• Title/Summary/Keyword: 고층

Search Result 1,320, Processing Time 0.026 seconds

A Study on the Economic and the Field Application Feasibility of Unit Curtain Wall Mullion Rail Lift System (유니트 커튼월 멀리온 레일 양중 시스템의 경제성 및 현장 적용 가능성에 관한 연구)

  • Jung, Ui-In;Kim, Hea-Na;Kim, Bong-Joo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.1
    • /
    • pp.41-49
    • /
    • 2021
  • This study was to solve the lift problem of the existing unit curtain wall type by using the vertical material mullion as a rail in curtain wall, which is recently used as an external finishing material for high-rise buildings. It has been shown that the application of the curtain wall mullion's rail can be quantified even at 20m/sec wind speed through the Mock-Up test. Based on the sites selected for comparison of construction methods, it was analyzed that the construction period could be shortened by 48 days, or about 20 percent. It was analyzed that the number of construction workers could be reduced by about 33 percent from the previous nine to six. Based on these results, assuming the installation of curtain wall units of 10,000㎡, it is judged that construction cost can be reduced by 80% or more.

KOMPSAT-3A Urban Classification Using Machine Learning Algorithm - Focusing on Yang-jae in Seoul - (기계학습 기법에 따른 KOMPSAT-3A 시가화 영상 분류 - 서울시 양재 지역을 중심으로 -)

  • Youn, Hyoungjin;Jeong, Jongchul
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.6_2
    • /
    • pp.1567-1577
    • /
    • 2020
  • Urban land cover classification is role in urban planning and management. So, it's important to improve classification accuracy on urban location. In this paper, machine learning model, Support Vector Machine (SVM) and Artificial Neural Network (ANN) are proposed for urban land cover classification based on high resolution satellite imagery (KOMPSAT-3A). Satellite image was trained based on 25 m rectangle grid to create training data, and training models used for classifying test area. During the validation process, we presented confusion matrix for each result with 250 Ground Truth Points (GTP). Of the four SVM kernels and the two activation functions ANN, the SVM Polynomial kernel model had the highest accuracy of 86%. In the process of comparing the SVM and ANN using GTP, the SVM model was more effective than the ANN model for KOMPSAT-3A classification. Among the four classes (building, road, vegetation, and bare-soil), building class showed the lowest classification accuracy due to the shadow caused by the high rise building.

Analysis of frequency characteristics and evaluation methods of elevator noise (승강기 소음의 주파수 특성 분석 및 평가 방법 고찰)

  • Kang, Min-Woo;Oh, Yang-Ki
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.6
    • /
    • pp.607-614
    • /
    • 2021
  • Research on elevator noise has mainly focused on the cause of its occurrence and measures to reduce it. There is still insufficient research on how to accurately measure and evaluate elevator noise. There is a measurement method established as an international standard for the measurement method, but it is also difficult to apply to high-rise apartments, and there are many cases that do not closely reflect the characteristics of elevator noise. In order to solve this problem, a study was conducted to improve the elevator noise measurement method in the current standard. In this study, the characteristics of elevator noise were closely identified. Through frequency analysis of the elevator noise and other equipment, it was verified that the elevator noise is noise with different characteristics from other equipment. Elevator noise was compared with heavy floor impact noise, which is a representative structural transmission noise, as structural transmission noise. Elevator noise was compared with heavy floor impact noise, which is a representative structural transmission noise, as structural transmission noise. The correlation between bang machine and rubber ball was found to be very high at 0.9 level. As a result, it was verified that the mid-low frequency band of the elevator noise is the main structural transmission noise and cannot be evaluated together with other equipment.

A Study on the Visualization of Urban Wind Flow by Using Thermochromic Pigment (열변색성 염료를 이용한 도심 공기 유동 시각화에 관한 연구)

  • Kim, Hong-Seok
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.11
    • /
    • pp.291-299
    • /
    • 2021
  • Recently, due to environmental problems caused by densification and high rise of urban areas, interests in air flow is increasing and appropriate shape and layout design of buildings is required. Therefore, in this study, we intend to propose an experimental method that can observe the air flow around a building using thermochromic pigment. Thermochromic pigments have limitations in observing precise temperature changes due to the characteristic that the color changes only with respect to a specific temperature, but they have the advantages of easy configuration of experimental equipment and short time required for experiments. In this study, the air flow tendencies around a building was examined by performing CFD analysis for a simple model and then compared with the thermochromic experiment results in order to review the usefulness of the proposed experimental method. As a result of the experiment, it was possible to observe the formation of separated flow and vortex region generated by buildings using the charateristics of thermochromic pigment and it was confirmed that the proposed method can be useful for buildings design and urban city planning.

Punching Shear Strength of Slab-Column Interior Connection Considering Anchorage Performance of Shear Reinforcements (전단보강재의 정착성능을 고려한 슬래브-기둥 내부접합부의 뚫림전단강도)

  • Jung, Hyung-Suk;Choi, Hyun-Ki;Chung, Joo-Hong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.2
    • /
    • pp.51-58
    • /
    • 2022
  • Flat plate slab is cost-efficient structural system widely used in high rise building, apartment and parking garages. But flat plate-column connections are so weak against punching shear failure that it may cause collapse of overall structure. In this study, spiral type shear reinforcement which increases the shear strength and ductility of the plate-column connection and has good workability was proposed. And experimental test was performed to verify the punching shear capacity of spiral type shear reinforcement. The current code does not accurately estimate the punching shear strength of slab-column connection with shear reinforcement because slab is so slender that punching failure may occurred before shear reinforcement reached yield stress. Therefore modified equation of ACI code for punching shear strength was proposed base on finite element analysis using LUSAS program, and data analysis from CEB-FIP database.

A Study on the Performance Improvement Plan of Inflowing Air Emission (유입 공기의 배출 성능 개선방안에 관한 연구)

  • Lee, Hye-Young
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.2
    • /
    • pp.241-251
    • /
    • 2022
  • Purpose: In the event of a fire in a high-rise building, if the smoke control area is not effectively protected, smoke or flames enter the stairwell, making it difficult to evacuate. When inflowing air is discharged from a closed corridor, a negative pressure is formed in the corridor, the pressure in the smoke control area becomes excessively high, and the force required to open the door during evacuation is exceeded. Also, if the air introduced into the hallway is not exhausted, the smoke may flow back into the smoke control area. This paper tried to identify the problems caused by the inflowing air and to find out how to improve the performance. Method: Using the CONTAM program, simulations were performed with the basic conditions and the modified conditions. Result: If the inflowing air was discharged from the sealed corridor, overpressure occurred in the Smoke Control Area and exceeded the opening force, and the prevent smoke backflow was insufficient in the layer where the inflowing air was not discharged. Conclusion: "Differential pressure exhaust damper" application, simultaneous opening of two exhaust dampers, and automatic window installation between corridors and outdoors improved the exhaust performance of inflowing air.

On the Initial Plans (1959) of UNESCO House in Seoul, Korea by Kuzosa Architects & Engineers (구조사건축기술연구소의 유네스코회관 초기 계획안(1959)에 관한 고찰)

  • Woo, Don-Son;Kim, Tae-Hyung;Lee, Sumin
    • Journal of architectural history
    • /
    • v.31 no.2
    • /
    • pp.35-50
    • /
    • 2022
  • This study examines the design intent and the construction background of the UNESCO House in Korea planned in the 1950s, with a focus on the initial plans of the House by Kuzosa Architects & Engineers in 1959. To this day, the House has been evaluated as a representative example of an office building in the 1960s, and an early case of introducing curtain walls in Korea. However, only its technical characteristics have been explored with less emphasis on further research data. This study attempts to demonstrate the social and cultural expectations and the demands of the construction of the House by examining the documents produced at the time and the initial plan. This study also highlights the fact that the House was the first project of the architect Pai Ki Hyung to realize high-rise reinforced concrete construction in Seoul's dense center. In the 1950s, the House was planned as a modern building with a complex of various cultural facilities and offices due to the character of activities of the Commission, and the lack of public cultural facilities in Korea. The plan of the Kuzosa Architects & Engineers was selected through a design competition held in 1959. The House was completed in 1967, which took about eight years from planning to completion with design modification in the 1960s. The initial plan submitted before the design modification shows that Pai used the vocabulary and logic of modern architecture and planned the House not as a simple office building but as a complex cultural facility.

An Analysis of Item Factors for Preliminary Survey of Job Satisfaction of General Disaster Manager in High-rise and Underground-linked Complex Buildings (초고층 및 지하연계 복합건축물 등에서 총괄재난관리자의 직무만족도 예비조사를 위한 항목요인 분석)

  • Jong Bueom Kim;Min Kyun Eun
    • Journal of Korean Society of Disaster and Security
    • /
    • v.15 no.4
    • /
    • pp.47-56
    • /
    • 2022
  • Along with high-rise buildings, complex buildings used by many unspecified people, such as various buildings and underground-linked buildings, are increasing. In particular, high-rise buildings are accompanied by a number of casualties and a lot of property damage in the event of a disaster, so reinforced integrated disaster management is necessary. The High-Rise Disaster Management Act stipulates that a general disaster manager is appointed and requires stricter safety management tasks than other buildings. Therefore, this study aims to analyze and present item factors for a preliminary survey of job satisfaction of general disaster managers through literature research and expert verification.

A Study on the Circulation Planning of Multi Shopping Mall with User Evaluation (사용자 평가를 통한 복합쇼핑몰 동선 계획 연구)

  • Kim, Ji Soo;Hwang, Yeon Sook
    • Design Convergence Study
    • /
    • v.15 no.5
    • /
    • pp.55-70
    • /
    • 2016
  • Multi shopping malls provide us new life-style nowadays with the term, malling. Multi shopping malls are consisted of selling space, entertainment space and convenience space so that arrangement and circulation planning of each facilities have large influence to users. Based on this influences, this study aims to provide basic data for multi shopping malls' circulation planning. Therefore, this study selected 6 multi shopping malls in Seoul and conducted survey that satisfaction of circulation planning of multi shopping malls. For user satisfaction investigation, we studied concept of multi shopping mall following Korean building act and selected composition and characteristics of circulation. Also, we classified the malls to size and circulation shapes for comparison of the satisfaction results. Classified types are high-rise and low-rise and they are separated to small size and big size. In addition, classified circulation shapes are categorized to net type, loop type, cyclical loop type and multi type by forms of central space and main stream of the malls.

Visible Height Based Occlusion Area Detection in True Orthophoto Generation (엄밀 정사영상 제작을 위한 가시고도 기반의 폐색영역 탐지)

  • Youn, Junhee;Kim, Gi Hong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3D
    • /
    • pp.417-422
    • /
    • 2008
  • With standard orthorectification algorithms, one can produce unacceptable structure duplication in the orthophoto due to the double projection. Because of the abrupt height differences, such structure duplication is a frequently occurred phenomenon in the dense urban area which includes multi-history buildings. Therefore, occlusion area detection especially for the urban area is a critical issue in generation of true orthophoto. This paper deals with occlusion area detection with visible height based approach from aerial imagery and LiDAR. In order to accomplish this, a grid format DSM is produced from the point clouds of LiDAR. Next, visible height based algorithm is proposed to detect the occlusion area for each camera exposure station with DSM. Finally, generation of true orthophoto is presented with DSM and previously produced occlusion maps. The proposed algorithms are applied in the Purdue campus, Indiana, USA.