• Title/Summary/Keyword: 공기정화시스템

Search Result 70, Processing Time 0.024 seconds

A Study on the Air Ventilation System of Operation Room for the Prevention of Hospital Infection (수술중 감염방지를 위한 공조시스템의 개선방안에 대한 연구)

  • Kim Chun-Sook;Kwon Soonjung;Joo Youngcheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.6
    • /
    • pp.552-557
    • /
    • 2004
  • The air ventilation system of operation rooms has been studied for the prevention of cross infection during the operation. Operation rooms and air ventilation systems of three University hospitals are investigated. The distribution of microbe is measured by cultivating air samples in the operation room. A two-dimensional model for the cross-section of an operation room is developed for the CFD analysis. The characteristics of air flow in operation room are calculated by using a CFD program. The current air ventilation system of an old hospital does not deliver the clean air to the operation area efficiently. A new air ventilation method which improves air venting with little increase of the cost of equipment is suggested.

  • PDF

A study on the photocatalyst filter design using UV-C (UV-C를 이용한 광촉매 필터 디자인에 관한 연구)

  • Han, Sang Yun;Kang, Seung Min
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.29 no.6
    • /
    • pp.276-282
    • /
    • 2019
  • The purpose of this study was to analyze the structure of general filter using ultrafine filter (Profilter), dust collector filter, HEPA (HAPA-High Efficiency Particulate Air) filter, deodorized filters, etc. of air purifiers and to study new types of purified filters that can improve ultrafine dust, harmful gases, and sterilization cleanup performance. The study was also conducted by adding photocatalyst filters to the existing step-by-step filtration filter types, which were proposed in the design three coupling structure filters of the left and right UV-LED installation frames and the photocatalyst coating honeycomb frame. Future research is needed on the effect of photocatalyst filters. This study was to investigate the application and structure of photocatalyst filters to air purifiers.

An Experimental Study on the Removal Characteristics of Indoor Air Pollutants using an Air Cleaning System (실내 공기정화 시스템에 의한 실내 오염입자의 제거특성에 관한 실험적 연구)

  • 김성찬;이창건;안영철;이재근;강태욱;이감규;구정환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.9
    • /
    • pp.733-737
    • /
    • 2003
  • The purpose of this study is to analyze the particle removal characteristics of a commercial air cleaner based on the electrostatic precipitator. The air cleaner consists of a positive corona precharger to precharge particles and a collector to remove the charged particles. The test for particle removal efficiency is conducted with tobacco smoke particles of 1.27${\mu}{\textrm}{m}$ in mass median diameter. The result of one-pass filtration test shows that the filtration efficiency is more than 90% for the particles larger than 2.5 Um, while the efficiency for the particles of 0.5~1.0${\mu}{\textrm}{m}$ in case of 4.18 CMM is 70%. For the test room of 5,800${\times}$3,400${\times}$2,600㎣, the concentration of tobacco smoke particles decreases up to 30% of initial values within 30 minutes due to natural reduction and up to 90% of initial values within 30 minutes with the air cleaner operation.

A Study on the Operational Variables of the UV-TiO$_2$ Based Photocatalytic Air Cleaning System (UV-TiO$_2$ 광촉매 기반의 공기 정화 시스템의 운전조건에 대한 연구)

  • Han, Chang-Seok;Chang, Hyuk-Sang
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.3
    • /
    • pp.293-301
    • /
    • 2008
  • A study on the operational variables of the UV-TiO$_2$ based photocatalytic air cleaning system was tried. In this study, to examine effects as various air cleaning system conditions, a duct-type reactor was made, and TiO$_2$ was immobilized on a stainless mesh. Benzene was chosen as a target compound. Removal experiments for benzene were done under different initial benzene concentration, air velocity, TiO$_2$ loading, area coated TiO$_2$ as the same TiO$_2$ loading, and UV light intensity conditions. During the experiments, relative humidity was 55%, and reactor temperature was 45$^{\circ}C$. As a result, the photocatalytic degradation of benzene decreased as the inlet concentration increased. But the photocatalytic degradation increased as the concentration boundary layer thickness, amount of TiO$_2$, area coated TiO$_2$ as the same amount of TiO$_2$, and UV light intensity increased. Based on results of current study, they can be applied to the design of air cleaning system over low level VOCs in the indoor air.

An Implementation of Inside Environment Purifying System Using ZIGBEE (ZIGBEE를 이용한 실내 환경 정화 시스템 구현)

  • Seo, Hyung-Yong;Lee, Jae-Heung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.447-450
    • /
    • 2005
  • This paper describes an implementation of system based on ZIGBEE wireless communication technique to prevent for diseases of skin ailments and respiratory ailments as sensing the air pollutions that breaks out in the inside and purifying. ZIGBEE wireless communication technique has features - low battery consumption, low cost, acceptance of the maximum 256 node and simple protocol structure of below 32Kbyte. Hardware platform is implemented by using ATmega128L in ATmel corporation and 2.4GHz RF-IC CC2420 in Chipcon corporation and dust sensor(GP2Y1010AU) and gas sensor(GSBT11) that confirm degree of inside air pollution for ZIGBEE wireless communication technique.

  • PDF

Production of air purification verification system using moss (이끼를 활용한 공기정화 검증 시스템 제작)

  • Ahn, Dohyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.587-591
    • /
    • 2019
  • Fine dust aerated in the atomsphere penetrates our lungs and blood lines through respiratory. Recent fine dust problems in Korea leads to development of various air purifiers. The researchers used this to study systems that could replace chemical filters. In order to compare the effect of the reduction of moss and conventional chemical filter(Hepa), a 1 cubic meter cube was prepared and the amount of the concentration of fine dust reduction was compared under controlled environment. Under the high concentration of fine dust, a test was done to figure out the reduction rate of the fine dust concentration by using air purification system with moss, hepa, and no filter. The air purification system(moss, hepa, and no filter) were operated 90 times in total, 30 times each. The test explains that the reduction of the fine dust amount and the rate of fine dust concentration. The results illustrate that the reduction of the amount fine dust was 138.93 after using air purification system with moss filter. In contrast, the usage of air purification system with hepa filter reduced the amount of fine dust to 76.57. And the air purification with no filter shows that the slight reduction of fine dust amount at 0.10. In the rate of fine dust concentration, moss filter was significantly higher than that of hepa, no filter (0.2379, 0.1298 and 0.0063 each). The results have confirmed that moss is effective in reducing fine dust concentration, and it is expected that with further improvement it can be used as a means to replace or supplement existing chemical filters in air purifier.

Initial Analysis of the Underground Air Among Jeju Lava Forest(Sumgol) and its Healing Effect on the Human Body (제주 현무암 '숲' 지하 공기(숨골: Sumgol)의 분석과 인체에 미치는 치유 효과)

  • Sin, SBangsik;Kim, Hyek Nyeon;Lee, Deok Hee;Kim, Tae Seung;Kim, Yong Hwan;Kang, Chang Hee;Song, Kyu Jin;Lee, Hyung H.
    • Journal of Naturopathy
    • /
    • v.11 no.1
    • /
    • pp.18-30
    • /
    • 2022
  • Background: It was to develop an air purification system (APS) using an underground air purification layer to verify the effect of basalt forest's underground air (sumgol) on a volcanic Jeju. Finally, it is necessary to analyze these purified air components and their usefulness to the human body in an air experience center. Purpose: It was to collect basalt forest air, analyze its composition, and explore its effect on the human body. Methods: We APS devices installed at four points in the Papaville area of Jeju. The air discharged from the APS was collected and analyzed the recycling components. An installed experience room filled with negative ions is about 5,000 ions/m3. After allowing the participants to stay for 60 to 120 minutes, we investigated the state of blood vessels. Results: In the analysis of the underground air, the O2 concentration was 21.18%, which was higher than the average oxygen concentration of 20.94% in the atmosphere. However, Formaldehyde was not detected, and the CO2 was 419 ppm, which was lower than that of indoor air. The PM2.5 concentration was less than 24 ㎍/m3 and detected anions over 5.000 /m3. The experiencer's vascular states improved, and the increase in pulse rate and stress relief were high. Conclusions: The valuable ingredients identified by analyzing the air were precious for natural healing. The experience results showed that it effectively improved the pulse rate, blood vessels, and stress. These conditions may be highly beneficial as a new area for expanding the basalt lava forest in the Jeju area into the natural healing and wellness industry.

Numerical Simulation of Flows inside the Various Rooms for Performance Assessment of Air Cleaning System (공기청정 시스템 성능예측을 위한 실내 유동현상에 관한 수치모사)

  • 손덕영;이두환;길재흥;최윤호;김동현
    • Journal of Energy Engineering
    • /
    • v.11 no.4
    • /
    • pp.306-316
    • /
    • 2002
  • ln this paper, flowfields inside the various rooms have been investigated. A storage room, a liv-ingroom with a kitchen in an apartment, and a hospital room are considered in the present calculations. In all cases, it was found that the average of air change rate is. similar to that of perfect mixing assumption and the location of air purifier has little effects on the average air change rate. Detailed local air concentrations show that there are regions where air is not quite purified because of non-uniform circulation of air flow. The location of air purifier has great effects on this behavior.

조사재시험시설 MUP 필터뱅크 현장 누설시험

  • Baek, Sang-Yeol;Kim, Gi-Ha;Song, Ung-Seop;An, Sang-Bok;Ryu, U-Seok
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2009.11a
    • /
    • pp.133-134
    • /
    • 2009
  • 조사 핵연료 및 구조재료의 핫셀시험을 위한 조사재시험시설은 고방사능물질의 시험 및 취급과정에서 발생한 각종 방사성 물질에 오염된 공기를 정회하기 위한 특수 공기조화설비를 운영하고 있다. 시설의 배기 계통은 핫셀 계통 및 핫셀 이외의 계통으로 니눠지고 있다. 그 중 핫셀 구역 이외의 공기는 1차적으로 프리필터와 HEPA 필터로 구성된 AFU(Air Filtering Unit)로 정화하여 외부에 방출하는 MUP(Medium Under Pressure) 시스템을 채용하고 있다. 외부에 방출하는 배기의 오염을 최소화하기 위하여 설치된 AFU에 대한 풍량 측정 및 HEPA필터의 성능시험을 실시하였으며, 그 결과에 대하여 고찰하였다.

  • PDF

Plant Growth Responses and Indoor Air Quality Purification in a Wall-typed Botanical Biofiltration System (벽면형 식물바이오필터 내 식물 생육 및 실내공기질 정화)

  • Jung, Seul Ki;Chun, Man Young;Lee, Chang Hee
    • Korean Journal of Plant Resources
    • /
    • v.28 no.5
    • /
    • pp.665-674
    • /
    • 2015
  • The final goal of this research is to develop a botanical biofiltration system, which combines green interior, biofiltering, and automatic irrigation, which can purify indoor air pollutants according to indoor space and the size of biofilter. The biofilter used in this experiment was designed as an integral form of water metering pump, water tank, blower, humidifier, and multi-level planting space in order to be more suitable for indoor space utilization. This study was performed to compare indoor air quality between the space adjacent to a botanical biofilter and the space away from the biofilter (control) without generation of artificial indoor air pollutants, and to evaluate plant growth depending on multiple floors within the biofilter. Each concentration of indoor air pollutants such as TVOCs, monoxide, and dioxide in the space treated with the biofilter was lower than that of control. Dracaena sanderiana ‘Vitoria’ and Epipremnum aureum ‘N Joy’ also showed normal growth responses regardless of multiple floors within the biofilter. Hence, it was confirmed that the wall-typed botanical biofilter suitable for indoor plants was effective for indoor air purification.