• Title/Summary/Keyword: 광도계

Search Result 163, Processing Time 0.026 seconds

Understanding of the color in composite resin (복합레진의 색에 대한 이해)

  • Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.4
    • /
    • pp.271-279
    • /
    • 2011
  • In clinic, esthetic restoration of a defective natural tooth with composite resin is challenging procedure and needs complete understanding of the color of tooth itself and materials used. The optical characteristics of the composites are different because the chemical compositions and microstructures are not same. This review provided basic knowledge of the color and the color measurement devices, and analyze the color of the natural tooth. Further, the accuracy of the shade tab, color of the composite resins before and after curing, effect of the water, food and bleaching agent, and translucency, opalescence, and fluorescence effects were evaluated.

Comparison of Polymer and BANGTM Gel Dosimeters to Use a Optical Computed Tomography Scanner (광학 전산화단층촬영 스캐너 사용을 위한 중합체 겔과 BANGTM 겔 선량계의 특성 비교)

  • Kyung Hwan Chang
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.107-114
    • /
    • 2023
  • The purpose of this study was to compare the basic radiological characteristics of in-house polymer gel and commercially-available gel (BANGTM) gel dosimeters with a spectro-photometer to use a optical computed tomography (CT) scanner. We investigated the radiological characteristics including dose linearity, absorbance spectrum, dose rate dependency and inter-and intra-reproducibility at wavelengths of 590, 600 and 630 nm. The optimal dose linearities of two gel dosimeters showed R2 value of 0.939 and 0.948 at wavelengths of 590 nm and 600 nm, respectively. For two polymer gel dosimeters, there is no peak sensitivity within the range of all wavelengths in absorbance spectrum. For in-house gel dosimeter, the dose rate dependency were within 5% for all wavelengths except for the dose rate of 100 MU/min. For BANGTM gel dosimeter, the dose rate dependency showed an error range of ±5% for all wavelengths. The inter-and intra-reproducibility of two gel dosimeters were within the range of 2.5%. We have confirmed that the two gel dosimeters was appropriate for use with a optical CT scanner.

Charge-Carrier Transport Properties and Fluorescence Behaviors Depending on Charge Transport Complex of Organic Photoconductor Containing Liquid Crystal (액정을 함유하는 유기 광도점체의 전하 수송착체에 의한 Charge-Carrier수송 특성과 형광거동)

  • Lee, Bong; Jung, Sung-Young;Moon, Doo-Dyung
    • Polymer(Korea)
    • /
    • v.25 no.5
    • /
    • pp.719-727
    • /
    • 2001
  • Recently it was found that the charge carrier transport properties are significantly enhanced due to effective intermolecular $\pi$-orbital overlapping and low disorder of hopping sites caused by self-organization of liquid crystal molecules. In this study, the xerographic properties of a double-layer photoconductor doped with nematic liquid crystal, 4-pentyl-4'-cyanoterphenyl (5CT), as a charge-carrier transport material to enhance the charge-tarrier mobility were investigated. From the results of measured surface voltage properties for the photoconductor doped with various concentrations of liquid crystal, 5CT, the initial voltage was found to increase with the concentration of 5CT and the dark decay decreased with the concentration of 5CT. The highest sensitivity was obtained at a specific concentration, 40wt% 5CT. The fluorescence behavior of the carrier transport layer (CTL) was also investigated. It was found that the charge-carrier transport properties of the organic photoconductor depend on the charge-carrier transport properties of the complex. The TNF : 5CT (40 wt%) and OXD : 5CT (40 wt%)samples showed the highest sensitivity because the greatest charge transport complex was termed between the charge-carrier transport materials in these samples.

  • PDF

육지초인용 고광도 LED 대형등명기 연구 개발

  • Song, Sang-Bin;Ju, Jae-Yeong;Sin, Gyeong-Ho;Lee, Dong-Hui;Kim, Sang-Yu;Yu, Seong-Hwan
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2015.10a
    • /
    • pp.322-323
    • /
    • 2015
  • Traditional rotation type large beacon was characterized by frequent failure, long repair time and high cost etc. These problems are caused by traditional light sources(metal halide lamps or tungsten halogen lamps). In order to solve these problems, IALA standards-based(efficiency and reliability) large LED beacon technologies are needed. we developed by applying a LED. The object of the this project, to design a reflective optics and the high power LED lighting engine module. And to develop a rotational speed control system for controlling flash pattern of beacon. As a result, to develop of LED beacon for landfall mark that distance to reach the light 20NM to 27NM.

  • PDF

Structural and Photoluminescence Properties of Sr1-1.5xMoO4:Eux3+ Phosphors

  • Ryu, Geun-Taek;Jo, Sin-Ho
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2012.05a
    • /
    • pp.195-195
    • /
    • 2012
  • $Eu^{3+}$ 이온의 농도비를 변화시키면서 고상 반응법을 사용하여 적색 형광체 $Sr_{1-1.5x}MoO_4:Eu_x{^{3+}}$ 분말을 합성하였다. 제조한 형광체의 결정 구조는 X-선 회절 장치를 사용하여 정방정계임을 확인하였고, 광학 특성은 형광 광도계를 사용하여 상온에서 측정하였다. $Eu^{3+}$ 이온의 농도비가 0.01 mol인 형광체의 경우에, 파장 295 nm로 여기시켰을 때 주된 발광은 파장 619 nm에 최대 세기를 갖는 적색 형광을 나타내었으며, 최대 흡수 스펙트럼은 넓은 밴드를 갖고 파장 302 nm에서 관측되었다.

  • PDF

Determination Of Optical Constants and Thickness of Weakly Absorbing Thin Films Using An Envelope Method (포락선 방법을 이용한 흡수가 작은 박막의 광학 상수 및 두께 결정)

  • 황보창권;진권휘;박대윤;이민희
    • Korean Journal of Optics and Photonics
    • /
    • v.3 no.1
    • /
    • pp.1-10
    • /
    • 1992
  • A simple formula of the envelope method, which uses two envelopes fitted to the transmittance at quarter- and half-wave optical thicknesses, is derived to determine the optical constants (refractive index and extinction coefficient) and the thickness of weakly absorbing thin films. We applied the envelope method to ZnS and SiOx films deposited in a vacuum chamber and determined the optical constants at different deposition conditions. For SiOx films, the decrease in refractive index is consistent with the increase in stoichiometry as the backfilled oxygen pressure increases.

  • PDF

THE LIGHT CURVE ANALYSIS OF AW CAM (AW CAM의 광도곡선 분석)

  • 김천휘;한원용
    • Journal of Astronomy and Space Sciences
    • /
    • v.12 no.1
    • /
    • pp.21-29
    • /
    • 1995
  • The $\beta$ Lyrae-type eclipsing binary AW Cam was observed photoelectrically in three wavelength regions. The obtained UBV light curves of AW Cam were analyzed with two separate modes(mode 2 for detached systems and mode 5 for semi-detached ones) of the Wilson-Devinney binary mode. It is intended to resolve the discrepancy in AW Cam system that the photometrio mass ratio (q=0.21) derived by Russo and Milano (1983) is not consistent with the spectroscopic result (q=0.43) by Mammano et al.(1967). Our photomtric solutions derived with mode 2 are fitted better to the observed light curves than those of mode 5, supporting that AW Cam may be not a normal semi-detached system but a detached one. Three dimensional Roche configuration of AW Cam system calculated with the derived mass ratio (q=0.43) reveals that the less massive secondary with the confined within its inner Roche lobe, while the more massive rimary is in marginally contact. From the Roche geometry, the constancy of the orbital period and other photometric evidences of AW Cam, it is provisionally concluded that the system is an unevolved detached binary in is provisionally concluded that the system is an unevolved detached binary in the phase of case A evolution toward 'contact phase' rather than and evolved one in 'broken-contact phase' suggested by Giuricin and Mardrossian (1981).

  • PDF

SI-traceable Calibration of a Transmissometer for Meteorological Optical Range (MOR) Observation (기상관측용 투과형 시정계의 국제단위계에 소급하는 교정)

  • Park, Seongchong;Lee, Dong-Hoon;Kim, Yong-Gyoo
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.2
    • /
    • pp.73-82
    • /
    • 2015
  • This work demonstrates the indoor SI-traceable calibration of a transmissometer with a 75-m baseline for the measurement of visibility in MOR (Meteorological Optical Range). The calibration is performed using a set of neutral density (ND) filters (OD 0.1-2.5) and a set of high-transmission quartz glass plates (a bare quartz glass plate and antireflective-coated quartz glass plates), the collection consisting of 20 artifacts in total. The luminous transmittance values of the reference artifacts had been calibrated traceable to the KRISS spectral transmittance scale, which ranges from 0.2 % to 99.5 %. The transmissometer to be calibrated typically consists of a loosely collimated light source based on a white LED (CCT ~5000 K) and a luminous intensity detector with a CIE 1924 V(${\lambda}$) spectral response. As a result of calibration, we obtained the MOR error and its uncertainty for the transmissometer in 20 m - 40 km of MOR. Based on the results, we investigated the applicability of the calibration method and the conformity of the transmissometer to the ICAO's (International Civil Aviation Organization) accuracy requirement for meteorological visibility measurement. We expect that this work will establish the standard procedure for the SI-traceable calibration of a transmissometer.

Development of a Measuring Instrument for the Coefficient of Luminous Intensity of Retro-Reflection of Miniature Telecentric Cameras (소형 텔레센트릭 카메라 광학계의 재귀반사 측정 방법 연구 및 측정 장치 개발)

  • Yeo, TaeWoon;Karasik, V.E.;Kim, Young Il
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.6
    • /
    • pp.334-339
    • /
    • 2014
  • In this paper, the optical properties of a miniature telecentric camera are studied analytically and experimentally. By means of optical properties, the luminous intensity of retro-reflection of a miniature telecentric optical system is investigated. First, from a simulation the theoretical value of the coefficient of luminous intensity of retro-reflection of a miniature telecentric system is estimated. Second, a miniature telecentric camera device is designed, and the value of the coefficient of luminous intensity of retro-reflection of the actual device is measured through experiment. From simulation and experiment, we found that both the estimated and observed values of the coefficient of luminous intensity of retro-reflection range from 0.002 to $0.03m^2/sr$ (P384200CPH: $0.0042-0.018m^2/sr$, P285200CPH: $0.0045-0.0297m^2/sr$, P321450S: $0.0021-0.00963m^2/sr$) at 1.4 to 4.9 arcminute. The results prove the significance of the mechanisms used to design the miniature telecentric camera, and the experimental method. Accordingly, with these significant results, this study contributes to the development of theory and practice in optical engineering science.

Comparison of Analytical Methods for DEHP Migration from PVC Bags for Blood Storage and Infusion; By Gas Chromatography and UV-vis Spectrophotometry (혈액·수액용 PVC 백에서 용출된 DEHP의 검출 분석 방법 비교; 기체 크로마토그래프와 분광 광도계)

  • Kim, Jung Hwan;Kim, Seong Hun;Choi, Hyeong Ki;Lee, Chang Hyung
    • Analytical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.72-79
    • /
    • 2002
  • Di-(2-ethylhexyl)phthalate (DEHP) may be released from plasticized poly(vinyl chloride) (PVC) articles. In the cases of various methods for the quantitative analysis of migrating DEHP, there are much differences in migrating quantity according to the experimental methods. It is therefore important to make the comparison and analysis between these two results. A study of DEHP migration from blood and infusion bags has been carried out in different methods to evaluate the amount of DEHP migration using gas chromatograph and UV-vis spectrophotometry. Five PVC bags were cut into plane sheets in size of $40{\times}10{\times}0.4mm$, then were immersed in extraction solvent for an hour to release DEHP. It was determined by a gas chromatograph that $23.2{\sim}70.9{\mu}g/mL$ of DEHP was extracted. While extraction solvent was injected into PVC bags which were then placed for an hour to leach DEHP out. It was checked by a UV-vis spectrophotometer that the concentration of DEHP in extraction solvent was $24.8{\sim}41.3{\mu}g/mL$. Two results show different values according to the extraction conditions and experimental methods and the gas chromatographic results were converted into UV-vis spectroscopic results on condition that DEHP would be extracted equally per unit time and unit contact area. It was concluded that DEHP migrating amounts are approximately equal in two analytical methods.