• Title/Summary/Keyword: 공극 규모

Search Result 64, Processing Time 0.028 seconds

Pore-scale Investigation on Displacement of Porewater by Supercritical CO2 Injection Using a Micromodel (초임계상 이산화탄소 주입으로 인한 공극수 대체에 관한 공극 규모의 마이크로모델 연구)

  • Park, Bogyeong;Lee, Minhee;Wang, Sookyun
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.3
    • /
    • pp.35-48
    • /
    • 2016
  • A micromodel was applied to estimate the effects of geological conditions and injection methods on displacement of resident porewater by injecting scCO2 in the pore scale. Binary images from image analysis were used to distinguish scCO2-filled-pores from other pore structure. CO2 flooding followed by porewater displacement, fingering migration, preferential flow and bypassing were observed during scCO2 injection experiments. Effects of pressure, temperature, salinity, flow rate, and injection methods on storage efficiency in micromodels were represented and examined in terms of areal displacement efficiency. The measurements revealed that the areal displacement efficiency at equilibrium decreases as the salinity increases, whereas it increases as the pressure and temperature increases. It may result from that the overburden pressure and porewater salinity can affect the CO2 solubility in water and the hydrophilicity of silica surfaces, while the neighboring temperature has a significant effect on viscosity of scCO2. Increased flow rate could create more preferential flow paths and decrease the areal displacement efficiency. Compared to the continuous injection of scCO2, the pulse-type injection reduced the probability for occurrence of fingering, subsequently preferential flow paths, and recorded higher areal displacement efficiency. More detailed explanation may need further studies based on closer experimental observations.

Evaluation of the CO2 Storage Capacity by the Measurement of the scCO2 Displacement Efficiency for the Sandstone and the Conglomerate in Janggi Basin (장기분지 사암과 역암 공극 내 초임계 이산화탄소 대체저장효율 측정에 의한 이산화탄소 저장성능 평가)

  • Kim, Seyoon;Kim, Jungtaek;Lee, Minhee;Wang, Sookyun
    • Economic and Environmental Geology
    • /
    • v.49 no.6
    • /
    • pp.469-477
    • /
    • 2016
  • To evaluate the $CO_2$ storage capacity for the reservoir rock, the laboratory scale technique to measure the amount of $scCO_2$, replacing pore water of the reservior rock after the $CO_2$ injection was developed in this study. Laboratory experiments were performed to measure the $scCO_2$ displacement efficiency of the conglomerate and the sandstone in Janggi basin, which are classified as available $CO_2$ storage rocks in Korea. The high pressurized stainless steel cell containing two different walls was designed and undisturbed rock cores acquired from the deep drilling site around Janggi basin were used for the experiments. From the lab experiments, the average $scCO_2$ displacement efficiency of the conglomerate and the sandstone in Janggi basin was measured at 31.2% and 14.4%, respectively, which can be used to evaluate the feasibility of the Janggi basin as a $scCO_2$ storage site in Korea. Assuming that the effective radius of the $CO_2$ storage formations is 250 m and the average thickness of the conglomerate and the sandstone formation under 800 m in depth is 50 m each (from data of the drilling profile and the geophysical survey), the $scCO_2$ storage capacity of the reservoir rocks around the probable $scCO_2$ injection site in Janggi basin was calculated at 264,592 metric ton, demonstrating that the conglomerate and the sandstone formations in Janggi basin have a great potential for use as a pilot scale test site for the $CO_2$ storage in Korea.

Enhanced Removal of Benzene-NAPL in Soil using Concurrent Injection of Cosolvent and Air (Cosolvent와 공기 동시 주입 공정에 의한 토양 내 벤젠-NAPL 세정 증대 연구)

  • Song, Chung-Hyun;Jeong, Seung-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.11
    • /
    • pp.1095-1101
    • /
    • 2008
  • Nonaqueous phase liquids (NAPL) are the continuous source for soil and groundwater contamination. The first objective of the study was to verify the effect of co-injection of cosolvent and air on NAPL removal from soil-column system. The second objective of the study was to investigate the effect of alcohol-partitioning property on the NAPL removal by the co-injection process of cosolvent and air. Enhanced removal of benzene-NAPL by the co-injection process of ethanol and air was also verified within the soilcolumn system. However, the co-injection process of Tert-butanol (TBA) and air showed no enhancement of benzene-NAPL removal. This study found that the viscous pressure of TBA was so higher than the capillary pressure and TBA easily displaced the benzene-NAPL and air present in soil pores. Air of the coinjection process did not work for NAPL removal but hindered NAPL mobilization. NAPL partitioning property and viscous pressure of cosovlent should be considered for application of the co-injection process of cosolvent and air.

Feasibility of Pyrophyllite Ceramic Membrane for Wastewater Treatment and Membrane Fouling (국내산 납석기반 세라믹 멤브레인 수처리 적용 가능성 평가 및 파울링 현상관찰)

  • Park, Eunyoung;Jang, Hoseok;Choi, Nakcheol;Lee, Sungjae;Kim, Jeonghwan
    • Membrane Journal
    • /
    • v.26 no.3
    • /
    • pp.205-211
    • /
    • 2016
  • Performance of pyrophyllite-based ceramic membranes newly developed were investigated. Membrane fouling caused by microbial suspensions taken from a full-scaled MBR system at domestic wastewater treatment plant was observed at different airflow rate and distance between each membrane. For the pyrophyllite support, pore size was about $1.0{\mu}m$, but surface coating with $Al_2O_3$ solution decreased the pore size with the reduction of the pure water permeability. With the MLSS taken from the full-scaled MBR system (6 g/L), the fouling rate was decreased by increasing airflow rate under $20L/m^2{\cdot}hr$ of setpoint flux. However, the effectiveness of the airflow rate on the fouling control depends strongly upon the gap between each membrane. At fixed airflow rate, the fouling rate was decreased by increasing the gap between each pyrophyllite membrane. Nevertheless, further increasing the membrane distance from 3.5 to 5.4 cm resulted in higher fouling rate. Similar result was observed with the $Al_2O_3$ coated-pyrophyllite membrane. Nevertheless, the fouling rate was lower with the coated membrane than that observed with the uncoated pyrophyllite support. Regardless of surface coating, the suspended solids were removed almost completely and the surface coating on the pyrophyllite support improved organic rejection with PEG solution (MW : 8000 kDa) tested.

Estimation of Denitrification in the Ganghwa Tidal Flat by a Pore Water Model (공극수 모델로 추정한 강화도 갯벌의 탈질산화 작용)

  • Na, Tae-Hee;Lee, Tong-Sup
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.10 no.1
    • /
    • pp.56-68
    • /
    • 2005
  • We measured nitrate and other nutrients in sediment pore waters retrieved from three sites at the southern upper-tidal flats of the Ganghwa Island. Denitrification rate is estimated by applying a simple 1-D model to the nitrate profiles. Results from Jangwha and Dongmak sites are $7.8{\sim}9.4{\times}10^{-7}{\mu}mol{\cdot}cm^{-2}{\cdot}sec^{-1}$, and $1.4{\sim}3.6{\times}10^{-7}{\mu}mol{\cdot}cm^{-2}{\cdot}sec^{-1}$, respectively. Rates are comparable to those reported around the world in an order of magnitude. Denitrification was lower in summer. The rates were about 1.5 times higher at site where the surface sediments consist of relatively coarser particles. This implies that particle size would control the reactant supply to the subsurface sediment. One may claim the denitrification as an evidence of the biogeochemical purification function of tidal flat. However, the purification seems not a general attribute of a tidal flat when whole system is scrutinized by a thermodynamic criterion. Currently the term 'tidal flat' is used when describing the diverse coastal wetlands such as salt marshes, sandy tidal flats and muddy tidal flats, which exhibit quite different ecological functions. Thus it is worthy of mentioning that the classification of coastal wetlands on the basis of sedimentological characteristics and biogeochemical functions should facilitate our understanding.

Clogging Potential in Constructed Vertical Flow Wetlands Employing Different Filter Materials for First-flush Urban Stormwater Runoff Treatment (도시 초기 강우유출수 처리를 위한 수직흐름습지에서 여재별 폐색 잠재성 분석)

  • Chen, Yaoping;Guerra, Heidi B.;Kim, Youngchul
    • Journal of Wetlands Research
    • /
    • v.20 no.3
    • /
    • pp.235-242
    • /
    • 2018
  • The function of vertical subsurface flow wetlands can potentially be reduced with time due to clogging and are often assumed to be occurring when ponding and overflow is observed during rainfall. To investigate their clogging potential, three pilot-scale vertical subsurface flow (VSF) wetland systems were constructed employing woodchip, pumice, and volcanic gravel as main media. The systems received stormwater runoff from a highway bridge for seven months, after which the media were taken out and divided into layers to determine the amount and characteristics of the accumulated clogging matters. Findings revealed that the main clogging mechanism was the deposition of suspended solids. This is followed by the growth of biofilm in the media which is more evident in the wetland employing woodchip. Up to more than 30% of the clogging matter were found in the upper 20 cm of the media suggesting that this layer will need replacement once clogging occurs. Moreover, no signs of clogging were observed in all the wetlands during the operation period even though an estimation of at least 2 months without clogging was calculated. This was attributed to the intermittent loading mode of operation that gave way for the decomposition of organic matters during the resting period and potentially restored the pore volume.

A Study of Hydrodynamics and Reaction Characteristics in Relation to the Desulfurization Temperatures of Zn-Based Solid Sorbent in the Lab-scale High Pressure and High Temperature Desulfurization Process (실험실규모 고온고압건식탈황공정의 수력학적 특성 및 탈황온도에 따른 아연계 탈황제의 반응특성 연구)

  • Kyung, Dae-Hyun;Kim, Jae-Young;Jo, Sung-Ho;Park, Young Cheol;Moon, Jong-Ho;Yi, Chang-Keun;Baek, Jeom-In
    • Korean Chemical Engineering Research
    • /
    • v.50 no.3
    • /
    • pp.492-498
    • /
    • 2012
  • In this study, hydrodynamics such as solid circulation rate and voidage in the desulfurizer and the reaction characteristics of Zn-based solid sorbents were investigated using lab-scale high pressure and high temperature desulfurization process. The continuous HGD (Hot Gas Desulfurization) process consist of a fast fluidized bed type desulfurizer (6.2 m tall pipe of 0.015 m i.d), a bubbling fluidized bed type regenerator (1.6 m tall bed of 0.053 m i.d), a loop-seal and the pressure control valves. The solid circulation rate was measured by varying the slide-gate opening positions, the gas velocities and temperatures of the desulfurizer and the voidage in the desulfurizer was derived by the same way. At the same gas velocities and the same opening positions of the slide gate, the solid circulation rate, which was similar at the temperature of $300^{\circ}C$ and $550^{\circ}C$, was low at those temperatures compared with a room temperature. The voidage in the desulfurizer showed a fast fluidized bed type when the opening positions of the slide gate were 10~20% while that showed a turbulent fluidized bed type when those of slide gate were 30~40%. The reaction characteristics of Zn-based solid sorbent were investigated by different desulfurization temperatures at 20 atm in the continuous operation. The $H_2S$ removal efficiency tended to decrease below the desulfurization temperature of $450^{\circ}C$. Thus, the 10 hour continuous operation has been performed at the desulfurization temperature of $500^{\circ}C$ in order to maintain the high $H_2S$ removal efficiency. During 10 hour continuous operation, the $H_2S$ removal efficiency was above 99.99% because the $H_2S$ concentration after desulfurization was not detected at the inlet $H_2S$ concentration of 5,000 ppmv condition using UV analyzers (Radas2) and the detector tube (GASTEC) which lower detection limit is 1 ppmv.

Chemical Washing of PAH-Contaminated Soil with Cyclodextrins as a Main Surfactant: A Labscale Study (사이클로덱스트린을 이용한 PAH오염토양의 화학적 세정)

  • Sung Hyun Kwon;Daechul Cho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.4
    • /
    • pp.295-302
    • /
    • 2002
  • PAHs (polycyclic aromatic hydrocarbons) deposited in soil are one of serious problems against sustainable land use. In this paper, chemical soil flushing in a packed sandy soil matrix using a natural surfactant, $\beta$-cyclodextrin (CD) was studied via a fluorescence spectroscopy and a dye labelling. The contaminants are lipophilic ring compounds- phenanthrene and naphthalene. Sand type and flushing intensity (rate and concentration) are chosen as important investigation variables. The removal efficiencies were proportional to flow rate, concentration, temperature of the flushing solution and voidity of the sand column. Initial sorption of the surfactant onto the soil matrix was found to be a key step while flow shear was more crucial in the latter steps. The residual portion of the surfactant, which was most likely to be due to the initial sorption, would not be so influential on this type of soil washing for long times. These results will be useful in future for pilot scale in situ washing and for establishing better soil washing strategy.

  • PDF

Thermal-Hydro-Mechanical Behaviors in the Engineered Barrier of a HLW Repository: Engineering-scale Validation Test (고준위폐기물처분장 공학적방벽의 열-수리-역학적 거동 연구: 엔지니어링 규모의 실증실험)

  • Lee, Jae-Owan;Cho, Won-Jin
    • Tunnel and Underground Space
    • /
    • v.17 no.6
    • /
    • pp.464-474
    • /
    • 2007
  • An enhancement in the performance and safety of a high-level waste repository requires a validation of its engineered barrier. An engineering-scale test (named "KENTEX") has been conducted to investigate the thermal-hydro-mechanical behaviors in the engineered barrier of the Korean reference disposal system The validation test started on May 31, 2005 and is still under operation. The experimental data obtained allowed a preliminary and qualitative interpretation of the thermal-hydro-mechanical behaviors in the bentonite blocks. The temperature was higher as it became closer to the heater, while it became lower as it was farther away from the heater. The water content had a higher value in the part close to the hydration surface than that in the heater part. The relative humidity data suggested that a hydration of the bentonite blocks might occur by different drying-wetting processes, depending on their position. The total pressure was continuously increased by the evolution of the saturation front in the bentonite blocks and thereby the swelling pressure. Near the heater region, there was also a significant contribution of the thermal expansion of bentonite and the vapor pressure in the pores of the bentonite blocks.

Development of a prefabricated rainwater infiltration storage block for reducing rainfall-runoff (우수유출저감을 위한 조립식 빗물 침투형 저류블록의 개발)

  • Koh, Byoung-Ryoun;Choi, Hee-Yong;Cha, Jung-Mann
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.360-360
    • /
    • 2020
  • 조립식 빗물침투형 저류블록은 우수유출 저감시설로, 황토 및 친환경 무기질 결합재를 이용하여 제작한 고강도 투수성 블록의 적층 및 요철에 의한 끼움식 조립에 의해 형성된 공간에 빗물을 저류하고, 저장된 빗물은 시간이 지남에 따라 지반으로 침투시키는 우수유출 저감용 빗물관리시설로, 집중강우 시 유출수가 발생하는 해당지역에 분산식으로 설치하여 국지적 호우 발생에 대처할 수 있으며, 지속적인 침투를 통한 지하수위 확보 및 가뭄현상의 저감은 물론, 미기후 조성과 건전한 물순환 구조 형성에 이바지하는 빗물관리기술이다. 본 기술은 집중형 대규모 빗물저류조의 적용상의 문제점과 단순저류의 한계성을 극복하고, 기존 침투시설의 낮은 침투능을 증대시키고자 저류기능과 침투기능을 동시에 확보하여 집중호우시 빠른 침투저류능을 향상시킨 조립식 빗물침투형 저류시설이다. 보다 구체적으로는 집중강우에 대한 방재적 측면과 함께 가뭄으로 발생하는 지하수위 저하 등에 친환경적으로 대응하기 위한 복합적인 빗물관리 기술로서, 빗물 유출저감과 함께 물순환 회복 및 저영향개발을 위한 각 지자체의 지침과도 부합될 수 있다. 또한, 콘크리트 제품의 환경적 문제점과 플라스틱 제품의 낮은 물성을 극복하였고, 시공 시에는 보다 현장상황에 맞게 가변적 형태로 적용이 가능한 단순조립 적층공법으로 공기단축에 탁월한 장점이 있으며, 유지관리 시에는 별도의 동력이 요구되지 않는 형태로 개발하였다. 조립식 빗물침투저류블록의 구조체를 이루는 단위 블록유닛은 투수성 소재로 제작되며, 상하부가 개방되어 있고 사각형의 내부에 힘을 받는 격벽과 전후벽이 상호 대응되는 요철로 형성되어 있으며, 단위블록 유닛 다수개가 수직수평으로 연속적으로 조립되어 규모의 제한, 형태의 제한이 없는 구조물 형성이 가능하다. 본 구조체의 저류공극율은 80%이상 확보 가능하며, 또한 블록자체의 투수율이 0.83mm/sec로서 순모래나 순자갈의 포화투수계수보다 투수율이 높아 침투저류 효율성이 높으며 시공 후 상부 토지는 자유롭게 활용 가능하다. 본 조립식 빗물 침투형 저류블록을 이용하여 저영향개발 계획, 우수유출 저감대책 수립, 빗물관리시설 계획시 기존의 시설들에 비하여 경제적, 효율적인 설계가 가능하다.

  • PDF