• 제목/요약/키워드: 공동 형상

Search Result 215, Processing Time 0.018 seconds

An Analysis on the Status of Barrier Free Design Certifications in Center for Elderly (경로당 건축물의 장애물 없는 생활환경 인증실태 분석)

  • Lee, Jeong-Soo;Oh, Young-Sook;Eun, Dong-Shin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.313-320
    • /
    • 2018
  • The purposes of this study were to verify the status of Barrier Free Design Certification in the center for the elderly. To achieve these purposes, the architectural characteristics of the center for elderly and the status of Barrier Free Design Certification was analyzed. The results of this study were as follows. (1) The functional composition of centers for the elderly are similar regardless of the location, but the area and shape of the plot are very different according to the location. (2) According to an analysis on the status of Barrier Free Design Certification in centers for elderly, the sanitation and intermediate facilities are necessarily considerable adjustment. (3) For the accessability and conveniences of Barrier Free Design Certification in a small building, such as centers for the elderly, they are necessary to simplify the self-assessment documents, minimize the period for judging, and reducing the fees for certification.

Fabrication and Constructability of a General-Purpose Manufactured Precast Concrete Double Wall (범용 생산설비를 활용한 PC 더블월 제작 및 시공성에 관한 연구)

  • Park, Soon-Jeon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.4
    • /
    • pp.465-476
    • /
    • 2023
  • This study introduces the development of a precast concrete double-wall, applicable to basement construction in apartment buildings. Unlike traditional precast concrete double walls, the developed double-wall doesn't require specialized manufacturing equipment such as a lathe. The constructability of these advanced technologies was validated through a full-scale mock-up test using the precast concrete double wall. The test specimens were constructed to represent a structural wall with a thickness of 250mm. It was observed that the quality of the in-situ concrete, filled between two single panels of 110mm thickness each, was excellent. The construction efficiency of the developed double-wall system for basement construction in an apartment building was also examined. Expert interviews about installation times of precast concrete elements were conducted to evaluate the speed of the basement floor's installation. The results showed that installation of precast concrete elements, including the proposed double walls, could be completed within 20 to 29 days for a basement in an apartment building. This indicates a three-fold increase in construction efficiency compared to traditional methods relying on in-situ casting.

Stress distribution of molars restored with minimal invasive and conventional technique: a 3-D finite element analysis (최소 침습적 충진 및 통상적 인레이 법으로 수복한 대구치의 응력 분포: 3-D 유한 요소 해석)

  • Yang, Sunmi;Kim, Seon-mi;Choi, Namki;Kim, Jae-hwan;Yang, Sung-Pyo;Yang, Hongso
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.297-305
    • /
    • 2018
  • Purpose: This study aimed to analyze stress distribution and maximum von Mises stress generated in intracoronal restorations and in tooth structures of mandibular molars with various types of cavity designs and materials. Materials and Methods: Three-dimensional solid models of mandible molar such as O inlay cavity with composite and gold (OR-C, OG-C), MO inlay cavity with composite and gold (MR-C, MG-C), and minimal invasive cavity on occlusal and proximal surfaces (OR-M, MR-M) were designed. To simulate masticatory force, static axial load with total force of 200 N was applied on the tooth at 10 occlusal contact points. A finite element analysis was performed to predict stress distribution generated by occlusal loading. Results: Restorations with minimal cavity design generated significantly lower values of von Mises stress (OR-M model: 26.8 MPa; MR-M model: 72.7 MPa) compared to those with conventional cavity design (341.9 MPa to 397.2 MPa). In tooth structure, magnitudes of maximum von Mises stresses were similar among models with conventional design (372.8 - 412.9 MPa) and models with minimal cavity design (361.1 - 384.4 MPa). Conclusion: Minimal invasive models generated smaller maximum von Mises stresses within restorations. Within the enamel, similar maximum von Mises stresses were observed for models with minimal cavity design and those with conventional design.

A Study of Establishing the Plan of Lodging for the Workers of Gaesung Industrial Complex (개성공단 근로자 기숙사 건립 계획 연구)

  • Choi, Sang-Hee;Kim, Doo-Hwan;Kim, Sang-Yeon;Choi, Eun-Hee
    • Land and Housing Review
    • /
    • v.6 no.2
    • /
    • pp.67-77
    • /
    • 2015
  • Now that it is the current situation that the smooth supply and demand are necessary for 2nd phase of beginning construction and stable development of Gaesung Industrial Complex, this study was willing to offer the planning criteria and model to establish the lodging for the workers in Gaesung Industrial Complex based on the agreement that both South and North Korea agreed in 2007. Regarding the plan, its standard and the alternative were reviewed considering welfare of workers, economic efficiency, technical validity, possibility of agreement and long-term development. The exclusive area per capita was calculated through Labor Standards Act of Korea and status survey of lodging for the workers provided to border line area between China and North Korea and the economic alternative based on one room for 6 persons with the public restroom was compared with that of development type based on one room for 4 persons with indoor restroom. Especially regarding the proposed site, the area with the optimized position was set by considering gradient, accessibility and convenience of development out of the area of Dongchang-ri where was agreed already and the priority of the proposed site that can keep the existing building site and provide was offered. The necessary period for whole construction was set as approximately 36 months. Regarding construction method, RC Rahmen method was selected as the optimized alternative considering the workmanship of manpower of North Korea and conditions of supply and demand of materials and cluster-type vehicle allocation plan based on 4~6 units considering the efficiency of supplying service facilities and convenient facilities along the simultaneous accommodation of 15,000 people was offered. It was analyzed that total business expenses of approximately 80~100 billion Korean Won would required though there were the difference for each alternative in the charged rental way that the development business owner develops by lending the inter-Korea Cooperation Fund and withdraws the rent by the benefit principle. The possibility of withdrawing the rent was analyzed assuming that the period of withdrawing the investment is 30 years. Especially for the operation management after moving, the establishment of the committee of operating the lodging for the workers of Gaesung Industrial Complex (tentative name) was offered with the dualized governance that the constructor takes charge of operational management, collecting fees and management of infrastructure and human resource management is delegated to North Korea.

A petrological study on the formation of geological heritage around Sangjogam County Park, Goseong, Gyeongsangnam-do (천연기념물 제411호 경남 고성 덕명리 공룡화석 산지 일원 병풍바위의 형성에 관한 암석학적 연구)

  • Kong, Dal-Yong;Cho, Hyeong-Seong;Kim, Jae-Hwan;Yu, Yeong-Wan;Jung, Seung-Ho;Kim, Tae-Hyeong;Kim, Jong-Sun;Jeong, Jong-Ok;Kim, Kun-Ki;Kwon, Chang-Woo;Son, Moon
    • Korean Journal of Heritage: History & Science
    • /
    • v.51 no.2
    • /
    • pp.78-91
    • /
    • 2018
  • Sangjogam, located in Goseong, Gyeongsangnam-do, was designated as Natural Monument #411, because of its diverse geological heritage, such as fossils, ripple marks, dykes, and columnar joints. In the area, Byeongpungbawi, with its beautiful columnar joints vertical to the bedding plane of the underlying sedimentary rocks and spectacular coastal view, was named after its overall shape reminiscent of a huge folding screen. The purpose of this study was to investigate the formation process of the columnar joints using the anisotropy of magnetic susceptibility (AMS) method. AMS measurements showed that the k1 and k3 values representative of directions of the long and short axes of a magnetic particle at each point strongly clustered, and the oblate magnetic foliation structure in Byeongpungbawi developed during sill-type intrusion rather than lava flow. In summary, Byeongpungbawi was produced by sill-type intrusion along the bedding plane of the underlying sedimentary layer, and the subsequent formation of columnar joints was accompanied by the cooling and contraction of intruding rhyolite magma. This study potentially provides a basic research tool in understanding the formation mechanism of columnar joints which are widely distributed in southern Korea.