• Title/Summary/Keyword: 교실 연구

Search Result 2,426, Processing Time 0.031 seconds

Comparison of the Outcomes according to the Injury Type of the Short Radiolunate Ligament in Fracture-Dislocation of the Radiocarpal Joint (요수근 관절의 골절-탈구에서 단요월상인대의 손상 형태에 따른 치료 결과의 비교)

  • Heo, Youn Moo;Kim, Tae Gyun;Song, Jae Hwang;Jang, Min Gu;Lee, Seok Won
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.51-60
    • /
    • 2021
  • Purpose: Radiocarpal dislocation (RCD), which is caused by high-energy trauma, often involves radial styloid fractures and short radiolunate ligament (SRLL) injuries. Although SRLL injuries may occur as a simple rupture at the attachment site of radius, it may occur with a relatively large avulsed-fragment in the volar rim of the lunate facet of the radius. This study aimed to differentiate the injury type of SRLL and assess the differences in the treatment results depending on the treatment methods that have been applied in RCD with radial styloid fractures. Materials and Methods: Eighteen patients managed surgically with RCD were enrolled in this study. The patients were classified as Group 1 and Group 2 by using the Dumontier method. In this study, Group 2 was subdivided into 2A (purely ligamentous or small avulsion fracture of the volar rim of lunate facet) and 2B (large avulsed-fragment enough to internal fixation) according to the injury type of SRLL. Groups 2A and 2B were treated with direct repair and screw fixation, respectively. Pain, range of motion of the wrist joint, grip strength, and complications on final radiographs were examined. The outcomes were evaluated using patient-rated wrist evaluation (PRWE), and modified Mayo wrist score (MMWS). Results: All patients were Group 2 (six and twelve patients in 2A and 2B, respectively). The mean flexion to extension arch recovered 79%,and the mean grip strength was 72.9% of the uninjured side. Group 2A showed better recovery in extension, flexion and pronation than Group 2B, but there was no difference in radial deviation, ulnar deviation, supination, grip strength and pain. No differences in the PRWE and MMWS were observed between two groups. Complications included traumatic arthritis in seven patients and residual instability in five patients. Conclusion: When the SRLL was injured, the involvement of a large avulsion fracture on the anterior plane of the radiolunate did not affect the test results. On the other hand, it should be observed cautiously because avulsion fractures tend to disturb the joint's reduction through rotation or displacement. In addition, anatomical reduction and sturdy internal fixation are important for restoring the function of the SRLL.

Development of a prototype simulator for dental education (치의학 교육을 위한 프로토타입 시뮬레이터의 개발)

  • Mi-El Kim;Jaehoon Sim;Aein Mon;Myung-Joo Kim;Young-Seok Park;Ho-Beom Kwon;Jaeheung Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.257-267
    • /
    • 2023
  • Purpose. The purpose of the study was to fabricate a prototype robotic simulator for dental education, to test whether it could simulate mandibular movements, and to assess the possibility of the stimulator responding to stimuli during dental practice. Materials and methods. A virtual simulator model was developed based on segmentation of the hard tissues using cone-beam computed tomography (CBCT) data. The simulator frame was 3D printed using polylactic acid (PLA) material, and dentiforms and silicone face skin were also inserted. Servo actuators were used to control the movements of the simulator, and the simulator's response to dental stimuli was created by pressure and water level sensors. A water level test was performed to determine the specific threshold of the water level sensor. The mandibular movements and mandibular range of motion of the simulator were tested through computer simulation and the actual model. Results. The prototype robotic simulator consisted of an operational unit, an upper body with an electric device, a head with a temporomandibular joint (TMJ) and dentiforms. The TMJ of the simulator was capable of driving two degrees of freedom, implementing rotational and translational movements. In the water level test, the specific threshold of the water level sensor was 10.35 ml. The mandibular range of motion of the simulator was 50 mm in both computer simulation and the actual model. Conclusion. Although further advancements are still required to improve its efficiency and stability, the upper-body prototype simulator has the potential to be useful in dental practice education.

Predictors of a Favorable Outcome after Emergent Carotid Artery Stenting in Acute Anterior Circulation Stroke Patients (급성 전방순환 뇌경색 환자에서 응급 경동맥 스텐트 삽입술 후 양호한 임상 결과의 예측인자)

  • Gyeong Il Moon;Byung Hyun Baek;Seul Kee Kim;Yun Young Lee;Hyo-Jae Lee;Woong Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.3
    • /
    • pp.665-675
    • /
    • 2020
  • Purpose This study aimed to identify independent predictors of favorable outcomes associated with emergent carotid artery stenting (CAS) in patients with acute anterior circulation stroke. Materials and Methods This study included 93 patients with acute stroke who underwent emergent CAS to treat stenoocclusive lesions in the cervical internal carotid artery (ICA) within 6 hours of the onset of the associated symptoms. Data were compared between patients with and without favorable outcomes. The independent predictors of a favorable outcome were determined via logistic regression analysis (modified Rankin Scale 0-2 at 90 days). Results Intracranial tandem occlusion was noted in 81.7% of patients (76/93) among which (76/93), 55 of whom underwent intracranial recanalization therapy. Intracranial reperfusion was successful in 74.2% (69/93) and favorable outcomes were noted in 51.6% of patients (48/93). The mortality rate was 6.5% (6/93). In logistic regression analysis, diffusion-weighted imaging-Alberta Stroke Program Early CT Score [odds ratio (OR), 1.487; 95% confidence interval (CI), 1.018-2.173, p = 0.04], successful reperfusion (OR, 5.199; 95% CI, 1.566-17.265, p = 0.007), and parenchymal hemorrhage (OR, 0.042; 95% CI, 0.003-0.522, p = 0.014) were independently associated with a favorable outcome. Conclusion Baseline infarct size, reperfusion status, and parenchymal hemorrhage were independent predictors of favorable outcomes after emergent CAS to treat stenoocclusive lesions in the cervical ICA in patients with acute anterior circulation stroke.

Accuracy of bite registration according to the buccal bite scan range of intra-oral scanner (구강 스캐너의 협측 교합 스캔 부위에 따른 교합 인기의 정확도)

  • Tae-sung Kwon;Dae-hyun Kim;Min-su Kim;Dong-jun Song;Joo-Hun Song
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.3
    • /
    • pp.125-134
    • /
    • 2024
  • Purpose: The aim of this study was to determine which scan range would provide the most accurate bite registration when performing a bite scan after scanning an upper and lower arch using an intraoral scanner. Materials and Methods: The occlusal contact points were recorded using articulating paper for 30 adults, and the results of various ranges of buccal bite scan were compared based on this. Buccal bite scan of 5 ranges (1st premolar to 2nd premolar, 1st premolar to 1st molar, 1st premolar to 2nd molar, 2nd premolar to 1st molar, and canines to another side canine of the maxillary teeth) was performed, and then the buccal bite scan file was used in a CAD program to confirm the occlusal area in the scan file through data editing and alignment, leaving the buccal area of the teeth. Afterwards, the degree of agreement between the occlusal contact points obtained from the articulating paper and the occlusal area obtained from the scan file was compared, and statistical analysis was performed using the homoscedastic T-test (α = 0.05). Results: The alignment success and alignment failure rates among each group were 77.23% and 40.85% in canine to another side canine, 68.23% and 28.89% in bilateral first premolar to second premolar, 63.76% and 29.97% in bilateral first premolar to first molar, 61.31% and 32.04% in bilateral first premolar to second molar, 67.55% and 27.46% in second premolar to first molar. The results of the anterior scan of both canines showed higher alignment success and failure rates compared to the scan results of all maxillary posterior teeth. In the alignment success rate, statistical significance was not found depending on the scan range of the posterior teeth, but in comparing the results of the posterior teeth and both canines, statistical significance was observed except for the scan results of the second premolar to the first molar. There was no statistical significance in the alignment failure rate depending on the scan range of the posterior teeth, and statistical significance was observed in the results of the posterior teeth and both canines. Conclusion: When taking a buccal bite scan, in the case of scanning the anterior teeth, more occlusal area appear than when scanning the posterior teeth, and in the case of scanning the posterior teeth, there is no significant difference in the bite registration depending on the scan range.

Association of Cognitive Dysfunction with Thyroid Autoantibody (갑상선 자가항체와 인지기능 저하의 연관성)

  • Han, Dong Kyun;Cheon, Jin Sook;Choi, Young Sik;Kim, Ho Chan;Oh, Byoung Hoon
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.24 no.2
    • /
    • pp.227-235
    • /
    • 2016
  • Objectives : The aims of this study were to know the frequency of cognitive dysfunction among patients with autoimmune thyroid disorders, and to reveal influencing factors on it, especially to clarify association with autoimmune thyroid antibodies. Methods : From sixty-five female patients with autoimmune thyroid disorders, demographic data were obtained by structured interview. Their cognitive funtions were measured using the MMSE-K and the MoCA-K tests. Depression was evaluated by the K-HDRS. Results : 1) Among patients with autoimmune thyroid disorders, 7.69% of them were below 24 on the MMSE-K, while 10.77% were below 22 on the MoCA-K. The frequency of cognitive deficit was not significantly different according to having positivity to antimicrosomal antibodies or not. 2) The antimicrosomal antibody-positive patients had significantly higher antithyroglobulin antibody titers, antimicrosomal antibody titers, and TSH concentration, while had significantly lower free T4 levels(p<0.05, respectively). 3) The total scores of the MMSE-K and the MoCA-K had significant correlation with age, marital status, antithyroglobulin antibody titers and K-HDRS(p<0.05, respectively). 4) The regression analysis revealed that variables such as age, education, autoimmune thyroid antibodies, thyroid function and depression did not influence on cognitive function of patients with autoimmune thyroid disorders. Conclusions : Our results could not support that cognitive function of patients with autoimmune thyroid disorders had correlation with autoimmune thyroid antibodies.

Questionnaire survey for the clinical trial participants who experienced both digital and conventional impression (디지털 인상법과 종래인상법을 동시에 경험한 임상시험자를 대상으로 한 설문지분석)

  • Yang, Eunbee;Kim, Bongju;Lee, Jun Jae;Lee, Seung-Pyo;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.270-279
    • /
    • 2018
  • Purpose: The aim of this study was to assess the patients' perception, acceptance, and preference of the difference between a conventional impression and digital impression through questionnaire survey. Materials and Methods: Thirteen (6 male, 7 female) subjects who experienced both digital and conventional impression at the same day were enrolled in this study. Conventional impression were taken with polyvinylsiloxane and digital impression were performed using a newly developed intra-oral scanner. Immediately after the two impressions were made, a survey was conducted with the standardized questionnaires consisting of the following three categories; 1) general dental treatment 2) satisfaction of conventional impression 3) satisfaction of digital impression. The perceived source of satisfaction was evaluated using Likert scale. The distribution of the answers was assessed by percentages and statistical analyses were performed with the paired t-test, and P < 0.05 was considered significant. Results: There were significant differences of the overall satisfaction between two impression methods (P < 0.05). Digital impression showed high satisfaction in less shortness of breath and odor to participants compared to conventional impression. The use of an oral scanner resulted in a discomfort of TMJ due to prolonged mouth opening and in lower score of the scanner tip size. Conclusion: It was confirmed that the preference for the digital impression using intraoral scanner is higher than the conventional impression. Most survey participants said they would recommend the digital impression to others and said they preferred it for future prosthetic treatment.

Influence of crown-to-implant ratio of short vs long implants on implant stability and marginal bone loss in the mandibular single molar implant (하악 구치 단일임플란트 수복에서 임플란트 길이에 따른 치관-임플란트 비율이 임플란트안정성 및 변연골소실에 주는 영향)

  • Baek, Yeon-Wha;Kim, Bongju;Kim, Myung-Joo;Kwon, Ho-Beom;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.280-289
    • /
    • 2018
  • Purpose: The purpose of this randomized clinical trial is to determine whether implant length and the crown-to-implant (C/I) ratio influence implant stability and peri-implant marginal bone loss (MBL). Materials and Methods: 46 patients with single tooth missing in the posterior molar region of the mandible were included in this study. 19 implants (CMI IS-III $active^{(R)}$ long implant) of 5.0 mm diameter and 10 mm length were installed for the control group, while 27 implants (CMI IS-III $active^{(R)}$ short implant) of 5.5 mm diameter and 6.6, 7.3 or 8.5 mm length were placed for the experimental group. Each implant was inserted and immediately loaded using the digitally pre-fabricated surgical template and provisional restoration. The CAD-CAM monolithic zirconia crown was fabricated at 3 months after the surgery as a definitive restoration. The ISQ value and the MBL was measured at 48 weeks after the surgery. The correlation between the C/I ratio, MBL, and secondary implant stability was analyzed. Results: Successful results in terms of ISQ and MBL were achieved with both groups. There was no significant difference between the groups in terms of ISQ values and MBL at 48 weeks after the surgery (P > 0.05). No significant correlation was found between the C/I ratio and secondary stability as well as the C/I ratio and the MBL (P > 0.05). Conclusion: The influence of C/I ratio in both groups was not shown on the stability nor the marginal bone loss in implants supporting single crown of the mandible. Short implant could be a preferable alternative option in the reduced bone height mandible under the limited condition despite its higher C/I ratio.

Comparative Analysis of Detection Methods for Food-borne Pathogens in Fresh-cut Agricultural Materials (신선 농산물내 식중독균 검출 방법의 비교 분석)

  • Jang, Hye-Jeong;Kim, Hye-Jeong;Park, Ji-in;Yu, Sun-Nyoung;Park, Bo-Bae;Ha, Gang-Ja;Ahn, Soon-Cheol;Kim, Dong-Seob
    • Journal of Life Science
    • /
    • v.31 no.1
    • /
    • pp.10-16
    • /
    • 2021
  • The consumption of fresh-cut agricultural materials is increasing due to increased public interest in health and the increase of single-person households. Most fresh-cut agricultural materials can be eaten without heating, thus easily exposing the consumer to food-borne pathogens. As a result, food-borne diseases are increasing worldwide. In the analysis of food-borne pathogens, it is important to detect the strains, but this is time consuming and laborious. Alternative detection methods that have been introduced, include polymerase chain reaction-denaturing gradient gel electrophoresis (PCR-DGGE), which is performed without prior culturing. Samples of fresh-cut agricultural materials, such as vegetables, were analyzed by the culture-based method. In 129 samples, non-pathogenic Escherichia coli (3.9%), Bacillus cereus (31.8%), Clostridium perfringens (5.4%), Yersinia enterocolitica (0.8%), and enterohemorrhagic E. coli (0.8%) were detected. Eight samples contaminated with bacteria were randomly selected, further analyzed by PCR-DGGE, and compared with the culture-based method. Two cases detected non-pathogenic E. coli by PCR-DGGE only, despite a lack of detection by the culture method. It was supposed there was possibility of sample loss during its 10-fold dilution for appropriate cultivation. In the detection of high-risk food-borne pathogens, it was found that the detection limit was lower in PCR-DGGE than in the culture-based method (10 CFU/g). This suggests that PCR-DGGE can be alternatively used to detect strains. On the other hand, low-risk food-borne pathogens seem to have higher detection limits in PCR-DGGE. Consequentially, this study contributes to the improvement of food-borne pathogen detection and the prevention of its related-diseases in fresh-cut agricultural materials.

Evaluation of the Color Adjustment Potential of Single-Shade Composite Resin in Primary Teeth (유치에서의 단일 색조 복합레진의 색조 적응력 평가)

  • Yongsoon Kim;Howon Park;Juhyun Lee;Haeni Kim
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.1
    • /
    • pp.113-120
    • /
    • 2023
  • Restoring composite resins with the optimal shades for all primary teeth is a great challenge for pediatric dentists. A newly developed single-shade composite resin can exhibit a color similar to that of the surrounding tooth structure based on the structural color phenomenon. This study aims to evaluate the color adjustment potential (CAP) of a single-shade composite resin compared to conventional multi-shade composite resins in primary teeth. A single-shade composite resin and two conventional multi-shade composite resins were included in this study. Two types of specimens, a single specimen and a dual specimen, were evaluated. For single specimens, duplications of the primary second molar denture teeth were made using experimental composite resins. For dual specimens, cavities were prepared on the buccal surfaces of extracted primary second molars and restored with experimental composite resins. The L*, a*, and b* values were measured using a colorimeter for the extracted teeth and specimens. The mean ΔEab* values for single and dual specimens and CAP were calculated. Bonferroni post-hoc analysis was performed to confirm the statistical significance between the ΔEab* and CAP values of the experimental resins. Among the single specimens, the single-shade composite resin showed significantly higher ΔESingle compared to other composite resins (p < 0.0167). There was no significant difference between ΔEDual for all experimental resins. The single-shade composite resin showed highest CAP compared to other multi-shade composite resins. A single-shade composite resin exhibited the most prominent color adaptability compared to other conventional multi-shade composite resins for primary second molars. A single-shade composite resin can simplify shade matching and provide esthetic outcomes for the restoration of primary second molars.

Prevalence and Patterns of Congenitally Missing Teeth among Pediatric Patients Aged 8 - 16 in Pusan National University Dental Hospital (부산대학교 치과병원에 내원한 8 - 16세 환자의 선천성 치아 결손 유병률 및 유형 평가)

  • Eunjin Kim;Soyoung Park;Eungyung Lee;Taesung Jeong;Jonghyun Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.2
    • /
    • pp.179-191
    • /
    • 2023
  • The purpose of this study was to investigate the prevalence and patterns of congenitally missing teeth in permanent teeth excluding third molars, in patients aged 8 to 16 years who visited Pusan National University Dental Hospital from January 2010 to February 2021. This retrospective study evaluated tooth agenesis and the pattern of missing teeth represented by the tooth agenesis code by reviewing panoramic radiographs and electronic medical records of 11,759 patients, including 5,548 females and 6,211 males. The prevalence of congenitally missing teeth was 10.74% (females 11.95%, males 9.66%, p < 0.0001). Patients with tooth agenesis had an average of 2.22 missing teeth, and congenitally missing teeth occurred more frequently in the mandible (8.39%) than in the maxilla (4.52%, p < 0.0001). The mandibular second premolar (58.19%) was the most frequently missing tooth. The second premolar was the most frequently missing tooth in all quadrants (30.10%, 31.67%, 43.14%, and 35.59%) when a single tooth was absent, while the first and second premolars were the most commonly absent teeth (11.69%, 11.47%, 5.94%, and 5.24%) when two or more teeth were missing. In the relationship between maxillary-mandibular antagonistic quadrants and full mouth, the 1st to 4th place of the missing patterns were all involved with the 1st and 2nd premolars. This study can be clinically helpful in establishing a treatment plan for patients with missing teeth. In addition, it can be used as basic data for molecular biological research to find out the relationship between tooth agenesis and specific genes.