Characteristics of NOx Emission in a Swirl Flow in Nonpremixed Turbulent Hydrogen Jet with Coaxial Air (수소 난류 확산화염에서의 선회류에 의한 배기배출물 특성)

  • Oh, Jeong-Seog;Yoon, Young-Bin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.3
    • /
    • pp.275-282
    • /
    • 2010
  • The effect of swirl flow on NOx in a nonpremixed turbulent hydrogen jet with coaxial air was studied. The swirl vane angle was varied from $30^{\circ}$ to $90^{\circ}$. The fuel jet air velocity and coaxial air velocity were varied in an attached flame region as $u_F=85{\sim}160m/s$ and $u_A=7{\sim}14m/s$. The objective of the current study was to analyze the characteristics of nitrous oxide emission in a swirl flow and to propose a new parameter for EINOx scaling. The experimental results show that EINOx decreases with the swirl vane angle and increased with flame length. Further, EINOx scaling factors can be determined by considering the effective diameter ($d_{F,eff}$) in a far field concept. The EINOx increased in proportion to the flame residence time (${\sim}{\tau_R}^{1/2.8}$) and the global strain rate (${\sim}{S_G}^{1/2.8}$).

A study on composition and role of SLA(Service Level Agreement) -based on Incheon Airport (서비스수준협약의 구성요소 및 역할에 관한 연구 -인천공항을 중심으로)

  • Ye, Jeong-Beom;Park, Gwang-Hui
    • 한국항공운항학회:학술대회논문집
    • /
    • 2016.05a
    • /
    • pp.281-286
    • /
    • 2016
  • 국 내외 기업들이 새로운 경영기법으로 도입하고 있는 아웃소싱은 비용절감, 핵심 업무에 대한 집중, 생산성 제고 등의 장점으로 빠르게 확산되고 있다. 인천국제공항 역시 공기업 경영혁신과 내부요인 등으로 인해에 개항과 함께 아웃소싱을 도입하였으며, 2014년 3월 현재에는 43개 분야에 아웃소싱을 도입하여 운영하고 있다. 이처럼 아웃소싱 도입이 확산 되면서 성공적인 아웃소싱 관리에 대해 모색하게 되었고, 인천국제공항 역시 효율적인 관리를 위해 주로 IT 분야에서 적용하고 있는 서비스수준협약(Sercive Level Agreement, SLA)을 전 분야에 걸쳐 도입하게 된다. 인천국제공항은 서비스수준협약을 통해 서비스 수준에 영향을 미치는 복합적인 요인을 효율적으로 관리하고 지속적인 서비스 품질수준을 유지하고자 도입한 것이다. 그러나 대부분의 서비스수준협약이 IT 분야에만 집중되어 있어 아직까지는 비(非) IT 분야의 서비스수준협약 시행은 초기 단계이며 서비스수준협약 측정지표 선정에 관한 연구는 매우 부족한 상태이다. 본 연구에서는 현재 인천공항에서 운영 중인 서비스수준협약을 유사용역 그룹별로 구분하여 구성요소와 역할에 대해 파악하고자 하였으며 서비스수준협약 측정지표가 공항운영 효율성에 어떠한 영향을 미치는지 확인하고자 하였다. 연구결과 서비스수준협약 측정지표의 명확성, 적정성, 업무 통제 가능성은 과업운영의 효율성에 유의미한 것으로 나타났으며, 현재 인천공항에서 운영 중인 서비스수준협약 평가 결과에 대한 인식이 과업 운영의 효율성에도 유의미한 것으로 나타났다. 또한 현행 서비스수준협약 평가 결과에 따라 과업의 문제점이 반영되는지 여부와 과업운영의 효율성 간의 상관관계 분석결과 통계적으로 유의한 것으로 분석되고 있다.

  • PDF

The behavior of air pollutant associated with atmospheric inversion in Ulsan (울산지역 역전층 형성과 관련한 오염물질의 거동)

  • 이영미;김유근;이화운;박종길;오인보;임윤규
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.339-340
    • /
    • 2003
  • 일반적으로 대기에 배출된 오염물질의 확산과 수송과정은 공기의 연직 열적 구조에 의해 좌우되기 때문에(Coulter, 1979; Dayan et al., 1988) 이를 예측하기 위해서는 역전층과 혼합층 고도가 필수적으로 고려되어야 한다(권병혁 등, 2001). 따라서, 연직관측을 통해 대기 경계층의 연직구조를 조사하는 것은 지역 대기오염관리에 있어 매우 중요하다고 볼 수 있다. 특히, 역전층 형성과 고도변화는 대기오염의 지표 고농도를 유발시키는 중요한 현상의 하나로서, 지표면 부근에 역전층이 존재할 경우, 대기의 확산운동이 억제되어 고농도 현상이 나타날 수 있다. (중략)

  • PDF

A Study on The Performance of Ventilation and Thermal Environment for a Combined Type Diffuser in a Residential Space (거주공간에 대한 급·배기 일체형 디퓨저의 환기 및 온열환경 유지성능에 대한 연구)

  • Lim, Seok-Young;Chang, Hyun-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.74-81
    • /
    • 2017
  • In this study, the combined-type diffuser developed by the Authors, in a previous study, was applied to a residential space. The performance of a ventilation and thermal environment, created by the use of a combined-type diffuser was compared to the pan-type diffuser widely used in apartment houses. In cooling conditions, because of the relatively high air flow rate of ceiling cassette-type air conditioners, the characteristics of airflow distribution in a room were governed by the air conditioner's airflow. In heating conditions, because of the low air flow rate of the diffuser, the characteristics of airflow distribution were governed by the buoyancy effect created by cold external walls and a hot floor. In terms of the Air Diffusion Performance Index (ADPI), which is a thermal environmental index, the result of a combined-type diffuser was greater than a pan-type diffuser in both of cooling and heating conditions. Consequently, the combined-type diffuser showed equal or superior ventilation and thermal environment performance compared to a pan-type diffuser.

A Field Measuring Study on the Thermal Environment of Human Surrounding in the Classroom Equipped with Ceiling Unit (천장형 유닛을 설치한 교실 내의 인체 주변 온열환경에 관한 실측연구)

  • Cho Sung-Woo;Im Young-Bin;Lee Kyung-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.3
    • /
    • pp.240-246
    • /
    • 2006
  • This paper performed to investigate on vertical temperature distribution, effective draft temperature (ETD) and PMV (Predicted Mean Vote) in the classroom, which is located YangSan city (Kyungsangnam-Do), Korea, is equipped with ceiling unit. The vertical temperature difference between F.L+10 cm (ankle) and F.L+120 cm (neck) of a measuring point which is adjacent corridor in the classroom showed about $1^{\circ}C$ but of measuring point which is adjacent outdoor expressed up to $4^{\circ}C$, The effective draft temperature (ETD) is -2.3 and -0.52 and 0.67 at near ceiling unit but is 1.2 and 3.3 at far from ceiling unit. The PMV of total classroom showed the range of 'Cold' and 'Slightly Cold.' Therefore, to achieve comfort condition in the classroom is equipped with ceiling unit, the location of ceiling unit and discharge angle and discharge distance from ceiling unit are very important elements.

Comparison of Indoor Thermal Environments in Winter depending on Supply Vent Configurations (급기구 형상에 따른 겨울철 실내 온열환경의 비교)

  • Han, Hwa-Taik;Jeong, Young-Kyun
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.970-975
    • /
    • 2008
  • This study considers indoor thermal comfort in an ondol space by supply vent configurations to prevent cold draft in winter. A specially-designed vent cap has been investigated in comparison with a round pan-type vent and a simple opening without a cap. Numerical simulations have been conducted using CFD to analyze thermal comfort indices such as Predicted Mean Vote (PMV) and Effective Draft Temperature (EDT) as well as air distribution index i.e. Air Diffusion Performance Index (ADPI). Results show the new vent cap provides improved thermal comfort conditions especially near ondol heated floor, as the cold outdoor air spreads upwards along the vertical wall before reaching occupant region near floor. This paper includes discussions on the flow and comfort distributions created by the thermal jets from the vents.

  • PDF

A Study on The Performance of Ventilation and Maintaining Thermal Environment for a Combined Type Diffuser (급·배기 일체형 디퓨저의 환기 및 온열환경 유지성능에 대한 연구)

  • Lim, Seok-Young;Chang, Hyun-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.232-241
    • /
    • 2016
  • Installing a ventilator for an apartment house composed of over 100 dwelling units was mandated in 2006 to improve indoor air quality. In the case of mechanical ventilators, the air change rate is kept stable, however 68% of dwellers do not operate their ventilator because of an increased electrical bill and noise. In the case of natural ventilators, the former problems are settled, but there are concerns about cold draught and an increase of heating/cooling cost. Authors are developing a heat recovery type natural ventilator which is a natural ventilator equipped with total heat recovery element, and it is expected that those problems of mechanical ventilator and natural ventilator are resolved by this. The combined type diffuser of this study is an under developed fit to the heat recovery type natural ventilator above. There are no standards to evaluate the performance for this type of diffuser. Due to this issue this study investigated the performance of the ventilation and maintained a thermal environment for the combined type diffuser by comparing it with existing diffusers. The results revealed that the performances of the combined type of diffusers showed different features from the existing ones, and was estimated to be high enough in the performances above.

A Study on the Ventilation Schemes for Gas Leakage and Dispersion Controlling at the Backfilled Working Face in Large-Opening Underground Mine (대단면 지하광산 갱도내 뒷채움 작업장 가스유출 및 확산제어 통기방안 연구)

  • Nguyen, Vanduc;Lee, Changwoo
    • Tunnel and Underground Space
    • /
    • v.28 no.4
    • /
    • pp.372-386
    • /
    • 2018
  • The air quality near the backfilled site area is significantly deteriorated during and even after the curing period of the backfill materials. Hazardous gases such as NH3 and CO2 may leak out prolongedly from the mined-out sites backfilled with the composite carbonate-based material; leakage can be observed at the underground working sites as well as on the surface. At operating mines, underground gas leakage will severely aggravate the workplace environment. The ventilation schemes should supply sufficient air to dilute the contaminated air, and control the toxic gas leakage and dispersion. This study shows the applicability of pressurization ventilation system to control gas leakage and dispersion at the backfilled underground mine site.

Evaluation of Ventilation Performance of a Residential Unit for Different Sampling Points through Actual Field Tests (실증실험을 통한 측정 위치에 따른 주거공간 환기성능 평가)

  • Kwag, Byung Chang;Lee, Soo Man;Kim, Gil Tae;Kim, Jong Yeob
    • Land and Housing Review
    • /
    • v.13 no.3
    • /
    • pp.93-106
    • /
    • 2022
  • Ventilation plays an important role in controlling indoor air quality. Due to the recent spread of infectious diseases such as COVID-19 and with people spending more time indoors, there's been increased attention on the importance of ventilation performance. In many countries, ventilation is regulated by airflow rates and the number of air changes per hour (ACH). However, airflow rates and ACH alone do not provide an accurate account of actual indoor pollutant removal and ventilation uniformity in a space. This study looked into the ventilation performance of an actual residential unit using several sampling points instead of basing it off of airflow and air change rates. Literature review was used to derive relevant influencing factors and the tracer gas dilution method was used for the field test. The study measured air velocity, age of air, and ventilation efficiency at several locations and compared them to the average value at the center of the test space to determine the differences in ventilation performance at the selected measurement points. The study showed that different sampling locations resulted in different ventilation values. Findings of this study will be used to develop an experimental procedure for evaluating indoor ventilation performance of actual residential spaces.

A Basic Study on Physical Method for Preventing Recombination of Gas Product from the Decomposition of Ammonium Carbamate (암모니움 카바메이트 분해 시 생성된 가스의 재결합 방지를 위한 물리적 방법의 기초연구)

  • Chun, Minwoo;Yoon, Cheon Seog;Kim, Hongsuk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.10
    • /
    • pp.639-647
    • /
    • 2017
  • This basic study is focused on the physically removal method of carbon dioxide from the decomposition of ammonium carbarmate to prevent the recombination of ammonium salts. A basic visual experimental set-up was designed and constructed to observe the recombination phenomena from the proper composition of ammonia gas, carbon dioxide gas, and compressed air dilution gas. To quantify the recombination phenomena, a simple device was designed to measure the weight change under severe cases for three different tube sizes. The temperature and pressure in the visual tube and the volumetric flow rates of the nitrogen dilution gas were studied and the conditions to avoid recombination were analyzed according to mean free path theory. Diffusivity values based on the Chapman-Enskog theory were calculated from the experimental data. These value may serve as an index for the prevention of recombination.