원자력발전소 주제어실 공기조화계통 기능적설비그룹 개발 (FEG Development of MCR HVAC System for NPP)

  • 현진우
    • 한국압력기기공학회 논문집
    • /
    • 제8권2호
    • /
    • pp.21-25
    • /
    • 2012
  • Functional Equipment Group(FEG) of Nuclear Power Plant(NPP) is the bundling of multiple equipment subcomponents around a major equipment with a common system isolation characteristic or out-of-service consideration. The main purpose of FEG is to reduce out-of-service time to enhance maintenance effectiveness. KHNP(Korea hydro & Nuclear Power Co.) needs to develop these FEGs to successfully perform On-line Maintenance(OLM) which will be expected to institute in the future. Recently, there has been growing interest in OLM in KHNP. The aim of this paper is to suggest the way of FEG development and to build the FEG of MCR(Main Control Room) HVAC(Heat, Ventilation and Air Conditioning) system. The results of this study might be make good use of OLM and be helpful for equipment maintenance for MCR HVAC system.

에너지 및 동력공학부문

  • 지평삼
    • 기계저널
    • /
    • 제43권8호
    • /
    • pp.100-113
    • /
    • 2003
  • 2002년도 에너지 및 동력공각 분야의 주요 연구동향을 요약하여 소개한다. 내연기관, 가스터빈 및 증기터빈, 열병합 및 복합발전, 보일러 및 발전설비, 소각로, 연소기기, 원자력 에너지, 공기조화 등 각 세부분야에 있어서 심도 있는 연구 및 기술 개발이 폭넓게 이루어졌으며, 각 세부분야별 연구 동향을 소개하면 다음과 같다.

  • PDF

전열교환기 성능향상 및 로터 국산화 개발에 관한 연구 (A study on Rotor Development for Air-to-Air Heat Exchanger)

  • 서석정;박반욱
    • 한국기계연구소 소보
    • /
    • 통권16호
    • /
    • pp.17-28
    • /
    • 1986
  • 전열교환기는 최근 대형건물 및 생산공장 등의 에너지 다소비 장소의 공기조화설비의 에너지 절감기기로서 크게 각광 받고 있다. 그 중에서도 특히 알루미늄 박판에 실리카-겔 분말을 코팅한 Honey comb형 로터는 현열 및 잠열 즉 전열을 흡수할 수 있어 폐에너지 회수용 전열교환기의 전열소자로서 점차 이용되고 있다. 그러나 국내에서는 현재까지 전열교환기의 핵심부품인 상기 로터를 전량 수입에 의존하여 왔다. 본 연구에서는 백륜공업(주)와 공동출연으로 실리카-겔 분말 코팅된 알루미늄 소재 박판만 수입하여 성형공정 기술을 개선, 향상시켜 국산로터의 시제품을 제작하고 그 성능을 시험하여 수입로터와 비교, 평가하였다. 연구결과, 국산개발 알루미늄 로터 시제품의 전열효율이 수입로터 보다 급배기 조건에 따라 1~5%정도 향상되었다. 또한 알루미늄 로터의 최적운전조건(11-13 r.p.m) 및 급배기 공기량비에 대한 적정조건도 연구결과로 얻어졌다.

  • PDF

팬 및 펌프 모터의 이상유무 감시 -기술 및 제품-

  • 조추영
    • 대한설비공학회지:설비저널
    • /
    • 제31권5호
    • /
    • pp.42-47
    • /
    • 2002
  • 건물의 고도화 및 최첨단 공조시스템에 있어서 공기 조화기는 가장 핵심적인 장비로서 고장의 전도는 비교적 단순하나 요소기술의 적용, 운전, 유지관리에서 소홀하게 되 면 환경 업무의 저하와 생산성이 낮아지고 막대한 비용을 초래하기도 한다 . 고장은 설비시스템과 공조기의 사용기간이 길어짐에 따라 마모, 피로 등의 물리적 성능열화가 진행되며 이러한 물리적 열화가 최종적으로 나타나는 현상이 고장이다. 고장의 시간적 변화에는 초기고장, 우발고장, 마모고장으로 분류되며 초기고장은 시스템의 불안정에 따른 원인으로 시운전시에 자주 발생하고 정상적인 운전시에 발생되는 우발고장이 기간이 지나면 마모 고장기에 도달하게되며 이때는 부품의 한계수명과 마모등의 원인으로 고장률이 급격히 증가된다 따라서 본문에서는 공조시스템의 공기조차기의 팬과 펌프 기기의 고장원인을 살펴보고 이에 대한 고장을 신속하게 감시할 수 있는 방안을 일반적일 고찰을 통해 체계적이고 종합적인 대응방안을 소개하여 불필요한 보수비용의 발생과 생산성 저하를 방지하고 내구년수를 증가할 수 있는 신기술의 일부분을 소개하고자 한다.

  • PDF

전열교환기 성능향상 및 로타 국산화 개발에 관한 연구 (A Study on Rotor Development for Air-to-Air Heat Exchanger)

  • 서석청;박반욱
    • 대한설비공학회지:설비저널
    • /
    • 제15권3호
    • /
    • pp.226-233
    • /
    • 1986
  • 전열교환기는 최근 대형건물 및 생산공장 등의 에너지 다소비 장소의 공기조화 설비의 에너지 절감 기기로서 크게 각광 받고 있다. 그 중에서도 특히 알루미늄 박판에 실리카-겔 분말을 코팅한 허니컴형 로타는 현열 및 잠열 즉 전열을 흡수할 수 있어 폐 에너지 회수용 전열교환기의 전열소자로서 점차 이용되고 있다. 그러나 국내에서는 현재까지 전열교환기의 핵심부품인 상기 로타를 전량 수입에 의존하여 왔다. 본 연구에서는 백륜공업(주)와 공동출연으로 실리카-겔 분말 코팅된 알루미늄 소재 박판만 수입하여 성형공정 기술을 개선, 향상시켜 국산로타의 시제품을 제작하고 그 성능을 시험하여 수입로타와 비교, 평가하였다. 연구결과 국산개발 알루미늄 로타 시제품의 전열효율이 수입로타보다 급배기 조건에 따라 $1\~5\%$정도 향상되었다. 또한 알루미늄 로타의 최적운전조건$(11\~13\;r.p.m)$ 및 급배기 공기량비에 대한 적정조건도 연구결과로 얻어졌다.

  • PDF

공기조화용 액적방열기의 열전달특성에 관한 연구 (A Study on the Heat Transfer Characteristics of Liquid Droplet Radiator for Air Conditioning)

  • 김금무;김춘식;김용모;김종헌
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제19권4호
    • /
    • pp.17-26
    • /
    • 1995
  • In general existing air conditioning devices, which are carried out by convection heat transfer, are very popular compared with the radiation type air conditioning devices. But perconal convection tpe air conditioning units are unuseful air conditioning type because it handles amount of surrounded air to meet the temperature and humidity. In this view, this study is intended to develope personal dir conditioning units using a radiation type radiator. Liquid Droplet Radiator(L.P.R.) radiates the energy by means of thermal radiation. Radiative energy from L.P.R. is the infrared rays which heat the objects without lose of energy. It is a desirable heating method for the local area within the large room. In this study, the analysis uses the Monte Carlo methd to predict the temperature distribution in the droplet sheet and the net heat flux from the L.D.R.. And for this study and experiment was carried out to analyse the radiative and convective heat transfer characteristics in the L.D.R.. And the experiment was investigated the effects of inlet temperature, feed rate, optical thickness and droplet diameter on heat transfer characteristics of L.D.R.. The obtained results from the numerical and experimental studies of L.D.R. were as follows ; (1) The heat flux of L.D.R. was effected by extinction coefficient of droplet sheet, optical thickness and droplet temperature, surface area and emissivity of the droplet. And it was increased with the temperature, feed rate and optical thickness, on the other hand decreased with increasing of droplet diameter. (2) The experimental results for heat flux was ecalucted below 20% than that of the numerical solution by Monte Carlo method, but the tendency of the variation shows relatively good agreement.

  • PDF

원전의 공기조화설비(HVAC) 상실사고 분석방법 (Analysis of Loss of HVAC for Nuclear Power Plant)

  • 송동수
    • 에너지공학
    • /
    • 제23권1호
    • /
    • pp.90-94
    • /
    • 2014
  • 본 논문은 원자력발전소의 내환경기기검증(EQ)을 위한 HVAC 과도분석 방법에 대한 내용을 기술하고 있다. 분석 대상 격실은 비안전관련 HVAC 계통에 의해 공급되는 격실 중에 원자로 안전정지를 담당하는 중요기기가 위치한 구역/격실을 선정하였다. 그리고 해당 HVAC 계통이 공급되는 건물별로 HVAC 과도시 온도조건을 분석하였다. 본 분석을 위해서 GOTHIC 전산코드를 사용하였다. 온도분석 결과는 원자로 보조건물 환기계통(DVN)의 W315/W415 격실에서 $82.2^{\circ}C$로 가장 높은 온도값을 나타내며, 제어봉구동장치 전원공급건물 및 보조급수펌프실(DVG) 계통의 W229 (Auxiliary feedwater pump room) 격실에서 $52.7^{\circ}C$, 기기냉각건물 환기계통(DVI)의 전 격실에서 $42.9^{\circ}C$, 전기건물 주환기 계통(DVL)의 L207 (Hot workshop) 격실에서 $57.3^{\circ}C$를 각각 나타났다. 이러한 온도값은 일반적인 원전의 기기검증 제한값인 $171^{\circ}C$이하이므로 내환경검증 요건을 만족하는 온도이다.

벽걸이 형식을 도입한 공기청정기 디자인 개발 (Design Development of wall mount type air purifier)

  • 한일우
    • 디자인학연구
    • /
    • 제18권3호
    • /
    • pp.219-222
    • /
    • 2005
  • 본 작품은 쾌적하고 청결한 주거환경을 유지하기 위해 사용되는 공기청정기 제품에 있어서 벽면을 이용한 기기 운용방식에 관한 디자인 개발 연구이다. 최근 들어 생활수준이 향상됨에 따라 건강에 대한 관심이 증대되고 인간의 건강과 직결되는 실내에서의 공기청정에 대한 관심이 높아지면서 공기청정기의 사용과 그 수요가 크게 증가하고 있으며 이에 따라 공기청정기 시장도 확대되며 다양한 디자인의 제품들이 등장하고 있다. 그러나 현재 시장에 나와 있는 대부분의 제품들은 스탠드 방식으로서, 설치를 위해서는 적지 않은 공간이 필요하며 구조상 공기의 흡 배기를 위해 설치장소의 선정에 많은 제약이 따른다. 따라서 본 연구는 이미 에어컨 제품에서 널리 사용되고 있는 벽걸이 방식의 디자인 컨셉을 도입하여 설치장소의 제약 최소화와 함께 벽면장식의 효과도 가져을 수 있는 방식의 디자인을 시도하였다. 이 과정에서 사용자 편의를 위해 필터의 교환과 청소를 용이하게 하였고 다양한 기능을 간단하게 조작할 수 있도록 하였으며, 실내 어느 장소에나 잘 어울릴 수 있도록 전체적으로 슬림하면서도 미려하고 자연스러운 곡선이 직사각과 조화를 이루도록 디자인하였다.

  • PDF

사무소건물의 용도 및 측정기간에 따른 에너지 소비 특성 (Characteristics of Energy Consumption in an Office Building located in Seoul)

  • 박병윤;정광섭
    • 설비공학논문집
    • /
    • 제17권1호
    • /
    • pp.82-87
    • /
    • 2005
  • The purpose of this study is to suggest the characteristics and actual state of energy consumption by the analysis of energy consumption data in an office building. This study examines and analyzes daily and monthly energy consumption of an office building located in Seoul, Korea regarding type of load and business classification within a building. The results are as follows. 1) Energy consumption of office building for each type of load show similar consumption patterns, regardless of seasons such as cooling period and heating period. 2) Out of all annual energy consumption, consumption for lighting took about $43\;\%,$ general electric Power about $23\;\%,$ emergency power $25\;\%,$ computer center $5\;\%$ and cooling power $4\;\%,$ showing that the consumption for lighting was highest, and the percentage of energy consumption for cooling power for operation of cooling facilities took the lowest percentage. 3) Annual gas consumption used for heating and hot water supply were $38,\;36\;\%$ for officetel and office respectively, and $26\;\%$ for arcade. 4) Electricity consumptions used for cooling power for each use of building, office and officetel recorded in July and August of cooling seasons. Even though it shows different patterns for each month, energy consumption showed unique pattern throughout the cooling seasons.

복합형 태양열 가열기에서 열매체 단일운전에 따른 기기성능 평가 (Performance Estimation of Hybrid Solar Air-Water Heater on Single Working of Heating Medium)

  • 최휘웅;윤정인;손창효;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제34권6호
    • /
    • pp.49-56
    • /
    • 2014
  • Research about hybrid solar air-water heater that can make heated air and hot water was conducted as a part of improving efficiency of solar thermal energy. At this experiment, ability of making heating air and hot water was investigated and compared with traditional solar air heater and flat plate solar collector for hot water when air or liquid was heated respectively. Comparing hybrid solar air-water heater that used in this experiment to other solar air heater studied already, it has a lower efficiency at same mass flow rate. Air channel structure, fin's shape and arrangement in the air channel result in these difference then the ability of air heating need to be improved with changing these thing. In case of making hot water, performance was shown as similar with traditional system although the air channels were established beneath absorbing plate. But the heat loss coefficient was shown higher value by installing of air channel. Also the performance of hot water making was shown lower value at same liquid mass flow rate with traditional flat plate solar collector for hot water. So the necessity of performance improvement at lower mass flow rate of each heating medium can be confirmed.