• Title/Summary/Keyword: 관절경적

Search Result 570, Processing Time 0.025 seconds

Arthroscopic Technique of Partial Meniscectomy for Bucket Handle Tear of Medial Meniscus using Posteromedial Portal (내측 반월상 연골판 양동이형 파열의 후내측 도달법을 이용한 관절경적 부분 절제술 - 수술 수기 -)

  • Ahn, Jin-Hwan;Lee, Jong-Yoon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.4 no.1
    • /
    • pp.71-75
    • /
    • 2000
  • Purpose : To introduce arthroscopic partial meniscectomy fur bucket handle tear of medial meniscus using posteromedial portal, which is superior to arthroscopic partial meniscectomy using standard anterior portals commonly used. Method : After arthroscopic examination of the knee, we reduce the torn meniscus, advance the arthroscope into posteromedial compartment under arthroscopic visualization, we make posteromedial portal with reexamination of the compartment and perform arthroscopic partial meniscectomy. Conclusion : With the technique of arthroscopic partial meniscectomy using standard anterior portals, accurate partial meniscectomy can not be done because of inadequate visual field, associated meniscal injuries of posterior horn and cartilage lesion of posterior aspect of the medial femoral condyle can be missed, commonly posterior cruciate ligament can be injured and artificial damage to weight bearing surface of medial femoral condyle is possible. An arthroscopic partial meniscectomy using posteromedial portal is an excellent method fur bucket handle tear of medial meniscus.

  • PDF

Treatment of the Septic Shoulder after Arthroscopic Rotator Cuff Repair in Diabetes Mellitus - A Case Report - (당뇨병 환자에서 관절경적 회전근 개 봉합술 후 발생한 화농성 견관절염의 치료 - 증례 보고 -)

  • Park, Jae-Hyun;Choi, Won-Ki;Kim, Se-Sik;Choi, Chang-Hyuk
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.72-76
    • /
    • 2009
  • Two diabetes mellitus patients treated by arthroscopy and associated procedure for an infection after arthroscopic rotator cuff repair were involved. The time interval from rotator cuff repair to symptom development was 18 days in average and arthroscopic debridement and associated procedure for infection applied in average 65 days after symptom development. Patient evaluation was done according to the KSS, ASES, UCLA and Constant Score. We used antibiotics for average 22.5 days after arthroscopic debridement and associated procedure, the infection was treated in average 4 months. At final follow-up, the mean KSS score was 82 points, the mean UCLA score was 33 points, the mean ASES score was 91 points, the mean Constant score was 71 points. All infections following arthroscopic rotator cuff repair were cured by arthroscopy and associated procedure. ROM and functional results were much improved, the pain and satisfaction were also much improved.

  • PDF

Arthroscopic Repair of the Postero-medial or Postero-lateral Capsule Tear in the Knee Joint - Technical Note - (슬관절 후내측 혹은 후외측 관절막 파열의 관절경적 봉합술 - 수술 수기 -)

  • Ahn Jin-Hwan;Cho Yang-Bum;Lee Yong-Seuk
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.2
    • /
    • pp.135-139
    • /
    • 2001
  • Purpose : Repair of the posterior capsule tear at the time of the operation for the chronic postero-lateral or postero-medial rotary instability has not been reported. We describe the arthroscopic repair of the posterior capsule tear using the posterior trans-septal portal. Method : After conducting basic arthroscopic examination of the knee, postero-medial and postero-lateral portals are secure to make the posterior trans-septal portal, through which the postero-medial and postero-lateral capsule tears are repaired using the suture hook under the arthroscopic guidance. Conclusion : When arthroscopic reconstruction of PCL insufficiency or postero-lateral rotaty instability that accompanies postero-medial or postero-lateral capsular tears. rising the posterior traits-septal portal could ensure better visualization of the capsule and a subsequent more accurate repair of the capsule. Since it significantly lessened instability, it could contribute to an achievement of successful clinical results.

  • PDF

Current Concept of Anterior Shoulder Instability Repair (견관절 전방 불안정성의 봉합술에 대한 최신 지견)

  • Kim, Young-Kyu
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.1
    • /
    • pp.1-7
    • /
    • 2006
  • 견관절 전방 불안정성의 관절경적 치료는 환자 개개인의 병리 상태를 잘 파악하여 적절한 복원술을 시행함으로써 보다 좋은 결과를 기대할 수 있다. 현재 관절경적 Bankart 복원술시 봉합 나사못이 가장 이상적인 봉합기구로 알려져 있으며 여러 병리 상태를 고려하여 관절경적 복원술을 시행한 결과 여러 학자들이 과거에 비해 좋은 결과를 보고하고 있다(Table 2). 따라서 술기상으로 보다 숙련된 술식을 통해 재발율을 낮출 수 있으며 보다 좋은 결과를 얻기 위하여 수술 후 적극적인 재활 프로그램이 요할 것으로 생각된다.

  • PDF

Arthroscopic Treatment of Calcific Tendinitis of Subscapularis Tendon - A Case Report - (견갑하근 건에 발생한 석회화 건염의 관절경적 치료 - 증례 보고 -)

  • Yi, Woo-Jin;Lee, Kwan-Hee;Jang, Won-Hee
    • Journal of the Korean Arthroscopy Society
    • /
    • v.17 no.1
    • /
    • pp.56-60
    • /
    • 2013
  • Calcific tendinitis of rotator cuff is a common disease which could be the cause of shoulder pain, and frequently occurs in supraspinatus, infraspinatus and teres minor in descending order. Calcific tendinitis of subscapularis is rare and arthroscopic treatment of that has also been rarely reported. So, we report a case of arthroscopic treatment of calcific tendinitis of subscapularis with excellent result.

  • PDF

Arthroscopic Retrieval Analysis for Intra-articular Foreign Body of the Knee Joint (슬관절내 이물질에 대한 관절경적 제거술식의 분석)

  • Lee, Byung-Ill;Choi, Hyung-Suk;Jo, Joo-Hyoung;Kwon, Sai-Won
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.211-216
    • /
    • 2008
  • Purpose: The frequency of foreign body in the knee joint is not as high, but it sometimes required wide or multiple arthrotomy in order to remove, which can baffle the surgeon in some ways. Our study is to evaluate for effectiveness of arthroscopic retrieval for intra-articular foreign body in the knee joint. Materials and Methods: The 22 patients(16 males, 6 females) had received arthroscopic foreign body retrieval in the knee joint from March 1983 to September 2006. The causes of foreign bodies of the knee joint were 7 of trauma (31.9%) related cases, 13 of surgery related cases (59.0%), 2 found during follow up after operation (8.1%) in pathologies of foreign body. Results: There were 15 of metal showed the most percentage (68.1%), 7 of non-metal (31.9%) in types of foreign bodies, and others included bullet, suture material, pencil lead, broken wire etc. All cases were used by arthroscopic techniques. All foreign bodies were removed easily and were showed no complication such as postoperative joint stiffness. Conclusion: Arthroscopic foreign body retrieval in the knee joint is effective surgery in terms of easy access to foreign body and less postoperative complication.

  • PDF