• 제목/요약/키워드: 공동이용시설

Search Result 252, Processing Time 0.025 seconds

A Comparative Study on Heat Loss in Rock Cavern Type and Above-Ground Type Thermal Energy Storages (암반공동 열에너지저장과 지상식 열에너지저장의 열손실 비교 분석)

  • Park, Jung-Wook;Ryu, Dongwoo;Park, Dohyun;Choi, Byung-Hee;Synn, Joong-Ho;Sunwoo, Choon
    • Tunnel and Underground Space
    • /
    • v.23 no.5
    • /
    • pp.442-453
    • /
    • 2013
  • A large-scale high-temperature thermal energy storage(TES) was numerically modeled and the heat loss through storage tank walls was analyzed using a commercial code, FLAC3D. The operations of rock cavern type and above-ground type thermal energy storages with identical operating condition were simulated for a period of five consecutive years, in which it was assumed that the dominant heat transfer mechanism would be conduction in massive rock for the former and convection in the atmosphere for the latter. The variation of storage temperature resulting from periodic charging and discharging of thermal energy was considered in each simulation, and the effect of insulation thickness on the characteristics of heat loss was also examined. A comparison of the simulation results of different storage models presented that the heat loss rate of above-ground type TES was maintained constant over the operation period, while that of rock cavern type TES decreased rapidly in the early operation stage and tended to converge towards a certain value. The decrease in heat loss rate of rock cavern type TES can be attributed to the reduction in heat flux through storage tank walls followed by increase in surrounding rock mass temperature. The amount of cumulative heat loss from rock cavern type TES over a period of five-year operation was 72.7% of that from above-ground type TES. The heat loss rate of rock cavern type obtained in long-period operation showed less sensitive variations to insulation thickness than that of above-ground type TES.

전략적 제휴에 의한 협동연구개발

  • 박상덕
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.261
    • /
    • pp.16-19
    • /
    • 1998
  • 한국전력공사에서는 국내의 타 기관과 전략적 제휴를 통한 연구자원 공동 출자방식의 협동연구개발 체제를 구축하고 지난 ''98년 2월부터 본격적으로 시행하고 있다. 이 협동연구개발은 기존의 공동연구개발과는 차이가 있는데 공동연구개발의 경우, 연구예산은 공사에서 전약 부담하고 연구내용의 일정부분을 외부기관에 의뢰하는 기술의 단 방향 아웃소싱 개념이라면 협동연구개발은 공사와 협동연구기관이 공동출자 및 기술협력을 통해 공동의 목표를 실현하는 양방향 아웃소싱이라고 할 수 있다. 경쟁력이 있는 분야만을 선택하여 집중투자하고 그 외의 것은 외부로부터 지원을 받아 목적을 달성함으로써 조직과 시설을 슬림화하고 핵심역량을 더욱 강화하는 것이 국내외의 신경영 추세인데, 이러한 협동연구개발의 확대시행은 취약한 국내의 연구개발 여건을 감안할 때 많은 효과가 기대된다. 즉 국내의 전력기술 관련 산학연이 자체 핵심역량을 명확히 하여 자원을 집중하게 됨으로써 기관별 핵심분야의 국제경쟁력을 단시간에 키울 수 있게 될 것이고 이미 외부에서 이루어진 비핵심분야의 기술혁신 성과 및 전문적인 능력을 효과적으로 이용할 수 있게 될 것이다.

  • PDF

Establishment of Numerical Model for Groundwater Flow (Water Curtain) Analysis around Underground Caverns (지하공동 주변의 지하수 흐름(수막)해석을 위한 수치모형의 확립)

  • Jeong, Il-Mun;Jo, Won-Cheol;Bae, Deok-Hyo
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.1
    • /
    • pp.63-73
    • /
    • 1997
  • Finite element model is established for the simulation of groundwater flow due to water curtain around underground oil storage Choleski decomposition method. The symmetric global conductance matrix is solved by vector storage Choleski decomposition method. The model is verified through comparison with the results of electric analogy. For the application of this model to real site, the finite element meshes are constructed according to representative vertical cross and longitudinal sections. In cross-sectional analysis, potential and flow distributions are compared based on the cavern pressure and horizontal water curtain. For longitudinal section, effects between nearly located caverns with or without vertical water curtain are analyzed. These results prove that the established model can be used as a tool for flow analysis around underground caverns.

  • PDF

75년도 1과학기술자 1마을기술결연 활동-과학기술로 소득증대에 기여

  • Korean Federation of Science and Technology Societies
    • The Science & Technology
    • /
    • v.9 no.4 s.83
    • /
    • pp.57-60
    • /
    • 1976
  • 서 언 1.마을 현황 가.형태 나.가구 및 인구수 다.농경지 및 임야현황 라.공동이용시설 마.주요특산물 2.기술지도활동내용 가.지도내용 나.지도획수와 부락민참여상황 3.효 과 4.성공사례(제주중문리,경남신율리,전남야은리,경북미대동 경기영동리) 결 언

  • PDF

The Nature and Challenges of Childcare Policies for Working Mothers in Korea (취업여성을 위한 보육정책의 특성과 과제)

  • Yu, Bo-Gyeong
    • Korea journal of population studies
    • /
    • v.27 no.2
    • /
    • pp.91-120
    • /
    • 2004
  • 이 연구는 취업여성을 대상으로 추진되고 있는 한국 보육정책의 특성을 분석한다. 우선 취업여성을 대상으로 하는 기존 보육정책의 규정들은 무엇보다 성 평등의 관점에서 볼 때 불완전하다. 취업여성의 육아가 사회의 책임, 남녀공동의 책임이라는 인식에 못 미치고 있다. 둘째, 기존 보육정책은 일반적인 취업여성의 대리보육 지원을 표방하고 있지만 실제적으로 저소득층 영${\cdot}$유아, 영아보다는 유아에 대한 보육지원에 역점을 둠으로써 취업여성의 실제 보육수요를 충족하지 못한다. 셋째, 정부는 강제적 규정, 재정지원의 확대라는 조치들을 통해 취업여성의 보육을 지원하고 있으나 그 수준은 그렇게 강력하지 못하다. 넷째, 정책결과의 관점에서 볼 때, 그동안 보육시설은 상당한 정도로 증가하였으나 공공보육시설, 직장 보육시설의 비율은 매우 낮다. 육아휴직 정책 역시 전체적 이용률이 낮은 수준이며, 남성의 이용률은 특히 낮은 것으로 나타난다. 기업체 및 근로자의 보육실태에 대한 사례조사 결과에서도 취업여성의 육아부담은 여전히 매우 높으며, 특히 가족에 의한 대리보육 비율이 높은 것으로 나타난다. 이 연구의 정책적 함의는 보육정책이 취업여성의 육아부담을 경감하여 고용평등을 제고하고, 출산율 향상을 도모하는 방안과 연계되기 위해서는 정책의 보완이 요구된다는 것이다.

Monitoring Result of Rock Mass Behavior during Excavation of Deep Cavern (대심도 지하 공간 굴착시의 암반거동 - 일본 SUPER KAMIOKANDE의 사례 -)

  • Lee Hong-Gyu
    • Tunnel and Underground Space
    • /
    • v.16 no.1 s.60
    • /
    • pp.11-25
    • /
    • 2006
  • The world's largest nucleon decay experiment facility is constructed at a depth of approximately 1,000 meters, in the Kamio Mine, Japan. The excavated cavern is consisted of a cylinder of 42.4 m high and a semi elliptical dome of 15.2 m high, with a bottom diameter of 40 m. The total excavation volume is approximately $69,000\;m^3$. Because of the character as a large cavern excavation in deep underground, there is many unknown factors in rock mechanics. Based on the results of rock test and numerical analysis, the monitoring of rock mass behavior accompanying progress of construction was performed by various instruments installed in the rock mass surrounding the cavern. The monitoring data was used in the study of measures for cavern stability.

Hydrogeological Characteristics of Seawater Intrusion in the Coastal Area (임해지역 주변에서의 해수침투특성)

  • 김천수;김경수;배대석;송승호
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.4 no.2
    • /
    • pp.61-72
    • /
    • 1997
  • With increasing activities for groundwater withdrawal and for the construction of underground cavern in the coastal areas, the seaward flow of groundwater has been disturbed or even reversed, resulting in seawater intrusion in aquifers. This phenomenon would be attributed to the freshwater contamination and the corrosion of steel materials. The hydrogeological and geochemical investigations have performed to characterize the seawater intrusion into the underground caverns located in the coastal area. Assumimg the inland aquifer as unconfined one, we have found out that the theoretical interface of freshwater-seawater is far different from the pathways identified. In the study site, the main pathways of seawater intrusion into the underground cavern are characterized as the sub-horizontal fractures (zones). The seawater intrusion in granitic terrane would depend mainly on the characteristics of conductive fracture system developed along the coastal area.

  • PDF

확산능을 이용한 지하 LPG 저장기지의 W/C 효율성 진단

  • 한일영;정일문;유홍정
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.09a
    • /
    • pp.31-34
    • /
    • 2001
  • 지하 LPG 저장기지의 수벽시설이 저장공동 주변 암반에 미치는 영향을 진단하기 위해서 수벽시설의 주입압력을 강하시키면서 간극수압계와 관측공에서의 지하수두 변화를 모니터링하였다. 수벽시설의 관측지점에 대한 효율성은 수치해석으로부터 수벽시설과 관측지점간 매질의 확산능을 구함으로써 분석하였다. 확산능 산출결과를 검증하기 위해서 수벽시설의 압력강하에 따른 관측지점에서의 수두강하비와 수두강하율을 구하여 확산능 결과와 비교하였다. 비교결과, 확산능은 수두강하비, 수두강하율과 일관된 변화를 보여주었으며 확산능의 값이 클수록 수벽공의 압력변화에 따른 관측지점에서의 반응성이 양호함을 나타내었다

  • PDF

The research of Power Quality compensation equipment and installation for elevator equipment of the apartment house (공동주택 엘리베이터의 전원품질 보상 장비 및 설치에 관한 고찰)

  • Kim, Gi-Hyun;Bang, Sun-Bae;Bae, Suk-Myong;Lee, Hee-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.41-42
    • /
    • 2006
  • 엘리베이터는 국내의 빠른 성장과 함께 급속도로 보급되고 있는 수직 형 교통수단으로 국민 대다수가 이용하고 있다. 엘리베이터의 빠른 보급과 함께 여러 가지 원인에 의해 엘리베이터에 갇히는 사고로 인하여 승객의 불안감을 유발시킬 수 있는 부분이 많이 증가하고 있다. 따라서 본 논문에서는 공동주택 엘리베이터에서 이런 갇힘 및 오동작 등을 발생 시킬 수 있는 Surge, Sag, Interruption, Noise(Harmonic) 등의 유입에 대한 대책으로 엘리베이터 설비에 어떤 보상 및 대책 장비들이 설치되어 있고 그 사양 및 현장 설치 시설에 대해 조사 분석 하였다. 조사한 장소에서 대부분이 서지 보호 장치, 노이즈 필터, AC Reactor의 설비 설치가 미비하였다. 조사된 자료는 공동 주택 엘리베이터의 전기적 장해원인 분석 및 대책을 제시하는데 자료로 이용될 것이다.

  • PDF

A Research on Using Satisfaction and Situation Survey of Common Meal Facilities for Seniors in Rural Areas - Focusing on the Pilot Project of Common Facilities for Rural Seniors from 2014 to 2015- (농촌고령자 공동급식시설의 현황 및 이용 만족도 연구 - 2014~15년 농촌고령자 공동시설지원 시범사업을 중심으로 -)

  • Kim, Seung-Geun
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.18 no.4
    • /
    • pp.41-51
    • /
    • 2016
  • This The purpose of this study is to evaluate user satisfaction with village bathhouses, selected from a two-year pilot project of common facilities for senior in rural areas from 2014 to 2015. A survey was conducted using a questionnaire to evaluate user satisfaction, and 135 questionnaires were collected from 18 common meal facilities. User satisfaction was evaluated in five categories with a five-point scale: location and spatial composition; emotions and intimacy; safety; nutrition; and maintenance and management. The results are as follows. First, when overall user satisfaction was evaluated on a five-point scale, the average score stood at 4.24 out of five points and 90.03 out of 100 points. These findings suggest that users were generally satisfied with the common meal facilities. Among five categories, scores except safety stood at four points or higher, indicating higher user satisfaction. Second, communal meal in rural areas have been carried out already but the environment for communal meal like cooking equipment, wastewater disposal, and space have been poor. However, the environment is improved through this pilot project, which has a positive effect to user satisfaction. Third, space planning for barrier-free or sanitary in storage of food containers are not adequate, which is necessary to detailed planning and concrete guideline.