• Title/Summary/Keyword: 광산갱도

Search Result 51, Processing Time 0.026 seconds

A Study on Evaluation of Thermal Environment using Heat Stress Indices for Deep Coal Mine in Korea (열적지표를 적용한 국내 고심도 석탄광산의 열환경 평가 연구)

  • Park, Seon-Oh;Roh, Jang-Hoon;Kim, Jin
    • Tunnel and Underground Space
    • /
    • v.24 no.2
    • /
    • pp.166-175
    • /
    • 2014
  • In this study, the thermal environment in a large scale coal mine located in Taebaek, Gangwondo was assessed by a field survey. In order to estimate the thermal environment, various heat stress indices such as WBGT, HSI, ESI, KATA index and effective temperature were investigated. Correlation analysis was also conducted. It was found that the thermal environment in most workplace was high. In particular, the correlation coefficient between HSI reflected in physiological fatigue characteristic and the maximum sweat evaporation heat was -0.834. This shows that the correlation coefficient have the most influence on HSI index. The factor which has the most influence on the maximum sweat evaporation heat is velocity of air. The thermal environment of high-depth coal mines is likely to be improved by installing a structure that enables the maximum prevention of extended digging, air doors, or the leakage of the inflow of air in the first shaft.

Geophysical Surveys for the Detection of Gallery and Geomembrane at the Imcheon Abandoned Mine (임천 폐광산의 지하갱도와 인공차수막의 탐지를 위한 지구물리탐사)

  • 김지수;한수형;이경주;최상훈
    • Economic and Environmental Geology
    • /
    • v.36 no.6
    • /
    • pp.501-510
    • /
    • 2003
  • Several geophysical surveys(electrical resistivity, electromagnetic, seismic refraction, CPR) were conducted to primarily investigate the gallery and the geomembrane at an abandoned mine(Imcheon mine). The subsurface structure mapped from seismic refraction survey mainly consists of three velocity layers(>1000 m/s, 1000∼2000 m/s,<2000 m/s). Top of the bedrock, whose velocities exceed 2000 m/s, appears to be at depth of 7.5∼10m. Higher resistivities (of ten thousands-hundred of thousands ohm-m) are interpreted to be associated with a open(cavities) gallery. The events at depth of approximately 0.5∼0.7m in GPR sections are probably caused by high-density-poly-ethylene geomembrane. Taking into consideration of the differences in the spatial resolution between georadar and electrical surveys, the events of geomembrane correspond to the top of the high resistivities at depth of about 2m. The segments, characterized with the higher conductivities in the electromagnetic data and the lower resistivities in the electrical resistivity data, are probably associated with surface water or tear zone of geomembrane.

A Case Study on the Ventilation and Heat Environment in a Underground Limestone Mine with Rampway (Rampway 설치 석회석 광산내 환기 현황 및 열환경 분석 사례연구)

  • Kim, Doo-Young;Lee, Seung-Ho;Jeong, Kyu-Hong;Lee, Chang-Woo
    • Tunnel and Underground Space
    • /
    • v.22 no.3
    • /
    • pp.163-172
    • /
    • 2012
  • As more diesel engines have been employed in underground limestone mines with large cross section, underground space environment is worsened by diesel exhausts and heat flow. This paper aims for the ultimate goal to optimize the work place environment through assuring the optimal required ventilation rate based on the analysis of the airflow, diesel exhaust gas concentrations and the effects of mechanization and deepening working face on temperature and humidity. Due to the insufficient capacity of the main exhaust fan and poor airway management, stagnant airflows were observed at various locations, while the flow direction was reversed instantly with passing diesel equipment and the flow reversal was also made by the seasonal variation of the outside surface weather. During the loading operation, CO concentration measurements were found to be frequently higher than the threshold limit of 50 ppm, and most of the $NO_2$ measurements during drilling and loading operations shows even more serious levels surpassing the permissible limit of 3 ppm. The actual ventilation quantity was considerably less than the required quantity estimated by the mine health and safety law, and this shortage problem was less serious in colder winter showing more effectiveness of the natural ventilation.

Exploration and Development in the Janggun Pb-Zn Mine (장군광산(將軍鑛山)의 탐사(探査)와 개발현황(開發現況))

  • Kho, Suck Jin
    • Economic and Environmental Geology
    • /
    • v.20 no.4
    • /
    • pp.289-303
    • /
    • 1987
  • 당(當) 광산(鑛山)은 1936년(年) 금(金), 은(銀) 광종(鑛種)으로 출원(出願)하였다가 1940년(年) 망간을 추가(追加)하여 망간 광산(鑛山)으로 1975년(年)까지 Mn(30~35%) 110,000여(餘)톤을 생산(生産), 국내생산량(國內生産量)의 70%를 점(占)하였고 1976년(年) Mn광상(鑛床) 하부(下部)에 연(鉛), 아연(亞鉛) 유화광(硫化鑛)을 발견(發見), 현재(現在)까지 Pb十Zn=10% 이상(以上) 원광석(原鑛石) 500,000여(餘)톤을 처리(處理), 연정광(鉛精鑛)(Pb : 62%) 37,000여(餘)톤, 아연정광(亞鉛精鑛)(Zn : 46.5%) 37,000여(餘)톤, 유비광정광(硫砒鑛精鑛)(As : 30%) 5,000여(餘)톤을 생산(生産)하였다. 현재(現在) 일처리(日處理) 220톤 선광장(選鑛場)을 일처리(日處理) 400톤 규모(規模)로 증설계획중(增設計劃中)이다. 당(當) 광산(鑛山)에서 현재(現在)까지 시행(施行)한 갱외시추(坑外試錐)는 75개공(個孔) 18,500여(餘)m, 갱내시추(坑內試錐) 750개공(個孔) 40,000여(餘)m 갱도(坑道) 총연장(總延長) 13,000m에 달(達)하며 지표(地表)(623ML)로 부터 수직(垂直) 300m 하부(下部)까지 갱도(坑道)가 개착(開鑿)되어 있다. 당(當) 광산(鑛山)의 지질(地質)은 여러 조사서(調査書)에 의(依)하여 견해(見解) 차이(差異)를 보여주고 있으나 대체(大體)로 다음과 같은 쪽으로 인정되고 있다. 즉(卽) 본지역(本地域) 루층군(累層群)의 층순(層順)을 하위(下位)로 부터 상위(上位)로 향(向)하여 원남층(遠南層)${\rightarrow}$율리통(栗里統)${\rightarrow}$장산규암층(壯山珪岩層)${\rightarrow}$두음리층(斗音里層)${\rightarrow}$장군석회암층(將軍石灰岩層)${\rightarrow}$동수곡층(東水谷層)${\rightarrow}$재산층(才山層)의 순위(順位)로 보며 장산규암층(壯山珪岩層)과 두음리층(斗音里層)을 조선계(朝鮮系)의 양덕통(陽德統)으로, 장군석회암층(將軍石灰岩層)을 대석회암통(大石灰岩統)으로, 동수곡층(東水谷層)과 함탄층(含炭層)인 재산층(才山層)을 평안계(平安系) 지층(地層)으로 대비(對比)한다. 이들은 본지역(本地域) 북(北)쪽에서는 선(先)캠브리아기(紀)의 원남층(遠南層)과 율리통(栗里統)을 불정합(不整合)으로 덮고 남측(南側)에서는 재산층(才山層)과 원남층(遠南層)이 단층접촉(斷層接觸)하고 있다. 이들 지층(地層)의 주향(走向)은 $N60^{\circ}{\sim}80^{\circ}W$, $N60^{\circ}{\sim}80^{\circ}E$이며 경사(傾斜)는 대체(大體)로 $50^{\circ}{\sim}80^{\circ}N$이며 전체적(全體的)으로 역전(逆轉)된 층서(層序)를 보여주는 바 지질구조(地質構造)에 있어서 단사구조(單斜構造)인지 등사(等斜)습곡의 향사(向斜), 또는 등사(等斜)습곡이 배사구조(背斜構造)인지 아직 밝혀지지 않고 있다. 화성암체(火成岩體)는 본지역(本地域) 서측(西側)에 쥬라기(紀) 춘양화강암(春陽花崗岩)이 불규칙(不規則)한 실입(實入) 접촉면(接觸面)을 보여주며 시대미상(時代未詳)(백악기(白堊紀)?)의 거정화강암(巨晶花崗岩), 반화강암(半花崗岩)이 소암주상(小岩株狀)으로 몇 곳 실입(實入)하고 산성(酸性)~중성(中性)의 맥암(脈岩)과 염기성(鹽基性) 안산암질암(安山岩質岩)이 실입(實入)해 있다. 광상(鑛床)은 장군석회암층(將軍石灰岩層)에 배태(胚胎)되어 있는 열수교대(熱水交代) 연(鉛), 아연(亞鉛), 은등(銀等)의 혼합(混合) 유화광상(硫化鑛床)으로 다량(多量)의 Mn분(分)을 수반(隨伴)하며 지표부(地表部)에 Mn광상(鑛床)을 형성(形成)하고 있다. 광상(鑛床)의 형태(形態)는 괴상(塊狀), 각력(角礫)pipe상(狀), 맥상(脈狀)으로 나타난다. 광상(鑛床)의 성인(成因)과 생성시기(生成時期)에 대(對)하여 많은 논란(論難)이 있다. 즉(卽) 열수교대(熱水交代)냐, 접촉교대(接觸交代)냐, 동시퇴적기원(同時堆積起源)이냐, 또는 생성시기(生成時期)가 쥬라기(紀)인지 백악기(白堊紀)인지에 대해 이론(異論)이 있다. 본지역(本地域) 광상(鑛床)은 남본(南本), 100우(右), 북(北), 유비철(硫砒鐵), 동(東), 서(西), 재남(才南), 재동(才東), 110호(號) 등(等)이 지표(地表) Mn로두광화대(露頭鑛化帶)와 관련(關聯) 명명(命名)된 바 전(前)4자(者)는 하부(下部)에서 유화광상(硫化鑛床)이 확인(確認)되었으나 나머지 후자(後者)에서는 아직 하부(下部)에 유화광상(硫化鑛床)이 확인(確認)되지 않고 있으며 남본광상(南本鑛床)으로 부터 남동(南東) 300여(餘)m 지점에 장군석회암층(將軍石灰岩層)과 동수곡층(東水谷層) 경계부(境界部)에 Fe 55~60% 자철광상(磁鐵鑛床)이 확인(確認)된 바 신례미(新禮美) 자철광상(磁鐵鑛床)과 유사성(類似性)이 있는 것 같아 흥미(興味)롭다. 당(當) 광산(鑛山)의 현재(現在)까지의 탐광(探鑛)은 남본광상(南本鑛床) 지표로두(地表露頭)(Mn) 하부(下部)에서 확인(確認)된 연(鉛), 아연(亞鉛), 은(銀) 유화광체(硫化鑛體) 하부(下部)와 전탐(電探)에 의(依)해 확인(確認)된 북광체(北鑛體), 갱도접근중(坑道接近中)에 확인(確認)된 100우광체(右鑛體), 유비철광체(硫砒鐵鑛體) 등(等)의 하부(下部) 탐광(探鑛)을 주(主)로 하고 지표(地表) Mn로두(露頭) 하부(下部)에 대(對)한 시추탐광(試錐探鑛0을 병행(竝行)하고 있으며 시추(試錐)에 의(依)해서 지표(地表)로 부터 790m 하부(下部)(해발(海拔) 200ML)까지 광화대(鑛化帶)가 확인(確認)되었다. 향후(向後) 탐광방침(探鑛方針)을 확고(確固)히 수립(樹立)하기 위(爲)하여는 광상(鑛床)의 성인구명(成因究明)은 물론(勿論) 광상(鑛床)의 배태조건(胚胎條件)에 있어 지질구조규제(地質構造規制)와 화강암(花崗岩)의 실입상(實入狀)과의 관계(關係), 광액(鑛液)의 통로(通路)에 대(對)한 지질구조(地質構造), 모암(母岩)의 화학(化學) 물리적(物理的) 특성(特性)에 대(對)한 연구(硏究) 검토(檢討)가 었어야 하겠다.

  • PDF

Environmental Contamination and Bioavailability Assessment of Heavy Metals in the Vicinity of the Dogok Au-Ag-Cu Mine (도곡(Au-Ag-Cu)광산 주변지역의 중금속 원소들의 환경오염특성 및 생체흡수도 평가)

  • Lee Sung-Eun;Lee Jin-soo;Chon Hyo-Taek
    • Economic and Environmental Geology
    • /
    • v.38 no.2 s.171
    • /
    • pp.135-142
    • /
    • 2005
  • In order to investigate the contamination level and seasonal variation of heavy metals and evaluate the bioavailability of toxic elements, environmental geochemical survey was undertaken at the Dogok Au-Ag-Cu mine area. The main pollution sources in the area were suggested as tailings, mine waste materials and mine water. Elevated levels of $140{\cal}mg/{\cal}kg{\;}As,{\;}107{\cal}mg/{\cal}kg{\;}Cd,{\;} 3017{\cal}mg/{\cal}kg{\;}Cu,{\;}12926{\cal}mg/{\cal}kg{\;}Pb,{\;}9094{\cal}mg/{\cal}kg$ Zn(before rainy season) were found in mine tailings. Concentrations of heavy metals in farmland soils exceeded normal level in nature soil (Bowen, 1979). The highest level of heavy metals was found in water samples near the mine tailing dumps regarded as a main pollution source of toxic elements in the area. These concentrations decreased to downstream due to the effect of dilution. From the results of sequential extraction analyses for tailings and soils, non-residual forms of heavy metals were found, which indicate the contamination to be progressing by continuing weathering and oxidation. Cadmium and Zn would be of the highest mobility in all samples. The bioavailability of Cd, Cu, Zn and As using SBET analysis from paddy soils was $53.3{\%},{\;}46.5{\%},{\;}41.0{\%}$ and $37.0\%$, respectively. The farmland soil sample(S3) showed the highest total concentration and bioavailability of heavy metals.

Venturi Effects Induced by the Local Ventilation Fan in Large-Opening Room-and-Pillar Mining Sites (대단면 갱내 국부 선풍기의 벤츄리(Venturi) 효과 연구)

  • Lee, Chang Woo;Nguyen, Van Duc
    • Tunnel and Underground Space
    • /
    • v.24 no.6
    • /
    • pp.464-472
    • /
    • 2014
  • In large-opening room-and-pillar mining sites, particularly without the devices for the ventilation control, the airflow pattern created by the local fan operation is too complicated to quantify and also shows low ventilation efficiency. This study aims at performing a series of CFD analysis for the so-called venturi effects of the local fans; the effects of increasing airflow rate along the axis downstream of fan resulting from increased kinetic energy and subsequently decreased static pressure in the downstream. Effects of the fan type and installation height are compared. 1 vane-axial fan and 2 propeller fans are analyzed for their venturi effects, while the vane-axial fan was installed at the height of 1.0, 1.5 and 2.0m for comparison. The results can be applied to improve the economy and efficiency of local fans for securing better air quality and work environment management.

Stability Assessment of Abandoned Gangway for Commercial Utilization of Services (서비스업 활용을 위한 광산 폐갱도의 안정성 평가)

  • SunWoo, Choon;Chung, So-Keul;Lee, Yun-Su;Kang, Sang-Soo;Kang, Jung-Seok
    • Tunnel and Underground Space
    • /
    • v.22 no.5
    • /
    • pp.297-309
    • /
    • 2012
  • The stability assessment of abandoned gangway for the purpose of services was performed. Among the many factors that affect the stability of openings, the span of the opening in a given rock mass condition provides an important element of design. In this paper, the stability of gangway was assessed by the critical span curves proposed by Lang, the modified Mathews'stability graph method and using support measures of the Q system. In the evaluation of stability as a whole the gangway is considered as stable. But the rockfalls of wedge-shaped blocks were expected in the area in which the horizontal joints of low angle appear. The support measures such as local rock bolts are required to use for commercial purposes of the abandoned gangway. And entrance section may require the particular attention as unstable section. Since there are so many spalling due to bad blasting in the roof and sidewall of gangway, the scaling operations should be followed primarily.

Numerical Study for Prediction of Rock Falls Around Jointed Limestone Underground Opening due to Blast Vibration (발파진동에 의한 절리암반 지하공동의 낙석발생 예측에 관한 수치해석적 연구)

  • Kim, Hyon-Soo;Kim, Seung-Kon;Cho, Sang-Ho
    • Explosives and Blasting
    • /
    • v.34 no.3
    • /
    • pp.10-16
    • /
    • 2016
  • Recently, transition from open pit to underground mining in limestone mines is an increasing trend in Korea due to environmental issues such as noise, dust and vibrations caused by crushers and equipment. The severe damages in the surrounding rock mass of underground opening caused by explosive blasting may lead to rock fall hazards or casualties. It is well known that variables which mainly affect blast-induced rock falls in underground mining are: blast vibration level, joint orientation and distribution and shape of the cross sections of underground structures. In this study, UDEC program, which is a DEM code, is used to simulate blast vibration-induced rock fall in underground openings. Variation of joint space, joint angle and joint normal stiffness was considered to investigate the effect of joint characteristics on the blast vibration-induced rock fall in underground opening. Finally, jointed rock mass models considering blast-induced damage zone were examined to simulate the critical blast vibration value which may cause rock falls in underground opening.

Experimental and CFD Study on the Exhaust Efficiency of a Smoke Control Fan in Blind Entry Development Sites (맹갱도 굴진 작업공간내 방재팬의 화재연 배기효율에 관한 현장실험 및 CFD 연구)

  • Nguyen, Vanduc;Kim, Dooyoung;Hur, Wonho;Lee, Changwoo
    • Tunnel and Underground Space
    • /
    • v.28 no.1
    • /
    • pp.38-58
    • /
    • 2018
  • The ventilation system plays a crucial role in underground mine safety. The main objective of the ventilation system is to supply sufficient air to dilute the contaminated air at working places and consequently provide tenable environment during the normal operation, while it also should be capable of controlling the fire propagation and facilitate rescue conditions in case of fire in mines. In this study, a smoke control fan was developed for the auxiliary ventilation as well as the fire smoke exhaust. It works as a free-standing auxiliary fan without tubing to dilute or exhaust the contaminated air from the working places. At the same time, it can be employed to extract the fire smoke. This paper aims to examine the smoke control efficiency of the fan when combined with the current ventilation system in mines. A series of the site experiments and numerical simulations were made to evaluate the fan performance in blind entry development sites. The tracer gas method with SF6 was applied to investigate the contaminant behavior at the study sites. The results of the site study at a large-opening limestone mine were compared with the CFD analysis results with respect to the airflow pattern and the gas concentration. This study shows that in blind development entry, the most polluted and risky place, the smoke fan can exhaust toxic gases or fire smoke effectively if it is properly combined with an additional common auxiliary fan. The venturi effect for smoke exhaust from the blind entry was also observed by the numerical analysis. The overall smoke control efficiency was found to be dependent on the fan location and operating method.

Analysis on the Ore Recovery from Operating the Room & Pillar Hybrid Mining Method in the Korean Limestone Mine (국내 석회석 광산에서 주방식하이브리드 채광법의 채수율 분석)

  • Kwon, Dukjoon;Kim, Jaedong
    • Tunnel and Underground Space
    • /
    • v.27 no.3
    • /
    • pp.161-171
    • /
    • 2017
  • Demand for high-grade limestone is increasing, but the production in the domestic mines has been limited due to the lack of systematic development plans and efforts to develop mining technology to improve the recovery ratio, transition to high-cost underground mining due to increasing social awareness of environmental protection, and the smallness of the domestic mining industry, etc. In this study in connection with this issue, an analysis on the recovery change by improvement of mining method was executed. 3D modeling technique was used to construct a 3D model. 3D model includes the geological structure, the limestone ore body and the underground pits and tunnels excavated at the Daepyeong District of Daesung MDI Donghae District. By using the 3D model, measured resources, reserves and ore recovery were evaluated from the results of pilot operation of the room and pillar hybrid mining method, which is a variant of room and pillar mining method. These results were compared with those obtained from the conventional mining method. The ore recovery obtained by hybrid mining method was found to be up to 71.6%, showing about 26%p. increase compared with the case of conventional mining method.