• Title/Summary/Keyword: 구강근

Search Result 302, Processing Time 0.034 seconds

EVALUATION OF GINGIVAL CONDITION ON CHILDREN USING PERIOTRON (Periotron을 이용한 소아 치은 상태의 평가)

  • Shin, Jeong-Geun;Kim, Jae-Gon;Yang, Yeon-Mi;Kim, Sung-Hee;Baik, Byeong-Ju
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.3
    • /
    • pp.411-421
    • /
    • 2006
  • In children, during developing occlusion stage, many studies confirm a high prevalence of gingival inflammation. Prevention, early diagnosis and treatment of gingival and periodontal disease is important because by establishing excellent oral hygiene habits in children, the risk of periodontal disease can be on the decrease in adulthood. This study evaluated the gingival conditions of 50 children$(8.5{\pm}3.1years)$ and 20 $adults(26.1{\pm}3.3 years)$ receiving clinical examination and GCF test at the pediatric dentistry of Chonbuk national university hospital in Jeonju, Korea. I estimated children's and adult's gingival states by measuring gingival crevicular fluid(GCF) using Periopaper and $Periotron^{(R)}$ 8000, gingival index, plaque index, DMFT scale. The results were as follows : 1. There are no statistical differences of GCF volume among the groups of the primary dentition, tooth erupting stage, complete eruption stage(p>0.1). But mean value of GCF is highest at the tooth erupting stage. 2. Comparing with adults, children have higher mean value of GCF volume with statistical differences (p<0.001). 3. There is statistically positive relationship between volume of GCF and gingival index (GI), plaque index(PLI) in both adults and children(GI; r=0.394, PLI ; r= 0.642). 4. There is no relationship between GCF volume and dental caries, composite resin treatments (p>0.05). But There is statistically positive relationship between GCF and orthodontic treatments(p<0.001) 5. Primary dentition has higher mean value of DMFT than permanent dentition(p<0.001). But there is no statistical relationship between GCF and DMFT (p>0.1).

  • PDF

A Study on Shear Bond Strength of Core-veneer Interface for Bilayered all Ceramics (Bilayered all Ceramics에서 Core와 Veneer 계면의 전단결합강도에 관한 연구)

  • Jung, Yong-Su;Lee, Jin-Han;Lee, Jae-In;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.3
    • /
    • pp.231-242
    • /
    • 2008
  • Purpose: The purpose of this study was to investigate the bond strength of the core-veneer interface in all ceramic systems. Material and Methods: The all ceramic systems tested with their respective veneer were IPS Empress 2 with IPS Eris, IPS e.max Press with IPS e.max Ceram and IPS-e.max ZirCAD with IPS e.max Ceram. Cores (N=36, N=12/group, diameter: 10mm, thickness: 3mm) were fabricated according to the manufacturer's instruction and cleaned with ultrasonic cleaner. The veneer(diameter: 3mm, thickness: 2mm) were condensed in stainless steel mold and fired on to the core materials. After firing, they were again ultrasonically cleaned and embedded in acrylic resin. The specimens were stored in distilled water at $37^{\circ}C$ for 1 week. The specimens were placed in a mounting jig and subjected to shear force in a universal testing machine(Z020, Zwick, Germany). Load was applied at close to the core-veneer interface as possible with crosshead speed of 1.00mm/min until failure. Average shear bond strengths(MPa) were analyzed with a one-way analysis of variance and the Tukey test(${\alpha}=.05$). The failed specimens were examinated by scanning electron microscopy(JSM-6360, JEOL, Japan). The pattern of failure was classified as cohesive in core, cohesive in veneer, mixed or adhesive. Results: The mean shear bond strength($MPa{\pm}SD$) were IPS e.max Press $32.85{\pm}6.75MPa$, IPS Empress 2 $29.30{\pm}6.51MPa$, IPS e.max ZirCAD $28.10{\pm}4.28MPa$. IPS Empress 2, IPS e.max Press, IPS e.max ZirCAD were not significantly different from each others. Scanning electron microscopy examination revealed that adhesive failure did not occur in any all ceramic systems. IPS Empress 2 and IPS e.max Press exhibited cohesive failure in both the core and the veneer. IPS e.max ZirCAD exhibited cohesive failure in veneer and mixed failure.

Development of Prevotella nigrescens ATCC $33563^T$-Specific PCR Primers (Prevotella nigrescens ATCC $33563^T$ 균주-특이 중합효소연쇄반응 프라이머 개발)

  • Song, Soo-Keun;Yoo, So-Young;Kim, Mi-Kwang;Kim, Hwa-Sook;Lim, Sun-A;Kim, Do-Kyung;Park, Jae-Yoon;Kook, Joong-Ki
    • Korean Journal of Microbiology
    • /
    • v.44 no.3
    • /
    • pp.212-220
    • /
    • 2008
  • A Pn10 DNA probe was introduced as a Prevotella nigrescens ATCC $33563^T$-specific DNA probe. In that study, the specificity of the Pn10 was tested with only type or reference strains of 5 oral bacterial species. The purpose of this study is to evaluate the specificity of the Pn10 using the wild type strains of P. nigrescens and is to develop the P. nigrescens ATCC $33563^T$-specific PCR primers based on the nucleotide sequence of the Pn10. The specificity of the Pn10 DNA probe was determined by Southern blot analysis. The nucleotide sequence of Pn10 DNA probes was determined by chain termination method. The PCR primers were designed based on the nucleotide sequence of cloned DNA fragment. The data showed that Pn10 DNA probe were hybridized with the genomic DNAs from P. nigrescens ATCC $33563^T$ and KB6. The Pn10 homologous region, KB6-Pn10, of P. nigrescens KB6 was cloned by PCR and sequenced. The Pn10 and KB6-Pn10 DNA fragments were consisted of 1,875 bp and 1,873 bp, respectively. The percent identity of the two was 98.8% and the divergence of them was 0.6%. The two primer sets (Pn10-F-AC/ Pn10-R-AC and Pn10-F-A/ Pn10-R-A), designed base on the nucleotide sequences of Pn10 DNA probe, were specific to the P. nigrescens ATCC $33563^T$. The two PCR primer sets could detect as little as 4 pg of genomic DNA of P. nigrescens ATCC $33563^T$. These results indicate that the two PCR primer sets have proven useful for the identification of P. nigrescens ATCC $33563^T$, especially with regard to the maintenance of the strain.

Prevalence and Treatment Pattern of Korean Patients with Temporomandibular Disorders (한국인 턱관절장애 환자의 유병률과 진료 양태)

  • Yang, Hee-Young;Kim, Mee-Eun
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.1
    • /
    • pp.63-79
    • /
    • 2009
  • While previous epidemiological studies on temporomandibular disorders (TMD) have been based on a given health center or population sample, no study has been performed on general population of Korea, especially concerning about treatment pattern such as clinician’s specialty involved in TMD treatment, types and amount of prescription medication and cost. This study aimed to investigate magnitude of health visits and treatment patterns for Korean patients with TMD through the computerized database of Health Insurance Review and Assessment Service (HIRAS). Inclusion criteria were all patients registered on the HIRAS database over 3 years' period from 2003 to 2005 and the medical records of patients with TMD as a main diagnosis were extracted. Information collected was as follows; distribution related to gender, age and region and type of hospital the patients visited, treatment duration, clinicians' specialty involved in treatment, cost, types of prescription medication and surgical treatment. The results of this study indicated that 0.15% of the population yearly sought TMD treatment, presenting with increase of incidence over the three years. Most of TMD patients were women (99.8%) and the biggest age group was second and third decades and decreased with age. Seoul and Kyeonggi province presented with higher incidence of TMD compared to the other regions of Korea, which seems to be related with magnitude of population. 56% of TMD patients visited primary care sector and the numbers of treatment visits was the highest in dental clinic (38.4%), followed by orthopedics (28%) and ENT (13.6%) clinics in order. Duration of prescription medication was the longest for anti-inflammatory analgesics, followed by antipsychotic drugs and muscle relaxants. Inpatient care related to TMD was primarily performed in dental hospital compared to medical hospital. Medical database of HIRAS provided comprehensive and vast information on epidemiologic characteristics and treatment patterns for patients seeking TMD treatment, which can be more reliable data to expect medical demand for TMD in condition that accurate diagnosis and standardized treatment is delivered in clinical settings.

Retention of CAD/CAM Metal Copings Cemented on Short Titanium Abutments with Different Cements (짧은 티타늄 지대주에 합착된 CAD/CAM 금속 코핑의 시멘트 종류에 따른 유지력 비교)

  • Kim, Hyo-Jung;Song, Eun-Young;Yoon, Ji-Young;Lee, Si-Ho;Lee, Yong-Keun;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.119-126
    • /
    • 2012
  • State of problem: Cement-retained implant-supported prostheses are routinely used in dentistry. The use of high strength cements has become more popular with the increasing confidence in the stability of the implant-abutment screw connection and the high survival rates of osseointegrated implants. No clinical data on retention of metal copings using CAD/CAM. To evaluate retention of metal copings using CAD/CAM system bonded to short titanium abutment with four different cements and compare retentive strength of metal copings with sandblasting or without sandblasting before cementation. Forty titanium abutment blocks were fabricated and divided into 4 groups of 10 samples each. Forty metal copings with occlusal hole to allow for retention testing were fabricated using CAD/CAM technology. The four cements were Fujicem(Fuji, Japan), Maxcem Elite(Kerr, USA), Panavia F2.0(Kurarary, Japan) and Superbond C&B(Sunmedical, Japan). The copings were cemented on the titanium abutment according to manufacture's recommendation. All samples were stored for 24h at 37oC in 100% humidity and tested for retention using universal testing machine(Instron) at a crosshead speed of 1.0mm/min. Force at retentive failure was recorded in Newton. The mode of failure was also recorded. Means and standard deviations of loads at failure were analyzed using ANOVA and Paired t-test. Statistical significance was set at P<0.05. Panavia F2.0 provided significantly higher retentive strength than Fujicem, Maxcem Elite(P<0.05). Sandblasting significantly increased bond strength(P<0.05). The mode of failure was cement remaining principally on metal copings. Within the limitation of this study, Panavia F2.0 showed significantly stronger retentive strength than Fujicem, Maxcem Elite(p<0.05). The Ranking order of the cements to retain the copings was Panavia F2.0, Fujicem = Maxcem Elite. Sandblasting significantly increased bond strength(P<0.05). The retentive strength of metal copings on implant abutment were influenced by surface roughness and type of cements.

The Effect of the Pain on the TMJ and Masticatory Muscles to Tension-type Headache (측두하악관절과 저작근의 통증이 긴장성 두통에 미치는 영향)

  • Kim, Jin-Suk;Auh, Q-Schick;Lee, Jin-Yong;Hong, Jung-Pyo;Chun, Yang-Hyun
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.4
    • /
    • pp.327-335
    • /
    • 2006
  • Generally, Tension-Type Headache(TTH) patients exhibit muscle pain, but can also have TMJ pain, which includes mouth opening limitation or joint sounds. The purpose of our study is to observe the clinical pain characteristics between TTH patients with muscle pain and TMJ pain. One hundred sixty-seven patients were diagnosed with TTH according to the questionnaires based on the International Headache Society's proposal on the diagnostic criteria of TTH. The patients were classified into three group; arthralgia group (18 patients), myalgia group (50 patients) and arthromyalgia group (99 patients). TTH patients with pericranial muscle pain were classified in the myalgia group. TTH patients with temporal region pain were classified in the arthralgia group. TTH patients with both types of pain were classified in the arthromyalgia group. The parameters in the diagnostic criteria such as quality, intensity, laterality of pain, and aggravation due to physical activities were compared among the three groups. 1. There were no significant differences in the quality of pain among the three groups. 2. There were no significant differences in the intensity of pain among the three groups. 3. There were no significant differences in the laterality of pain among the three groups. 4. A higher percentage of patients in the arthromyalgia group experienced headaches that were aggravated due to physical activity (p=0.03) compared to the other groups. The results of this study show that TTH patients with both arthralgia (TMJ pain) and myalgia (pericranial muscle pain) are more aggravated by physical activity than TTH patients with either one.

Bite Force, Occlusal Contact Area and Occlusal Pressure of Patients with Temporomandibular Joint Internal Derangement (측두하악관절 내장증 환자의 교합력, 교합 접촉 면적 및 교합압)

  • Kim, Ki-Seo;Choi, Jong-Hoon;Kim, Seong-Taek;Kim, Chong-Youl;Ahn, Hyung-Joon
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.3
    • /
    • pp.265-274
    • /
    • 2006
  • Temporomandibular joint (TMJ) internal derangement, especially disc displacement with reduction (DDwR) is the most common TMJ arthropathy and has been thought to do some effects on masticatory performance. Measuring of maximal bite force has been widely used as objective and quantitative method of evaluating masticatory performance, but previous studies showed various results due to various characteristics of subjects and different measuring devices and techniques. In a few studies about the correlation of bite force and temporomandibular disorders (TMD), some authors reported that bite force and masticatory performance would be reduced in patients with TMD because of pain. But the correlation of changes in structure of articular disc and masticatory performance has not been well investigated yet. In this study, to investigate the influences of non-painful disc change on the masticatory performance, we measured the value of maximal bite force, occlusal contact area and occlusal pressure of 39 patients with non-painful DDwR of the TMJ using pressure sensitive film, and compared it with that of 59 controls. The results are summarized as follows: 1. The maximal bite force (P<0.01) and the occlusal contact area (P < 0.05) of the DDwR patients were greater than the controls. 2. There was no significant difference in occlusal pressure between the DDwR patients and the controls (P > 0.05). 3. The maximal bite force of the male group was greater than that of the female group (P < 0.05). However, the occlusal contact area and the occlusal pressure between the male and the female group didn't show significant difference (P > 0.05). From the results above, we can suggest that DDwR could be a factor of changing bite force, but more controlled, large scaled and EMG related further study is needed.

Fitness of Adjustable Dental Impression Trays on the Caucasian and African American (백인과 흑인에 대한 가변형 치과 인상용 트레이의 적합성에 관한 연구)

  • Park, Yong-Suck;Kim, Yu-Lee;Oh, Sang-Cheon;Lee, In-Seop;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.185-192
    • /
    • 2008
  • Purpose: This study was designed to investigate the fitness of adjustable dental impression trays on the Caucasian and African American. Material and methods: The size and shape of these trays were designed from the results of the dental arch size of Korean adults. Tray samples were made by CAD-CAM working. Sixty Caucasian (male:30, female:30) and sixty African American (male:30, female:30) were selected for taking irreversible hydrocolloid impression using these trays. The author measured the width and length of impression material on the several measuring points. Results: 1. Uniform impression material width was achieved by controling the width of the tray using stops and beveled guides. 2. In the maxillary tray on the Caucasian, the impression material thickness was measured to be rather great showing thickness of the midpalatal part 13.0 mm. 3. In the maxillary tray on the African American, the impression material thickness was measured to be rather great showing thickness of the midpalatal part 12.0 mm, posterior palatal part 11.0 mm and the labial frenum width was 11.0 mm. 4. In the maxillary tray on the African American, the impression material width of posterior border (0.8 mm) was measured to be small. 5. In the mandibular tray on the Caucasian, the impression material width was measured (2.7-6.7 mm) and posterior border width (2.1 mm) was measured small. The impression material length was measured (2.8-6.7 mm). 6. In the mandibular tray on the African American, the impression material width was measured to be rather great showing width of the labial frenum 9.2 mm and the width of posterior border was measured too small (0.3 mm). Conclusion: This adjustable dental tray shows good accuracy to Korean because it was designed by the analysis of the dental arch size of Korean adult model. With this result, it can be applied to Caucasian and African American, we can take more easy and accurate dental impressions.

A Study on Morphology and Size of Clinical Crown of Permanent Maxillary Molar in Korean Adult (한국 성인의 상악 대구치 임상치관의 형태와 크기에 관한 연구)

  • Cha, Kwon-Sil;Oh, Sang-Chun;Dong, Jin-Keum
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.2
    • /
    • pp.79-92
    • /
    • 2000
  • The purpose of this study was to estimate the morphology and the size of permanent maxillary molar in Korean Adult. The 100 dental college students with a normal dentition and without any dental prosthesis and severe caries were selected for this study. The subjects were taken impression to make study model. On the study model, authour three times measured those sizes and estimated morphological structures with a calipers, a Boley gauge and a protractor. The results were as follows; 1. In the maxilary first molar's clinical crown height, mesiolingual cusp height was 6.34mm, mesiobuccal cusp height was 6.05mm, distobuccal cusp height was 5.20mm. And in the maxillary second molar's clinical crown height, mesiobuccal cusp height was 5.85mm, mesiolingual cusp height was 5.71mm, distobuccal cusp height was 5.51mm, distolingual cusp height was 3.53mm. This result considered that the maxillary first molar inclined to distobuccal, and the maxillary second molar more upright than the maxillary first molar. 2. In the width of clinical crown, the maxillary first molar was 10.43mm, the maxillary second molar was 10.20mm, and the difference between the first molar's width and the second molar's width was 0.23mm. 3. The crown thickness was measured divided into mesial buccolingual half and distal buccolingual half. The mesial buccolingual half was 11.14mm, and distal buccolingual half was 10.35mm in the maxillary first molar, and in the maxilary second molar, mesial buccolingual half was 11.25mm, and distal buccolingual half was 9.72mm. This result considered that height of convergency located in mesial half of crown. 4. In the buccal groove length, total length and ratio, the maxillary first molar was 52.5%, the maxillary second molar was 50%. And the development of buccal groove in the maxillary first molar was 59% in case of the well developed buccal groove and 41% in case of the weak developed one. And frequency of buccal pit of the maxillary first molar was 12.5%. Whereas, the frequency of buccal of the well developed buccal groove in the maxillary second molar was 37% and that of the weak developed one was 63%. And frequency of buccal pit of the maxillary second molar was not seen. 5. The 3 cusp type tooth cannot be found in the maxillary first molar and the frequency of 3 cusp type tooth in the maxillary second molar was as small as 6% 6. In the case of 4 cusp type tooth, the size of distal lingual cusp molar was difference between in the maxillary first molar and in the maxillary second molar by about 1mm. 7. The intercuspal distance was similar in the maxillary first premolar and second molar. And intercuspal distanc of mesial half of the maxillary first molar and the maxillary second molar was silmillar, too. 8. The an measurement of occlusal surface in 4 cusp type tooth showed that the angle of occlusal surface between the distobuccal and mesiolingual was an obtuse angle, and the angle of occlusal surface between mesiobuccal and distolingual was an acute angle in the both cases of maxillary first and second molar. 9. The measurements of the development of Carabelli cusp showed that the frequency of the well developed one was 7% and that of the weak developed one was 56% in the maxillary first molar. And there cannot be found the well developed one and can be found 2.5% only in the case of the weak developed one in the maxillary second molar. 10. The well developed oblique ridge in the maxillary first molar showed the 100% frequency and that in the maxillary second molar showed the 85.5% frequency. The frequency of mesiomarginal ridge tubercle in the maxillary first molar was 82% and that in the maxillary second molar was 30.5%. And the frequency of distal accessory tubercle in the maxillary first molar can be seen about 19% and that in the maxillary second molar can be seen about 12%.

  • PDF

Preliminary Results of Phase I/II Study of Simultaneous Modulated Accelerated (SMART) for Nasopharyngeal Carcinoma (비인강암의 치료에서 동시차등조사가속치료를 적용한 제1상/2상 연구의 예비적 결과)

  • Park Jin-Hong;Back Geum-Mun;Yi Byong-Yong;Choi Eun-Kyung;Ahn Seung-Do;Shin Seong-Soo;Kim Jung-Hun;Kim Sang-Yoon;Lee Bong-Jae;Nam Soon-Yuhl;Choi Seung-Ho;Kim Seung-Bae;Lee Sang-Wook
    • Radiation Oncology Journal
    • /
    • v.24 no.1
    • /
    • pp.1-10
    • /
    • 2006
  • Puroose: To present preliminary results of intensity-modulated radiotherapy (IMRT) using the simultaneous modulated accelerated radiation therapy (SMART) boost technique in patients with nasopharyngeal carcinoma (NPC). Materials and Methods: Twenty patients who underwent IMRT for non-metastatic NPC at the Asan Medical Center between September 2001 and December 2003 were prospectively evaluated. IMRT was delivered using the 'step and shoot' SMART technique at prescribed doses of 72 Gy (2.4 Gy/day) to the gross tumor volume (GTV), 60 Gy (2 Gy/day) to the clinical target volume (CTV) and metastatic nodal station, and 46 Gy (2 Gy/day) to the clinically negative neck region. Eighteen patients also received concurrent chemotherapy using cisplatin once per week. Results: The median follow-up period was 27 months. Nineteen patients completed the treatment without interruption; the remaining patient interrupted treatment for 2 weeks owing to severe pharyngitis and malnutrition. Five patients (25%) had RTOG grade 3 mucositis, whereas nine (45%) had grade 3 pharyngitis. Seven patients (35%) lost more than 10% of their pretreatment weight, whereas 11 (55%) required intravenous fluids and/or tube feeding. There was no grade 3 or 4 chronic xerostomia. All patients showed complete response. Two patients had distant metastases and loco-regional recurrence, respectively. Conclusion: IMRT using the SMART boost technique allows parotid sparing, as shown clinically and by dosimetry, and may also be more effective biologically. A larger population of patients and a longer follow-up period are needed to evaluate ultimate tumor control and late toxicity.