed structures which were not applicate seismic design code have no seismic performance. Especially, for the apartment structures were indicated that it have no resist wall element of earthquake before 1988 designed structures. We have to evaluate for seismic performance this structures, therefore it will be retrofitted for seismic index sufficient structures. We performed seismic performance evaluation for model structures by MIDAS which is general structure analysis software. In this study, it was performed shaking table test to evaluate model structure which is reinforcement concrete and 5 floors for seismic performance index. We made specimens by similar's law and tested shaking table test. In the shaking table test it is not performed prototype model test because of space and equipment condition. So we had made scale-down model for 1/5 by similar's law. That's why it needs for the evaluation of performance. However, it is not possible to do an experiment of prototype owing to the shortage of space and the limit of an experimental instrument in the shaking table test. Then, modeling and reducing the part of prototype do the experiment. In this experiment a shaking table test is done and seismic performance of model structures is evaluated by using similitude laws for scale down specimen. As a result it is proved that non-seismic design structures need to retrofit since seismic performance shows life safe grade in 0.12g of an earthquake.