• Title/Summary/Keyword: 공기순환장치

Search Result 81, Processing Time 0.033 seconds

Performance of Airlift Pumps for Water Circulation and Aeration (물 순환 및 에어레이션용 에어리프트 펌프의 성능)

  • OH Se-Kyung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.25 no.6
    • /
    • pp.529-537
    • /
    • 1992
  • Airlift pumps were tested to evaluate their pumping and aeration capacities. The pumps were 34.5 inch long made of 2, 3, 4 and 6 inch nominal diameter PVC pipes. An one hp air blower was used to supply the air. The air-flow rate was measured by an anemometer type air-flow meter and air pressure was level changes in a water tank from which water was pumped. Aeration by the pumps was tested by the standard aeration test method with the center of pump outlet positioned 3 inches above water surface. Oxygen concentrations in water were measured to determine aeration rate. As pumping head increased by water level draw-down in the tank water flow decreased while air flow increased. The reduction rate of water flow was higher with 4 and 6-inch pumps. Small pumps showed very minor changes in the reduction. Aeration rates were similar among 3, 4, and 6 inch pumps. With one hp air blower 6-inch pump at the minimum pumping head achieved the best performance in terms of water circulation.

  • PDF

A Study on $CO_2$ and PM10 Changes by Operation of KTX HVAC-Pressurization Equipment in Tunnel Sections (터널구간 운행시 KTX HVAC-여압장치 작동에 따른 $CO_2$와 PM10 변화연구)

  • So, Jin-Sub;Yoo, Seong-Yeon
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.6
    • /
    • pp.723-729
    • /
    • 2007
  • The Ministry of Environment established a guide line in December 2006, "Indoor Air Quality Management guidelines in Public Facilities." As the items of the guideline, $CO_2$ (Carbon dioxide) and PM10 (particulate matter) is shown to Level 1 and 2. Therefore trains and subways are included. There are a lot of tunnels by the lay of mountains on KTX (Korean Train Express) service. HVAC (Heating Ventilating and Air-conditioning)-pressurization equipment on KTX is various functioning flaps blocking outside pressure waves. At that time, the fresh air is blocked by flap operation and the air is circulated by return air. In this study, we measured the time series of $CO_2$ and PM10 concentrations in the KTX passenger cabin during the train service of Gyongbu line (Seoul-Busan) and Honan line (Yongsan-Mokpo) from July 2006. Also, analyzed the air quality by operation of KTX HVAC-pressurization equipment in tunnel passing point. As a result, PM10 concentration was totally lower than the regulation values. However, $CO_2$ was highly correlated with several tunnels, such as Oksan-Otan, Godeung-Hyudae and Gaechak-Iijik tunnel. but, the indoor air quality of KTX train have been proved satisfy the recommendation the Ministry of Environment guidelines.

유도 결합 플라즈마원의 외부 냉각에 관한 수치 모델링

  • Ju, Jeong-Hun;Jo, Jeong-Hui;Park, Sang-Jong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.218-218
    • /
    • 2016
  • 실린더 형태의 유전체 관에 나선형으로 도전체 안테나를 설치하는 타입의 유도 결합 플라즈마원은 간단한 구조로 화학 조성 분석용부터 나노 분말 제조, 반도체용 식각/증착, 표면 처리, 자동차 및 일반 산업 부품용 증착 보조원등으로 널리 사용되고 있다. 고밀도 라디칼/이온의 공급을 위해서 투입 전력을 증가시키는 경우 높은 전력 밀도로 인해서 유전체 관에 인가되는 열응력이 대기압 및 관 고정용 구조물에 의한 구조 응력에 더해져서 파손에 이르는 경우가 발생될 수 있다. 실제 실린더 길이 전체를 안테나 코일로 감는 경우에도 플라즈마 발생 밀도가 높은 지역은 중심 일부 영역에 국한 되는 공정 영역도 있어서 이에 대한 분석이 필요하다. CFD-ACE+를 이용하여 플라즈마의 생성, 냉각수의 열전도, 외부 공냉식 팬의 역할등에 대해서 수치 모델을 작성하여 검토하였다. 나선형 냉각코일의 경우 냉각수량을 일정값 이상으로 증가시키는 경우 유속이 지나치게 빨라져서 열원이 있는 내경쪽 표면에서 열전도가 유속에 비례해서 증가하지 못하는 단점이 발생할 수 있으며 냉각팬의 경우 일반적으로 장치 내부에 대해서만 모델링을 하는 데 실제로 전체 시스템의 주변에서 공기의 흐름을 넓게 해석해야 실제 냉각 효과를 파악할 수 있다. 심한 경우 냉각용 공기 흡입구와 토출구의 간격이 좁아서 열원에 의해서 가열된 공기의 상당량이 다시 냉각용 공기 흡입구로 재순환 되는 경우도 발생하기 쉽다.

  • PDF

Evaluation of pure oxygen with MBR(Membrane Bio Reactor) process for anaerobic digester effluent treatment from food waste (순산소의 MBR(Membrane Bio Reactor) 공정 적용을 통한 음식물류 폐기물 혐기성소화 유출수 처리 평가)

  • Park, Seyong;Kim, Moonil;Park, Seonghyuk
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.29 no.3
    • /
    • pp.5-16
    • /
    • 2021
  • In this study, the applicability of the MBR(Membrane Bio Reactor) process of oxygen dissolve was evaluated through comparison and evaluation of the efficiency of oxygen dissolve device and conventional aeration device in the explosive tank within the MBR process. The organic matter and ammonia oxidation by oxygen dissolve device were evaluated, and the efficiency of persaturation was evaluated by applying real waste water (anaerobic digester effluent treatement from food waste). SCOD and ammonia removal rates for oxygen dissolve device and conventional aeration device methods were similar. However, it was determined that the excess sludge treatment cost could be reduced as the yield of microorganisms by oxygen dissolve device is about 0.03 g MLSS-produced/g SCOD-removed lower than that of microorganisms by conventional aeration device. The removal rates of high concentrations of organic matter (4,000 mg/L) and ammonia (1,400 mg/L) in anaerobic digester effluent treatment from food waste were compared to the conventional aeration device and the oxygen dissolve device organic matter removal rate was approximately 13% higher than that of the conventional aeration device. In addition, for MLSS, the conventional aeration device was 0.3 times higher than for oxygen dissolve device. This is believed to be due to the high progress of sludge autooxidation because the dissolved oxygen is sufficiently maintained and supplied in the explosive tank for oxygen dissolve device. Therefore, it was determined that the use of oxygen dissolve device will be more economical than conventional aeration device as a way to treat wastewater containing high concentrations of organic matter.

Design Method of Diffuse Bubble Plume Aerators for Water Quality Management of Reservoirs (저수지의 수질 관리를 위한 산기판형 인공 순환 장치의 설계 방법 개발)

  • Seo, Dongil;Song, Museok;Hwang, Hyundong;Choi, Jae-hun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.4
    • /
    • pp.437-444
    • /
    • 2004
  • To control algal bloom in reservoirs in Korea, artificial circulation systems have been applied. Diffuser block aeration systems have been increasingly used in Korean reservoirs especially for shallow ones. However, there has been no sound theoretical background for the design and operation of the system. Also there has not been sufficient post-installation studies to validate the effectiveness of the system. As a result, it has been repeatedly reported that the success of the system is not certain. Proper consideration on thermal stratification regimes of reservoirs and flow dynamics induced by bubble plumes are essential elements in design processes of the aeration system. This paper discusses the current methods in the design of diffuser type aeration system and suggests a new design method based on fluid mechanical theory. Example calculations were discussed using observed data of the Yeoncho Dam and it seems that the results represent the current situation successfully.

Smart Closet Design using IoT Sensor (IoT센서를 활용한 스마트 옷장 설계)

  • Jang, Eun-Gyeom;Kang, Moon-Su;Park, Sung-Hyun;Choi, Ji-Seok
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2022.07a
    • /
    • pp.463-464
    • /
    • 2022
  • 본 논문는 IoT 센서를 활용한 스마트 옷장을 연구하였다. 스마트 의류 관리 애플리케이션은 사용자가 등록한 옷을 카테고리별로 확인할 수 있으며, 기상청 API를 통한 날씨에 따른 의류 추천, 사용자가 착용한 의류 통계 정보와 의류 세탁 주기 정보를 제공한다. 스마트 옷장은 UV_LED를 활용한 의류 살균, 자동 미세먼지 감지 센서를 이용한 옷장 공기순환장치 기능을 제공한다. 또한 의류의 미세먼지 등을 제거할 수 있는 의류진동 기능을 제공한다. 애플리케이션 기능으로 옷을 등록할 때 옷을 계절별로 등록, 빨래 주기 설정 등 다양한 카테고리를 제공하여 기존 IoT 옷장의 기능을 개선하여 더 편리하게 의류를 관리할 수 있다.

  • PDF

Development of Ozone Plasma Sterilizer with Air Circulation Device (공기순환장치 적용 오존 플라즈마 살균장치 개발)

  • An, June;Chun, Young-Nam
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.31 no.1
    • /
    • pp.105-110
    • /
    • 2021
  • Objectives: The purpose of this study was to develop a new sterilization plasma device that would be proficient at sterilizing and removing pathogenic bacteria and viruses, and applicable to air purification systems. Methods: In order to understand the performance characteristics, the discharge characteristics of a packed bed DBD reactor and the ozone reduction characteristics of an ozone filter installed at the outlet of the reactor were investigated. Results: The novel packed-bed DBD reactor was proposed, and it was confirmed that the plasma discharge was uniformly and stably discharged throughout the entire layer, and sufficient ozone was generated for sterilization. The ozone filter was tested for three methods: adsorption, adsorption-decomposition, and catalytic decomposition. When the filter thickness was 30 mm, the ozone concentrations were 0.03 ppm, 0.01 ppm, and 0.21 ppm, respectively. The adsorption and adsorption-decomposition methods satisfied the EPA standard of less than 0.05ppm, but the catalytic decomposition method did not. Conclusions: It was confirmed that the adsorption-decomposition method has relatively excellent ozone filter performance and can provide the best ozone filter.

Prediction of Cooling Performance for Indirect Evaporative Cooling System Using Danpla Sheet (단프라시트를 적용한 간접식 증발냉각 장치의 냉각 성능 예측)

  • Kim, Myung-Ho;Kim, Byoung Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.892-897
    • /
    • 2020
  • Previous plastic heat exchangers are expensive because the mold must be newly manufactured depending on the air conditioning space. On the other hand, danpla is so thin that the heat exchange performance is excellent. Moreover, danpla can be used easily in ventilation systems in view of fabrication. This study proposes correlations for the cooling performance of an indirect evaporative cooling system. The experimental apparatus consisted of a heat exchanger, spray nozzle, fan, thermostat, pump, and measuring sensors for temperature, humidity, and airflow rate. The results showed that the effectiveness decreased gradually as the airflow rate increased. In addition, there was an optimal condition in terms of effectiveness. The performance prediction correlations were determined using the experimental data from various conditions. The proposed correlations showed performance accuracies within 4 % error.

Development of an Algorithm for Regulation of Inlet Blood Flow in Electrohydraulic Left Ventricular Assist Device Using Fuzzy Logic (퍼지로직을 이용한 전기유압식 좌심실 보조장치의 유입혈류량 조절 알고리즘의 개발)

  • Choi, Jae-Soon;Choi, Won-Woo;Jo, Yong-Ho;Park, Seong-Keun;Min, Byoung-Goo
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1995.10b
    • /
    • pp.387-392
    • /
    • 1995
  • 전기 유압식 좌심실 보조장치에서 모터 전류 파형을 정보로 하여 작동기의 이완기 속도를 조절함으로써 좌심방으로부터 유입되는 혈류량을 조절하는 알고리즘을 개발하였다. 좌심실 보조장치(Left Ventricular Assist Device, LVAD)는 허혈성 심장질환 등으로 좌심실 의 혈액 박출 기능이 저하된 환자에게 시술하여 정상 상태의 심박출량을 유지할 수 있도록 하는 보조 혈액 박출 기능이이다. 전기 유압식 좌심실 보조장치에서는 혈액의 유입이 능동 적으로 이루어지므로, 좌심방 함몰로 인한 심근 손상 및 외부 공기 유입으로 인한 색전증을 방지하기 위해 유입혈류량을 현재 좌심방내의 상태에 따라 적절히 조절해 주어야 한다. 좌 심방 내의 혈액량 정도는 혈액을 유입해 내는 작동기의 이완기 동작 시에 소모되는 에너지 크기에 반영되고, 작동기를 구동하는 모터에 들어가는 전류의 크기는 작동기에 공급되는 에 너지에 비례하므로, 이전류 파형의 정보들을 통해 좌심방내의 상태를 추정해 볼 수 있다. 본 논문에서는 퍼지로직을 적용하여 모터 전류 파형의 정보들을 통해 좌심방 내의 상태를 추정 해 볼 수 있다. 본 논문에서는 퍼지로직을 적용하여 모터 전류 파형의 이상 유무를 판단한 뒤 에에 따라 작동기의 이완기 속도를 조절하는 알고리즘을 개발하여 모의순환장치 실험을 통해 그 실효성을 검증한 결과를 정리하였다.

  • PDF

A Numerical Study on the Performance Analysis of a Solar Air Heating System with Forced Circulation Method (강제순환 방식의 공기가열식 태양열 집열기의 성능분석에 관한 수치해석 연구)

  • Park, Hyeong-Su;Kim, Chul-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.122-126
    • /
    • 2017
  • The aim of this study was to develop a device for solving the heating problem of living space using heated air, utilizing a simple air heater type collector for solar energy. At the present time, this study assessed the possibility of a development system through theoretical calculations for the amount of available energy according to the size change of the air-heated solar energy collector. To produce and supply hot water using the heat energy of the sun, hot water at $100^{\circ}C$ or less was produced using a flat or vacuum tube type collector. The purpose of this study was to research the air heating type solar collector that utilizes heating energy with heating air above $75^{\circ}C$, by designing and manufacturing an air piping type solar collector that is a simpler type than a conventional solar collector system. The analysis results were obtained for the generated air temperature ($^{\circ}C$) and the production of air (kg/h) to determine the performance of air heating by an air-heated solar collector according to the heat transfer characteristics in the collector of the model when a specified amount of heat flux was dropped into a solar collector of a certain size using PHOENICS, which is a heat flow analysis program applying the Finite Volume Method. From the analysis result, the temperature of the air obtained was approximately $40.5^{\circ}C$, which could be heated using an air heating tube with an inner diameter of 0.1m made of aluminum in a collector with a size of $1.2m{\times}1.1m{\times}0.19m$. The production of air was approximately 161 m3/h. This device can be applied to maintain a suitable environment for human activity using the heat energy of the sun.