• Title/Summary/Keyword: 고층구조물

Search Result 212, Processing Time 0.025 seconds

Test Result on Embedded Steel Column-to-Foundation Connection for Modular Unit Structural System (유닛 모듈러 기둥 매입형 기초 접합부에 대한 실험 연구)

  • Lee, Sang Sup;Bae, Kyu Woong;Park, Keum Sung;Hong, Sung Yub
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.6
    • /
    • pp.537-547
    • /
    • 2014
  • A steel modular unit structural system has been used increasingly for mid and high-rise buildings, since the building can be easily constructed by assembling the pre-made modular unit structures. For this structural system, each modular unit structures have to be properly connected to the foundation to transfer the axial force and the bending moment that are generated from external load to the ground. In this study, a new type of the embedded steel column-to-foundation connection was proposed, and its flexural behavior was evaluated through a series of experimental study. Five full scale specimens for the proposed connections were constructed and tested. The effect of the main parameters that affect the flexural behavior of the proposed connection, such as embedment length and shape of end plate, were studied. From the results, it was found that the flexural stiffness of the proposed connection was higher than that of the semi-rigid connection for all test specimens, and 200 mm of embedment length was proper for the given test specimens in this study.

Lightweight Concrete Fracture Energy Derived by Inverse Analysis (역해석으로 도출된 경량콘크리트의 파괴에너지 특성 분석)

  • Lee, Kyeong-Bae;Kwon, Min-Ho;Seo, Hyun-Su;Kim, Jin-Sup;Cho, Jae-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.5
    • /
    • pp.22-29
    • /
    • 2015
  • Modern structures is the tendency of being increasingly taller and larger. The concrete with large weight has the disadvantage of increasing the weight on the structure. therefore, the method of carrying out the weight saving of the concrete is required. one of such method is to use a lightweight aggregate. However, studies on structural lightweight concrete, lacking for the recognition of the lightweight concrete, so also is lacking. therefore it is necessary to study on the physical characteristic value of the lightweight concrete. In this study, in order to investigate the tensile properties of lightweight concrete, Crack mouth opening displacement (CMOD) experiments were carried out. the fracture energy of the lightweight concrete subjected to inverse analysis were derived from the CMOD experimental results.

A study on the Strength Interaction Equation of H Beams with Web Openings (유공(有孔) H형강(型鋼)보의 강도식(强度式)에 관한 연구(硏究))

  • Park, Jong Won;Jung, Jae Gil;Sin, Young Su
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.2
    • /
    • pp.177-189
    • /
    • 2001
  • It is a common practice to cut openings in the beam webs for the passage of service ducts or pipes in steel building structures. The objective of this paper is to propose a strength interaction equation of H beams with web holes based on the plastic collapse mechanism. In the development of the equation, the basic assumptions used in the previous strength equations and their limitations were investigated. Based on the investigation, a new equation which is simple and easy to understand was proposed. The reliability of the proposed method was evaluated using the test results of previous research made so far. Comparison of the ultimate strength by the proposed equation with previous test results showed that the proposed equation gives more reasonable prediction than the previous strength equations which are commonly used in practice.

  • PDF

The Accuracy Analysis of Each Test Area Short Baseline Using Satellite Navigation System (위성항법시스템을 이용한 대상지별 단기선 정확도 분석)

  • Park, Woon-Yong;Cha, Sung-Yeoul;Hong, Soon-Heon
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.10 no.1 s.19
    • /
    • pp.51-57
    • /
    • 2002
  • GPS proved to very practical in the application of geodesy and surveying such Civil Engineering, control point surveying and the deformation surveying o( structure, but the accuracy of static GPS positioning is degraded at the sites which the visible satellites of GPS are less than 4, i.e. the urban area covered with the high building and the industrial zone. Thus, the combined GPS/GLONASS system was introduced to acquire the high accuracy of static positioning by a few satellites. So the combined GPS/GLONASS system show the good results at the sites which the accuracy of positioning is degraded due to few satellites, the cutoff of signal, and multipath in the urban area.

  • PDF

Development of temperature monitoring system for bus duct (부스닥트용 온도감시 시스템 개발)

  • Kim, Dong-Wook;Nam, Suk-Hyun;Park, Sung-Ju;Huh, Sung-Su
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.15-16
    • /
    • 2006
  • 배전선로에 전력을 공급하는 방식은 일반적으로 22.9kV급 XLPE 케이블에 의한 전력공급이 주를 이루어 왔다. 한편으로 대규모 전력을 소비하는 공장 및 고층 빌딩의 전력 공급에 있어서는 일반적으로 각각 부하로의 많은 회선수의 케이블 포설을 요하는 전력케이블 보다는, 한 선로로 보다 많은 대전류를 수송하면서 부하 가까이에서 필요한 전류를 간편하게 분기해 공급받는 부스덕트 시스템이 시공 및 배전선로 관리의 간편성에 의해 점차 용도가 늘어나고 있다. 부스닥트 시스템의 대부분은 일단 시설물이 건축될 때 건축물의 상부 공간 또는 설비가 위치한 하부 바닥 구간을 통해 설치된 이후, 기타 배관, 가스관 등의 추가적인 건축 구조물과 함께 설치되어 이후 선로의 보수 진단 등이 대부분 어렵게 되어진다. 본 논문에서 소개하는 부스덕트의 온도감시 시스템은 아무리 복잡하고 협소한 설치 환경이라도 특수한 포설 공법에 의해 광화이버를 포설하고, 이를 활용하여 실시간으로 부스덕트 선로의 표면온도와 주변온도를 상시 감시함으로써, 효율적인 부스덕트 선로의 활용뿐만 아니라 과열에 의한 절연사고를 미연 방지하는 운전신뢰성과 안정성을 높이는 것이 가능하게 되었다.

  • PDF

Analysis of the Static Characteristics of High-Rise Structures With Twisted Shape (비틀어진 형상(Twisted)을 가지는 고층 구조물의 역학적 특성 분석)

  • Lee, Da-Hye;Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.20 no.4
    • /
    • pp.93-100
    • /
    • 2020
  • In this study, structural characteristics were analyzed by combining gravity load and lateral loads such as seismic loads through static analysis of example structures, and the static characteristics of the twisted structure according to the plane rotation angle were also analyzed. Example structures were selected as regular structure, and twisted structures; 1.0, 2.0, and 3.0 degree angle of rotation per story, and static analysis was performed by the load combination case 1 and case 2. As a result the story drift ratio of the twisted-shaped structure also increased as the plane rotation angle per story increased. The eccentricity according to the load combination was the highest in the lower stories of all analysis models, and the eccentricity was found to be larger as the rotation angle decreased. The twisted-shaped structure was more responsible for the bending moment of the column than the regular structure, and the vertical member axial force of all analysis models was almost similar.

Dynamic Response Analysis of Twisted High-Rise Structures by Plane Rotation Angle (비틀어진 형상(Twisted) 고층 구조물의 평면 회전 각도별 동적 응답 분석)

  • Lee, Da-Hye;Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.21 no.1
    • /
    • pp.105-112
    • /
    • 2021
  • In this paper, the dynamic response was analyzed by performing linear dynamic analysis using historic earthquake loads on twisted-shaped structures and fixed structure among free-form high-rise structures with atypical elevation shape following prior studies. In addition, the dynamic characteristics of the analysis models according to the plane rotation angle of the twisted structure were compared and analyzed. As a result of the analysis, as the plane rotation angle of the twisted structure increased, the interlayer deformation rate increased in the high-rise part of 50th floors or more. The story shear force and the story absolute acceleration were similar in the entire structure. In the case of the story shear force, the response of the twisted shape model was rather reduced in the middle part. As a result of analyzing the dynamic response, the vulnerable layer where the response amplification of the twisted structure occurs was found to be 31st story.

The Response Characteristics of Push-over and Nonlinear Time History Analysis with Variations in the Upper Stories of the Mixed Building Structure (복합구조물의 상부층수 변화에 따른 탄소성 정적 및 동적 응답특성)

  • 강병두;전대한;김재웅
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.5
    • /
    • pp.73-83
    • /
    • 2001
  • The mass and stiffness of upper wall-lower frame system(mixed building structures) change sharply at transfer floor due to different structural system in upper and lower part. These mixed building structures generally show the stiffness, weight or geometric vertical irregularities. The purpose of this study is to investigate the response characteristics of these structures by push-over analysis and nonlinear time history analysis. For four types of analysed models, only the variation of upper wall stories was considered. The conclusions of this study are following; (1) In the push-over analysis, yielding hinges in beams and columns of lower frame occurred at the base shear of similar magnitude in all models. But as the number of stories of upper wall increases, yielding hinges at ends of coupling beams were observed in the small magnitude of base shear. (2) In the nonlinear time history analysis, yielding of lower frame occurred at beams with as small ground acceleration as 55gal, and in upper walls yielding was concentrated on coupling beams and shear walls near the transfer floor. (3) As the number of stories of upper walls decreases, the story stiffness of the lower frames decreased relatively and the occurrence of soft stories in the lower frame was observed.

  • PDF

Experiments on Flow Characteristics of Asphalt Seal Composite Waterproofing Method for Underground Concrete Structure Exterior Wall Waterproofing (지하 콘크리트 구조물 외벽 방수용 아스팔트 씰재 복합방수 공법의 흘러내림 특성에 관한 실험)

  • Ko, Sang-Ung;Kim, Kyoung-Hoon;Kim, Young-Sam;Shin, Hong-Chul;Kim, Jin-Man
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.4
    • /
    • pp.297-303
    • /
    • 2018
  • With the changing trend of the building construction to high rising and large scaling, the underground structure has been increased, and its usage also increased and variety. Hence, to protect the underground structure against underground water, various water proofing methods has been developed. Among the many water proofing methods, the combined water proofing method using both asphalt seal and sheet has been widely used to secure the sufficient performance and decrease the construction failure. However, during the summer period of extremely high temperature conditions, the asphalt sealing materials were separated and leaked into the structure. Therefore, the aim of the research is to provide the quality standard of asphalt sealing material based on the various temperature changes depending on seasons. According to the experimental results, the temperature of the sealing materials applied on the slab was increased up to $54^{\circ}C$ which was $3^{\circ}C$ higher than the structure temperature of $51^{\circ}C$. Based on the melting test for asphalt sealing materials applied on the outside wall of the structure, in the case of water-dispersing typed materials showed significant melting down due to its slow evaporation and low viscosity. Furthermore, from the accelerated test conducted indoor conditions, a solvent-type and water-dispersing typed materials showed significant melting down due to their low viscosity and melting point in ambient conditions. Based on these results, viscosity and melting point are found as the important factors on asphalt sealing materials' quality, and it is necessary to designate the quantitative level of the viscosity and melting point for quality control.

Ambient Vibration Testing and System Identification for Tall Buildings (고층건물의 자연 진동실험 및 시스템판별)

  • Cho, Soon-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.23-33
    • /
    • 2012
  • Dynamic response measurements from natural excitation were carried out for three 18-story office buildings to determine their inherent properties. The beam-column frame system was adopted as a typical structural form, but a core wall was added to resist the lateral force more effectively, resulting in a mixed configuration. To extract modal parameters such as natural frequencies, mode shapes and damping ratios from a series of vibration records at each floor, the most advanced operational system identification methods based on frequency- and time-domain like FDD, pLSCF and SSI were applied. Extracted frequencies and mode shapes from the different identification methods showed a greater consistency for three buildings, however the three lower frequencies extracted were 1.2 to 1.7 times as stiff as those obtained using the initial FE models. Comparing the extracted fundamental periods with those estimated from the code equations and FE analysis, the FE analysis results showed the most flexible behavior, and the most simple equation that considers the building height as the only parameter correlated fairly well with test results. It is recognized that such a discrepancy arises from the fact that the present tests exclude the stiffness decreasing factors like concrete cracking, while the FE models ignore the stiffness increasing factors, such as the contribution of non-structural elements and the actual material properties used.