• Title/Summary/Keyword: 고정세

Search Result 748, Processing Time 0.029 seconds

TREATMENT OF THE IMPACTED LOWER SECOND MOLARS (매복된 하악 제2대구치 맹출유도의 치험례)

  • Hahn, Soo-Kyoung;Kim, Jung-Wook;Lee, Sang-Hoon;Kim, Chong-Chul;Hahn, Se-Hyun;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.1
    • /
    • pp.41-45
    • /
    • 2004
  • In the normal growth and development of the mandible, the molar tooth buds distal to the first permanent molar have a mesial inclination. This inclination is usually self-correcting, but, unfortunately, this self-correction does not always occur. The first case is about, 14-year-old female patient with familial history of lower second molar impaction. Her lower second molars were both impacted, and she was treated with sectional wires and open-coil springs. The second case, 14-year-old male, we treated his impacted #47 with Halterman appliance. The third case, 11-year-old male, his both mandibular second molars were impacted during full-fixed orthodontic treatment. They were treated with brass wire, sectional wire and open-coil spring.

  • PDF

Adsorption of Ni(II), Co(II), and Mg(II) from Sulfuric Acid Solution by Diphonix Resin for the Utilization of Laterite Ore (라테라이트광 활용을 위한 황산용액에서 Diphonix 수지의 니켈, 코발트, 마그네슘 흡착)

  • Lee, Man-Seung;Kim, Sang-Bae;Chae, Jong-Gwee
    • Journal of the Mineralogical Society of Korea
    • /
    • v.23 no.3
    • /
    • pp.183-189
    • /
    • 2010
  • It is of importance to separate Ni(II) and Co(II) from Mg(II) in solution which was leached from nickel laterite ore. In order to investigate the possibility of separating Ni(II) and Co(II) from Mg(II), adsorption behavior of the three metals from individual and mixed sulfate solutions was investigated by using Diphonix resin. The concentration of each metal in solution was fixed at 100 ppm and the pH of the sulfuric acid solution was changed from 5 to 7. At ambient temperature, the adsorption behavior of the three metal ions followed Langmuir adsorption isotherm. The loading capacity of Diphonix resin for the three metal ions was obtained from the Langmuir isotherm. Since adsorption behavior of the three metal ions from the mixed solution was similar to each other, it was found to be difficult to separate Ni(II) and Co(II) from Mg(II) by using Diphonix resin.

An Experimental Investigation on the Hydrodynamic Characteristics of Submerged Artificial Seabed System in Regular Waves (중층계류식 인공해저시스템의 파랑중 운동특성에 관한 실험적 연구)

  • Yoon Sang-Joon;Yang Chan-Kyu;Kim Hyeon-Ju;Kim Heon-Tae
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.5 no.2
    • /
    • pp.19-27
    • /
    • 2002
  • This paper deals with the experimental investigation on the hydrodynamic behavior of the submerged artificial seabed system in regular waves. This system can function as a basis of seaweed forest which will cultivate coastal fishing ground and enhance coastal productivity. The experiment was conducted with the submerged rectangular plates of different length and depth in 2-D wave flume of KRISO/KORDI. The wave exciting forces, mooring line tension and 2-D motion response are measured and analyzed to figure out the design strategy.

  • PDF

Arthroscopic Cannulated Screw Fixation of Avulsion Fracture of the Intercondylar Eminence of the Tibia in a Child -A Case Report- (소아에서 발생한 전방 십자인대 견열 골절에서 유관 나사못을 이용한 관절경적 정복술 -증례보고-)

  • Moon, Kyu Pill;Kim, Kyung Taek;Kang, Min Soo;Park, Won Ro
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.11 no.1
    • /
    • pp.62-65
    • /
    • 2012
  • Avulsion fractures of the intercondylar eminence of the tibia are uncommon. This kind of fracture is most commonly found in adolescents, with an increasing incidence for those involved in competitive athletics. Recently, an arthroscopic procedure is preferred to reduce the operation-related morbidity. Screws, K-wires, Suture anchor have been described as fixation devices. Cannulated screw fixation is a simple method, but this instrument has the risk of causing damage to the growth plate. The authors report good results using cannulated screw in arthroscopic treatment for pediatric anterior cruciate ligament avulsion fracture.

  • PDF

Location Estimation based on Edge Weights in Wireless Sensor Networks (무선 센서 네트워크에서 에지 가중치를 이용하여 위치를 측정하는 기법)

  • Kim Sook-Yeon;Kwon Oh-Heum
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.10A
    • /
    • pp.938-948
    • /
    • 2005
  • Localization in wireless sensor networks is to determine the positions of all nodes based on the Down positions of several nodes. Much previous work for localization use multilateration or triangulation based on measurement of angles or distances to the fixed nodes. In this paper, we propose a new centralized algorithm for localization using weights of adjacent nodes. The algorithm, having the advantage of simplicity, shows that the localization problem can be formulated to a linear matrix equalities. We mathematically show that the equalities have a unique solution. The unique solution indicates the locations of unknown nodes are capable of being uniquely determined. Three kinds of weights proposed for practical use are compared in simulation analysis.

Free Vibrations of Clamped Circular Arches with Linear Variable Cross-Section (1차원 변화단면을 갖는 양단고정 원호아치의 자유진동 해석)

  • Lee, Byoung Koo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.9 no.4
    • /
    • pp.1-8
    • /
    • 1989
  • The main purpose of the present paper is to present both the fundamental frequency and some higher free vibration frequencies for circular arches with variable section, in which rotatory inertia is included. The differential equations are derived for the in-plan free vibration of elastic circular arches with variable section. These equations were solved numerically for the linear variable circular cross-section with clamped-clamped end constraint. As the numerical results, the four lowest nondimensional natural frequencies presented as functions of the nondimensional system parameters : the end moment of inertia to crown moment of inertia ratio, the slenderness ratio, and the opening angle. The effect of rotatory inertia on the nondimensional natural frequency is also reported.

  • PDF

Nonunion of Tibial Eminence Fracture in Child - 2 cases Report - (소아 경골 극 골절의 불유합 - 2예 보고 -)

  • Hur, Yoon-Moo;Chung, Whan-Yong;Kim, Sang-Bum;Kim, Sung-Hun;Rhu, Seung-Reol
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.2
    • /
    • pp.192-198
    • /
    • 2006
  • The general consensus is that tibial eminence fractures have an excellent prognosis. But symptomatic nonunions requiring reduction and grafting have been reported. This report presents two cases of nonunion after tibial eminence fracture in eight years old boys which were treated with arthroscopy-guided reattachment and internal fixation and obtained good outcome.

  • PDF

Proximal Symphalangism and Congenital Stapes Fixation (기부지절유합증을 동반한 선천성등골고정증)

  • 이철희;박영원;김종선;노관택
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.41.1-41
    • /
    • 1981
  • The combination of congenital stapes fixation and proximal symphalangism has been described in several kindreds. It exhibits autosomal dominant inheritance. A patient, 11-year-old female, visited department of otolaryngology of SNUH in December, 1980. Her complaint was bilateral hearing loss since birth. Physical examination revealed fusion of proximal interphalangeal joints of both 4th and 5th fingers. Tympanic membrane was normal. Temporal bone X-ray was normal. Pure tone audiogram revealed about 60 dB conductive loss with horizontal curve. On exploratory tympanotomy of right side, bony fixation of stapedial footplate was found. So, stapedectomy with connective tissue wire prosthesis was performed. As a result, marked improvement of hearing was obtained with 5 dB A-B gap on operated side.

  • PDF

A calibration algorism for the bias of sensor axis in pedestrian dead reckoning system (보행자 관성 항법시스템에서의 센서 축 편향 보정 알고리즘)

  • Kim, Yun-Su;Park, Gun-Gu;Jo, Chan-Woong;Kim, Han-Bin;Lee, Chae-Woo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.10a
    • /
    • pp.493-495
    • /
    • 2015
  • PDR은 일반적으로 IMU센서로 부터의 가속도와 각속도를 측정하여 보행자의 위치를 추적하는 시스템이다. IMU센서로부터 측정된 가속도와 각속도 값은 센서를 기준으로 하기 때문에 보행자가 인지하는 고정 좌표계와는 차이가 있다. 이를 해결하기 위해 회전행렬을 사용하며 이후 계속해서 측정되는 각속도를 통해 회전행렬을 업데이트 한다. 업데이트된 회전행렬을 통해 좌표계를 환산하고 환산된 좌표계의 가속도 값으로부터 보행자는 고정좌표계 기준으로 위치 추적이 가능하다. 하지만 회전행렬을 업데이트 하는 과정에서 센서의 세 축이 이상적으로 수직이 아니라면 업데이트 과정에서 각속도의 오차가 누적되고 이는 좌표계를 환산에 영향을 끼쳐 위치 및 속도 추적 정확성을 낮춘다. 물리적인 Bias가 PDR 시스템에 누적오차를 발생시킨다. 이에 제안하는 센서 축 편향 보정 알고리즘은 IMU 센서의 물리적 축 오차를 보정해주어 더 정확한 위치 추적을 가능하게 한다. 또한 Matlab을 통해 데이터를 분석하고 알고리즘의 필요성을 보인다.

Automated reduced thermo-mathematical model generation method for satellite considering temperature tolerance and fixed nodes (온도 허용오차와 고정 노드를 고려한 자동화된 위성 축소 열모델 생성 방법)

  • Jimin Nam
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.2
    • /
    • pp.9-15
    • /
    • 2023
  • The task of generating a reduced thermal model of a satellite must be performed at least once in a satellite project to shorten the time of orbital thermal analysis and perform thermal analysis coupled to a launch vehicle. Although there are various methods for generating a reduced thermal model, an intuitive and convenient iso-thermal mesh generation method is used the most widely in practice. However, there is still a lack of research on automation of the isothermal mesh generation method. In this paper, we proposed an automated generation method of satellite reduced thermo-mathematical model based on the isothermal mesh generation method considering temperature tolerance and fixed nodes. The proposed method was validated using three different temperature tolerance cases. The average temperature difference satisfied the guidelines of ECSS.