• Title/Summary/Keyword: 공장

Search Result 4,988, Processing Time 0.037 seconds

Estimated EC by the Total Amount of Equivalent Ion and Ion Balance Model (등가 이온 총량에 따른 EC 추정과 이온 균형 모형)

  • Soh, Jae-Woo;Lee, Yong-Beom
    • Horticultural Science & Technology
    • /
    • v.30 no.6
    • /
    • pp.694-699
    • /
    • 2012
  • To examine the EC model in a culture medium, basic culture medium of Rush (2005) and EC model of Robinson and Strokes (1959) were applied analyzing the equivalence ion total amount, the EC variable of cation and anion. Following the experiential translation by Steiner (1980), 130 optimized domestic and foreign culture media for crop growth were utilized, and estimated EC model was also demonstrated. Results from basic culture medium of Rush (2005) suggests an estimated EC by equivalence ion total amount and high reliable regressive model with 0.96 y = 1.33x - 0.23 of 0.96 as value $R^2$. It was found out that the change in concentration of positive ion and anion did not differ significantly with the increase and decrease of EC, however, there occurred a slight variable range. The change brings about a bigger anion influence than the previously reported positive ion, seemingly like those based on nitride ion and sulfur ion. The above EC estimated models confirmed that with optimized 130 domestic and foreign culture media for crop growth, the value derived will be as follows: $R^2$ = 0.98 with y = 1.23x - 0.02. In addition, the contour analysis of positive ion and anion for EC, with popularly known concentration range of EC $1.5-2.5dS{\cdot}m^{-1}$ reveals an equivalent of more than $11meq{\cdot}L^{-1}$ for positive ion and $15meq{\cdot}L^{-1}$ for anion. On the other hand, the left bottom, low concentration $1.5dS{\cdot}m^{-1}$ and the right above, high concentration $2.5dS{\cdot}m^{-1}$, for both positive ion and anion existed differently in a proper culture medium concentration. This study adapted variables of both positive ion and anion of EC simultaneously, unlike in the previous culture medium by ion ratio in mutual ratio of Steiner (1980), and offers an EC model that can estimate levels or positive ion and anion in proper concentration, EC $1.5-2.5dS{\cdot}m^{-1}$, with distributed features of ions.

Characteristics of Groundwater Quality in Sasang Industrial Area, Busan Metropolitan City (부산시 사상공단지역의 지하수 수질 특성)

  • Hamm, Se-Yeong;Kim, Kwang-Sung;Lee, Jeong-Hwan;Cheong, Jae-Yeol;Sung, Ig-Hwan;Jang, Seong
    • Economic and Environmental Geology
    • /
    • v.39 no.6 s.181
    • /
    • pp.753-770
    • /
    • 2006
  • In urban areas, groundwater pollution is heavily affected by urbanization with land use types. This study aims to characterize groundwater quality and contamination in Sasang industrial area of Busan Metropolitan City where metalworking, machinery and footwear factories are located. Busan Metropolitan City is the highest in the utilization of groundwater resources among the metropolitan cities in Korea. $K^+,\;Na^+,\;Ca^{2+},\;Mg^{2+},\;Cl^-,\;SO_4^{2-}\;and\;HCO_3^-$ concentrations, and electrical conductivity (EC), total dissolved solids (TDS) and salinity are high in the areas near the Nakdong River. The results are attributed to the influence of salt water which intruded into the coastal sediments during sedimentation. In addition, the dominant chemical type of Ca-Cl indicates the influence of salt water in the geological formations as well as anthropogenic pollution. $SiO_2$ ion is interpreted to originate from both water-silicate mineral reactions and the decomposition of cement concretes. Trichloroethylene (TCE) was detected at 12 sites of total 18 sites. However, tetrachloroethylene (PCE) was detected at f sites and 1.1.1-trichloroethane (TCA) at 3 sites. According to the factor analysis, factor 1 was explained by 49.8%, factor 2 19.8%, and factor 3 11.0% with total 80.6% explanation. pH, TDS, salinity, $Ca^{2+},\;K^+,\;Mg^{2+},\;Na^+,\;Al^{3+},\;As^{3+},\;Cl^-\;and\;Fe^{2+}$ were positively highly loaded to factor 1. The chemical components loaded to factor 1 represent the chemical characteristics of both industrial pollution and influence by salt water. Based on the cluster analysis and distribution pattern of chemical components, the concentration of $Na^+,\;Ca^{2+},\;Cl^-,\;SO_4^{2-}\;K^+,\;and\;Mg^{2+}$ is high in the riverside area of the Nakdong River composed of coastal sediments that is influenced by salt water. The downstream area of the Hakjang Stream is judged to be affected by both salt water and artificial pollution. The other part of the study area is interpreted by anthropogenic pollution.

Geochemical and Isotopic Study of the Kumho River (금호강 하천수의 지구화학 및 동위원소 연구)

  • Kim, Yeong-Kyoo;Nam, Eun-Kyung
    • Economic and Environmental Geology
    • /
    • v.42 no.6
    • /
    • pp.527-539
    • /
    • 2009
  • The Kumho River flows through volcanic and sedimentary rocks at upstream and downstream regions and also through industrial district including dyeing complex before it meets the Nakdong River, and as a result, many factors can influence the geochemistry of river water. The concentrations of dissolved ions generally increased as it flows downstream. The concentrations of cations are in the order of Ca>Na>Mg>K, and those of anions are $HCO_3$>$SO_4$>Cl>$NO_3$. These results show that the weathering of sandstone and shale containing carbonate including calcite caused the enrichment of Ca and $HCO_3$. At first 4 sampling sites, Si contents are relatively high mainly due to the weathering of silicate minerals of volcanic rocks. However, Na and $SO_4$ contents are higher at downstream sites due to the industrial and municipal sewage. Piper diagram also shows that the geochemical patterns changed from Ca-$HCO_3$ to Ca-Cl/Ca-$SO_4$ and Na-Cl/Na-$SO_4$ type. When comparing the samples collected in May and July, the concentrations of dissolved ions in July are generally lower than those in May, which indicates that dilution by precipitation played an important role. In July the relative concentration of Ca increased, indicating that Ca in soils probably from fertilizer were mixed into the river water by precipitation. The river waters are mainly from precipitation. The dissolved ions are mainly from weathering of carbonate minerals and pollutants from municipal sewage and discharged water from industrial complex. The composition of oxygen and deutrium isotope in July showed higher values, which is contrary to the amount effect, maybe due to Youngchon Dam. The nitrogen isotope showed lower values in July than those in May, which can be interpreted to indicate mixing of nitrate from soils and fertilizer in the cultivated land by the heavy rain. The isotope composition of nitrate increased downstream, indicating that the influence of sewage and animal manure also increased downstream.

Studies on LED Wavelength to Enhance Growth and Bio-active Compounds of Carrots (당근의 성장과 생리활성물질 함량을 증진시키는 LED 파장에 관한 연구)

  • Kang, Suna;Kim, Min-Jung;Kim, Bong Soo;Park, Sunmin
    • Journal of Applied Biological Chemistry
    • /
    • v.58 no.2
    • /
    • pp.131-137
    • /
    • 2015
  • Commercial greenhouse plant factories are highly efficient for controlling external factors such as floods, drought, insects, air pollution etc. However, they require substantial startup & maintenance investments and experimental research to optimize production. These facilities are especially useful for urban farming where high efficiency in small spaces is required. In this study, we investigated whether light emitting diode (LED) lights with mixed dominant wavelengths (650 nm : 550 nm : 445 nm=8:1:1, 650 nm : 445 nm=6:4) can increase the growth rate and bio-active compound content of carrots in comparison to that of fluorescent light (FL). LED with mixed wavelength (650 nm : 550 nm : 445 nm=8:1:1) increased the total weight and root circumference of carrots compared to FL. However, ${\beta}$-carotene contents were not significant in LED (650 nm : 550 nm : 445 nm=8:1:1). However, LED (650 nm : 445 nm=6:4) increased the ${\beta}$-carotene (FL: 7.27, LED: 10.48 mg/g ${\beta}$-carotene dried weight). These results suggested that using LED light at the ideal wavelength, at the antithesis color of the plant, might enhance plant growth and bio-active compound contents.

Four-Wheel Tractor Utilization in Korea(II) -Repair and Maintenance- (농용(農用) 트랙터 이용(利用)에 관(關)한 조사연구(調査硏究)(II) -고장(故障) 및 수리실태분석(修理實態分析)-)

  • Park, Ho Seok;Lee, Yong Kook
    • Journal of Biosystems Engineering
    • /
    • v.6 no.2
    • /
    • pp.65-76
    • /
    • 1982
  • This survey was conducted to investigate the status of repair and maintenance of 4 wheel tractor for a basic reference to the improvement of quality and proper utilization of tractors. Thirty two counties from eight provinces, except Jeju, were covered in this study in order to investigate annual break-down and repair of tractor in 1980. The analyzed results are summarized as follows; 1. The average number of break-down of large size tractors(47ps) was 5.0 times in a year and it was about twice of that of small size tractors(19-23ps). The break-down frequency per 100 hours of use was 1.11 times in the large size and 0.65 times in the small size tractors. 2. 75.6 percent of total break-down was occured in main body of tractor and 24.4 percent in attachments. In particular, the break-down of plow and rotavator was more than 80 percent of total break-down of the small size tractor attachments. 3. The large size tractors which were occured more than one times of break-down a year was 75 percent and its rate of the small size tractor was 62 percent. But 9 percent of tractor surveyed had more than ten times of break-down in a year 4. The frequency of break-down had a peak in May, and it was directly proportional to the hours of use. 5. The causes of break-down were poor maintenance and operation by 29.8 precent, old parts by 30.2 percent, poor quality of parts by 20.6 percent, poor field condition by 16.3 percent and others by 3.1 percent. 6. Annual number of repair was 5.5 times and among them 55.6 percent was done by shop and 44.4 percent by operator. 7. Total required repair time was 30.6 hours a year in the large size tractor and 19.9 hours in the small size tractor. Average repair time was 3.62 hours a time. 8. Annual repair cost was 278 thousand won in the large size tractor and 70 thousand won in the small size tractor. The repair cost per hour of use was 621 won in the large size and 198 won in the small size tractor. 9. The repair cost rate of tractor(Y) was regulated with tractor age (X) as follow; Y=0.752X In case of the service life of tractor was 10 years, the total repair cost rate was 64 percent.

  • PDF

Variation of Cadmium and Zinc Content in Rice and Soil of the Mangyeong River Area (만경강 유역의 토양과 수도체중 Cd 및 Zn 함량의 변화)

  • Kim, Seong-Jo;Baek, Seung-Hwa;Kim, Un-Sung;Yoon, Ki-Woun;Moon, Kwang-Hyun;Kang, Gyeong-Won
    • Korean Journal of Environmental Agriculture
    • /
    • v.13 no.2
    • /
    • pp.142-150
    • /
    • 1994
  • To investigate differences in Cd and Zn contents of paddy soils and rice plants polluted by the municipal and industrial waste water in the Mangyeong River Area, soil and plant samples were collected at several distances from the main inlet and at different depths of the soil. Soil samples were extracted with $4M-HNO_3$ and plant samples were digested with a mixture of $HNO_3$and $HClO_4$for analyzing heavy metals by atomic absorption spectrophotometry. The contents of Cd and Zn in soils ranged from 0.38 to 1.17 and from 33.8 to 464.6mg kg^{-1}, respectively. The average Cd level in 1990 was less than that in 1982, but the Zn level in 1990 was higher than that in 1982 in general. No variation in Cd contents was observed in soils at the different distances from the source of waste water, but Zn contents in soils were lower with the increasing distances from the source of waste water. A significant correlation was observed among Cd content, OM, available silicate, CEC and $Ca^{++}$. Similar results existed among Zn content of 1982, OM and $Ca^{++}$. The Cd content in subsurface soils of 1992 was significantly correlated with Zn, Cu, and Pb in soils, and the Zn content in soils was significantly correlated with the Cu and Pb in soils, regardless of years. The Cd content in leaf blades of rice was more than seven times higher than that in brown rice. The Zn content in rice was higher than that in leaf blades and in panicle axis. The Cd content in panicle axis and the Zn content in all parts of rice were correlated with Zn, Cu and Pb contents in soils. The Cd and Zn contents in brown rice ranged from 0.10 to 0.90mg $kg^{-1}$ and from 4.2 to 95.9mg $kg^{-1}$ in the Mangyeong River Area, respectively.

  • PDF

A Study on the Characteristics of Water Pollution in Rural Areas (농촌유역(農村流域)에서의 수질오염(水質汚染) 특성(特性)에 관한 연구(硏究))

  • Kim, Han-Tea;Kwun, Soon-Kuk
    • Korean Journal of Environmental Agriculture
    • /
    • v.12 no.2
    • /
    • pp.129-143
    • /
    • 1993
  • The objective of this study is to understand the status of the water pollution in rural areas and to furnish a basic material for the management of the water pollution in rural areas. For this purpose, the Bokha river basin, Ichon-Gun, Kyungki-Do considering as a typical agricultural area was selected as a representative experimental watershed. The characteristics of water pollution in streams of the Bokha river basin was revealed by investigating and analyzing data collected for the source of pollution, water qualities in reaches of the stream, the degree of contribution to the river contamination by pollution mass produced from each source, and the status of the self-purification at the main stream. The most important source of the water pollution in investigated watershed was livestock, and the next important one were in the order of population, land use, and industry. The water quality of the Bokha river was relatively favorable judging from the BOD and COD concentration, however since the concentration of T-N and T-P showed significantly large values, it was concluded that the river was seriously contaminated by the nutrient material. The main cause of the river contamination was proved due to livestock waste. For the T-N, both land use and livestock were much more contributied to the pollution than any other source, which characterized the typical water pollution of rural areas. Run-off ratios for the Bokha river tributaries to the main stream were changed according to the similar trend to the variation of discharges in the branch streams. For the value of the self-purification constant at the main stream, it showed smaller value in the downstream reach than the middle-stream and upstream reaches, where could possibly have smaller reoxidation action due to slower velocity and deeper water depth.

  • PDF

Standardization of Identification-number for Processed Food in Food-traceability-system (가공식품에 대한 이력추적관리번호 부여체계의 표준화 방안)

  • Choi, Joon-Ho
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.2
    • /
    • pp.194-201
    • /
    • 2012
  • Facing a number of global food-related accidents, the concept and system for food traceability have been designed and introduced in many countries to manage the food-safety risks. To connect and harmonize the various food traceability-information in food traceability system according to the food supply chain, the coding system of identification-number for food-traceability has to be standardized. The GTIN (Global Trade Item Number) barcode system which has been globally standardized and implemented, is reviewed with the mandatory food-labeling regulation in expiration date of processed foods. The integration of GTIN-13 bar-code system for food-traceability is a crucial factor to expand its function in the food-related industrial areas. In this literature, the standard coding system of identification-number for food-traceability is proposed with 20 digit coding number which is combined with GTIN-13 bar-code (13 digit), expiration date (6 digit), and additional classification code (1 digit). This proposed standard coding system for identification-number has a several advantages in application for prohibiting the sale of hazard goods, food-recall, and inquiring food traceability-information. And also, this proposed coding system could enhance the food traceability system by communicating and harmonizing the information with the national network such as UNI-PASS and electronic Tax-invoice system. For the global application, the identification-number for food-traceability needs to be cooperated with the upcoming global standards such as GTIN-128 bar-code and GS1 DataBar.

Exploration of Virulence Markers and Genes of Listeria monocytogenes Isolated from Animal Products (축산물유래 Listeria monocytogenes의 virulence marker 및 gene 조사)

  • Yi, Chul-Hyeon;Song, Hyeon-Ho;Kim, Mi-Ryung;Kang, Ho-Jo;Son, Won-Geun
    • Journal of Food Hygiene and Safety
    • /
    • v.23 no.3
    • /
    • pp.248-256
    • /
    • 2008
  • To investigate the epidemiological characteristics of 68 Listeria monocytogenes isolates, including 11 reference strains and 57 isolates from imported US beef, domestic meats(beef, pork, chicken meat), raw milk, and milk plants. L. monocytogenes was to evaluate the production of virulence proteins, such as hemolysin(LLO) and lecithinase(LCP), the adsorption of Congo red(CRA), and to detect virulence genes using the polymerase chain reaction(PCR). In the study of virulence protein production, 68(100%), 62(91.2%), and 54(79.4%) of the 68 L. monocytogenes strains were positive for LLO production, the LCP test, and the CRA test, respectively, while strains of other species, such as L. innocua, L. gray, L. murrayi, and L. welshimeri, were not. There were no significant differences between L. monocytogenes serotypes and the ability to produce LLO or LCP. L. monocytogenesstrains had very high hemolytic titers(2 to 16 fold), while the other Listeria species, other than L. ivanovii and L. seeligeri, did not. The hemolysin activities of L. monocytogenes, L. ivanovii, and L. seeligeri usually exceeded 1.0 HU/mg, while those of other Listeria spp. were less than 0.04 HU/mg. In the PCR assay, all of the L. monocytogenes strains contained the hlyA, plcA, plcB, inlA, and inlB virulence genes and produced a product of the expected size. In the PCR of the actA gene, the expected 385-bp product was seen in 39(57.4%) L. monocytogenesstrains, while an unexpected 268-bp product was seen in 29(42.6%) strains. Most L. monocytogenes strains isolated from Hanwoo beef produced the 385-bp actA gene product, while strains of imported US beef usually produced the 268-bp actA gene product. By contrast, no virulence gene products were amplified in the other Listeria spp.

Decomposition of odor using atmospheric-pressure plasma (플라즈마를 이용한 악취물질 분해 특성)

  • Kang, Seok-Won;Lee, Jae-Sik;Lee, Kang-San;Lim, Hee-Ah;Kim, Ji-Seong;Lee, Jeong-Dae;Park, Wol-Su;Park, Young-Koo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.7
    • /
    • pp.708-718
    • /
    • 2020
  • Offensive odor is recognized as a social environmental problem due to its olfactory effects. Ammonia(NH3), hydrogen sulfide(H2S) and benzene(C6H6) are produced from various petrochemical plants, public sewage treatment plants, public livestock wastes, and food waste disposal facilities in large quantities. Therefore efficient decomposition of offensive odor is needed. In this study, the removal efficiency of atmospheric-pressure plasma operating at an ambient condition was investigated by evaluating the concentrations at upflow and downflow between the plasma reactor. The decomposition of offensive odor using plasma is based on the mechanism of photochemical oxidation of offensive odor using free radical and ozone(O3) generated when discharging plasma, which enables the decomposition of offensive odor at ordinary temperature and has the advantage of no secondary pollutants. As a result, all three odor substances were completely decontaminated within 1 minute as soon as discharging the plasma up to 500 W. This result confirms that high concentration odors or mixed odor materials can be reduced using atmospheric-pressure plasma.