• Title/Summary/Keyword: 고온 단열

Search Result 91, Processing Time 0.023 seconds

The Effect of Properties of The Compressive Strength of High-Strength Concrete under High Temperature conditions at an Early Age (초기고온이력이 고강도콘크리트의 압축강도특성에 미치는 영향)

  • Ham, Eun-Young;Kim, Gyu-Yong;Koo, Kyung-Mo;Yoon, Min-Ho;Yoo, Jea-Kang;Miyauchi, Hiroyuki
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.115-116
    • /
    • 2013
  • Property of the compressive strength of high strength concrete was investigated in adiabatic temperature history considering hot-weather conditions. As a result, compressive strength of specimens subjected to high temperature history showed more than 120% at 3days of age compare to standard cured specimens. But, at 91days of age showed the incidence of strength less than 100%.

  • PDF

Effect of Variation of Heated Bottom Wall Area on Natural Convection in Square Enclosure with Inner Circular Cylinder (원형 실린더가 존재하는 사각 밀폐계 바닥면의 고온 영역 변화가 자연대류 현상에 미치는 영향)

  • Jo, Hyun Woo;Yoon, Hyun Sik;Lee, Hyo Jeong;Kim, Minsung;Ha, Man Yeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.11
    • /
    • pp.991-998
    • /
    • 2013
  • A numerical study is carried out for natural convection in an enclosure with an inner hot cylinder at the center. The top wall is cold, the bottom and both side walls of the enclosure are adiabatic, and the cylinder is heated. The bottom wall is heated locally at the middle. The ratio (w) is defined by as the width of the bottom wall to that of the heated local area. The immersed boundary method (IBM) is used to model an inner circular cylinder based on the finite volume method (FVM). This study investigates the effect of w on natural convection in an enclosure with an inner heated cylinder for Rayleigh numbers of $10^6$. At $6Ra=10^6$, thermal and flow fields show time-dependent characteristics after their full development.

Natural convection heat transfer from a hot body in the square enclosure with different boundary conditions (다른 경계조건을 갖는 밀폐공간 내에 존재하는 고온부로부터의 자연대류 열전달)

  • 권순석;정태현;권용일
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.12
    • /
    • pp.2395-2406
    • /
    • 1992
  • Laminar natural convection heat transfer from a hot body in a square enclosure has been studied for various center positions of a hot body at Grashof number Gr=1.5$\times$10/sup 5/, Prandtl number Pr=0.71 and dimensionless thermal conductivity K/sub s//K/sub f/= 14710. In case of vertical cold walls, the natural convection at the dimensionless center position of a hot body, X/sub c/Y/sub c/=0.2, 0.5 shows the most strong and at X/sub c/, Y/sub c/=0.5, 0.8 the most weak. In case of horizontal cold walls, the natural convection at the dimensionless center position of a hot body ; X/sub c/ Y/sub c/=0.5, 0.2 shows the most strong and at X/sub c/, Y/sub c/=0.2, 0.5 the most weak.

An Analysis on the Temperature Safety of a Boiler Desuperheater (보일러 과열증기 냉각기의 온도 안전성에 관한 연구)

  • Ha, Ji-Soo;Kim, Tae-Kwon;Chang, Hyuk-Sang
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.2
    • /
    • pp.9-13
    • /
    • 2012
  • The present study has been carried out to diagnose the temperature safety of a boiler desuperheater which decreases abnormally higher temperature of superheated steam in a reheater of a power plant. The liquid water in the desuperheater stays in a closed space. It becomes heated by the high temperature superheated steam and boiling could occur. Boiling might increase internal pressure and it could destroy the desuperheater if the internal pressure exceeds the allowable pressure of the desuperheater. The present study modeled reasonably the desuperheater and four cases of heat transfer analysis are executed with the consideration of insulator and natural convective fluid flow of the inside cooling water. For the case excluded the natural convective fluid flow, the temperature exceeds the allowable temperature and pressure. On the other hand, for the real case included natural convective fluid flow and insulator, the active heat transfer from higher temperature region to lower temperature region occurs and it makes the temperature in the cooling water below the allowable temperature and pressure. From this fact, it could be thought that the desuperheater in the reheater is safe from destroy or back flow.

Two-Dimensional Free Convection in a Rectangular Enclosure Composed of a Hot Wall and Partially Cold Side Wall (아래면이 고온이고 옆면의 일부가 저온인 4각형 밀폐공간에서의 2차원 자연대류에 관한 연구)

  • 이택식;고상근
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.2
    • /
    • pp.213-221
    • /
    • 1985
  • Two dimensional laminar natural convection in a rectangular enclousure composed of a hot bottom wall, a partially cold side wall and insulated walls except the above walls was studied by numerical analysis and also by esperiments. In the experiments, the temperature distributions in the enclosure and Nusselt number distribution along the hot and cold walls were obtained by the use of Mach-Zehnder interferometer. At first, numerical analysis with the boundary conditions of the experimental apparatus was performed and the comparison of the results of the numerical and the experimental results validated the numerical model good ennough. Heat transfer characteristics were investigated by applying the verified numerical model with the parameters, i.e. Grashof number, aspect ratio, position of cold plate and insulation condition. The results showed the optimal conditions of temperature distribution and the position of cold wall, and the characteristics of insulation materials.

Problem Solving about Practical Engineering Education based on Analysis on Optimized Internal Flow of LTP Furnace and Uniformity of Temperature (LTP 퍼니스의 내부 유동 및 온도 균일도 최적화를 위한 실천공학교육적 문제해결)

  • Kim, Jin-woo;Youn, Gi-man;Jo, Eunjeong
    • Journal of Practical Engineering Education
    • /
    • v.10 no.2
    • /
    • pp.125-129
    • /
    • 2018
  • This paper is about the numerical analysis on optimized internal flow of LTP furnace and uniformity of temperature. The LTP Furnace is the device that generates heat by electricity. And performs an annealing function for annealing the silicon wafer in the pre-semiconductor manufacturing process. Especially, the maximum temperature inside the chamber is maintained at a high temperature of about $400^{\circ}C$ to strengthen the wafer. When the process is completed at high temperature, the operation is repeated to reduce the temperature through the heat exchanger and carry it out. From this analysis, the ultimate goal is to derive the optimum design of the insulation volume supply/exhaust structure of the chamber through the flow analysis of the LTPS furnace. And to find cases for curriculum development.

Numerical Analysis on the Characteristic of Thermal Distribution for High Temperature Operating Battery Module (고온 작동형 전지모듈 온도분포 특성에 관한 수치해석)

  • Yi, Chung Seob;Lee, Byung Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.5
    • /
    • pp.102-108
    • /
    • 2013
  • In this study, the experiment result and numerical analysis on temperature distribution of a secondary battery module for high temperature operation type were compared. Because experimental battery has been in danger of explosions, experiment on temperature distribution was carried out using dummy batteries. Study on NAS battery module, which is secondary battery of high temperature operation type, is as follows ; Test result showed that battery's temperature is in steady state uniformly after 8 hours in each section. It is similar to experimental result for temperature distribution from the result of numerical analysis, and it takes about 8.5 hours to the $300^{\circ}C$.

Development of a Thermoelectric Dehumidifier (열전식 제습기 개발)

  • 주해호;이재원;이화조;권도중
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.753-757
    • /
    • 1996
  • 연전식 제습기는 제습판과 발열판, 열전식 열펌프, 팬과 모타, 직류 전원공급 장치로구성되어 있으며, 열전식 열펌프에 직류전원을 공급하면 고온면과 저온면이 발생하는 데 저온면의 온도룰 로점온도 이하로 냉각하여 공기중에 있는 수분을 제거하는 원리를 이용한 것이다. 초기 단계로 개발된 열전식 열펌프를 이용한 열전식 제습기(TED-92)는 기계식 제습기에 비하 여 제습효율이 너무 낮기 때문에, 본 연구에서는 여러 문제점을 개선하는 방법으로 열전식 열펌 프의 선정, 핀 설계, 제습기의 설계 등을 중점적으로 개선하여열전식 제습기 (TED-95)를 개발하 였다. 여러가지 방법으로 실험한 결과, 열전식 열펌프 CP1.4-127-045L 2개를 사용하여 발열판의 크기를 300 mm로 하여 단열재를 사용하지 않고 입력 전류를 4A를 입력하였을 때 단위전력당 제 습량이 가장 많았다. 열전식 제습기와 기계식 제습기를 비교실험 해본 결과, 열전식 제습기가 기 계식 제습기에 비해 약 21%의 제습효율을 나타 내었다. 그러므로 초기의 열전식 제습기 (TED-92) 보다 약 2배의 제습효율을 높였다.

  • PDF

가스발생기 뒷마개부의 열/구조 해석

  • 구송희;이방업;조원만
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.265-272
    • /
    • 1996
  • 액츄에이터에 사용되는 터어보 펌프의 터어빈을 구동시키기 위한 가스발생기용 고체연료 추진기관의 뒷마개부에 대하여 열/구조 해석을 수행하였다. 가스발생기는 장시간 연소모타로써 뒷마개에는 단열이 되어 있지 않은 배출튜브가 나사로 체결되어 고온, 고압의 연소가스에 의해 뒷마개 구조물에 작용하는 열 하중이 상당히 클 것으로 판단되므로, 최적설계를 위하여 뒷마개부의 열 및 구조해석을 수행하여 열하중의 영향을 예측하고 경량화를 위한 설계자료를 얻고자 하였다. 본 논문에서는 해석결과만을 언급하였으며 차후에 수행될 지상시험시에 해석치와 실험치를 비교한 후 좀 더 정확히 모델링을 하여 열/구조 해석 결과를 뒷마개부의 최적설계에 활용하고자 한다. 해석 결과 열하중이 연소관과의 조립부에는 거의 영향을 주지 않았으나, 열과 압력하중이 동시에 작용할 경우에 뒷마개 배출튜브의 조립부 근접한 곳에서 항복응력을 넘는 응력이 발생하여 정확한 구조 해석을 위해서는 탄소성해석을 수행하여야 할 것으로 판단된다.

  • PDF