• Title/Summary/Keyword: 교류 전류

Search Result 465, Processing Time 0.03 seconds

Decoupling of Thrust Force and Levitation Force of Transverse Flux Linear Induction Motor by the Active Compensation of Magnetic force across the Air-Gap (공극력의 능동적 보상을 통한 횡자속 선형 유도 구동기의 추력과 부상력의 비연성화)

  • 정광석;백윤수
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.11
    • /
    • pp.91-98
    • /
    • 2004
  • TFLIM(Transverse Flux Linear Induction Motor), making its closed magnetic path with the direction of the traveling field orthogonal, had been developed to decrease an edge effect of the general induction motor. To control the levitation force and the thrust force on the secondary part of TFLIM independently, the various methodologies have been presented. When we try to achieve the independent control using only the multi-phase inputs assigned in the stator coils as an approach, in which condition we can minimize the coupling effect between two forces\ulcorner In this paper, we show the qualitative influence of a slip frequency, an ac magnitude, a dc offset superposed in the ac power, and a major parameter of TFLIM on the couple through the computer simulation. And to realize the independent motions between levitation and thrust motion without any auxiliary means fur isolation of the secondary part of TFLIM, the decouple compensator is suggested, including the experimental results.

An Implementation of a Hall Sensor position compensation algorithm for the Muli-pole Type BLDC motor driving with the DSP(TMS320F28335). (DSP(TMS320F28335)를 이용하는 다극 BLDC 전동기 구동을 위한 홀센서 절대위치 보정 알고리즘 구현법)

  • Park, Jun-ho;Lim, Dong-gyun;Choi, Jung-keyng
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.391-394
    • /
    • 2014
  • In this paper, we introduce a method of determining the absolute position of the rotor for the vector control of Hall sensor type multi-pole BLDC motor using the DSP(TMS320F28335), and implement an algorithm to complement the problems of the conventional method. The switching method of the inverter for providing desired sinusoidal current to each phase of a motor, we adopt Space-Vector pulse width modulation method. In order to increase the speed range, Field-Weakness control method are used. In order to verify the proposed algorithm, we compare the value of Iqe, Ide and phase currents with the values before compensated.

  • PDF

Critical current and AC loss characteristic of Coated Conductor under bending (Coated Conductor의 굽힘변형에 따른 임계전류 및 교류손실 특성)

  • Kim, Hae-Joon;Sim, Ki-Deok;Kim, Seok-Ho;Cho, Jeon-Wook;Jang, H.M.;Lee, S.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.10 no.3
    • /
    • pp.23-26
    • /
    • 2008
  • Constructions of coated conductor which is differently from Bi-2223 is comprised multiple coatings on a base material or substrate and designed to achieve the highest degree of alignment possibility of the atoms in the superconductor material. In this study, we are measured and analyzed degradations of critical current according to diameter. In addition to study the effects of bending strain, we observed the AC loss of coated conductor and carried out analytical study for relation between Ic degradation and AC loss as well. The measurement of AC loss and numerical calculation was carried out based on Norris theory to compare with experimental results. The relationship between critical current and AC loss of HTS tapes with partial deformation by mechanical stress was studied. These results will amount the most important basis data in the of HTS cable, magnet, etc that winding work is required.

The Study of the Optical Current Sensor Using Magneto-Optic Effects (자기광학효과를 이용한 광전류센서에 관한 연구)

  • 전재일;이정수;송시준;정철우;박원주;이광식;김정배;김민수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.47-53
    • /
    • 2003
  • In this paper, we described the laboratory layout of the optical CT in connection with the measurement of large current based on Magneto-Optic Effects. It was used He-Ne laser for light source and was used PIN-Photodiode for light receiver. The sensing section was organized by winding optical fiber around conductor on the concept that the rotation angle of polarizing axis by Faraday Effect is proportional to the applied current in to conduction. The optical signal passed through optical fiber sensor was induced to analyzer arranged in the direction of $\theta$ for input polarization, and then analyzed its rotation angle and researched on operating characteristics of optical CT for 60[Hz] AC current measurement from l00[A] to 1000[A] was carried out. In this results, the output signals induced linearly with the current and proved that the intensity is increased with increasing turns of fiber through output differences which in accordance with turns of fiber and we verified that there is not only difference of the output with the medium between electric field and optical fiber, but also the lineality. Measuring the references and output intensities of the optical CT, ratio errors were within $\pm$7%. This confirmed that error rate will be improved by each medium and turns.

A Study for Predicting Rotational Cutting Torque from Electrical Energy Required for Ground Drilling (지반절삭 전기에너지를 활용한 회전굴착토크 예측에 관한 연구)

  • Choi, Chang-Ho;Cho, Jin-Woo;Lee, Yong-Soo;Chung, Ha-Ik;Park, Yong-Boo
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.7
    • /
    • pp.57-64
    • /
    • 2007
  • This study proposes a method to estimate drilling torque during ground boring with an aid of electrical energy required for rotating a boring-auger. Ground boring is commonly used in geotechnical engineering such as preboring precast pile installation, soil-cement grouting, ground exploration and so forth. In order to understand the correlation between required electrical energy to rotate the boring auger and the drilling torque, a small laboratory apparatus was designed and a pilot study was performed. The apparatus rotates common drill bits of $D=5{\sim}25mm$ in CBR specimens. The velocity of a bit is 19 RPM and predefined using a reduction gear which connects a main rotation axis to a 25 Watts AC electrical motor shaft. In the middle of drilling the motor current increments and the drilling torque were measured and the correlation between the current and the torque was obtained through linear square fits. Based on the correlation the acquired motor current during drilling was applied to predict the drilling torque in consequent testing and the prediction results were compared to the measured torque. The comparison leads a conclusion that the motor current during drilling using electrical power may be a good indicator to estimate/determine strength characteristics of the ground.

EIS monitoring on corroded reinforcing steel in cement mortar after calcium electro-deposition treatment (칼슘 전착처리 후, 시멘트 모르타르 속 철근의 부식속도에 대한 EIS 모니터링)

  • Kim, Je-Kyoung;Kee, Seong-Hoon;Yee, Jurng-Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.1-8
    • /
    • 2019
  • The primary purposes of this study are to understand a fundamental effects of electro-deposition on reinforcing steel in saturated Ca(OH)2 electrolyte, and evaluate the corrosion rates of rebars under cyclic 3wt.%NaCl immersion and dry corrosion environment. The three cement mortar specimens with cover thickness 5, 10 and 30mm, were prepared in the experiment. To monitor the corrosion rates of rebars in mortar, the three cement mortar specimens were exposed to 110 wet-drying cycles(8-hour-immersion in 3wt.%NaCl and 16-hour-drying in a room temperature) in the laboratory. During the wet-dry cycles, the polarization resistance, Rp, and solution resistance, Rs, were continuously measured. The instantaneous corrosion rates of rebars on the effect of electro-depositing with sat. Ca(OH)2 electrolyte were estimated from obtained R-1p and degrees of wetness were estimated from Rs values. From the experimental results, the corrosion rates of rebars were greatly accelerated by wet/dry cycles. During the mortars exposed to drying condition, the large increases in the corrosion rates were showed at all rebar surfaces in three mortar specimen, attributed from the accelerated reduction rates of dissolved oxygen in drying process. However, the corrosion rates on rebar surface electrochemically deposited with sat. Ca(OH)2 electrolyte showed the clear decreases, caused by calcium deposits in the porous rust layer.

Thin Film Chromel-Alumel Multjunction Thermal Converter (박막형 크로멜-알루멜 다중접합 열전변환기)

  • Jung, In-Sik;Kim, Jin-Sup;Lee, Jung-Hee;Lee, Jong-Hyun;Shin, Jang-Kyoo;Park, Se-Il;Kwon, Sung-Won
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.9
    • /
    • pp.37-45
    • /
    • 1999
  • For the purpose of reducing the output voltage fluctuation of thin film multijunction thermal converter, EVANOHM alloy-S and chromel-alumel thermocouple were used as a thin film heater material and as a thermoelement of thrmopile, respectively. The temperature coefficient of the resistance of thin film EVANOHM alloy-S heater was about $1.4 {\times} 10^4/^{\circ}C$, which is very small compared to other materials, and thin film chromel-alumel thermocouple showed relatively small difference of the Seebeck coefficients about $38 {\mu}V/K$. The output voltage fluctuation of the thermal converter was about 0.06% for the initial 120 seconds in air and decreased considerably after preheating for 5 minutes or more. The respective AC-DC voltage and current transfer error ranges of the thermal converter were about ${\pm}$1.6 ppm and ${\pm}$0.7 ppm in the frequency range from 10Hz to 10 kHz and increased remarkably below 10 Hz or above 10 kHz.

  • PDF

Comparison of PI and PR Controller Based Current Control Schemes for Single-Phase Grid-Connected PV Inverter (단상 계통 연계형 태양광 인버터에 사용되는 PI 와 PR 전류제어기의 비교 분석)

  • Vu, Trung-Kien;Seong, Se-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.8
    • /
    • pp.2968-2974
    • /
    • 2010
  • Nowadays, the PV systems have been focused on the grid connection between the power source and the grid. The PV inverter can be considered as the core of the whole system because of an important role in the grid-interfacing operation. An important issue in the inverter control is the load current regulation. In the literature, Proportional Integral (PI) controller, which is normally used in the current-controlled Voltage Source Inverter (VSI), cannot be a satisfactory controller for an AC system because of the steady-sate error and the poor disturbance rejection, especially in high-frequency range. Compared with conventional PI controller, Proportional Resonant (PR) controller can introduce an infinite gain at the fundamental frequency of the AC source; hence it can achieve the zero steady-state error without requiring the complex transformation and the de-coupling technique. Theoretical analyses of both PI and PR controller are presented and verified by simulation and experiment. Both controller are implemented in a 32-bit fixed-point TMS320F2812 DSP processor and evaluated on a 3kW experimental prototype PV Power Conditioning System (PCS). Simulation and experimental results are shown to verify the controller performances.

Generation of Free Chlorine Using $RuO_2$/ Ti Electrode with Various Amount of Ru (Ru 코팅량에 따른 $RuO_2$/Ti 전극의 염소 발생)

  • Lee, JunCheol;Pak, DaeWon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.11
    • /
    • pp.715-719
    • /
    • 2012
  • We investigated the effects of electrochemical characteristics and generation of chlorine by the different amount of Ru coating which was prepared for $RuO_2$/Ti electrode coated with 1.5 mg, 2.5 mg, 5.5 mg, 8.5 mg Ru per unit area ($cm^2$). As a Result of the cycle voltammetry experiments, chlorine overvoltage of Ru-coated electrodes showed to be the nearly sustained value of approximately 1.15V (vs. Ag/AgCl). By contrary, According to the results of the AC impedance spectroscopy and potentiodynamic polarization tests, the amount of Ru per unit area ($cm^2$) included 2.5 mg, 3.5 mg as $RuO_2$/Ti offered the highest levels of durability which was electrode resistance and corrosion rate appeared to be $0.4582{\Omega}$, $0.5267{\Omega}$ and 0.082 mm/yr, 0.058 mm/yr, respectively. It was also observed that generation of chlorine coated with 3.5 mg per unit area ($cm^2$) was the highest value of 15.2 mg/L.

Synthesis of Lithium Manganese Oxide by a Sol-Gel Method and Its Electrochemical Behaviors (졸-겔 방법에 의한 LiMn2O4의 합성 및 전기화학적 거동)

  • Jeong, Euh-Duck;Moon, Sung-Wook;Lee, Hak-Myoung;Won, Mi-Sook;Yoon, Jang-Hee;Park, Deog-Su;Shim, Yoon-Bo
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.4
    • /
    • pp.229-235
    • /
    • 2003
  • A precursor of lithium manganese oxide was synthesized by mixing $(CH_3)_2CHOLi\;with\;Mn(CH_3COO)_2{\cdot}4H_2O$ in ethanol using a sol-gel method, then heat-treated at $400^{\circ}C\;and\;800^{\circ}C$ in air atmosphere. The condition of heat treatment was determined by thermogravimetric analysis/differential thermogravimetric analysis (TGA/DTA). The characterization of the lithium manganese oxide was done by X-ray diffraction (XRD) spectra and scanning electron microscopy (SEM). The electrochemical characteristics of lithium manganese oxide electrode for lithium ion battery were measured by cyclic voltammetry (CV), chronoamperometry and AC impedance method using constant charge/discharge process. The electrochemical behaviors of the electrode have been investigated in a 1.0M $LiClO_4/propylene$ carbonate electrolyte solution. The diffusivity of lithium ions, $D^+\;_{Li}\;^+$, as determined by AC impedance technique was $6.2\times10^{-10}cm^2s^{-1}$.