• Title/Summary/Keyword: 고유치 감도

Search Result 26, Processing Time 0.02 seconds

Identification of Optimum Sites for Power System Controller using Normal Forms of Vector Field (벡터계 정규 형식을 이용한 전력시스템 제어기 설치 위치 선정)

  • 장길수;이인수;권세혁
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.4
    • /
    • pp.227-233
    • /
    • 2004
  • In stressed power system due to the presence of increased nonlinearity and the existence of nonlinear modal interactions. there exist some limitations to the use of conventional linear system theory to identify the optimum sites for a controller. This paper suggests an approach based on the method of normal forms to identify the optimum sites for controllers with incorporating the nonlinear interaction . In this paper, nonlinear participation factors and coupling factors are proposed as measures of the nonlinear interactions, and identification procedure of optimum sites for a controller is also proposed. The proposed procedure is applied to the 10-generator New England System and the KEPCO System in the year of 2010, and the results illustrate its capabilities.

Identification of Optimum Sites for Power System Controller using Normal Forms of Vector Field (벡터계 정규 형식을 이용한 전력시스템 제어기 설치 위치 선정)

  • 장길수;이인수;권세혁
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.4
    • /
    • pp.227-227
    • /
    • 2004
  • In stressed power system due to the presence of increased nonlinearity and the existence of nonlinear modal interactions. there exist some limitations to the use of conventional linear system theory to identify the optimum sites for a controller. This paper suggests an approach based on the method of normal forms to identify the optimum sites for controllers with incorporating the nonlinear interaction . In this paper, nonlinear participation factors and coupling factors are proposed as measures of the nonlinear interactions, and identification procedure of optimum sites for a controller is also proposed. The proposed procedure is applied to the 10-generator New England System and the KEPCO System in the year of 2010, and the results illustrate its capabilities.

Low Frequency Squeal Noise Reduction using Mode Participation Factor in Complex Eigenvalue Analysis (복소고유치해석에서 모드기여도 인자를 이용한 저주파 스퀼소음 저감)

  • Park, Jeong Min;Kim, Hyun Soo;Yoon, Moon Young;Boo, Kwang Seok;Kim, Heung Seob
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.3
    • /
    • pp.325-331
    • /
    • 2013
  • In this study, a complex eigenvalue analysis is implemented to verify the unstable mode of a brake system using ABAQUS software. The component participation factors and component modal participation factors are used to analyze the total contributions from each component and each component mode to a particular unstable system mode. This study shows that the 1.4-kHz unstable system mode comes from mode coupling between the 2nd nodal diametric mode and 3rd lateral axial mode (LAM) in the baseline model. A sensitivity analysis with a linking index is performed to prevent the mode coupling of the component modes. This linking index analysis shows the optimum mass loading position to move away the natural frequency of the 3rd LAM, which contributes to the unstable mode. Finally, a complex eigenvalue analysis is implemented with mass loading in the tie bar position, and no unstable system mode is generated in the low-frequency range (below 2 kHz).

Eigenvalue Sensitivity Calculation with respect to Controller Parameters in Multimachine Power Systems (다기계통의 제어기정수에 대한 고유치감도계산)

  • Kwon, Sae-Hyuk;Rho, Kyu-Min
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.54-56
    • /
    • 1993
  • A systematic procedure for determining the elements of system state matrix is suggested. The interrelation of submatrices of the system matrix is investigated. Each element or each block can be represented in algebraic form. These results can be applied in the eigenvalue sensitivity analysis with respect to the changes in controller parameters.

  • PDF

Eigenvalue Sensitivity Analysis of Discrete Power Systems Including Generator Controllers and TCSC (발전기 제어장치와 TCSC를 포함하는 이산 전력시스템의 고유치 감도해석)

  • Kim, Deok-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.193-200
    • /
    • 2010
  • In this paper, the eigenvalue sensitivity analysis is calculated in the power system which is including both generator controllers such as Exciter, PSS and thyristor controlled FACTS devices in transmission lines such as TCSC. Exciter and PSS are continuously operating controllers but TCSC has a switching device which operates non-continuously. To analyze both continuous and non-continuous operating equipments, the RCF method one of the numerical analysis method in discrete time domain is applied using discrete models of the power system. Also the eigenvalue sensitivity calculation algorithm using state transition equations in discrete time domain is devised and applied to a sampled system. As a result of simulation, the eigenvalue sensitivity coefficients calculated using discrete system models in discrete time domain are changed periodically and showed different values compared to those of continuous system model in time domain by the effect of periodic switching operations of TCSC.

Comparison of the first and the second order eigenvalue sensitivity coefficients affected by generator modeling (발전기 모델링 정도에 의한 고유치 일차${\cdot}$이차 감도계수 비교)

  • Kim Deok Young
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.345-347
    • /
    • 2004
  • In small signal stability analysis of power systems, eigenvalue analysis is the most useful method and the detailed modeling of generator has an important effect to the eigenvalues. Generator full model is used for precise dynamic analysis of generators and controllers while two-axis model is used for multi-machine systems because of the reduced order of the state matrix. Also, the eigenvalue sensitivity coefficients are used for optimizing controller parameters to improve system stability. This paper compare the first and second order eigenvalue sensitivity coefficients of controllers using generator full model with those of two-axis model. As a result of an example, the estimated eigenvalues using the first and the second eigenvalue sensitivity coefficients using generator full model is very close to those of state matrix. Also the error ratios throughout a wide range of controller parameters is less than $1\%$.

  • PDF

Design of Power System Stability for Local Mode Using Eigen-Sensivity (지역모드 제동을 위한 고유치 감도와 PSS 설계)

  • Song, S.G.;Nam, H.K.;Shim, K.S.;Kim, Y.G.
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.14-16
    • /
    • 2001
  • The Eigen-Sensitivity theory at full system is used to supplement drawback of the existing PSS gain tuning methods in this paper. Hessenberg method is used to linear analysis. This proposed method is successfully tested on KEPCO 2003 off-peak power system to improve local mode. The designed PSS at 2003 off-peak system is installed in 2003 peak system to improve robustness.

  • PDF

Analysis of the first order eigenvalue sensitivity affected by generator model (발전기 모델링 정도에 의한 고유치 감도계수에 미치는 영향해석)

  • Cho, Eon-Jung;Lee, Kun-Jae;Kim, Deok-Young
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.119-121
    • /
    • 2003
  • In small signal stability analysis of power systems, eigenvalue analysis is the most useful method and the detailed modeling of generator gives an important effect to the eigenvalues. Generator full model is used for precise dynamic analysis of generators and controllers while two-axis model is used for multimachine systems because of the reduced order of the state matrix. Also, the eigenvalue sensitivity coefficients are used for optimization of controller parameters to improve system stability. This paper compare the first order eigenvalue sensitivity coefficients of controllers in case of generator full model with those of two-axis model. As a result of an example the estimated eigenvalues using sensitivity coefficients in case of generator full model is very close to those of state matrix within 1% error ratios.

  • PDF

The active vibration control with force cancelling observer in elastic system (힘 상쇄 관측기를 이용한 탄성계 진동의 능동제어)

  • 박영필;이규섭;최봉환
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.5
    • /
    • pp.1016-1025
    • /
    • 1988
  • A force cancelling observed to control the vibration of a single degree of freedom elastic system subjected to an arbitrary, unmeasurable disturbance is considered in this paper. The main idea of a force cancelling observer is how an estimate of the excitation can be derived and used to generate a control force which reduces the vibration. This control is shown to be robust with respect to the parameters describing the behavior of the system. Experimental and numerical results are presented which show the efficacy of the observer when the system is excited by periodic, random, and impulsive torques.

Seismic Analysis of the Korean Peninsula Using Multiple Lapse Time Window Method (다중지연시간창법(MLTW)의 한반도 지진자료 적용성 분석)

  • Chung, Tae-Woong;Yoon, Suk-Yung
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.2
    • /
    • pp.199-207
    • /
    • 2009
  • From 329 earthquake data in the Korean Peninsula, we separated the intrinsic and scattering quality factor ($Q_i^{-1}$ and $Q_s^{-1}$) using the Multiple Lapse Time Window Analysis (MLTW) method. For the homogeneous velocity structure, $Q_i^{-1}$ reduces the amplitudes of both direct and coda waves; $Q_s^{-1}$ diminishes the direct wave amplitude but enlarges the coda wave amplitude. Based on this phenomenon, MLTW method analytically derives theoretical curves and obtains $Q_i^{-1}$ and $Q_s^{-1}$ by least square fit with observation curves. This study is the first approach for the seismic stable region by MLTW method, and show that $Q_i^{-1}$ and $Q_s^{-1}$ in the Korean Peninsula are very low at lower than frequencies of 5 Hz. This low value seems to be related to the inactive tectonism of the Korean Peninsula.