• Title/Summary/Keyword: 교정가속시험

Search Result 10, Processing Time 0.018 seconds

Lifetime Estimation of an Axle Drive Shaft by Calibrated Accelerated Life Test Method (CALT 방법을 이용한 액슬구동축의 수명 예측)

  • Kim, Do-Sik;Kim, Hyoung-Eui;Yoon, Sung-Han;Kang, E-Sok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.3
    • /
    • pp.273-281
    • /
    • 2010
  • In this paper, a method to predict the fatigue life of an axle drive shaft by the calibrated accelerated life test (CALT) method is proposed. The CALT method is very effective for predicting lifetimes, significantly reducing test time, and quantifying reliability. The fatigue test is performed by considering two high stress and one low stress levels, and the lifetime at the normal stress level is predicted by extrapolation. In addition, in this study, the major reliability parameters such as the lifetime, accelerated power index, shape parameter, and scale parameter are determined by conducting various experiments. The lifetime prediction of the axle drive shaft is verified by comparing the experimental results with load spectrum data. The results confirm that the CALT method is effective for lifetime prediction and requires a short test time.

Accelerated Life Evaluation of Drive Shaft Using Vehicle Load Spectrum Modeling (차량 부하 스펙트럼 모델링을 이용한 구동축의 가속 수명 평가)

  • Kim, Do Sik;Lee, Geun Ho;Kang, E-Sok
    • Transactions of the KSME C: Technology and Education
    • /
    • v.5 no.2
    • /
    • pp.115-126
    • /
    • 2017
  • This paper proposes an accelerated life evaluation of drive shaft for the power train parts of special purpose vehicle. It is necessary the real load data of usage level driving load condition for life evaluation of power train parts, but we can't get the load spectrum data for evaluation in many case of special purpose vehicle. So, in this paper, the road load spectrum data for evaluation is created by modeling and simulation based on vehicle data and special road condition. The inverse power model is used for accelerated life test. The equivalent torque of load spectrum is achieved using the Miner's Rule. This paper also proposes the calibrated acceleration life test method for drive shaft. The fatigue test is performed through three stress levels. The lifetime at normal stress level is predicted by extrapolation, and is verified through comparison of experimental results and load spectrum data.

Accelerated Life Evaluation of Propeller Shaft for Forklift Truck (지게차용 추진축의 가속 수명 평가)

  • Kim, Do-Sik;Sung, Baek-Ju
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.11
    • /
    • pp.1221-1229
    • /
    • 2014
  • This paper proposes an approach for predicting the fatigue life of a propeller shaft of a forklift truck by an accelerated life test method. The accelerated life test method adopted in this study is the calibrated accelerated life test, which is highly effective in the prediction of the lifetime and enables significant reduction of the test time as well as a quantification of reliability in the case of small sample sizes. First, the fatigue test was performed under two high stress levels, and then, it was performed by setting low stress levels in consideration of the available test time and extrapolation. Major reliability parameters such as the lifetime, accelerated power index, and shape parameter were obtained experimentally, and the experimentally predicted lifetime of the propeller shaft was verified through comparison with results of an analysis of load spectrum data under actual operating conditions.

관성센서 출력 측정을 위한 AF 변환기 교정기법

  • Kim, Jeong-Yong;Cho, Hyun-Chul;Roh, Woong-Rae;Choi, Hyung-Don;Cho, Gwang-Rae
    • Aerospace Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.117-125
    • /
    • 2005
  • Generally, the inertial navigation and guidance unit uses AF(Analog-to-Frequency) converters which convert analog signals into frequency signals to enhance a measurement accuracy of gyroscope and accelerometer outputs. The confidence level of AF converter is guaranteed by a prudential decision of calibration procedure and a performance of periodic calibration test. In this paper, we focus on the synchronous charge balance type AF converter which has a separate positive or negative current input and its calibration method is described. The calibration tests are classified into the scale factor error calibration and the bias calibration. These tests are automatically performed by the calibration program.

  • PDF

CANFLEX 연료봉 다발의 수중 진동특성

  • 박진석;정장환;김복득
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.921-926
    • /
    • 1998
  • CANFLEX 연료봉 다발의 3000 시간 내구성 시험 기간 동안 속도센서를 사용하여 압력관 내부에 장전된 연료봉 다발의 진동을 측정하였다. 압력관 내부에 장전된 연료봉의 진동측정은 고온, 고압, 그리고 공간적 제약 때문에 가속도계나 스트레인 게이지 같은 접촉센서로는 측정할 수 없다. 비접촉 센서를 사용하면 이러한 난점을 해결하고 압력관 내부에 장전된 연료봉 다발의 진동을 측정할 수 있다. 속도센서는 비접촉 센서로서 가우스(gauss)의 크기를 감지하여 전압을 출력하는 센서이지만, 측정거리, 주파수, 그리고 속도와 가우스가 비선형이기 때문에 교정을 한 후에 사용하여야 한다. 본 본문에는 속도센서의 교정방법과 압력관 내부에 고온, 고압의 유체가 흐를 때 발생하는 연료봉 다발의 진동특성을 구하였다.

  • PDF

Comparison the reference ion chamber in using the radioactive check source and field ion chamber for output dose for Co-60 source of remote afterloading system (시험선원을 이용한 기준 전리함의 감도변화와 임상필드전리함의 성능 안정성 비교)

  • 최태진
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.141-146
    • /
    • 2001
  • It is well known that assurance of the radiation therapy needs for an accuracy of $\pm$ 5 % in the delivery of an absorbed dose to target volume. Therefore, the dose evaluation of brachytherapy source and/or linear accelerate beam must be a stability with accuracy. In an advanced country, they recommended to use the radioactive check source for reference air ionization chamber for a stable response of radiation field chamber. In this experiments, the radioactive source Sr-90 and PR-05 air ionization chamber were used for standard source and reference ion chamber. The response of reference ion chamber showed as an 1.000$\pm$ 0.010 uncertainty for 10 years long and the evaliuation f dose discrepancy of clinical field ion chamber showed as 0.997 $\pm$0.011 in a $^{60}$ Co brachytherapy soruce. In our experiments, we can assuarance the long halflife standard source is reliable to preserve the calibration factor of reference chamber in stability.

  • PDF

Capacitive Voltage Divider for a Pulsed High-Voltage Measurement (펄스형 고전압 측정용 용량성 전압 분배기)

  • Jang, S.D.;Oh, J.S.;Son, Y.G.;Cho, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1612-1615
    • /
    • 2001
  • 포항 방사광 가속기 2.5 GeV의 전자선형 가속기는 마이크로웨이브 발생원으로써 80 MW 클라이스트론(klystron) 11대와 입사부에 65 MW 클라이스 트론 1대를 사용한다. 전자빔 에너지의 효율적인 제어를 위하여 고출력 클라이스트론의 RF 전력과 입력 빔의 전력을 정확하게 측정해야 하며 응답특성이 양호한 측정장치와 정밀한 측정이 요구된다. 클라이스트론에 공급되는 전력은 캐소드에 인가되는 전압과 전류의 측정치로 계산된다. 비록 빔 전압측정에서의 작은 오차일지라도 클라이스트론 RF 출력 전력의 결과값에 큰 영향을 미친다. 따라서, 빔 전압의 측정시에 정확한 측정을 위하여 특별한 주의가 요구된다. 고전압 펄스전원장치 인 모듈레이터 (modulator)에서 발생되는 수백 kV(350-400 kV)의 전압을 측정하기 위하여 커패시터의 용량비로 입력전압을 분압하는 용량성 분압기(capacitive voltage divider, CVD)가 사용된다. 고압측 분압용 표준 콘덴서의 정전용량을 결정하는 주요인자는 고전압 절연유의 유전율(dielectric constant)이다. 그러므로, 측정범위 내의 전압, 주파수, 온도에 대하여 정전용량의 변화율이 작도록 설계하여야 한다. 본 논문에서는 펄스형 고전압 신호 측정을 위한 용량성 전압 분배기의 측정원리, 설계분석, 교정시험, 절연유의 온도변화에 따른 정전용량 변화 특성에 대한 실험 결과를 고찰하고자 한다.

  • PDF

KS 규격 안에 따른 터보분자펌프의 성능시험

  • 박미영;인상렬
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.46-46
    • /
    • 1999
  • 터보분자펌프(turbomolecular pump, TMP)는 각종 연구장비, 반도체 제조장치, 가속기, 핵융합 실험 장치 등 여러 분야에서 가장 널리 쓰이는 고진공 펌프로서 자리잡고 있다. 이런 TMP의 광범위한 사용에도 불구하고 성능평가에 관한 통일된 규격이 마련되어 있지 않다. 국제 규격협회(ISO)의 터보분자펌프 성능평가방법 시안을 토대로 제정중인 KS 규격은 아직 실험적인 근거를 자체적으로 가지고 있지 못하므로 앞으로 각 항목들에 대한 많은 실험이 수행되어야 한다. TMP의 성능을 나타내 주는 항목들 중 배기속도(pumping speed)와 압축비(compression ratio)는 가장 중요한 것들로서 다른 고진공 펌프 및 TMP 상호간의 성능을 비교할 수 있는 기본 항목이라 할 수 있다. 본 실험에서는 종래의 단순 TMP와 큰 기체유량에서도 안정된 배기속도를 유지하는 복합터보분자펌프(compound molecular pump, CMP)의 배기속도와 압축비 및 임계배압(critical backing pressure)을 KS 규격안대로 시험 평가하여 안의 평가방법과 기준의 타당성을 검토하고, 두 가지 다른 방식의 펌프에 적용할 수 있는지를 검토하였다. TMP 및 CMP 흡기구에 표준용기를 부착하고 수소 및 질소 기체를 사용하여 흡기구 압력을 변화시키면서 배기속도 및 압축비를 측정하고 배기구 압력을 변호시키면서 최대압축비 및 임계배압을 측정하였다. 흡기구의 압력측정에는 인출형 전리진공계(EG)를 사용하였고, 배기구의 압력측정은 전기용량의 격막진공계(CDG)와 피라니 진공계로 측정하였다. 진공계는 모두 회전식 점성진공계(SRG)로 교정한 후 사용하였다.

  • PDF

Investigation of Response of Several Neutron Surveymeters by a DT Neutron Generator (DT 중성자 발생기에 의한 중성자 검출기 반응도 조사)

  • Kim, Sang-In;Jang, In-Su;Kim, Jang-Lyul;Lee, Jung-Il;Kim, Bong-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.1
    • /
    • pp.35-40
    • /
    • 2012
  • Several neutron measuring devices were tested under the neutron fields characterized with two distinct kinds of thermal and fast neutron spectrum. These neutron fields were constructed by the mixing of both thermal neutron fields and fast neutron fields. The thermal neutron field was constructed using by a graphite pile with eight AmBe neutron sources. The fast neutron field of 14 MeV was made by a DT neutron generator. In order to change the fraction of fast neutron fluence rate in each neutron fields, a neutron generator was placed in the thermal neutron field at 50 cm and 150 cm from the reference position. The polyethylene neutron collimator was used to make moderated 14 MeV neutron field. These neutron spectra were measured by using a Bonner sphere system with an LiI scintillator, and dosimetric quantities delivered to neutron surveymeters were determined from these measurement results.

Practical Output Dosimetry with Undefined $N_{dw}{^{Co-60}}$ of Cylindrical Ionization Chamber for High Energy Photon Beams of Linear Accelerator ($N_{dw}{^{Co-60}}$이 정의되지 않은 원통형 이온전리함을 이용한 고에너지 광자선의 임상적 출력선량 결정)

  • Oh, Young-Kee;Choi, Tae-Jin;Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.114-122
    • /
    • 2012
  • For the determination of absorbed dose to water from a linear accelerator photon beams, it needs a exposure calibration factor $N_x$ or air kerma calibration factor $N_k$ of air ionization chamber. We used the exposure calibration factor $N_x$ to find the absorbed dose calibration factors of water in a reference source through the TG-21 and TRS-277 protocol. TG-21 used for determine the absorbed dose in accuracy, but it required complex calculations including the chamber dependent factors. The authors obtained the absorbed dose calibration factor $N_{dw}{^{Co-60}}$ for reduce the complex calculations with unknown $N_{dw}$ only with $N_x$ or $N_k$ calibration factor in a TM31010 (S/N 1055, 1057) ionization chambers. The results showed the uncertainty of calculated $N_{dw}$ of IC-15 which was known the $N_x$ and $N_{dw}$ is within -0.6% in TG-21, but 1.0% in TRS-277. and TM31010 was compared the $N_{dw}$ of SSDL to that of PSDL as shown the 0.4%, -2.8% uncertainty, respectively. The authors experimented with good agreement the calculated $N_{dw}$ is reliable for cross check the discrepancy of the calibration factor with unknown that of TM31010 and IC-15 chamber.