• Title/Summary/Keyword: 구강 촬영

Search Result 212, Processing Time 0.033 seconds

Evaluation of Xerostomia Following 3 Dimensional Conformal Radiotherapy for Nasopharyngeal Cancer Patients (3차원 입체조형 방사선치료를 시행받은 코인두암 환자에서의 구강건조증 분석)

  • Park Young-Je;Park Won;Ju Sang-Gyu;Nam Hee-Rim;Oh Dong-Ryul;Park Hee-Chul;Ahn Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.24 no.2
    • /
    • pp.81-87
    • /
    • 2006
  • Purose: This study is to evaluate the xerostomia following 3-dimensional conformal radiation therapy (3D CRT) in nasopharynx cancer patients using the xerostomia questionnaire score (XQS). Materials and Methods: Questionnaire study was done on 51 patients with nasopharynx cancer who received 3D CRT from Dec. 2000 to Aug. 2005. 3D CRT technique is based on 'serial shrinking field' concept by 3 times of computed tomography (CT) simulation. Total target dose to the primary tumor was 72 Gy with 1.8 Gy daily fractions. Xerostomia was assessed with 4-questions XQS, and the associations between XQS and time elapsed after RT, age, sex, stage, concurrent chemotherapy, and parotid dose were analyzed. Results: Concurrent chemotherapy was given to 40 patients and RT alone was given to 11 patients. The median time elapsed after 3D CRT was 20 ($1{\sim}58$) months and the mean XQS of all 51 patients was $8.4{\pm}1.9\;(6{\sim}14)$. XQS continuously and significantly decreased over time after 3D CRT ($X^2$=-0.484, p<0.05). There was no significant difference in XQS according to sex, age, and stag. However, XQS of concurrent chemotherapy patients was significantly higher than RT alone patients (P=0.001). XQS of patients receiving total mean parotid dose ${\ge}35 Gy$ was significantly higher than <35 Gy (p=0.05). Decreasing tendency of XQS over time after 3D CRT was observed. Concurrent chemotherapy and total mean parotid dose ${\ge}35 Gy$ were suggested to adversely affect radiation-induced xerostomia.

Comparison of Behavioral Response between Intranasal and Submucosal Midazolam Adminstration (소아 진정 치료 시 구강 점막 하와 비점막 Midazolam 투여의 행동 반응 비교)

  • Kim, Yun-Hee;Jung, Sang-Hyuk;Baek, Kwang-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.3
    • /
    • pp.427-436
    • /
    • 2008
  • Purpose. The objective of this study was to evaluate the behavioral response and assess the effectiveness of additional intranasal (IN) and submucosal (SM) administration of midazolam during pediatric sedation for dental procedure. Material and methods. Thirty-three cases of healthy (ASAⅠ), uncooperative children aged from 24 to 72 month old at pediatric dental clinic of Ewha Womans University Hospital were selected for this study. Children received oral chloral hydrate 50 mg/kg with hydroxyzine 1.0 mg/kg. After waiting for 45 minutes, midazolam 0.2 mg/kg was administrated via IN route and via SM route randomly maintaining 50% of $N_2O$. A pulse oximeter and a capnograph were used for measuring vital signs ($SpO_2$, PR, RR, $EtCO_2$) throughout the sedation. Behavioral response was evaluated as Quiet (Q), Crying (C), Movement (M) or Struggling (S) in every 2 minutes for 40 minutes. Results. There were also no statistically significant differences in vital signs of the two groups. The behavioral response for the first ten minutes during sedation was a statistically significant difference (P < 0.05) between the two groups. After the first ten minutes, it was revealed that there was no significant difference. Conclusion. This study demonstrated that the addition of IN midazolam to the combination of oral chloral hydrate with hydroxyzine and nitrous oxide/oxygen inhalation is as safe and effective as that of SM midazolam in pediatric sedation for dental procedure.

  • PDF

Medical Radiation Exposure Dose of Workers in the Private Study of the Job Function (의료기관 방사선 종사자의 직무별 개인피폭선량에 관한 연구)

  • Kang, Chun-Goo;Oh, Ki-Baek;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.3-12
    • /
    • 2011
  • Purpose: With increasing medical use of radiation and radioactive isotopes, there is a need to better manage the risk of radiation exposure. This study aims to grasp and analyze the individual radiation exposure situations of radiation-related workers in a medical facility by specific job, in order to instill awareness of radiation danger and to assist in safety and radiation exposure management for such workers. Materials and Methods: From January 1, 2010 December 31, 2010, medical practitioners working in the radiation is classified as a regular personal radiation dosimetry, and subsequently one year 540 people managed investigation department to target workers, dose sectional area, working period, identify the job function-related tasks for a deep dose, respectively, the annual average radiation dose were analyzed. Frequency analysis methods include ANOVA was performed. Results: Medical radiation workers in the department an annual radiation dose of Nuclear and 4.57 mSv a was highest, dose zone-specific distribution of nuclear medicine and in the 5.01~19.05 mSv in the high dose area distribution showed departmental radiation four of the annual radiation dose of Nuclear and 7.14 mSv showed the highest radiation dose. More work an average annual radiation dose according to the job function related to the synthesis of Cyclotron to 17.47 mSv work showed the highest radiation dose, Gamma camera Cinema Room 7.24 mSv, PET/CT Cinema Room service is 7.60 mSv, 2.04 mSv in order of intervention high, were analyzed. Working period, according to domain-specific average annual dose of radiation dose from 10 to 14 in oral and maxillofacial radiology practitioners as high as 1.01~3.00 mSv average dose showed the Department of Radiology, 1-4 years, 5-9 years, respectively, 1.01 workers~8.00 mSv in the range of the most high-dose region showed the distribution, nuclear medicine, and the 1-4 years, 5-9 years 3.01~19.05 mSv, respectively, workers of the highest dose showed the distribution of the area in the range of 10 to 14 years, Workers at 15-19 3.01~15.00 mSv, respectively in the range of the high-dose region were distributed. Conclusion: These results suggest that medical radiation workers working in Nuclear Medicine radiation safety management of the majority of the current were carried out in the effectiveness, depending on job characteristics has been found that many differences. However, this requires efforts to minimize radiation exposure, and systematic training for them and for reasonable radiation exposure management system is needed.

  • PDF

Evaluation of the Volume Changes of Grafted Bone Materials in Sinus Augmentation Procedure Using Dental Cone-beam CT (치과용 Cone-beam CT를 이용한 상악동 골 이식 후 나타난 골 이식재의 부피 변화평가)

  • Ohn, Byung-Hun;Seon, Hwa-Kyeong;Chee, Young-Deok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.23-36
    • /
    • 2013
  • To evaluate the 3-dimensional features of the grafted bone with maxillary sinus augmentation and to assess the relation between the degree of bone resorption and the type of bone grafting source and implant, and the operation method. A retrospective chart review of patients receiving sinus augmentation procedures for implant positioning was conducted: radiographic analysis of the volume and area of bone grafts was performed. The volumetric remodeling.measured at 6 months after implant positioning as the percentage of residual bone graft.was correlated to type of graft materials and operation methods. 53 dental implants positioned with sinus bone graft in 15 patients at Wonkwang University Sanbon Dental Hospital. Computed tomography scans,taken implant positioning after 6 months, showed greater resorption values for the group of $Puros^{(R)}$ graft alone from the group of mixed with $Puros^{(R)}$ and various bone graft (P<0.05, respectively). And resorption values according to operation methods have statistically significant difference(P<0.05). Volume change ratio of bone graft showed greater values for the group of delayed implant position from the group of simultaneously implant placement with bone graft. Retrospective data analysis shows that the method of graft with $Puros^{(R)}$ alone may occur greater resorption of graft materials than mixed graft material with $Puros^{(R)}$ and other graft materials. The group of simultaneously implant placement with bone graft also display smaller resorption ratio of bone graft than the group of delayed implant placement.

Diagnosis and Management of Lymphoplasmacytic Rhinitis in a Cat (림포형질세포성 비염에 이환된 고양이의 진단과 치료)

  • Kang, Min-Hee;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.28 no.4
    • /
    • pp.438-441
    • /
    • 2011
  • A 7-year-old castrated, domestic shorthair cat was presented with a 2-year history of chronic nasal discharge and sneezing. Upon presentation, bilateral mucopurulent nasal discharge and stertorous respiration were marked. Physical examination revealed a tachypnea. Oral examination was unremarkable and chest radiology was normal. Findings of nasal cytology and skull radiology were not specific and further imaging technique, endoscopic examination and histopathology was performed for a definite diagnosis. Fluid, and/or soft tissue opacity was found in bilateral nasal cavity, nasopharyngeal regions and right side tympanic bulla through the CT scan. No evidence of neoplasia was revealed. A rigid rhinoscopy, flexible bronchoscopy and otoscopy was used for the visualization of the lesions and tissue biopsy biopsy was performed for histopathology. On histopathological examination, the nasal mass consisted mainly of large numbers of plasma cells and lymphocytes. And the final diagnosis was lymphoplasmacytic rhinitis based on histopathologic examination. Long term management with oral cyclosporine (5 mg/kg, BID) was safe and successful in this cat. This is the first case report described clinical and diagnostic characteristic features of feline lymphoplasmacytic rhinitis and its clinical outcome using oral cyclosporine in Korea.

A STUDY ON CHANGES OF AIRWAY, TONGUE, AND HYOID POSIT10N FOLLOWING ORTHOGNATHIC SURGERY (하악후방이동수술후 기도, 혀 및 설골의 위치변화에 관한 연구)

  • Chung, Dong-Hee;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.28 no.4 s.69
    • /
    • pp.487-498
    • /
    • 1998
  • This study was conducted to investigate changes of airway size, tongue and hyoid position following orthognathic surgery in mandibular prognathism, and how they are adapted to new environment in time dependent manner. 37 patients, who had recieved orthognathic surgery, were selected for this study. lateral cephalogram of each patient was taken at preoperation, immediate postoperation, and over 6 month after operation, and were traced and analyzed The findings of this study were as follows : 1. The size of airway was not changed at PNS and Epiglottis level after operation, but it was changed slightly at 2nd cervical vertebra level. 2. The hyoid was moved inferoposteriorly at immediate postoperation, and then it shifted toward preoperative position, but it remained slightly inferoposterior position. The distance from hyoid to genial tubercle decreased continuously. 3. The position of tongue was moved inferoposteriorly at immediate postoperatioa and then it shifted toward preoperation position, but the root of the tongue remained inferoposteriorly. 4. The distance between tongue and hyoid was increased at immediate postoperation and slightly decreased during follow-up period. 5. The change of the mandibular position was not significantly correlated with changes of airway size, hyoid position, tongue morphology and tongue position.

  • PDF

The Effect of Mandibular Protrusion on Dynamic Changes in Oropharyngeal Caliber (하악의 전방이동이 구인두 내경의 동적 변화에 미치는 영향)

  • Jung, Jae-Kwang;Hur, Yun-Kyung;Choi, Jae-Kap
    • Journal of Oral Medicine and Pain
    • /
    • v.35 no.3
    • /
    • pp.193-202
    • /
    • 2010
  • The purpose of this study was to determine the sites of narrowing/obstruction and to measure the regional severity of narrowing through the evaluation of dynamic changes in upper-airway of healthy subjects. The selected 9 subjects were proved not to have any sleep-related disorder such as snoring or obstructive sleep apnea through clinical examination, radiological examination, sleep study with a portable recording system. Afterward, the Electron Beam Tomography was performed during the waking and sleeping state of subjects, with their mandible in resting and protruded position. Intravenous injection of Dormicum$^{(R)}$ was used for the induction of sleep. The maximum and minimum cross-sectional areas at each airway level during tidal ventilation were measured and the Collapsibility Index for each level of cross-section was also computed. In a comparison with results under variable conditions, the result was showed that the significant difference between each airway level divided with upper, middle, lower region of upper airway is not observed in the average minimum cross-sectional areas and Collapsibility Index. The significant difference only between in wake and sleep state was observed in the average minimum cross-sectional area at the lower region. Also, in wake state, the significant difference between resting and protrusive position of mandible for the average minimum was also observed in cross-sectional area at middle region. In sleep state, no significant difference between resting and protrusive position of mandible was observed in cross-sectional area and the Collapsibility Index.

Effect of head positioning on the vertical and horizontal magnification in panoramic radiographs: rotation along the sagittal and transverse plane (파노라마방사선사진에서 환자의 머리 위치가 하악 수직, 수평 확대율에 미치는 영향: 상하 및 좌우회전)

  • Kim, Yong-Gun;Byun, Jin-Seok;An, Seo-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.1-8
    • /
    • 2014
  • Purpose: The purpose of this study was to investigate the effect of head position changes on vertical and horizontal magnification in dental panoramic radiographs. Materials and Methods: Five 4 mm metal balls were placed above alveolar crest of dry skull considering extraction socket and dental arch. Panoramic radiographs were taken by OP-100D (Instrumentarium Imaging Co., Tuusula, Finland) at proper and rotated head position along the sagittal and transverse axis at 3 - $20^{\circ}$ upwardly, downwardly, to the left and to the right rotation. Images were stored in DICOM files and were measured by ruler equipped within INFINITT PACS software. Results: The mean horizontal magnification was $1.22{\pm}0.01-1.44{\pm}0.01$ and mean vertical magnification was $1.29{\pm}0.00-1.35{\pm}0.02$ at standard head position. There was statistical significance of horizontal magnification between the anterior ($1.24{\pm}0.02-1.31{\pm}0.03$) and the posterior area ($1.40{\pm}0.03-1.33{\pm}0.02$) (P < 0.05). Vertical magnification resulted in less variation ($1.24{\pm}0.01-1.37{\pm}0.02$) than horizontal magnification ($0.88{\pm}0.03-3.73{\pm}0.16$) according to the rotation. There was statistical significant difference on horizontal magnification (P < 0.05). Conclusion: In rotated head position, the horizontal magnification should be considered because these can cause distortion on panoramic radiographs.

The Influence of Microwave Sintering Process on the Adaptation of CAD/CAM Zirconia Core (마이크로 웨이브 소결 과정이 CAD/CAM 지르코니아 코아의 적합도에 미치는 영향)

  • Kim, Keun Bae;Kim, Jee Hwan;Lee, Keun-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.95-107
    • /
    • 2009
  • The purpose of this research was to examine the fitness of zirconia cores that were made by different sintering methods; generic electricity furnace and microwave furnace. Firstly, 12 cores for each group were made by using each different sintering process and attached them to a metal die with silicon. The internal and marginal gap of sintered zirconia was measured by using Skyscan 1076 micro-CT, then it was reorganized by CT-An software. To each samples, we extracted B-L image, M-D image of cutting side, and cross-sectional side of tooth long axis and calculated the mean value of marginal, axial, and occlusal gap each side. Results: 1. The mean marginal gap of sintered zirconia was $36.20{\mu}m$ for EVE, $47.67{\mu}m$ for LAV, $52.47{\mu}m$ for DEN, and $54.63{\mu}m$ for CER. 2. For the axial wall, the research showed the largest value of $63.49{\mu}m$ for EVE, but there were no statistical significance. 3. In related to the occlusal internal measurement, DEN showed the smallest value ($77.06{\mu}m$), EVE and CER showed significantly high value. From this study, it is suggested that CAD/CAM zirconia core which was made in the process of microwave sintering has clinically acceptable values in marginal and internal gap.

Effect of Head Positioning in Panoramic Radiography on the Vertical and Horizontal Magnification : Displacement along the Sagittal and Transverse Plane (파노라마방사선사진에서 환자의 머리 위치가 하악 수직, 수평 확대율에 미치는 영향 : 전후방 및 좌우 이동)

  • Kim, Yong-Gun;Lee, Young-Kyun;An, Seo-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.249-258
    • /
    • 2013
  • The purpose of this study was to investigate how image magnification in dental panoramic radiography is influenced by object position. Five metal balls (4 mm in diameter, 2 for the anterior and 3 for the posterior region on the right side) were placed above alveolar crest of dry skull considering extraction socket and dental arch. Dry skull was radiographed using OP-100D (Instrumentarium Imaging Co., Tuusula, Finland) at proper and displaced position along the sagittal and transverse plane at 3 mm, 6 mm, 9 mm, 12 mm and 15 mm using special mount which can control precise movement. Images were stored in DICOM files and were measured by ruler equipped within INFINITT PACS software (Infinitt Co., Ltd., Seoul, Korea). The mean horizontal magnification was 1.224-1.439 and mean vertical magnification was 1.286 - 1.345 at proper position. Vertical magnification resulted in less variation (1.245-1.418) than horizontal magnification (0.798-6.297) according to the sagittal and transverse displacements. Head positioning is important for linear measurement on panoramic radiography and inclusion of standard object (for instance, metal ball) is helpful to anticipate exact magnification of panoramic radiographs at various location.