• Title/Summary/Keyword: 교류손실

Search Result 221, Processing Time 0.024 seconds

AC Loss Characteristics of Stacked BSCCO-2223 Tapes by Using Magnetization Method (자화법을 이용한 적층된 BSCCO-2223 교류손실 특성의 해석)

  • Kang, Hyoung-Ku;Nah, Wan-Soo;Joo, Jin-Ho;Yoo, Jai-Moo;Kim, Kye-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.262-264
    • /
    • 1999
  • The AC losses of BSCCO-2223 multifilamentary superconducting tapes were measured using magnetization method and compared with the results of theoretically calculated values. In general, AC losses in multifilamentary superconducting tapes could be quantitatively explained by the simple sum of the Hysteresis and Coupling Loss. As a result of experiment, We found that AC losses of multifilamentary superconducting tape increase rapidly in large magnetic field region.

  • PDF

Influence of tape′s arrangements on AC Loss Characteristics in a 3-conductor (테이프 배열이 3본-도체의 교류손실 특성에 미치는 영향)

  • 조영호;허대행;류경우;최병주;황시돌
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.260-262
    • /
    • 2003
  • AC loss is an important issue in the design of high-T$_{c}$, superconducting power cables which consist of a number of Bi-2223 tapes wound on a cylindrical former. In this paper, the ac loss characteristics in the 3-conductor have investigated experimentally. The loss test results indicate that the ac loss is not related to the arrangement of Bi-2223 tapes, contact position and applied frequency. The measured losses in face-to-face arrangement are larger than those in edge-to-edge arrangement. The measured losses in the 3-conductor also agree well with the sum of the transport losses measured in each Bi-2223 tape.e.

  • PDF

Effect of Conductor's Arrangement and Current Direction on AC Loss Characteristics of a Fault Current Limiting Coil (도체의 배열 및 전류방향이 코일형 한류소자의 교류손실 특성에 미치는 영향)

  • Ma Y. H.;Ryu Kyung-Woo;Park K. B.;Oh Il-Sung
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.3
    • /
    • pp.17-20
    • /
    • 2005
  • AC loss of a high $T_c$ superconducting conductor has a strong influence on the economic viability of a superconducting fault current limiter, which offers an attractive means to limit short circuit current in the power systems. Therefore, several samples of the fault current limiting coils have been fabricated and the effect of conductor's arrangement and current direction on AC loss characteristics investigated experimentally The test result shows that the AC losses measured in the fault current limiting coils depend significantly on the conductor's arrangement. Futhermore, they are also considerably influenced by the conductor's current direction. The AC loss measured in the face-to-face arrangement is smallest among the fault current limiting coil samples.

Current Distribution and Numerical Analysis of AC Losses on Multi-Layer HTS Cable (다층 고온 초전도 케이블의 전류 분포 및 교류손실 해석)

  • 김영석;이병성;장현만;곽민환;김상현
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.452-455
    • /
    • 2000
  • Superconducting power cable is one of the most promising energy application of high-T$_{c}$ superconductors (HTS). A prototype HTS cable have been constructed multi-layer cable using Bi-2223 tape and tested. The AC transport losses under self field were investigated at 77K on the 19 filamentary tape and multi-layer HTS cables. And we carried out numerical analysis using bean model. The result shows that the total transport current of HTS cable in L$N_2$ was 475[A], and transport current passed through almost the outer layer (2-layer). Also, AC transport losses in outer layer of HTS cable was proportion to I$^2$ and higher than losses of inner layer. In case of Ip=Ic, calculated numerical loss density was concentrated on the edge of tape and most of loss density in cable was distributed outer layer more than inner layer. As magnetic distribution was concentrated on outer layer.r.

  • PDF

A Method of Rack Level Power Supply to Save Data Center Energy (데이터센터 에너지 절감을 위한 랙 수준 전력 공급 방법)

  • Cho, Soohyung;Kim, Daehwan
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2018.10a
    • /
    • pp.11-12
    • /
    • 2018
  • 대부분의 컴퓨팅 장비들은 교류 전력을 공급받지만 실제 직류로 동작하기 때문에 교류를 직류로 변환하는 전원 공급장치가 필수적이다. 문제는 이과정에서 손실 발생하기 때문에 이를 최소한으로 줄이는 방법이 필요한데 이를 위해 본 논문은 OCP에서 제안한 방법대로 랙 수준의 전원 공급 장치와 DC 서버의 전력 공급 연력 방법에 대해 설계하였으며 이렇게 구성하였을 경우 어떻게 에너지 절감량을 측정할 수 있는가에 대해 설명하였다. 이 방법대로 상용 데이터 센터에 실제 도입이 이루어진다면 데이터 센터 산업이 소모하는 에너지 사용량을 줄이는데 기여할 수 있을 것이다.

Critical Current and AC loss Characteristics with Pitch of HTS tape (HTS tape의 Pitch에 따른 임계전류 및 교류손실 특성)

  • Kim, Hae-Joon;Sim, Ki-Deok;Kim, Jae-Ho;Kim, Seok-Ho;Cho, Jeon-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.265-266
    • /
    • 2006
  • Superconductor is developed for applications in high-power devices such as power-transmission cables, transformers, motor and generators. In such applications, HTS tapes are subjected to various kinds of stress or strain. In the fabrication of the devices, the critical current (Ic) of the high temperature superconductor degrades due to many reasons including the tension applied by bending, twist and thermal contraction. In particular manufactured HTS cable, we need pitch angle controls. This paper is analyzed that Ic characteristics is changed pitch angle of HTS tape. These results will amount the most important basis data in HTS cable.

  • PDF

Design of 22.9kV High Temperature Superconducting Cable Considering AC losses and Stability (교류손실 및 안정성을 고려한 22.9kV 초전도 케이블 설계)

  • Jang, H.M.;Lee, C.Y.;Kim, C.D.;Sim, K.D.;Cho, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1210-1212
    • /
    • 2005
  • High temperature superconducting(HTS) power cable system consists of HTS cable, termination and cryogenic system. And the HTS cable consists of the former, HTS phase conductor, electric insulation, HTS shield and cryostat. Taking the advantage of HTS shield, the cold dielectric has been adopted. The phase conductor and the shield have been designed to minimize the AC loss below 1W/m/phase. The former has been designed to transport the fault current of 25kA, at fault condition. This paper describes the design process of 22.9kV HTS cable considering AC losses at normal state and the stability at fault condition.

  • PDF

A study on the reduction of ac loss of YBCO coated conductor by a mechanical striation method (기계적으로 분할된 YBCO 선재의 교류손실 감소에 대한 연구)

  • Yoo, Yong-Su;Hong, Gye-Won;Lee, Hee-Gyoun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • High temperature superconductor (HTS) coated conductors has high hysteretic magnetization loss which is an obstacle for the AC applications of coated conductors. We propose a method to reduce the magnetization loss of the coated conductor. It is the mechanical striation method by load variety using office knife. The magnetization loss measured in the mechanical striated YBCO coated conductor without copper layer was compared with the loss generated by perpendicularly exposed external magnetic filed. The reduction in magnetization loss due to the mechanical striation is clearly shown at higher field and was dependent on the striation number. The mechanical striation method was proven to have additional advantages of a low cost and high fabrication process.

Electrical Properties of 18[kV] ZnO Surge Arrester Stressed by the Mixed DC and 60[Hz] AC Voltages (직류+60[Hz]교류 중첩전압에 대한 18[kV] ZnO 피뢰기의 전기적 특성)

  • Lee, Su-Bong;Lee, Seung-Ju;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.66-72
    • /
    • 2007
  • This paper describes the characteristics of power loss and leakage currents flowing through new and used 18[kV] zinc oxide(ZnO) surge arrester under the mixed DC and AC voltages. The mixed DC and AC voltage generator of 50[kV] peak was designed and fabricated. The I-V curves of ZnO surge arrester were measured as a function of the voltage ratio K. The I-V curves under the mixed DC and AC voltages lay between the pure DC and AC characteristics, and the cross-over phenomenon in both I-V curves and R-V curves was observed at the low current region. As a result, the increase of DC component in the mixed voltages causes the increase of resistive component of total leakage current of ZnO surge arrester. Also, in the case of same applied voltage, the leakage current flowing through the used ZnO surge arrester was higher than that of the new ZnO surge arrester.

A single-stage ac/dc converter with high power factor and low power loss (고역율, 저손실 1단 교류/직류 변환기)

  • 차영길;박성우;백주원;김흥근
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.413-416
    • /
    • 1997
  • In this paper, we propose a new single-stage isolated switching power supply. The proposed converter reduces the diode conduction loss and offer both the high input Power factor and the direction conversion from the ac line to a dc output voltage. This paper present the Operational principle, analysis and control and experimental results of a 100W prototype.

  • PDF