• 제목/요약/키워드: 교정 계수

검색결과 185건 처리시간 0.063초

Air Density Correction of Ionization Chamber using $^{90}Sr$ Radioactive Check Device ($^{90}Sr$ 방사성 동위원소를 이용한 전리함의 대기 보정계수 측정)

  • Park, Sung-Y.;Kim, Woo-C.;Shin, Dong-O.;Ji, Young-H.;Kwon, Soo-I.;Lee, Kil-D.;Cho, Young-K.;Loh, John-J.
    • Journal of Radiation Protection and Research
    • /
    • 제23권4호
    • /
    • pp.267-271
    • /
    • 1998
  • It is required to measure air density correction factor at the time of absorbed dose calibration or measurement. In general, thermometer and barometer are widely used for air density correction. However, this can be done using the radioactive check device with better accuracy. The measurements of air density correction were performed by using the radioactive check device, Unidos electrometer, and 0.6 cc Farmer-type ion chamber of PTW under the different environmental conditions. Above experiments were repeated with thermometer and barometer. By comparing the two methods, they were within the difference of 0.2 %. The overall uncertainty for the dose found in thermometer and barometer was 1.2 - 1.6 %, depending upon either one step or two, whereas the overall uncertainty for the radioactive check device was 1.02 %. This method may reduce the possible error which could occur when thermometer and barometer are not calibrated at regular basis.

  • PDF

Measurement of Stress Intensity Factor of Orthotropic Material Using SPATE (SPATE에 의한 직교이방성체의 응력확대계수 측정)

  • Hwang, Jae-Seok;Suh, Jae-Guk;Lee, Hyo-Jae;Nam, Jeong-Hwan;Rpwlands, R.E.
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제20권10호
    • /
    • pp.3224-3233
    • /
    • 1996
  • SPATE(Stress Pattern Analysis by Thermal Emission) can be effectively used to analyze the stress distribution of the orthotropic structure under the repeated load by non-contact. In this research, the measuring conception and method of stress intensity factor of orthotropic material using SPATE are suggested. The relationships between the maximum values of SPATE signal and $1/\sqrt{X'}$ (or $1/\sqrt{y'}$) are theoretically established in the vicinity of crack tip of the orthotropic material. It is certified through SPATE experiment that their linear quality is very excellent.

A Study on the Guided Wave Mode Conversion using Self-calibrating Technique (자가교정기법에 의한 유도초음파 모드전이에 관한 연구)

  • Park, Jung-Chul;Cho, Youn-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • 제20권3호
    • /
    • pp.206-212
    • /
    • 2000
  • The guided wave mode conversion phenomena were investigated for the NDE of a plate-like structure with thickness variation. The ratios of reflection and transmission (R/T) were measured via the self-calibrating procedure which allows us to obtain experimental guided wave data in a more reliable way regardless of the coupling uncertainty between transducer & specimen. The results on R/T could be used to determine the thickness reduction of the structure. It was shown that not only the incident modes but also the converted ones need to be considered in the self-calibrating guided wave inspection to extract a reasonable correlation between experimental data & the thickness variation. Through this study, the potential of guided wave inspection as a quantitative NDE technique was explored based on the combined concept of self-calibration & multi-mode conversion in guided wave scattering problems.

  • PDF

Comparison on Accommodative Response Changes in the Normal Group and Convergence Insufficiency (정상군과 폭주부족군에서 조절반응 변화량의 비교)

  • Kwak, Ho-Weon;Lee, Se-Hee;Kwak, Hyung-Bin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • 제19권1호
    • /
    • pp.79-85
    • /
    • 2014
  • Purpose: This study investigated accommodative changes by measuring accommodative response, appearing on the normal and convergence insufficiency Group, by using both eyes open-view auto-refractometer (Nvision-K5001, shin-nippon, Japan). Methods: It carried out objective and subjective refractions, targeting 74 college students (54 males and 20 females) aged between 19 and 29 ($21.59{\pm}2.53$), spherical equivalent OD $-2.28{\pm}2.03$ D, OS $-2.18{\pm}2.01$ D, by measuring accommodative responses at full correction and under correction with plus lens +0.25, +0.50, +0.75 arbitrarily added. Results: In the group of normal and convergence insufficiency, the shorter fixation distances were, the greater accommodative lags showed. The group of convergence insufficiency showed the lesser changes of accommodative response than those of normal. But we found that the convergence insufficiency group had a little larger accommodative amplitude in the total fixation distances. The full correction of convergence insufficiency group and the under correction (+0.50 D) of normal were alike in the accommodative responses. We have also investigated that the correlation between accommodative responses and fixation distances was decreased steeply at the excessive low vision correction. Conclusions: Under correction (+0.50 D) in a near distance is expected to avoid unnecessary accommodative responses, make eyes relaxed and comfortable.

A STUDY ON THE CHANCES OF THE SOFT TISSUE PROFILE FOLLOWING ORTHODONTIC TREATMENT BY DIGITAL SUBTRACTION METHOD (교정치료에 따른 측모 연조직의 변화에 관한 계수공제 영상측정법적 연구)

  • Cho, Won-Tak;Yu, Dong-Hwan
    • The korean journal of orthodontics
    • /
    • 제27권3호
    • /
    • pp.411-420
    • /
    • 1997
  • The propose of this study was to quantify the changes of soft tissue profile following orthodontic treatment and to evaluate the relationship of those to the skeletal elements. Pre-and post-treatment lateral cephalometric head films of 40 cases(20 extraction cases, 20 non-extraction cases) were traced, and the changes following treatment were measured and quantified by digital subtraction method, and statisticall analyzed. The obtained results were as follows; 1. in extraction group, the change of upper lip area(UL) was $558.60\pm355.17$ pixels, that of lower lip area(LL) was $941.15\pm364.07$ pixels. But, in non-extraction group the change of uper lip area(UL) was $125.65\pm404.16$ pixels, that of lower lip area(LL) was $104.05\pm440.93$ pixels, which was significantly lesser than those in extraction group. 2. In extraction group, there was significant correlationship between upper lip area change(UL) and difference of upper incisor point(${\Delta}UIP$). Lower lip area change(LL) was significantly correlated with difference of upper incisor(${\Delta}UIP$), difference of Franlrfort upper incisor angle(${\Delta}FUIA$) or difference of interincisal angle(${\Delta}IIA$). 3. In extraction group, the ratio of difference of upper incisor point(${\Delta}UIP$) to difference of labrale superius(${\Delta}LSP$) was 1.68; difference of lower incisor point(${\Delta}LIP$) to difference of labrale inferius(${\Delta}LI$) was 1.19; difference of upper incisor point(${\Delta}UIP$) to increment in upper lip thickness(${\Delta}TUL$) was 1.95. 4. In non-extraction group, there was a significant correlationship between upper lip area change(UL) and difference of upper incisor point(${\Delta}UIP$).

  • PDF

Thermopile Radiometer Calibration Using Reference Instrument (표준준기에 의한 일사계 교정)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Young-Heak
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.199.2-199.2
    • /
    • 2010
  • The main purpose of the calibration procedure is to perform a one to one comparison of the reference pyranometer and the test pyranometer. In order to achieve this, both pyranometers need to be exposed to exactly the same irradiance, under the same circumstances. There are a number of error sources that could result in a wrong measurement. Most importantly Lamp instability, pyranometer offsets, thermal offsets of junctions, voltmeter offset, voltmeter instability, reference pyranometer instability, tilting of the pyranometers and differences in sensor height. Another sun-disc calibration procedure compares the computed vertical component of the direct irradiance as measured by a pyranometer with that measured by the pyranometer to be calibrated. Readings are taken with the levelled pyranometer on a clear day. Firstly the global irradiance and then the diffuse component are measured. Simultaneously measurement of direct irradiance is made with the pyrheliometer. The ways of performing the calibration and the subsequent calculation have been chosen such that the effect all these error sources has been eliminated as much as possible.

  • PDF

Solar Radiation Measurement and Data Quality Management (태양자원 측정 및 데이터 품질관리)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Young-Heak
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.63.2-63.2
    • /
    • 2010
  • Solar radiation data are used in several forms and for a variety of purposes. The most detailed information we have is beam and diffuse solar radiation on a horizontal surface, by hours, which is useful in simulations of solar processes. Daily data are more often available and monthly total solar radiation on horizontal surface can be used in some process design methods. However, as performance is generally not linear with solar radiation, the use of average may lead to serious errors if non-linearities ara not taken into account. It is also possible to reduce radiation data to more manageable forms by statistical methods. The control of the quality of most measurements is relegated to the control of the measuring instruments and measuring processes themselves. An accurate measurement will usually result from the use of a high-quality instrument that has been accurately calibrated and is properly used by a qualified individual.

  • PDF

Site Calibration for the Wind Turbine Performance Evaluation (풍력발전기 성능실증을 위한 단지교정 방법)

  • Nam, Yoon-Su;Yoo, Neung-Soo;Lee, Jung-Wan
    • Journal of Industrial Technology
    • /
    • 제22권A호
    • /
    • pp.49-57
    • /
    • 2002
  • The accurate wind speed information at the hub height of a wind turbine is very essential to the exact estimation of the wind turbine power performance testing. Several methods on the site calibration, which is a technique to estimate the wind speed at the wind turbine's hub height based on the measured wind data using a reference meteorological mast, are introduced. A site calibration result and the wind resource assessment for the Taekwanryung test site are presented using a one-month wind data from a reference meteorological mast and a temporal mast installed at the site of wind turbine. From this analysis, it turns out that the current location of the reference meteorological mast is wrongly determined, and the self-developed codes for the site calibration are working properly. Besides, an analysis on the uncertainty allocation for the wind speed correction using site calibration is performed.

  • PDF

Comparison of Bin Averaging Method and Least Square Method for Site Calibration (단지교정을 위한 빈평균방법과 최소자승법의 비교)

  • Yoo, Neung-Soo;Nam, Yun-Su;Lee, Jeong-Wan;Lee, Myeong-Jae
    • Journal of Industrial Technology
    • /
    • 제25권B호
    • /
    • pp.157-164
    • /
    • 2005
  • Two methods, the bin averaging method and least square method, are often used in calibrating wind turbine test sites. The objective of this work was to determine a better method to predict the wind speed at wind turbine installing point. The calibration was done at the test site on a complex terrain located in Daegwallyeong, Korea. It was performed for two different cases based on the IEC 61400-12 power performance measurement standard. The wind speeds averaged for 10 minutes ranged between 4 m/s and 16 m/s. The wind-direction bins of each meteorological mast were 10 degrees apart, and only the bins having data measured for more than 24 hours were employed for the test site calibration. For both cases, the two methods were found to yield almost same results which estimated real wind speed very closely.

  • PDF

Surfactant Sorption Effects on the Removal of Hydrophobic Organic Compounds (HOCs) from Subsurface (토양/지하수내 난분해성 유기오염물 제거시 계면활성제 흡착 영향)

  • 고석오
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 한국지하수토양환경학회 1998년도 공동 심포지엄 및 추계학술발표회
    • /
    • pp.64-68
    • /
    • 1998
  • 본 연구는 오염토양/지하수의 정화를 위하여 사용되는 계면활성제 교정기술의 보다 현실적인 평가를 위하여 토양에 흡착된 계면활성제에 대한 소수성 유기오염물인 Naphthalene과 Phenanthrene의 흡수현상에 대한 연구결과를 나타내었다. 음이온 계면활성제인 Sodium Dodecyl Sulfate (SDS)와 중성 계면활성제인 Tween 80의 흡착곡선은 소수성 꼬리 (hydrophobic tails)간의 상호작용에 의하여 S-형 모양을 보이며 이들 흡착된 계면활성제는 Micelle로 존재하는 계면활성제에 비하여 유기오염물에 대한 보다 강한 흡수능력을 나타내었다. 결과에 나타난 흡수능력의 차이는 계면활성제가 흡착되어있거나 Micelle상태로 존재할 경우 다른 구조를 형성하기 때문이라 사료된다. 흡수된 계면활성제와 Micelle의 상호경쟁에 의하여 유기오염물의 부동성(immobility)을 나타내는 분배계수(distribution coefficient)는 계면활성제의 농도에 반비례하였다. 결론적으로 토양/지하수의 오염물 정화를 위하여 계면활성제 교정기술의 적용 시 고정상 (solid phase)에 있는 흡착 계면활성제에 의한 유기오염물의 지체현상 (retardation)을 고려하여야 한다.

  • PDF