• Title/Summary/Keyword: 공기포집

Search Result 144, Processing Time 0.047 seconds

Nuclide Identification of Gamma Ray Energy Peaks from an Air Sample for the Emergency Radiation Monitoring (비상시 환경방사능 모니터링을 위한 공기부유진 시료의 감마선에너지 스펙트럼에 대한 핵종판별)

  • Byun, Jong-In;Yoon, Seok-Won;Choi, Hee-Yeoul;Yim, Seong-A;Lee, Dong-Myung;Yun, Ju-Yong
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.4
    • /
    • pp.170-175
    • /
    • 2009
  • For the emergency radiation monitoring using gamma spectrometry, we should sufficiently survey the background spectra as environmental samples with systematic nuclide identification method. In this study, we obtained the gamma ray energy spectrum using a HPGe gamma spectrometry system from an air sample. And we identified nuclide of the gamma ray energy peaks in the spectrum using two methods -1) Half life calculation and 2) survey for cascade coincidence summing peaks using nuclear data. As the results, we produced the nuclide identification results for the air sample.

A Study of Fine Dust Blocking Network Using Electrospinning Nanofiber Deposition (전기방사를 활용한 나노섬유 증착 미세먼지 방진망에 관한 연구)

  • Chan Young Lee;Sang Min Lee;Hyeon Jin Song;Jae Jun Lee;Young Soon Kim;Hong Gun Kim
    • Journal of The Korean Institute of Defense Technology
    • /
    • v.6 no.1
    • /
    • pp.13-18
    • /
    • 2024
  • While fine dust is currently spreading around the world, fine dust is so small that it easily enters indoors and deteriorates indoor air quality, so it is an essential issue that must be solved to maintain cleanliness and improve air quality in households. Research on nanoradiation technology is continuously being conducted to effectively block fine dust and secure air permeability and dust collection rate. In this study, a PVDF fine dust dust-proof net was manufactured through electrospinning, and an experiment was conducted to confirm the external environmental resistance and indoor air quality improvement efficiency of the manufactured dust-proof net. It was verified that this dustproof net can be a practical alternative to effectively block fine dust and prevent diseases caused by fine dust.

  • PDF

Evaluation for Application of IOM Sampler for Agricultural Farmer's Inhalation Exposure to Kresoxim-methyl and Fenthion (농작업자의 Kresoxim-methyl과 fenthion에 대한 호흡노출량 측정을 위한 IOM 채집기의 효율성 평가)

  • Lee, Jiho;Kim, Eunhye;Lee, Jonghwa;Shin, Yongho;Maasfeld, Wolfgang;Choi, Hoon;Moon, Joon-Kwan;Lee, Hyeri;Kim, Jeong-Han
    • The Korean Journal of Pesticide Science
    • /
    • v.19 no.3
    • /
    • pp.230-240
    • /
    • 2015
  • An IOM sampler equipped with glass fiber filter has been recently utilized instead of solid adsorbent, which was used to measure the inhalation exposure of agricultural operator to pesticides. The aim of this study is to validate the efficacy of an IOM sampler by measuring the trapping efficiency and breakthrough using kresoxim-methyl water-dispersible granule and fenthion emulsifiable concentrate. On LC-MS/ MS, minimum detection level was 12.5 pg and method limit of detection was 5.0 ng/mL. Good linearity ($R^2$ > 0.999) for matrix matched standards was obtained. Recoveries of pesticides from glass fiber filter were 102-109% (kresoxim-methyl) and 97-104% (fenthion) while those from XAD-2 resin were 94-98% (kresoxim methyl) and 93-100% (fenthion). Trapping efficiency test was performed with personal air pumps and IOM sampler (glass fiber filter) connected with solid adsorbent (XAD-2 resin) with two types of formulation (solid and liquid) which were diluted by standard rate and sprayed to IOM sampler. Those pesticides were trapped only in glass fiber filter without any breakthrough to solid adsorbent. After spiking of pesticides to glass fiber filter, breakthrough test was carried out with IOM sampler (glass fiber filter) which was connected with solid adsorbent. As a results, 87-101% of kresoxim-methyl and 96-105% of fenthion remained in spiked glass fiber filter, however, no pesticides were detected in second glass fiber filter and solid adsorbent. In conclusion, IOM sampler which equipped with glass fiber filter can be applied widely for pesticide inhalation exposure study since it has good trapping efficiency and adsorption capacity, regardless of the solid or liquid formulation.

Experimental Study on the Argon Impurity Effect in the Pressure Drop of CO2 mixture flow (관내 이산화탄소 압력강하에 아르곤 불순물이 미치는 영향에 관한 실험적 연구)

  • Cho, Meang-Ik;Kang, Seong-Gil;Huh, Cheol;Baek, Jong-Hwa
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8870-8878
    • /
    • 2015
  • During the carbon-dioxide capture and storage(CCS) process, $CO_2$ is captured from large point source, and then injected and stored in stable geological structure for thousands and more years. Inside the captured $CO_2$ flow, various impurities, such as $N_2$, $O_2$, argon, etc, are included inevitably. These impurities affect on the CCS process on various aspects. In this study, we designed and built experimental facility to evaluate the various impurity effect on the $CO_2$ pipeline flow, and analyzed the effect of argon ratio and pressure variation on the pressure drop of $CO_2$ flow. By comparing experimental data with 4 kinds of pressure drop model, we figured out and recommended the Cicchitti's model since it showed most accurate result among compared models in this study.

Classification and Condensation of Nano-sized Airborne Particles by Electrically Tuning Collection Size (포집크기의 전기적 튜닝 기술을 이용한 나노크기의 공기중 입자 분류 및 수농도 응축)

  • Kim, Yong-Ho;Kwon, Soon-Myoung;Park, Dong-Ho;Hwang, Jung-Ho;Kim, Yong-Jun
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1874-1879
    • /
    • 2008
  • It is not easy to detect nano-sized airborne particles (< 100 nm in diameter) in air. Therefore, the condensation of the nanoparticles alongside of the size-classification is needed for their detection. This paper proposes a hybrid (aerodynamic+electrical) particle classification and condensation device using a micro virtual impactor (${\mu}VI$). The ${\mu}VI$ can classify the nanoparticles according to their size and condense the number concentration of nanoparticles interested. Firstly, the classification efficiency of the ${\mu}VI$ was measured for the particles, polystyrene latex (PSL), ranging from 80 to 250 nm in diameter. Secondly, the nanoparticles, NaCl of 50 nm in diameter, were condensed by 4 times higher. In consequence, the output signal was amplified by 4 times (before condensation: 4 fA, after condensation: 16 fA). It is expected that the proposed device will facilitate the detection of nanoparticles.

  • PDF

Unrecorded Fungal Species Isolated from Indoor Air in the Log Bed- and Sawdust Media-based Mushroom Cultivation Houses (원목 및 톱밥배지 버섯 재배사 내 실내 공기서 분리한 미기록 진균 보고)

  • Ahn, Geum Ran;Kim, Ji Eun;Kim, Jun Young;Kim, Seong Hwan
    • The Korean Journal of Mycology
    • /
    • v.46 no.4
    • /
    • pp.495-503
    • /
    • 2018
  • Oak mushroom is cultivated using logs and sawdust media as substrates. In this study, fungi were isolated during a monitoring of indoor air in the oak mushroom cultivation houses located in Cheongyang-gun of Chungnam, Geoje-gun of Gyeongnam, Gumi-si of Gyeongbuk, Jangheung-gun of Jeonnam and Yeoju-si of Gyeongggi-do. Identification of the fungi based on morphology and molecular analysis of the internal transcribed spacer region and 28S rDNA, translation elongation factor translation elongation factor 1 a gene, and ${\beta}-tubulin$ gene revealed that six fungi, Cenangium acuum, Neopestalotiopsis surinamensis, Metarhizium marquandii, Periconia macrospinosa, Trichoderma petersenii, and Trichoderma paratroviride that have not been recorded previously in Korea.

Changes of Microorganisms During Fresh-Cut Cabbage Processing: Focusing on the Changes of Air-Borne Microorganisms (신선편이 양배추 제조공정 단계별 미생물 변화: 공기 중 미생물 변화를 중심으로)

  • Seo, Jung-Eun;Lee, Jong-Kung;Oh, Se-Wook;Koo, Min-Seon;Kim, Young-Ho;Kim, Yun-Ji
    • Journal of Food Hygiene and Safety
    • /
    • v.22 no.4
    • /
    • pp.288-293
    • /
    • 2007
  • To evaluate effects of airborne microorganisms in fresh cut processing plant, microorganisms in air, equipments, raw material, water and final product were isolated and identified using Vitek (R)2 compact system. Airborne microorganisms were isolated from 1000L air using air sampler for floating microorganisms and plate count agar for falling microorganisms. And contaminated microorganisms of equipment, water, and product were isolated from plate count agar plate. Total plate counts for floating and falling, raw material, equipments and final product were $10^2-10^3CFU/m^3,{\sim}10^1CFU/plate,\;10^3CFU/g,{\sim}10^4CFU/cm^2\;and\;10^4CFU/g$, respectively. From the result of isolated microorganism identification from raw material to final product, airborne microorganisms could affect the flora of final product.

Effect of aeration on the physicochemical characteristics of livestock feces compost during composting period (퇴비화과정 중 공기공급 여부가 가축분뇨 퇴비의 물리화학적 특성에 미치는 영향)

  • Jeong, Kwang-Hwa;Kang, Ho;Kim, Tai-ll;Park, Chi-Ho;Yang, Chang-Buem
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.11 no.4
    • /
    • pp.57-65
    • /
    • 2003
  • Livestock farming is one of several industries that have faced criticism because of its impact on the water quality, soil contamination and air pollution. The livestock feces can cause some environmental problems. The best way to treat the feces is to recycle the manure as an organic fertilizer after fermentation or composting. This study was carried out to investigate the characteristics of composting of manure in several composting conditions. The variations of physicochemical characteristics of each compost piles containing different level of air volume were analyzed throughout the composting period. In this study, pigs manure compost piles mixed with saw dust were composted in 110L of laboratory scale plastic vessels and $1.5m^3$ of small cubic wooden composting vessels for 60days. The compost piles were ventilated continuously with air pump throughout the composting duration. The air volume ventilated into the piles was regulated by chock valve attached to the inlet pipe. The ventilation level was adjusted by 20, 50, 100, 150 and $200L/m^3/mim$, respectively. The highest temperature of the compost increased to $72^{\circ}C$ during composting period. After 20days from beginning of fermentation, concentrations of $H_2S$, $CH_3SH$, DMS and DMDS generated from compost piles were 29, 16, 6 and 5ppb in blow in state compost pile, conversely, in blow out state compost pile, the parameters were 32, 24, 15 and 14ppb, respectively.

  • PDF

A Study on Effect of Recirculated Exhaust Gas upon Performance and Exhaust Emissions in a Power Plant Boiler with FGR System (FGR 시스템 동력 플랜트 보일러의 성능 및 배기 배출물에 미치는 재순환 배기의 영향에 관한 연구)

  • Bae, Myung-whan;Jung, Kwong-ho;Park, Sung-bum
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.4
    • /
    • pp.263-273
    • /
    • 2016
  • The effect of recirculated exhaust gas on performance and exhaust emissions with FGR rate are investigated by using a natural circulation, pressurized draft and water tube boiler with FGR system operating at several boiler loads and over fire air damper openings. The purpose of this study is to apply the FGR system to a power plant boiler for reducing $NO_x$ emissions. To activate the combustion, the OFA with 0 to 20% is supplied into the flame. When the suction damper of two stage combustion system installed in the upper side of wind box is opened by handling the lever between $0^{\circ}$ and $90^{\circ}$, also, the combustion air supplied to burner is changed. It is found that the fuel consumption rate per evaporation rate did not show an obvious tendency to increase or decrease with rising the FGR rate, and $NO_x$ emissions at the same OFA damper opening are decreased, as FGR rates are elevated and boiler loads are dropped. While a trace amount of soot is emitted without regard to the operation conditions of boiler load, OFA damper opening and FGR rate, because soot emissions are eliminated by the electrostatic precipitator with a collecting efficiency of 86.7%.

Reduction Effect of Various Air Purifiers on Airborne Microorganism for Preventing Air Infected Animal Disease (공기감염성 가축질병 예방을 위한 공기청정기 유형에 따른 부유 미생물의 제거 효과)

  • Park, Chan-Jeong;Kim, Hyeon-Tae;Kim, Ki-Youn
    • Journal of agriculture & life science
    • /
    • v.45 no.3
    • /
    • pp.89-96
    • /
    • 2011
  • The objective of this study is to evaluate reduction efficiency of various air purifiers on airborne microorganism causing air infected animal disease according to sample collection method. Collection efficiencies of MS2 virus and Pseudomonas fluorescens by biosampler was significantly higher than those by button sampler (p<0.05). Regardless of types of air purifier and sample collection method, temporal reduction efficiencies of MS2 virus and P. fluorescens compared to initial background concentration were >50% and >45% on 5 minutes, >70% and >50% on 15 minutes, >80% and >70% on 30 minutes and >90% and >75% on 60 minutes after operating air purifier, respectively. The air purifier of ionizer type showed the highest reduction efficiency on MS2 virus followed by air purifier of electronic precipitation, water filter and dry filter while the reduction efficiency of air purifier on P. fluorescens was highest in the electronic precipitation type followed by ionizer type, dry filter type and water filter type (p<0.05). Based on the results obtained from this study, temporal reduction efficiency of air purifier on MS2 virus was relatively higher than P. fluorescens.