• Title/Summary/Keyword: 공기 투과도

Search Result 296, Processing Time 0.025 seconds

An Empirical Study of Soundproof wall with Reduced Wind Load (풍하중 저감형 방음판의 실증 연구)

  • Choi, Jin-Gyu;Lee, Chan-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.272-278
    • /
    • 2018
  • Traffic volume has been greatly increasing due to urban development and the improvement of living standards, and many complaints are being raised due to the increasing road noise. As a countermeasure against these problems, highly soundproof walls are installed on the sides of roads. However, the ability to bear wind loads is a major design requirement for soundproof walls, which contributes to the exponential increases in construction costs and restricts the height of the walls. The aim of this study is to improve the performance of soundproof walls and to dramatically reduce wind loads while maintaining excellent price competitiveness. Based on Helmholz's resonator theory, a new concept is proposed for a ventilation-type soundproofing plate that can pass through a fluid like air and reduce noise. A full-scale metal soundproofing plate was produced to satisfy the quality standards of highways by conducting a sound-pressure transmission-loss test, wind tunnel test, and material quality test. To verify the reliability, the wall was manufactured and installed, and the sound insulation effect was examined by measuring the noise over time. In the future, ventilated soundproof walls on roads could create a pleasant living environment due to the high noise-insulation effect.

Degradation Evaluation of PEM Water Electrolysis by Method of Degradation Analysis Used in PEMFC (고분자전해질 연료전지 열화 분석방법에 의한 PEM 수전해 열화 평가)

  • Oh, Sohyeong;Yang, Jinwon;Chu, Cheun-Ho;Na, Il-Chai;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.59 no.1
    • /
    • pp.1-5
    • /
    • 2021
  • The PEM(Proton Exchange Membrane)water electrolysis uses the same PEM electrolyte membrane as the PEM fuel cell and proceeds by the same reaction but the opposite direction. The PEM fuel cell has many methods of degradation analysis since many studies have been conducted on the degradation and durability of the membrane and catalyst. We examined whether PEM fuel cell durability evaluation method can be applied to PEM electrolytic durability evaluation. During the PEM electrolytic degradation process, LSV(Linear sweep voltammetry), CV(Cyclic voltammetry), Impedance, SEM(Scanning Electron Microscope) and FT-IR(Fourier Transform Infrared spectroscopy) were analyzed and compared under the same conditions as the PEM fuel cell. As the PEM fuel cell, hydrogen passing through the membrane was oxidized at the Pt/C electrode, and the hydrogen permeation current density was measured to analyze the degree of degradation of the PEM membrane. Electrode degradation could be analyzed by measuring the electrode active area (ECSA) by CV under hydrogen/nitrogen flowing conditions. While supplying hydrogen and air to the Pt/C electrode and the IrO2 electrode, the impedance of each electrode was measured to evaluate the durability of the electrode and membrane.

Effects of Modified Atmosphere Packaging on the Quality of Chitosan and $CaCl_2$ Coated Mushroom (Agaricus bisporus) (환경가스조절 포장이 키토산 및 $CaCl_2$로 코팅 처리된 양송이 버섯의 품질에 미치는 영향)

  • Lee, Jin-Sil
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.5
    • /
    • pp.1308-1314
    • /
    • 1999
  • The effects of modified atmosphere(MA) packaging and coating on the quality of mushroom (Agaricus bisporus) were investigated. Whole mushrooms(100 g) were packed with polyvinyl chloride(PVC) film wrap, PD941 and PD961 film bags and were stored in a chamber at $12^{\circ}C$ and 80% RH for 6 days. Gas composition of packages, respiration rate, weight loss, color and maturity index of MA packaged mushrooms were examined. The wrap packaged mushrooms showed different level of internal $CO_2$ concentrations among water washed, chitosan coated and $CaCl_2$ coated subgroups significantly at 5% level. The maximum $CO_2$ concentration of PD941 and PD961 packages for all coated showed $4.1{\sim}4.7%$ and $10.4{\sim}11.7%$, respectively, for the first day. PD961 package showed the lowest $O_2$ concentration compared to other groups. There were no significant respiration rate differences between wrap packed and PD941 packaged. Respiration rate of water washed. chitosan coated and $CaCl_2$ coated in PD961 packaged was 192 mg, 226 mg and 245 mg, respectively. Maturity index of PD961 packaged were not significantly different among the water washed, chitosan and $CaCl_2$ coated packages. Chitosan coating showed a negative effect on color change of mushrooms. The weight loss of 961 packaged was lower $(7.0{\sim}8.0%)$ that those of wrap packaged and PD941 packaged.

  • PDF

Analysis of Rainfall Infiltration Velocity in Unsaturated Soils Under Both Continuous and Repeated Rainfall Conditions by an Unsaturated Soil Column Test (불포화토 칼럼시험을 통한 연속강우와 반복강우의 강우침투속도 분석)

  • Park, Kyu-Bo;Chae, Byung-Gon;Park, Hyuck-Jin
    • The Journal of Engineering Geology
    • /
    • v.21 no.2
    • /
    • pp.133-145
    • /
    • 2011
  • Unsaturated soil column tests were performed for weathered gneiss soil and weathered granite soil to assess the relationship between infiltration velocity and rainfall condition for different rainfall durations and for multiple rainfall events separated by dry periods of various lengths (herein, 'rainfall break duration'). The volumetric water content was measured using TDR (Time Domain Reflectometry) sensors at regular time intervals. For the column tests, rainfall intensity was 20 mm/h and we varied the rainfall duration and rainfall break duration. The unit weight of weathered gneiss soil was designed 1.21 $g/cm^3$, which is lower than the in situ unit weight without overflow in the column. The in situ unit weight for weathered granite soil was designed 1.35 $g/cm^3$. The initial infiltration velocity of precipitation for the two weathered soils under total amount of rainfall as much as 200 mm conditions was $2.090{\times}10^{-3}$ to $2.854{\times}10^{-3}$ cm/s and $1.692{\times}10^{-3}$ to $2.012{\times}10^{-3}$ cm/s, respectively. These rates are higher than the repeated-infiltration velocities of precipitation under total amount of rainfall as much as 100 mm conditions ($1.309{\times}10^{-3}$ to $1.871{\times}10^{-3}$ cm/s and $1.175{\times}10^{-3}$ to $1.581{\times}10^{-3}$ cm/s, respectively), because the amount of precipitation under 200 mm conditions is more than that under 100 mm conditions. The repeated-infiltration velocities of weathered gneiss soil and weathered granite soil were $1.309{\times}10^{-3}$ to $2.854{\times}10^{-3}$ cm/s and $1.175{\times}10^{-3}$ to $2.012{\times}10^{-3}$ cm/s, respectively, being higher than the first-infiltration velocities ($1.307{\times}10^{-2}$ to $1.718{\times}10^{-2}$ cm/s and $1.789{\times}10^{-2}$ to $2.070{\times}10^{-2}$ cm/s, respectively). The results reflect the effect of reduced matric suction due to a reduction in the amount of air in the soil.

Inhibition of Viability and Genetic Change in Hypoxia-treated Lung Pericytes (허파혈관주위세포에서 저산소증에 의한 생존능의 억제와 유전자 발현의 변화)

  • Shin, Jong Wook;Kim, Kae-Young;Lee, Young Woo;Jung, Jae Woo;Lee, Byoung Jun;Kim, Jae-Yeol;Jo, Inho;Park, In Won;Choi, Byoung Whui
    • Tuberculosis and Respiratory Diseases
    • /
    • v.57 no.1
    • /
    • pp.37-46
    • /
    • 2004
  • Background : Lung pericytes are important constituent cells of blood-air barrier in pulmonary microvasculature. These cells take part in the control of vascular contractility and permeability. In this study, it was hypothesized that change of lung pericytes might be attributable to pathologic change in microvasculature in acute lung injury. The purpose of this study was how hypoxia change proliferation and genetic expression in lung pericytes. Methods : From the lungs of several Sprague-Dawley rats, performed the primary culture of lung pericytes and subculture. Characteristics of lung pericytes were confirmed with stellate shape in light microscopy and immunocytochemistry. 2% concentration of oxygen and $200{\mu}M$ $CoCl_2$ were treated to cells. Tryphan blue method and reverse transcription-polymerase chain reaction were done. Results : 1. We established methodology for primary culture of lung pericytes. 2. Hypoxia inhibited cellular proliferation in pericytes. 3. Hypoxia could markedly induce vascular endothelial growth factor(VEGF) and smad-2. 4. Hypoxia-inducible factor-$1{\alpha}$(HIF-$1{\alpha}$) was also induced by 2% oxygen. Conclusion : Viability of lung pericytes are inhibited by hypoxia. Hypoxia can stimulate expression of hypoxia-responsive genes. Pericytic change may be contributed to dysfunction of alveolar-capillary barrier in various pulmonary disorders.

Efficiency Evaluation of CT Simulator QA Phantom (전산화 단층촬영 모의치료기 정도관리 팬텀의 유용성 평가)

  • Hwang, Se-Ha;Min, Je-Sun;Lee, Jae-Hee;Park, Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.89-95
    • /
    • 2009
  • Purpose: The purpose is to evaluate efficiency of the CT simulator QA phantom manufactured for daily QA. Materials and Methods: We made holes ($1{\times}100{\times}1\;mm$) to verify accuracy between image and real measurement in polystyrene phantom and made 1 mm holes to verify table movement accuracy at superior and inferior 100 mm to the center of the phantom and inserted radiopacity material. To evaluate laser alignment, we made cross mark on the right and left side at phantom and to evaluate CT number accuracy we made 3 cylindrical holes and inserted equivalence material of bone, water, air in them. After CT scanning the phantom, We evaluated accuracy between image and real measurement, accuracy of table movement, laser, and CT number using exposed image. Results: It was measured that the accuracy between image and real measurement was ${\pm}0.3\;mm$, table movement accuracy was ${\pm}0.3\;mm$, laser accuracy was ${\pm}0.5\;mm$ from 7th January to 7th March in 2008 as within the reference point ${\pm}1\;mm$. In the CT number accuracy of bone was ${\pm}10\;HU$, air was ${\pm}5\;HU$, water was ${\pm}5\;HU$ as within the reference point is ${\pm}10\;HU$. Conclusion: We was able to perform CT simulator QA and laser equipment QA more conveniently and fast using manufactured phantom at the same time. We will be able to make more accurate treatment plan that added to QA procedures using images at previous daily QA.

  • PDF

Analysis of Radiation Treatment Planning by Dose Calculation and Optimization Algorithm (선량계산 및 최적화 알고리즘에 따른 치료계획의 영향 분석)

  • Kim, Dae-Sup;Yoon, In-Ha;Lee, Woo-Seok;Baek, Geum-Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.137-147
    • /
    • 2012
  • Purpose: Analyze the Effectiveness of Radiation Treatment Planning by dose calculation and optimization algorithm, apply consideration of actual treatment planning, and then suggest the best way to treatment planning protocol. Materials and Methods: The treatment planning system use Eclipse 10.0. (Varian, USA). PBC (Pencil Beam Convolution) and AAA (Anisotropic Analytical Algorithm) Apply to Dose calculation, DVO (Dose Volume Optimizer 10.0.28) used for optimized algorithm of Intensity Modulated Radiation Therapy (IMRT), PRO II (Progressive Resolution Optimizer V 8.9.17) and PRO III (Progressive Resolution Optimizer V 10.0.28) used for optimized algorithm of VAMT. A phantom for experiment virtually created at treatment planning system, $30{\times}30{\times}30$ cm sized, homogeneous density (HU: 0) and heterogeneous density that inserted air assumed material (HU: -1,000). Apply to clinical treatment planning on the basis of general treatment planning feature analyzed with Phantom planning. Results: In homogeneous density phantom, PBC and AAA show 65.2% PDD (6 MV, 10 cm) both, In heterogeneous density phantom, also show similar PDD value before meet with low density material, but they show different dose curve in air territory, PDD 10 cm showed 75%, 73% each after penetrate phantom. 3D treatment plan in same MU, AAA treatment planning shows low dose at Lung included area. 2D POP treatment plan with 15 MV of cervical vertebral region include trachea and lung area, Conformity Index (ICRU 62) is 0.95 in PBC calculation and 0.93 in AAA. DVO DVH and Dose calculation DVH are showed equal value in IMRT treatment plan. But AAA calculation shows lack of dose compared with DVO result which is satisfactory condition. Optimizing VMAT treatment plans using PRO II obtained results were satisfactory, but lower density area showed lack of dose in dose calculations. PRO III, but optimizing the dose calculation results were similar with optimized the same conditions once more. Conclusion: In this study, do not judge the rightness of the dose calculation algorithm. However, analyzing the characteristics of the dose distribution represented by each algorithm, especially, a method for the optimal treatment plan can be presented when make a treatment plan. by considering optimized algorithm factors of the IMRT or VMAT that needs to optimization make a treatment plan.

  • PDF

Microenvironments and Cellular Proliferation Affected by Oxygen Concentration in Non-Small Cell Lung Cancer Cell Line (비소세포폐암주에서 산소 농도에 따른 미세 배양 환경과 세포 증식능)

  • Shin, Jong Wook;Jeon, Eun Ju;Kwak, Hee Won;Song, Ju Han;Lee, Young Woo;Jeong, Jae Woo;Choi, Jae Cheol;Kim, Jae-Yeol;Park, In Won;Choi, Byoung Whui
    • Tuberculosis and Respiratory Diseases
    • /
    • v.63 no.3
    • /
    • pp.242-250
    • /
    • 2007
  • Background: Abnormal angiogenesis can induce hypoxia within a highly proliferating tumor mass, and these hypoxic conditions can in turn create clinical problems, such as resistance to chemotherapy. However, the mechanism by which hypoxia induces these changes has not yet been determined. Therefore, this study was conducted to determine how hypoxia induces changes in cell viability and extracellular microenvironments in an in vitro culture system using non-small cell lung cancer cells. Methods: The non-small cell lung cancer cell line, A549 was cultured in DMEM or RPMI-1640 media that contained fetal bovine serum. A decrease in the oxygen tension of the media that contained the culture was then induced in a hypoxia microchamber using a $CO_2-N_2$ gas mixture. A gas analysis and an MTT assay were then conducted. Results: (1) The decrease in oxygen tension was checked the anaerobic gas mixture for 30 min and then reoxygenation was induced by adding a 5% $CO_2-room$ air gas mixture to the chamber. (2) Purging with the anaerobic gas mixture was found to decrease the further oxygen tension of cell culture media. (3) The low oxygen tension resulted in a low pH, lactic acidosis and a decreased glucose concentration in the media. (4) The decrease in glucose concentration that was observed as a result of hypoxia was markedly different when different types of media were evaluated. (5) The decrease in oxygen tension inhibited proliferation of A549 cells. Conclusion: These data suggests that tumor hypoxia is associated with acidosis and hypoglycemia, which have been implicated in the development of resistance to chemotherapy and radiotherapy.

Analysis of the Insulation Effectiveness of the Thermal Insulator by the Installation Methods (보온단열재의 설치방법에 따른 보온성 효과 분석)

  • Kim, Young-Bok;Lee, Si-Young;Jeong, Byoung-Ryong
    • Journal of Bio-Environment Control
    • /
    • v.18 no.4
    • /
    • pp.332-340
    • /
    • 2009
  • In this study, the thermal insulation effectiveness of the greenhouse insulators by the installation methods was investigated to find the right installation way of the insulation materials. Physical properties of the insulators such as thickness, air transmissivity, apparent density, ultraviolet rays cutoff ratio, reflectance, thermal conductivity, moisture absorptivity were evaluated and the insulation ability of the insulators were measured by the module experiments. For the same insulator, the insulation ability of the case with the outward direction of the black colored face, i.e., with the inward direction of the white colored face, was better than that of vice versa. The case of the black colored both surfaces was better than the case of the white colored both surfaces. For aluminium reflection material, the case with the outward direction of the lustre face, i.e., with the inward direction of the non-lustre face, was better than that of vice versa. For the same material with the inner thin polyethylene foam (or polyester) and the chemical wool, the case with the outward direction of the inner thin polyethylene foam (or polyester), i.e., with the inward chemical wool, was better than that of vice versa. Addition of the inner thin polyethylene foam increased the insulation effect very much.

Hydrophilic Modification of Porous Polyvinylidene Fluoride Membrane by Pre-irradiating Electron Beam (전자빔 전조사를 이용한 Polyvinylidene Fluoride 다공막의 친수화 개질)

  • Choi, Yong-Jin;Lee, Sung-Won;Seo, Bong-Kuk;Kim, Min
    • Membrane Journal
    • /
    • v.21 no.2
    • /
    • pp.118-126
    • /
    • 2011
  • A method of light pre-irradiation, one of methods modifying hydrophobic surface to hydrophilic surface in a membrane, was proposed to overcome the drawback of previous methods such as blending, chemical treatment and post-irradiation, Process of membrane preparation in the study was comprised of 4 parts as follows: firstly process of precursor preparation to introduce hydrophilic nature under atmosphere and aqueous vapor by irradiating electron beam (EB), secondly process of dope solution preparation to cast on non-woven fabrics, thirdly process of casting to prepare membrane and finally process of coagulation in non-solvent to form porous structure. The merit of this method might show simple process as well as homogenous modification compared to previous methods. To carry it out, precursor was prepared by irradiating EB to powder PVDF at 75~125 K Gray dose. Precursor prepared was analyzed by FTIR, EDS and DSC to confirm the introduction of hydrophilic function and its mechanism. From their results, it was inferred I conformed that hydrophilic function was hydroxy1 and it was introduced by dehydrozenation. Hydrophilicity of membranes prepared was evaluated by contact angle (pristine PVDF : $62^{\circ}$, 125 K Gray-PVDF$13^{\circ}$). Porosity was evaluated by mercury intrusion method, simultaneously morpholoy and surface pore size were observed by SEM phothographs. The result showed the trend that more dose of EB led to smaller pore size and to lower porosity (pristine PVDF : 82%, 125 K Gray-PVDF : 63%). Trend of water permeability was similar to result above (pristine PVDF : 892 LMH, 125 K Gray-PVDF : 355 LMH).