• 제목/요약/키워드: 공극 편심

검색결과 10건 처리시간 0.02초

경사 편심에 의한 유도전동기의 자기흡인력 평가 (Calculation of Unbalanced Magnetic Pull of Induction Motors due to Rotor Misalignment)

  • 김선화;양보석;김현철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1321-1327
    • /
    • 2006
  • This paper presents the calculation of unbalanced magnetic pull (UMP) that causes rotor misalignment in induction motor. The excessive noise and vibration will be occurred by means of rotor misalignment. Angular misalignment of rotor will produce air-gap permeance wave which is function of axial and circumferential coordinate. In this paper, the UMP is calculated using permeance and magneto motive force (MMF) in the case of static and dynamic misalignment. Based on the percentage of misalignment, the result shows that the UMP and magnetic pressure are increased according to the increasing of misalignment. The UMP is occurred not only in It frequency component but also the others.

  • PDF

신경회로망을 이용한 유도전동기의 결함진단에 관한 연구 (A Study on the Failure Diagnosis of Induction Motor using Neyral Networks)

  • 양보석;김남설
    • 한국지능시스템학회논문지
    • /
    • 제5권4호
    • /
    • pp.56-66
    • /
    • 1995
  • 본 논문에서는 산업용으로서 널리 이용되고 있는 3상 유도전동기의 전기적 결함에 의해 발생하는 전자진동문제을 체계적으로 검토하고, 이들 진동신호의 주파수스펙트럼을 사용한 전동기의 결함진단 시스템을 신경회로망을 이용하여 구축하였다. 그리고 그 중에서 비교적 자주 발생하는 공극(air-gap)의 정적 편심에 대해 실험을 수행하고, 그 결과를 신경회로망을 이용한 진단법에 적용하여 본 진단법의 유용성을 확인하였다. 또한 현장에서 발생된 전기적인 결함에 대한 진동측정 data를 이용하여 진단이 정상적으로 수행되는가를 조사하여 각 결함을 정확하게 판별할 수 있음을 입증하였다.

  • PDF

이상진동에 의한 유동전동기의 진단 (Diagnosis for Induction Motor from Abnormal Vibration)

  • 양보석;김남설;장우교;신광재
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1994년도 춘계학술대회논문집; 영남대학교, 20 May 1994
    • /
    • pp.122-127
    • /
    • 1994
  • 본 논문에서는 산업용으로서 널리 이용되고 있는 3상 유도전동기의 전기적결함에 의해 발생하는 전자진동문제를 체계적으로 검토하고, 이를 이용하여 전동기 진동이 진단법을 신경회로망을 이용하여 구축한다. 그리고 그중에서 비교적 자주 발생하는 공극(air-gap)의 정적편심에 대해 실험을 수행하고, 그 결과를 신경회로망을 이용한 진단법에 적용하여 본 진단법의 유용성을 확인한다. 또한 현장에서 발생된 전기적인 결함에 대한 진동측정 data를 이용하여 진단이 정상적으로 수행되는가를 조사하여 본 진단법의 가능성을 조사한다.

  • PDF

회전자 편심과 슬롯의 영향에 의한 공극의 자속밀도분포 해석 (Analysis of air gap flux density distribution by the rotor eccentricity and slot effects)

  • 이은웅;조현길;김종겸
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.39-42
    • /
    • 1995
  • This paper analyzes air gap flux density of the induction motor with the rotor eccentricity and slot effects using Fourier series and FEM. We establishes the validity of results by analyzing the space harmonic order.

  • PDF

전류신호를 이용한 유도전동기의 회전자봉 결함검출에 관한 연구 (A Study on Detection of Broken Rotor Bars in Induction Motors Using Current Signature Analysis)

  • 신대철;정병훈
    • 한국소음진동공학회논문집
    • /
    • 제12권4호
    • /
    • pp.287-293
    • /
    • 2002
  • The unexpected failure of the induction motor makes the downtime of production, and the cost of the process cessation enormous. To reduce the downtime and increase the reliability of the motor, the vibration measurements for the fault detection have been used previously. Recently motor current signature analysis(MCSA) has been adapted for the fault detection and diagnosis of the motors. MCSA provides a powerful analysis tool for detecting the presence of mechanical and electrical faults in both the motor and driven equipment. In this paper, the fault severity of the rotor bar has been derived in terms of the resistance change which is calculated from the equivalent circuit model. Results show that the fault of the rotor can be easily detected and the measured value of the resistance change is verified by the detected fault from on-site tests using MCSA for the induction motors in an iron foundry.

BLDC 모터를 적용한 로터리 컴프레서 소음 저감에 관한 연구 (Study on the Noise Reduction in the Rotary Compressor using BLDC Motor)

  • 김진수;임경내;구세진;이장우;전시문
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.674-681
    • /
    • 2008
  • The main noise source of the BLDC rotary compressor for air conditioner was analyzed by using the measurement of noise and vibration, noise contour, and experimental modal analysis. The source is presumed to the mechanical resonance excited by the electromagnetic attractive force of the BLDC motor. To reduce the excessive noise of the BLDC rotary compressor due to the mechanical resonance, air-gap was enlarged. Its validation was conducted by the analysis of the electromagnetic attractive force which is generated by the BLDC motor. By enlarging the length of air-gap, the noise in the compressor and air conditioner was significantly improved by 2.5dB(A) and 4.5dB(A), respectively.

  • PDF

전류분석을 이용한 유도 전동기의 결함분석 알고리듬 개발 (A Development of the Algorithm to Detect the Fault of the Induction Motor Using Motor Current Signature Analysis)

  • 신대철;정병훈
    • 한국소음진동공학회논문집
    • /
    • 제14권8호
    • /
    • pp.675-683
    • /
    • 2004
  • The motor current signature provides an important source of the information for the faults diagnosis of three-phase induction motor. The theoretical principles behind the generation of unique signal characteristics, which are indicative of failure mechanisms, are Presented. The fault detection techniques that can be used to diagnose mechanical Problems, stator and rotor winding failure mechanisms, and air-gap eccentricity are described. A theoretical analysis is presented which predicts the presence of unique signature patterns in the current that are only characteristics of the fault. The predictions are verified by experimental results from a special fault Producing test rig and on-site tests in a steel company. And this study have made new diagnostic algorithm for the operating induction motors with the test results. These developments are including the use of monitoring and analysis of electric current to diagnose mechanical and electrical problems and gave the precise test results automatically.

유도형 모터의 회전자 편심과 운전상태를 고려한 공극 자속 밀도의 해석과 특성시험 (Analysis of air gap flux density and Test of characteristics of the induction motor considering mechanical unbalance of a rotor and driving condition)

  • 장석명;이성래;이성호;박윤식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.76-78
    • /
    • 1998
  • Noise and vibration are one of the most unpleasant hazards of driving motors. Therefore, it is important to reduce noise and vibration. To do so, we need to analysis cause of those. This paper presents one of the process that search for the cause.

  • PDF

BLDC 모터를 적용한 로터리 컴프레서 소음 저감에 관한 연구 (Study on the Noise Reduction in the Rotary Compressor Using BLDC Motor)

  • 김진수;임경내;구세진;이장우;전시문
    • 한국소음진동공학회논문집
    • /
    • 제18권9호
    • /
    • pp.920-929
    • /
    • 2008
  • The main noise and vibration source of the BLDC rotary compressor for air conditioner was analyzed by using the measurement of noise and vibration, noise contour, and experimental modal analysis. The source is presumed to the mechanical resonance excited by the electromagnetic attractive force of the BLDC motor. To reduce the excessive noise of the BLDC rotary compressor due to the mechanical resonance, air-gap enlargement and structural dynamic modification were applied in this paper. Its validations were conducted by the analysis of the electromagnetic attractive force which is generated by the BLDC motor and by the measurement of noise and vibration of the BLDC rotary compressor. By enlarging the length of air-gap and conducting the structural dynamic modification, the noise and vibration in the compressor was significantly improved by 4.5 dB(A) and 56 percent, respectively.

전류신호 분석을 통한 저널베어링 이상상태 진단 (Diagnosis of a Journal Bearing Fault via Current Signature Analysis)

  • 박진석;허형;정경훈;이규만;박근배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.119-122
    • /
    • 2005
  • A study on motor current signature analysis has been executed for monitoring the fault of journal bearing due to wear. The air gap eccentricity of motor produces specific frequencies in motor current, the supplied current frequency plus and minus rotational rotor frequency. The air gap eccentricity is simulated by the clearance of Journal bearing. The amplitudes of the specific frequencies increase with the increasing clearances. The amplitudes of the specific frequencies continue to increase over the wear limit that is used in the manufacturer of the test motor. Though clear relations between the amplitudes of the specific frequencies and the clearances are not obtained in this paper, the specific frequencies can be used as an indicator of a journal bearing fault. Further study is necessary to make out the quantitative relations between the specific frequencies and the clearances.

  • PDF