• Title/Summary/Keyword: 광전자증배관

Search Result 24, Processing Time 0.031 seconds

Investigation of the Signal Characteristics of a Small Gamma Camera System Using NaI(Tl)-Position Sensitive Photomultiplier Tube (NaI(Tl) 섬광결정과 위치민감형 광전자증배관을 이용한 소형 감마카메라의 신호 특성 고찰)

  • Choi, Yong;Kim, Jong-Ho;Kim, Joon-Young;Im, Ki-Chun;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Joo, Koan-Sik;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.1
    • /
    • pp.82-93
    • /
    • 2000
  • Purpose: We characterized the signals obtained from the components of a small gamma camera using Nal(Tl)-position sensitive photomultiplier tube (PSPMT) and optimized the parameters employed in the modules of the system. Materials and Methods: The small gamma camera system consists of a Nal(Tl) crystal ($60{\times}60{\times}6mm^3$) coupled with a Hamamatsu R3941 PSPMT, a resister chain circuit, preamplifiers, nuclear instrument modules (NIMs), an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a resistive charge division circuit which multiplexes the 34 cross wire anode channels into 4 signals (X+, X-, Y+, Y -). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated and digitized via triggering signal and used to localize the position of an event by applying the Anger logic. The gamma camera control and image display was performed by a program implemented using a graphic software. Results: The characteristics of signal and the parameters employed in each module of the system were presented. The intrinsic sensitivity of the system was approximately $8{\times}10^3$ counts/sec/${\mu}Ci$. The intrinsic energy resolution of the system was 18% FWHM at 140 keV. The spatial resolution obtained using a line-slit mask and $^{99m}Tc$ point source were, respectively, 2.2 and 2.3 mm FWHM in X and Y directions. Breast phantom containing $2{\sim}7mm$ diameter spheres was successfully imaged with a parallel hole collimator. The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We proposed a simple method for development of a small gamma camera and presented the characteristics of the signals from the system and the optimized parameters used in the modules of the small gamma camera.

  • PDF

Development of Position Encoding Circuit for a Multi-Anode Position Sensitive Photomultiplier Tube (다중양극 위치민감형 광전자증배관을 위한 위치검출회로 개발)

  • Kwon, Sun-Il;Hong, Seong-Jong;Ito, Mikiko;Yoon, Hyun-Suk;Lee, Geon-Song;Sim, Kwang-Souk;Rhee, June-Tak;Lee, Dong-Soo;Lee, Jae-Sung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.469-477
    • /
    • 2008
  • Purpose: The goal of this paper is to present the design and performance of a position encoding circuit for $16{\times}16$ array of position sensitive multi-anode photomultiplier tube for small animal PET scanners. This circuit which reduces the number of readout channels from 256 to 4 channels is based on a charge division method utilizing a resistor array. Materials and Methods: The position encoding circuit was simulated with PSpice before fabrication. The position encoding circuit reads out the signals from H9500 flat panel PMTs (Hamamatsu Photonics K.K., Japan) on which $1.5{\times}1.5{\times}7.0\;mm^3$ $L_{0.9}GSO$ ($Lu_{1.8}Gd_{0.2}SiO_{5}:Ce$) crystals were mounted. For coincidence detection, two different PET modules were used. One PET module consisted of a $29{\times}29\;L_{0.9}GSO$ crystal layer, and the other PET module two $28{\times}28$ and $29{\times}29\;L_{0.9}GSO$ crystal layers which have relative offsets by half a crystal pitch in x- and y-directions. The crystal mapping algorithm was also developed to identify crystals. Results: Each crystal was clearly visible in flood images. The crystal identification capability was enhanced further by changing the values of resistors near the edge of the resistor array. Energy resolutions of individual crystal were about 11.6%(SD 1.6). The flood images were segmented well with the proposed crystal mapping algorithm. Conclusion: The position encoding circuit resulted in a clear separation of crystals and sufficient energy resolutions with H9500 flat-panel PMT and $L_{0.9}GSO$ crystals. This circuit is good enough for use in small animal PET scanners.

Monte Carlo Simulations of Detection Efficiency and Position Resolution of NaI(TI)-PMT Detector used in Small Gamma Camera (소형 감마카메라 제작에 사용되는 NaI(TI)- 광전자증배관 검출기의 민감도와 위치 분해능 특성 연구를 위한 몬테카를로 시뮬레이션)

  • Kim, Jong-Ho;Choi, Yong;Kim, Jun-Young;Im, Ki-Chun;Kim, Sang-Eun;Choi, Yeon-Sung;Joo, Kwan-Sik;Kim, Young-Jin;Kim, Byung-Tae
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.67-76
    • /
    • 1997
  • We studied optical behavior of scintillation light generated in NaI(TI) crystal using Monte Carlo simulation method. The simulation was performed for the model of NaI(TI) scintillator (size: 60 mm ${\times}$ 60 mm ${\times}$ 6 mm) using an optical tracking code. The sensitivity as a function of surface treatment (Ground, Polished, Metal-0.95RC, Polished-0.98RC, Painted- 0.98RC) of the incident surface of the scintillator was compared. The effects of NaI(TI) scintillator thickness and the refractive index of light guide optically coupling between the NaI(TI) scintillator and photomultiplier tube (PMT) were simulated. We also evaluated intrinsic position resolution of the system by calculating the spread of scintillation light generated. The sensitivities of the system having the surface treatment of Ground, Polished, Metal-0.95RC, Polished-0.98RC and Painted-0.98RC were 70.9%, 73.9%, 78.6%, 80.1% and 85.2%, respectively, and the surface treatment of Painted-0.98RC allowed the highest sensitivity. As increasing the thickness of scintillation crystal and light guide, the sensitivity of the system was decreased. As the refractive index of light guide increases, the sensitivity was increased. The intrinsic position resolution of the system was estimated to be 1.2 mm in horizontal and vertical directions. In this study, the performance of NaI(TI)-PMT detector system was evaluated using Monte Carlo simulation. Based on the results, we concluded that the NaI(TI)-PMT detector array is a favorable configuration for small gamma camera imaging breast tumor using Tc-99m labeled radiopharmaceuticals.

  • PDF

Effects of Scintillation Crystal Surface Treatments on Small Gamma Camera Imaging (섬광체 옆 표면처리가 소형 감마카메라 영상에 미치는 효과)

  • Kim, J. H.;Choi, Y.;Kim, J. Y.;Oh, C. H.;Kim, S. E.;Choe, Y. S.;Lee, K. H.;Joo, K. S.;Kim, B. T.
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.6
    • /
    • pp.515-521
    • /
    • 1999
  • Scintillator crystal is an important part and detcrmines performance characteristics of the gamma camera. We investigated the offects of scintillation crystal surface treatment on gamma camera imaging. Nal(TI) and Csl(Tl) scintillators. 20 mm diameter and 10 mm thickness, applied with two different surface treatments, white and black reflcetors, were applied to Nal(Tl) and Csl(Ti). The optical properties of generated scintillation light were evaluated by Monte Carlo simulation method and by actual measurement using a position sensitive photomultiplier tube (PSPMT). We measured sensitivity, energy resolution and spatial resolution of gamma camera with the various scintillators coupled to a PSPMT. In the simulation. Nal(Tl)-white prosented the best sensitivity. In the measurements, the sensitivities and the intrinsic spatial resolutions of Nal(Tl)-white, Nal(Tl)-black. CsI(Tl)-white, CsI(Tl)-black were 2920, 2322, 1754, 1401 cps/$\mu$ci and 5.2, 4.5, 7.0, 6.3 mm FWHM. respectively. Their intrinsic energy resolutions were mesured 12.5, 23.5, 20.5, 33.3% FWHM at 140 keV Tc-99m. In this study, we investigated the offects of a side surface treatment of the scintillator on the gamma camera imaging. Simulation and measurement prescnted similat trends. Based on the results, we concluded that the surface of th NaI(Tl)seintillator must be treated by absorptive materials in order to develop the gamma camera having good spatial resolution.

  • PDF

Design of Photoelectric Photometer using Operational Amplifier (연산증폭기에 의한 광전측광장치의 설계)

  • 노홍조;김동진
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.9 no.4
    • /
    • pp.7-16
    • /
    • 1972
  • A prototype of photoelectric photometer has been developed by all solid state operational amplifiers. The amplification of low-level anode currents from photomultiplier tube corresponding to a given incident light intensity and logarithmic transfer for star's magnitude nleasurements are achieved by the same operational amplifier. It is important to select low input bias currents for stable performance because the resolution is primarily limited by the bias currents. As such, they offer a higher reliable and economical for a large number of electrometer amplifier applications which have traditionaly been fulfilled by vacuum electrometer tubes or vibrating reed electrometers.

  • PDF

Design and Manufacture of an Electron Detector for Scanning Electron Microscope (주사전자현미경용 전자검출기의 설계 및 제작)

  • Jeon, Jong-Up;Kim, Ji-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.4
    • /
    • pp.53-60
    • /
    • 2008
  • Electron detectors used in scanning electron microscope accept electrons emitted from the specimen and convert them to an electrical signal that, after amplification, is used to modulate the gray-level intensities on a cathode ray tube, producing an image of the specimen. Electron detector is one of the key components dominating the performance of scanning electron microscope so that the development of electron detectors having high performance is indispensable to acquire high quality images using scanning electron microscope. In this paper, we designed and manufactured an electron detector and conducted a couple of image capture experiments using it. In particular, scintillator which generates light photons when it is struck by high-energy electrons was manufactured and experimental studies on the optimization of manufacturing condition was carried out. From experiments to evaluate the performance of our detector, it was verified that the performance of our detector is equivalent to or better than that of the conventional one.

Absolute Measurement of the Quantum Efficiency of Photodetectors Using Correlated Photon Pairs (광자쌍을 이용한 광검출기의 양자효율 절대측정)

  • 안경진
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.452-456
    • /
    • 1993
  • The quantum efficiencies of photomultiplier tubes were measured by counting the coincidence photon pairs generated in the process of spontaneous parametric down-conversion. They were measured within 3% accuracy over the range of wavelength from 560 to 850 nm without any standard light source or detector. The values for 633 nm correspond to those obtained with a calibrated laser power meter within the measurement error.

  • PDF

Prebreakdown corona processes of point-to-plane gap in $SF_6$gas ($SF_6$ 가스중에서 침-평판간극의 전구코로나 과정)

  • 이복희;백용현
    • Electrical & Electronic Materials
    • /
    • v.5 no.1
    • /
    • pp.99-110
    • /
    • 1992
  • 본 논문은 고정된 바늘모양의 공기물에 의하여 형성된 불평등전계중에서 뇌임펄스전압에 대한 SF$_{6}$가스의 절연특성과 전구방전진전에 관한 것이다. 하전입자의 이동에 의하여 외부회로에 흐르는 전도전류의 측정방법에 대하여 기술하고 0.05~0.3[MPa]의 압력범위에서 섬락전압-압력특성을 측정하였으며 분류기와 광전자증배관을 사용하여 전구방전의 순시적 진전과정을 관측하였다. 전구방전은 돌기물의 선단에서 발생한 초기스트리머에 의하여 발단되며 정극성의 경우 섬락전압은 국부고전계에 매우 민감하며 리이더메카니즘으로 진전됨이 확인되었다. 전구방전현상의 극성의존성은 공간전하의 영향이 지배적이었다. 더불어 본 연구에서 제안된 전구전류의 측정기법은 불평등전계중에서의 전자사태전류, 코로나방전과 공극내에서의 부분방전의 측정에 매우 유용하게 적용될 것이다.

  • PDF

Development of Imaging Gamma Probe Using the Position Sensitive PMTube (위치 민감형 광전자증배관을 이용한 영상용 감마프로브의 개발)

  • Bong, Jeong-Gyun;Kim, Hui-Jung;So, Su-Gil;Kim, Han-Myeong;Lee, Jong-Du;Gwon, Su-Il
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.107-113
    • /
    • 1999
  • The purpose of this study was to develop a miniature imaging gamma probe with high performance that can detect small or residual tumors after surgery. Gamma probe detector system consists of NaI(Tl) scintillator, position sensitive photomultiplier tube (PSPMT), and collimator. PSPMT was optically coupled with 6.5 mm thick, 7.62 cm diameter of NaI(Tl) crystal and supplied with -1000V for high voltage. Parallel hexagonal hole collimator was manufactured for characteristics of 40-mm hole length, 1.3-mm hole diameter, and 0.22 mm septal thickness. Electronics consist of position and trigger signal readout systems. Position signals were obtained with summing, subtracting, and dividing circuit using preamplifer and amplifier. Trigger signals were obtained using summing amplifier, constant fraction discriminator, and gate and delay generator module with preamplifer. Data acquisition and processing were performed by Gamma-PF interface board inserted into pentium PC and PIP software. For imaging studies, flood and slit mask images were acquired using a point source. Two hole phantom images were also acquired with collimator. Intrinsic and system spatial resolutions were measured as 3.97 mm and 5.97 mm, respectively. In conclusion, Miniature gamma probe images based on the PSPMT showed good image quality, we conclude that the miniature imaging gamma probe was successfully developed and good image data were obtained. However, further studies will be required to optimize imaging characteristics.

  • PDF