• Title/Summary/Keyword: 공간살균

Search Result 20, Processing Time 0.027 seconds

Study of an Optical Approach to Ultraviolet Irradiance for Space Sterilization Using a UV LED Light Source (UV LED 광원을 이용한 공간 살균을 위한 자외선 조사량 밀도의 광학적 연구)

  • Jong-Tae Kim
    • Korean Journal of Optics and Photonics
    • /
    • v.35 no.5
    • /
    • pp.235-240
    • /
    • 2024
  • Since the coronavirus pandemic, research and application of space sterilization effects using UV light sources have been rapidly increasing. In this paper, the space-sterilization effect of UV LED light sources that can be built into indoor environmental systems or lighting devices is quantitatively analyzed through an illumination optical approach. Through this, it is possible to establish a foundation for optimizing the sterilization effect in indoor spaces in the 275±5 nm wavelength range, which is known to have excellent space-sterilization power.

A study of the space sterilization device using atmospheric-pressure DBDs plasma (대기압 유전체장벽방전을 적용한 플라즈마오존 공간살균장치에 관한 연구)

  • Oh, Hee-Su;Lee, Kang-yeon;Park, Ju-Hoon;Jeong, Byeong-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.3
    • /
    • pp.281-289
    • /
    • 2022
  • Plasma ozone is utilized in a variety of applications in the field of sterilization due to its high sterilization performance. Dielectric materials used in DBD(dielectric barrier discharges) are mainly polymer, quartz and ceramics. These dielectric layers have the advantage of limiting the amount of supplied electron charge and allowing plasma to occur evenly on the surface of dielectric. Actually, the target or environment for sterilization is often a complex structure, so research and academic study are needed by utilizing the concept of space sterilization. In this study, the device is applied to generate DBD plasma at atmospheric pressure for disinfection due to the effectiveness in producing radicals and ozone. The generator of plasma ozone is a basic structure of dielectric barrier discharge by placing ceramic tube dielectrics and stainless steel electrical conductors at regular intervals. Various applications can be developed based on the proposed design method. Plasma ozone generation for space sterilization device is recognized as an excellent sterilization device. Through the design and verification of the device, we intend to establish an optimal design of the spatial sterilization device and provide the basis data for sterilization applications.

The status and future of the geomatics - about satellite geodesy and remote sensing (공간정보기술의 현황 및 전망 - 위성측지 및 원격탐사를 중심으로)

  • 안철호
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2002.04a
    • /
    • pp.3-10
    • /
    • 2002
  • 요즘 측량분야에서 Geomatics 또는 Geoinformatics라는 새로운 용어가 대두되고 있다. 해외의 유수 기관 및 대학교에서도 측량이라는 학과명 또는 기관명을 Geomatics라는 용어로 교체하고 있으며, 이는 측량분야의 다양화와 학제간 연구수행의 필요성을 반영하는 것이다. 최근 45로 일컬어지는 GPS, 원격탐사(RS), GIS, ITS의 경우 각기 독자적인 영역을 구축하기보다는 상호 보완적인 역할을 하며 통합되어 가는 추세이다. 1950년대에 기본적인 위성관측기술 및 계산 기술의 개발을 시작으로 1980년대에 이르러서는 위성 기술은 측지학 및 측량 분야에 적용되기 시작했다. 그 대표적인 것이 GPS(Global Positioning System)로 기존의 천체측정학 방식을 대체하는 유용한 위치결정 수단으로 사용되기 시작했다. DNSS로부터 시작된 GPS는 측지 측량분야, 지구물리학분야, 항법 및 교통, GIS Mapping, 기상 및 해양, 재난 및 레저, 인공위성 궤도결정 등 다양한 분야에 적용되었으며, 특히 2000년 5월 1일 SA가 해제되면서 그 활용도는 더욱 증가하고 있다. 위성원격탐사의 경우 초창기에 중ㆍ저해상도의 다중분광영상에서 시작하여 그 해상도가 꾸준히 향상되어 오늘날 0.61 미터급 고해상도 위성인 QuickBird 위성이 발사되어 운용 중에 있다. 위성영상의 공간해상도, 분광해상도, 방사해상도는 향후 계속 향상될 것이며 이에 따른 방대한 데이터의 처리 문제 및 하드웨어/소프트웨어 지원에 대한 연구가 수반되어야 할 것이다. GPS 및 원격탐사(RS)는 더 이상 독자적인 영역으로서가 아니라 Geomatics를 이루는 중요한 분야로서 타 시스템과의 보완적인 관계로서 통합되어 나갈 것이다. 이를 위해서는 공간정보에 대한 표준화 및 데이터 처리, 통합, 시스템 구축을 위한 기술적 연구가 계속 진행되어야 할 것이다.분 공부상면적보다 늘어났다. 2. 좌표의 이동량이 일률적이지 못하므로 기초점에 대한 문제라고 생각되며, 따라서 도해지적을 수치지적으로 전환함에 있어서 가장 우선되어야 할 사항이 기초점 정비라 하겠다.승이 뚜렷하였다. 따라서 비파 착즙액 첨가 기능성 yoghurt 제조시 비파 착즙액을 10% 첨가하여 혼합 starter로 Str. thermophilus와 Lac. acidophilus 혼합균주를 사용하는 것이 이들 유산균의 증식에 가장 적합한 것으로 나타났다.타났다..297, 0.293, 0.205에서 50일 경과 후 0.612, 0.472, 0.898로 비살균에서 높은 값을 보였다. 따라서 비살균의 경우 저장말기에 TBA값이 높아지는 경향을 보였다. 5. L값은 살균처리의 경우 저장 30일 이후 약간 어두워지는 경향을 보였고, 121$^{\circ}C$ 살균처리에서 높은 값을 보였다. 대체로 저장온도가 높고 저장기간이 길어질수록 약간 밝아지는 경향을 보였다. 적색도는 인삼 첨가구의 경우 상온 및 냉장저장에서 10$0^{\circ}C$ 살균이 121$^{\circ}C$ 처리구 보다 약간 높은 값을 보였다. 저장기간에 따른 적색도의 변화는 인삼과 송이 첨가구에서 비교적 안정적이었다. 황색도는 상온 및 냉장저장에서 저장기간에 따라 약간 감소하는 경향을 보인 후 상온저장 50일 째, 냉장 60일 째 가장 높게 나타났다. 121$^{\circ}C$ 살균처리구가 10$0^{\circ}C$ 처리구보다 약간 높은 경향을 보였다.^{\circ}C$$,에서는 20시간 가열시 0.706$\mu\textrm{g}$/kg으로 가장 높게 생성된 후 서서히 감소하였다. 그러나 산값과 공액이중산값은 계속 증가하는 양상을 나타냈다. 즉 B(a)

  • PDF

A Study of air Sterilization System in Personalized Office Using Simulation (시뮬레이션을 이용한 개별사무공간의 살균공조시스템 연구)

  • Choi, Sang-Gon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.6
    • /
    • pp.353-360
    • /
    • 2010
  • Recently H1N1(swine flu) and SARS has been infected widely in the world; we have to care about germs and virus in indoor air environment. The air sterilization system investigated in this study allows occupants to turn on/off and to control the incoming air speed and direction. To predict the performance of air sterilization system without real experiment, a simulation is considered to compare and analyze the performance of the air sterilization systems in a typical office space. Multiple system parameters including volume flow rate and velocity of supply air were varied and investigated during the simulation. The investigation result shows that difference (between simulation and experiment) was about 3.5% in case of minimum air flow rate and about 0.2% in case of maximum air flow rate. The results indicate that multi-zone simulation technique can be used to predict the performance of a sterilization system in personalized office.

Experiment on the Sterilization Performance of Airborne Bacteria in Indoor Spaces using the Variation of Ozone Concentration Generated According to the Discharge Time of a Plasma Module with a Dielectric Barrier Discharge Technology (유전체 장벽방전 플라즈마 방전시간에 따른 오존 발생 농도변화의 값을 통한 실내 공간 내 부유세균 살균성능에 대한 실험)

  • Su Yeon Lee;Chang Soo Kim;Gyu Ri Kim;Jong Eon Im
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.2
    • /
    • pp.344-351
    • /
    • 2023
  • Purpose: This study aimed to evaluate the effectiveness of a dielectric barrier discharge (DBD) plasma module for sterilizing airborne bacteria in indoor spaces and measure the concentration of ozone generated during plasma discharge. Method: The DBD plasma module was installed in a 76m3 space, and air samples were collected under various discharge times to compare the reduction of airborne bacteria. Result: The results showed a significant decrease in airborne bacteria, ranging from 92.057% to 99.999%, with an average ozone concentration of 0.04 ppm, below the reference value. Conclusion: The study suggests that plasma discharge can be used as a means of preventing the spread of airborne bacteria and viruses, while ensuring safety for human exposure.

UV Immune System of Personalized Space (개별공간의 자외선 살균 시스템)

  • Jeong, Ky-Bum;Choi, Sang-Gon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.1
    • /
    • pp.63-70
    • /
    • 2009
  • The air sterilization systems are investigated experimentally in this paper. The goal is to reduce bacteria, mold and viruses in office air by using a UV sterilizer installed inside a partition panel and wall-mounted unit. These systems allow occupants to turn the system on/off and to control the incoming air speed and direction. The partition air sterilization system conditions and sterilizes the air, and then delivers the clean air into the personal task area through the partition panels, which are connected to the pressurized under-floor plenum. Room air exits through the return grills mounted on the ceiling. The wall-mounted air sterilization system sterilizes the air, and then delivers the clean air to the personal task area from the wall. In this study a full-size experimental environment is established to investigate the immunization performance of these air sterilization systems. A typical office space scale is used in this study in order to find an optimal system to achieve a sterilized healthy micro-environment. Multiple system parameters, including volume flow rate and velocity of supplied air, were regulated during the experiments. The more air contact these air sterilization systems had, the better disinfection performance. Over 90% of eradication ratios were obtained by these two air sterilization systems. The results indicate that these systems can efficiently disinfect office air contamination.

A Study on Ozonized Water Spraying System (오존무 분사장치 개발에 관한 연구)

  • Cho, Kook-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.267-270
    • /
    • 2007
  • 오존무 분사장치는 흡입구와 내에 소정의 공간이 형성된 케이스와 자동 손잡이와 $360^{\circ}$회전이 가능해 운반 및 이동이 간편한 케이스, 상기 케이스의 내부 소정 부위에 공기 흡입구로 흡입되는 공기 중에 포함된 먼지 및 습기를 제거하는 제습 장치와, 원료가스인 공기를 일정하게 제공하는 송풍기, 강력한 살균 소독기능을 지닌 오존발생기, 오존을 발생시키기 위한 고주파 펄스 전원장치, 입자경이 $3{\sim}40{\mu}m$이하의 이류체 미세 분사형 노즐, 살수통(물을 담는 용기) 및 기능 조절부(펄스전원제어, 타이머 조절, 송풍기 제어, 이류체 미세 분사형 노즐스위치 제어)로 성되어 작동하는 것으로 일반적인 가습기와는 다르다. 그리고 강력한 살균, 소독, 탈취 및 대기의 정화 기능이 있는 오존을 이용하는 동시에 기존의 방식보다 간단한 구조의 분무발생 수단을 구비함으로써 전체적으로 구성을 간단하게 하면서 대기 정화 효율을 향상시키는 장점이 있다.

  • PDF

Sterilizing and Deodorizing Effect of UV-Ray Air Cleaner for Refrigerator (자외선(紫外線) 공기(空氣) 청정기(淸淨機)의 냉장고(冷藏庫) 살균(殺菌) 탈취(脫臭) 효과(效果))

  • Chun, Jae-Kun;Lee, Yung-Jin;Kim, Kyung-Man;Lee, Hong-Won;Jang, Eu-Yung
    • Korean Journal of Food Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.174-177
    • /
    • 1993
  • Ultara violet ray air cleaner to use as the sterilization and deodorization device in refrigerator was designed and made of UV lamp and carbon block as the main components. The intensity of the lamp was $2.38\;mW/cm^2$ and reflector was installed to increase the radation. After running the device for 12 hours, 80% of the population of airborn bacteria was sterilized both at 48 and 480 liter refrigerator chambers. Ozone production caused by UV-ray reached 0.082 ppm at holding section within a few second when the device was operated at $25^{\circ}C$ and it showed 0.06 pm at $3^{\circ}C$. Deodorization effect was 2.5 times greater than that of a device made of electrical are principle at $25^{\circ}C$. New device 2 times more effectivly decreased trimethylamine and methyl mercaptan content applied as odor indicator substance in chamber at $3^{\circ}C$ than electrical arc type.

  • PDF

Establishment of self-specification and shelf-life by standardization of manufacturing process for lyophilized Tenebrio molitor larvae (동결건조 갈색거저리 유충의 제조공정 표준화에 따른 자가규격 및 유통기한 설정)

  • Chung, Mi Yeon;Lee, Jeong-Yong;Lee, Jin-Chae;Park, Kil-Su;Jeong, Jun-Pyo;Hwang, Jae-Sam;Goo, Tae-Won;Yun, Eun-Young
    • Journal of Sericultural and Entomological Science
    • /
    • v.52 no.1
    • /
    • pp.73-78
    • /
    • 2014
  • This study was carried out to establish the self-specification and shelf-life by standardization of manufacturing process for Tenebrio molitor larvae. First, standardization of manufacturing process for T. molitor was set up. Sterilization for larvae placed on a multistage shelf with intervals of about 10 cm was carried out at $115^{\circ}C$, $1kgf/cm^2$ for 10 min. After sterilization, T. molitor larvae were frozen at less than $-35^{\circ}C$ for more than 12 hrs. And then, they were dried under $-15^{\circ}C$, 0.5 torr vacuum for more than 30 hrs. Second, we decided self-specification for T. molitor larvae. Their moisture, acidity, peroxide, crude protein and crude fat level should be 5% or less, 3 mg/g or less, 30 meq/g or less, 45% or more, and 25% or more, respectively. Also, oleic acid, representative material, level was set up 11 ~ 16%. Third, we decided shelf-life by analysis of the physicochemical characteristic, sensory evaluation and microbial indicators. The final expiry date for lyophilized T. molitor larvae in PET bottle was calculated as 12 months from date of manufacture. We expect that optimal manufacturing process system, self-specification, and shelf-life proposed in this study can be used in industrial production of T. molitor as a novel food.

Effect of Mixing Elements in Line Mixer on Mixing and Flow Characteristics (혼화 및 유동특성에 미치는 라인믹서 내 혼합요소의 영향)

  • Yu, Dae-Gyeom;Lee, Kye-Bock
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.437-443
    • /
    • 2018
  • This study investigates the effect of the mixing elements on the pressure loss and mixing performance in line mixer. The high density ozone water devices mixed with gas and liquid are used in various fields such as sterilizing of group feeding facilities and water quality management at a fish farm. Due to the decrease in rainfall due to climate change, pasteurization of drinking water from ground water and surface water is extremely important. Therefore, it is intended to develop a line-mixed gas liquid mixer with a small amount of space. In this study, the effects of the number of static mixers and the types and the number of the orifice used in line mixer on the volume fraction and the pressure loss were studied by CFD simulation. The pressure drops of line mixer with orifice which curved vanes were attached to were down to more than 50 percent of that of line mixer with static mixer whereas the mixing performance of the former was similar to that of the latter.