• Title/Summary/Keyword: 고자장

Search Result 158, Processing Time 0.028 seconds

Analysis of $^1H$ MR Spectroscopy of parietal white matter material Phantom (두정부 백질 물질을 이용한 수소 자기 공명 분광 분석)

  • Lee, Jae-Yeong;Lim, Cheong-Hwan;Kim, Myeong-Soo
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.57-61
    • /
    • 2003
  • The purpose of this study is to compare both 1.5T and 4.7T in Praietal White matter material Phantom using the same methodology at both field strengths. Data at both field strengths are compared in terms of $T_2$ relaxation times, line widths and SNRs MR imaging and $^1H$ MR spectroscopy were performed on GE 1.5T SIGNA system and Broker Biospec 4.7T/30 MRI/MRS system. After phantom axial scan $^1H$ MRS was obtained from T2 weighted image by 3-dimensional localization technique(PRESS : Point RE solved spectroscopy Sequence) this phantom is composed of an aqueous solution 36.7 mmol/L of NAA, 25.0 mmol/L of Cr, 6.3 mmol/L of choline chloride, 30.0 mmol/L or Glu, and 22.5 mmol/L of MI(adjusted to a pH of 7,15 in a phosphate buffet). Data processed using software developed inhouse. At 1.5T, T2 relaxation times for Cho, Cr, and NAA were $0.41{\pm}0.07,\;0.26{\pm}0.04,\;0.46{\pm}0.07$ while at 4.7T they were $0.17{\pm}0.03,\;0.14{\pm}0.05,\;0.20{\pm}0.03$ respectively. At 1.5T, line widths for water, Cho, Cr and NAA were $2.9{\pm}0.7,\;1.6{\pm}0.7,\;1.7{\pm}0.8,\;2.2{\pm}0.02Hz$ while at 4.7T they were $5.2{\pm}1.1,\;4.6{\pm}1.9,\;4.01{\pm}1.8,\;4.8{\pm}1.9Hz$ respectively. It can be seen that $T_2$ relaxation times were significantly shorter at 4.7 compared to 1.5T and that the line widths were also broader. The average SNRs for NAA for subjects at short and long TEs were $23.5{\pm}11.3$ at TE=20 msec ; $15.4{\pm}7.7$ at TE=272 msec at 1.5T and $40{\pm}8.3$ and $17{\pm}3.5$ respectively at 4.7T higher field strength is superior because of improved sensitivity and chemical shift dispersion. However these improvements are partially offset by increased line widths and decrease $T_2$ relaxation times, which act to reduce both sensitivity and resolution. In our experiments with the equipment available to us, 4.7T proton spectra at short TEs exhibit moderately improved sensitivity compared to 1.5T.

  • PDF

Research on Mobile Wheelchair Lift Design (이동식 휠체어 리프트 디자인 연구)

  • 이명기
    • Archives of design research
    • /
    • v.15 no.4
    • /
    • pp.275-284
    • /
    • 2002
  • To improve the social and economic position of the disabled people and secure their human rights, an integrated society should be buill. To build such a society, an adequate access should be provided to the movement or in using buildings or facilities. The inconveniences from social life on the part of the disabled people might not result from their impairment or disability, but from physical and social barriers in the environment surrounding them. Therefore, it is necessary to reconstruct entire systems of the society as a disabled people-friendly structure in order to remove those barriers, make them stand their own feet in our communities and freely participate in the social activities. This will eventually lead to build a society in which all people including the disabled people can use those facilities in a more convenient way. It is almost impossible for the disabled people to safely and conveniently access to and use facilities and equipments and freely move to their desired places, without any help from others in Korea. Even though, there are currently many disabled people-related convenience facilities, they have been independently built without a connection with other facilities and buildings, thus not greatly useful. Even when convenience facilities have been built, mostly they are superficially set up; therefore, in many cases, the disabled peOple cannot use those facilities. In this. research, I tried a new concept of mobile wheelchair lift design, which the disabled people can operate without restrictions, when using the public facilities. The key to this research was to develop the existing import-oriented simple functional products to a new system with functional safety and high quality orientation. Also, this research aimed at bringing an. import substitution effect, as well as preempting the mobile wheelchair lift market by advancing into overseas markets through application of new image designs in the field of disabled people aid equipments.

  • PDF

Susceptibility-Contrast-Enhanced MR Venography of Cat Brain Using Tailored RF Pulse at High Magnetic Field of 4.7 Tesla Superconducting Magnet (4.7T 고자장 초전도 자석에서 Tailored RF를 이용한 고양이 뇌의 자화율 강조영상법에 의한 자기공명혈관 조영술)

  • Moon, Chi-Woong;Kim, Sang-Tae;Lee, Dae-Geun;Im, Tae-Hwan;No, Yong-Man;Cho, Jang-Hee;Lee, Yoon
    • Progress in Medical Physics
    • /
    • v.5 no.1
    • /
    • pp.55-66
    • /
    • 1994
  • After proving home-made imaging pulse sequences including tailored RF pulse by phantom, susceptibility-contrast-enhanced MR venograms of cat brain were obtained using tailored RF gradient-echo(TRGE) method. Sagittal MR imaging of the cat brain obtained by TRGE technique shows several veins, for example, dorsal sagittal sinus, straight sinus, vein of corpus callosum and internal cerebral vein, etc., compared with cats anatomical figure. Tailored RF waveform was generated by PASCAL language in ASPECT 3000 computer(Switzland, Bruker). Rectangular-shaped slice profile with bi-linear ramp function as phase distribution in the slice, at which maximum value was 2$\pi$, was fourier transformed to make tailored RF pulse. Experimental MR imaging parameters were TR/TE=205/10 msec, slice thickness TH=7mm, maxtrix size=256$\times$256, in-plane resolution=0.62$\times$0.31mm$^2$, and field of view(FOV)=8cm for both conventional gradient-echo(GE) imaging and TRGE imaging techniques.

  • PDF

Development of Solenoid RF Coil for Animal Imaging in 3T High Magnetic Field MRI (고자장 3T MRI 장비에서 동물영상을 위한 솔레노이드 RF코일 개발)

  • Lee, Hong-Seok;Woo, Dong-Cheol;Min, Kwang-Hong;Kim, Yong-Kwon;Lee, Heung-Kyu;Choe, Bo-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.1
    • /
    • pp.20-26
    • /
    • 2007
  • Purpose : The purpose of the present study was to develop and optimize solenoid coil for animal- model in 3 T MRI system and investigate and compare with the birdcage coil concerning the image quality with the various parameters such as SNR and Q-factor. Materials and Methods : Solenoid coil for animal-model was made on the acryl structure (diameter 4 cm, length 10 cm) 3 times-winding cooper tape of width 2 cm, thickness 0.05 cm and length 10 cm with 2 cm interval between winded tapes. Capacitors from 2 pF to 100 pF were used, and the solenoid coil was designed for receiver only coil. Results : SNR of the developed solenoid was 985 in CuSO4 0.7 g/L and 995 in rat experiment. Q-factor was 84-89 in unloaded condition and 203-206 in loaded condition. Conclusion : The resolution of the image obtained from solenoid was relatively higher than that of the conventional birdcage coil. In addition, the homogeneity of RF field by coil simulation was significantly excellent. The present study demonstrated that the solenoid coil could be useful to obtain small animal images with better contrast, resolution, visibility than images from birdcage.

  • PDF

핵융합용 초전도선재의 크롬도금기술

  • Park, Pyeong-Ryeol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2012.11a
    • /
    • pp.32-32
    • /
    • 2012
  • 화석연료의 남용으로 지구 온난화가 심화되어 환경과 생태계변화가 가속화되고 있고, 급속한 산업의 발달과 인류 삶의 질 향상에 따른 에너지 수요가 급증하고 있는 실정에 있으며, 일본 후쿠시마 원전사태로 원자력 에너지의 위험성으로 지구 인류환경은 심각한 국면을 맞이 하고 있어 대체 에너지의 하나로 핵융합 에너지 필요성이 증대되고 있다. 핵융합 에너지 연구 개발은 우리나라에서 KSTAR가 1997년부터 건설하기 시작하여 지난 2007년에 완공되어 지금 운용 중에 있고, 국제적으로 미국, EU, 러시아, 중국, 한국, 일본 인도가 참여하는 ITER 국제 공동프로젝트가 2004년에 건설을 시작하여 프랑스 카다라쉬에 실증 플란트를 건설 중에 있다. 이러한 핵융합 반응을 위해서는 10e-7이상의 높은 진공과 1억$^{\circ}C$ 이상에서 중수소와 삼중수소가 반응하여 발생하는 플라즈마를 제어 할 필요가 있으며, 초고온의 핵융합 플라즈마를 가두고 가동시키기 위해서는 약 12Tesla이상의 고자장 마그넷이 필요하다. 현재 ITER 실증 플란트에 사용되는 고자장 마그넷은 TF (Toroidal Field)코일과 CS (Central Field)코일에 Nb3Sn 초전도선재가 핵심부품으로 사용되고 있으며 ITER프로젝트에서는 약 850톤의 Nb3Sn 초전도선재가 사용될 전망이다. 그 중에서 일본 25%, EU, 러시아와 한국이 각각 20%, 중국7%, 미국8% 할당되어 참여국 대부분은 초전도선재를 전략적으로 공급하고 있다. 초전도 선재의 크롬도금은 1~2 마이크로미터 이하의 균일하고 얇은 도금 두께와 밀착성이 우수한 품질이 요구된다. 일반적으로 크롬도금은 산업현장에서 컨베이어 벨트 방식으로 장식이나, 내식성 및 내마모성의 특성을 필요로 할 때 사용되고 있으나, 선재에 크롬도금을 릴투릴(Reel to Reel) 방식으로 적용되는 경우는 세계적으로 아주 드물다. 핵융합 마그넷의 CICC(Conduct In Cable Conduit)도체를 만들기 위해서는 초전도선재를 이용, 3(Sc 2+OFC 1)$^*3^*5^*5^*6$형태로 연선과 케이블링을 하게 되며, 초전도 선재를 연선하고 케이블링을 할 때 크롬 도금층이 박리될 가능성이 있어 크롬도금 방법과 프로세스를 특별히 고안할 필요가 있다. ITER핵융합로 마그넷의 TF코일은 높이 14m, 폭 9m 최대자장 12Tesla, 최대전류 68kA, CICC도체 직경이 40mm로서 그 초전도 조관/도체 내부에 0.82mm 직경의 Nb3Sn 초전도 선재가 약 1350가닥으로 연선과 케이블링으로 구성되어 있다. ITER 핵융합 마그넷용 초전도 선재의 크롬도금은 마그넷 권선 후 Nb3Sn 초전도물질을 형성하기 위해서 $650^{\circ}C$에서 500시간 열처리를 실시하며 열처리 시 초전도 선재의 소선들 사이에 발생할 수 있는 소착을 방지하고, 초전도 선재에서 발생하는 AC loss를 감소시키며, Quench시 발생되는 열을 쉽게 확산시킴으로써, 초전도 마그넷의 열적 안정성(Thermal Stability) 향상과 필요에 따라서 소선간 통전울 가능하게 한다. 고려제강의 자회사인 케이에이티는 크롬도금 밀착성이 우수하고 도금두께 0.1마이크로 미터 이내 제어가 가능한 얇고 균일한 도금품질을 개발하여 한국형 핵융합 실험로인 KSTAR에 65톤 전량 공급하였고, 크롬 도금된 무산소동 선재 32톤과 초전도 선재 93톤을 전량 ITER 프로젝트에 공급하고 있으며, 2013년도 상반기에는 공급을 마무리할 예정이다.

  • PDF

Comparison and Optimization of Parallel-Transmission RF Coil Elements for 3.0 T Body MRI (3.0 T MRI를 위한 병렬전송 고주파 코일 구조 비교와 최적화)

  • Oh, Chang-Hyun;Lee, Heung-K.;Ryu, Yeun-Chul;Hyun, Jung-Ho;Choi, Hyuk-Jin
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.4 s.316
    • /
    • pp.55-60
    • /
    • 2007
  • In high field (> 3 T) MR imaging, the magnetic field inhomogeneity in the target object increases due to the nonuniform electro-magnetic characteristics of the relatively high RF frequency. Especially in the body imaging, the effect causes more serious problems resulting in locally high SAR(Specific Absorption Ratio). In this paper, we propose an optimized parallel-transmission RF coil and show the utility of the coil by FDTD simulations to overcome the unwanted effects. Three types of TX coil elements are tested to maximize the efficiency and their driving patterns(amplitude and phase) optimized to have adequate field homogeneity, proper SAR level, and sufficient field strength. For the proposed coil element of $25cm{\times}8cm$ loop structure with 12 channels for a 3.0 T body coil, the field non-uniformity of more than 70% without optimization was reduced to about 26 % after the optimization of driving patterns. The experimental as well as simulation results show that the proposed parallel driving scheme is clinically useful for (ultra) high field MRI.

Effect of Pulse Magnetic Field Stimulus on Blood Flow using Digital Infrared Thermal Imaging (체열진단을 통한 펄스자기장 자극기의 혈류개선효과 고찰)

  • Lee, Hyun-Sook
    • Journal of the Korean Magnetics Society
    • /
    • v.21 no.5
    • /
    • pp.180-184
    • /
    • 2011
  • The changes in the blood flow in the peripheral vascular system under strong pulsed magnetic fields (pMF) were studied by digital infrared thermal imaging (DITI). After pMF stimulus temperatures in stimulated area were commonly increased in both groups of age and gender. In order to reduce heat generated from coil in pMF stimulus system plastic moldings were fabricated, so that certain distance was kept between stimulus system and the skin and to prevent direct contact to the skin. It is believed that skin temperature is increased by internal electromagnetic energy stimulated the peripheral vascular system by non-contact method.

A study for the customers′cognition and tendency of usage of Electronic Commerce (전자상거래에 대한 소비자의 인식도 및 이용 행태에 관한 연구)

  • 장경수
    • The Journal of Information Technology
    • /
    • v.3 no.1
    • /
    • pp.99-115
    • /
    • 2000
  • This study shows up its objectibe in probiding enterprises which are intending to join the Electronic Commerce in the near future and existing enterprises with useful information basis for proper establishment of proper direction for marketing by the way of researching the characteristics of customers who utilize Electronic Commerce for the promotion of domestic Electronic Commerce.

  • PDF

비축대칭 소재에서 내부가 원형인 튜브의후방압출 해석

  • 양동열;배원병;김동권
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1992.04a
    • /
    • pp.74-78
    • /
    • 1992
  • 외부가 비축대칭인 튜브의 수방압출은 자동차와 항공기등의 복잡한 부품을 만드는데 많이 사용된다. 이런 후방압출 제품의 변형 상태는 저자들의 논문에서 이미 밝힌 바와 같이 복잡하다. 그래서, 외부가 비출대칭인 튜브형상의 후방압출은 근래에 와서 연구되었다. 본 연구에서는 저자들의 논문 에서 제시된 동적가용속도장을 수정하여 비축대칭인 소재에서 내부가 원형인 튜브의 후방압출의 최종 단계를 해석하 고자 한다. 해석의 적용예로서는 정다각형 소재와 모서리가 둥근 직사각형(rounded rectangle)소재를 택하였다 제시된 속도장으로부터 단면 감소율과 형상비(aspect ratio)에 대하여 압출 하중과 압출된 소재의 평균 높이가 결정된다. 이론적인 결과와 비교하기 위하여 퓰림처리된 AIST-2024 알루미늄 소재로 실험하였다.

국내 소매시장의 국제화 패턴과 기업의 대응방안

  • 김인호
    • Distribution Business Review
    • /
    • no.2
    • /
    • pp.93-104
    • /
    • 2002
  • Wal-Mart, Carrfour, Makro, Tesco, Costco... 언뜻 보기에는 세계적 유통업체의 순위를 나열한 것 같지만, 실은 국내 영업을 통해 이미 친숙해진 브랜드들이다. 국제화가 기업의 시장확장 전략의 하나라고는 하지만, 5-6년 새에 국내 유통 시장이 이러한 세계적 업체들의 각축장이 되었다는 사실은 여러 가지를 의미한다. 논의의 포커스는 먼저 이들 업체들이 진입하기 위한 충분 조건 즉, 국내 시장의 매력도에 맞춰질 수도 있고, 또 다른 시각에서는 왜 이러한 업체들이 시장확장을 해야만 했는가의 관점, 즉 필요조건에 포인트를 둘 수도 있다. 실제로 지금까지 진행된 소매 기업의 국제화 전개에 대한 논의는 대부분이 이와 같은 범주에서 양자를 모두 다루는 형태로 이루어졌다. 그러나, 국내 소매시장이 어떻게 국제화의 길을 걷게 되었는가를 살펴보는 본고는 후자인 필요조건 쪽 논의에 초점을 맞추고자한다.(중략)

  • PDF