• Title/Summary/Keyword: 고압송전선로

Search Result 12, Processing Time 0.023 seconds

Evaluation of Extremely Low Frequency Magnetic Fields emission Level from High Voltage Transmission Lines (고압 송전선로에서 극저주파 자기장 영향평가 적용에 관한 연구)

  • Jung, Joon Sig;Choi, Sung Ho;Jeon, Hyung Jin;Kim, Yoon Shin;Hong, Seung Cheol
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.5
    • /
    • pp.353-363
    • /
    • 2014
  • The purpose of this study was to investigated the ELF-MF emission level of various environments such as 258 facilities near located to high voltage transmission lines and 120 high voltage transmission lines, 17 underground cable lines. In addition, ELF-MF reduction rate according to separation distance was calculated by using simulations. An appropriate separation distance showing below 4mG was at least 70m. In the case of the appropriate separation distance for 120 high voltage transmission lines, 154kV required 20m of separation distance and 345kV required 60m of separation distance. The simulation results showed that the appropriate separation distance showing below 4mG was 40m and 60m for overhead 154kV and 345kV respectively. To adjust the worst conditions considering the aspects of environmental impact assessment study and the electric power currents that will increase in the future, the appropriate minimum separation distance for HVTL is judged to be above 70m in this study. Thus, there is a need to establish the greenbelt or buffer zone within 70m so as to create an environment in which the receptors are not exposed and thereby eliminate the risk factors of ELF-MF against humans.

A Safety Analysis of Electric Detonator for Stray Currents by Domestic Transmission Network System (국내 송전계통별 미주전류에 의한 전기뇌관의 안전성 분석)

  • Park Hyun-Sik;Kim Young-Seok;Kang Choo-Won
    • Tunnel and Underground Space
    • /
    • v.15 no.4 s.57
    • /
    • pp.296-304
    • /
    • 2005
  • This study is to observe stray currents generated around the steel tower by domestic transmission network system and analysis stability of electric detonator. It is measured the stay current of each ten place at steel tower of 765 kV, 345 tV, 154 tV transmission line among domestic transmission network system. Stay currents measured a total of 40m at intervals of 4m toward a line direction and a line vertical direction centering around steel tower. Temperature of the surface, EC, water content also are measured. Although stay currents show the highest values, that is 12 percent of at 4m and less than 1 percent of 40m with Institute of Makers of Explosives(IME) regulations. It is shown correlation between stay currents and water content$\cdot$EC$\cdot$temperature of the surface. Stay currents measured at line direction and line vertical direction were little different and the shape of diminution was also shown a similar aspect.

Analysis of Switching Surge Over-voltage in AC/DC Hybrid Transmission Lines (AC/DC 병가선로의 개폐서지 과전압 해석)

  • Yoo, Seong-Soo;Shin, Koo-Yong;Moon, Chae-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.3
    • /
    • pp.459-466
    • /
    • 2022
  • Switching surges are a common type of phenomenon that occur on any sort of power system network. These are more pronounced on long transmission lines and in high voltage converter stations. At AC/DC hybrid transmission lines, the insulation coordination of such lines is mainly dictated by the peak level of switching surges, the most dangerous of which include three phase line energization and AC/DC converter station. The power system structure consist of AC/DC hybrid transmission lines which is combination of AC 765kV and ±500kV HVDC 1 bipole system for contingency analysis. The power system under study and its components are simulated using EMTDC software package, the effects of the various AC/DC mixing power lines are reviewed. The developed models of EMTDC conversion lines based on combination of AC/DC system are simulated and the characteristics of switching surge over-voltage from its results are discussed.

Power Transmission by High Voltage Direct Current(HVDC)

  • Andersen, B.R.
    • KIPE Magazine
    • /
    • v.6 no.4
    • /
    • pp.12-20
    • /
    • 2001
  • 지난 세기의 시작 아래로, 50Hz 또는 60Hz로 운영되는 교류는 저력 계통 망의 송전과 배전에 지배적으로 사용되는 방법이었다. 그러나, 일반적으로 HVDC라 불리는, 고압 직류 송전은 매우 긴 장거리 선로에 대한 경제적 해법을 제공하고 이미 실현 비 동기화 AC계통 사이의 연계를 가능케 하였다. 50MW에서 6300MW까지의 각 Scheme별로 건설된 직류송전은 전세계적으로 총 59GW HVDC Scheme이 설치되어있으며, 이 기술을 위해서는 더 많은 응용이 고려되고 있다. 본 원고에서는 HVDC의 특성, 포함된 설비, HVDC의 사용 그리고 기술 발전의 요약을 기술하였다.

  • PDF

A Study on Diagnosis System Development of Overhead Transmission Lines (송전선로 이상진단 시스템 개발에 관한 연구)

  • Oh, Yong-Cheul;Kim, Tag-Yong;Lee, Dong-Kyu;Chung, Han-Seok;Kim, Chung-Hyeok;Lee, Deok-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1539-1540
    • /
    • 2015
  • 본 연구는 가공 활선 송전선로의 이상 진단을 위한 시스템 개발에 관한 것으로 송전 철탑 경간내에 설치되어 있는 송전선을 주행하며 전선의 내부 또는 외부의 열화를 확인하기 위한 것이다. 본 연구에 의한 시스템은 지상으로부터 30m 이상의 높이에서 설치되어 운행되기 때문에 바람에 의해 낙하되지 않도록 구성하였다. 또한 복도체 또는 4도체 선로를 주행하도록 설계하였으며 345kV 고압에서도 전계 및 자계의 영향을 받지 않도록 설계하였다. 전선의 이상 검지를 위해서 카메라를 설치하여 얻어진 데이터를 영상 처리 하여 이상 부위에 대한 에너지 변화를 관찰하여 이상 유무를 판단하도록 하였다. 완성된 시스템은 설치 및 이동을 위해서 경량화 시켰으며 분해 조립이 쉽도록 구성하였다. 본 시스템의 현장 적용에 의한 실험 결과 1m/sec의 이동 속도에서 1mm 이하의 스크래치에 대하여 검출이 가능하였다.

  • PDF

Study on Standardization of the Environmental Impact Evaluation Method of Extremely Low Frequency Magnetic Fields near High Voltage Overhead Transmission Lines (고압 가공송전선로의 극저주파자기장 환경영향평가 방법 표준화에 관한 연구)

  • Park, Sung-Ae;Jung, Joonsig;Choi, Taebong;Jeong, Minjoo;Kim, Bu-Kyung;Lee, Jongchun
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.6
    • /
    • pp.658-673
    • /
    • 2018
  • Social conflicts with extremely low frequency magnetic field(ELF-MF) exposures are expected to exacerbate due to continued increase in electric power demand and construction of high voltage transmission lines(HVTL). However, in current environmental impact assessment(EIA) act, specific guidelines have not been included concretely about EIA of ELF-MF. Therefore, this study conducted a standardization study on EIA method through case analysis, field measurement, and expert consultation of the EIA for the ELF-MF near HVTL which is the main cause of exposures. The status of the EIA of the ELF-MF and the problem to be improved are derived and the EIA method which can solve it is suggested. The main contents of the study is that the physical characteristics of the ELF-MF affected by distance and powerload should be considered at all stages of EIA(survey of the current situation - Prediction of the impacts - preparation of mitigation plan ? post EIA planning). Based on this study, we also suggested the 'Measurement method for extremely low frequency magnetic field on transmission line' and 'Table for extremely low frequency magnetic field measurement record on transmission line'. The results of this study can be applied to the EIA that minimizes the damage and conflict to the construction of transmission line and derives rational measures at the present time when the human hazard to long term exposure of the ELF-MF is unclear.

Constructing Topographies of EMF Risks from Underground Power Lines (전자파 위험 지형도의 상이한 구성: 지중 송전선로 위험 논쟁을 중심으로)

  • Kim, JooHui
    • Journal of Science and Technology Studies
    • /
    • v.19 no.3
    • /
    • pp.119-166
    • /
    • 2019
  • The risk of electromagnetic field(EMF) from power lines has been heavily disputed whenever high-voltage power line towers were built in South Korea. Local communities and civic groups had regarded burying the lines in the ground as an alternative to building power line towers. In 2014, however, when an elementary school science teacher reported the results of EMF measurements over the underground power lines to the Asian Citizens' Center for Environment and Health (ACCEH), the risk controversy over underground power lines took a whole new turn. The level of EMF from underground power lines turned out to be higher, and therefore more harmful than that from power line towers. In the debates that took place from then on over the EMF risk, ACCEH and NIER(National Institute of Environmental Research) presented conflicting topographies of EMF risk. This paper examines measuring practices of ACCEH and NIER by analyzing the measuring sites, measuring devices, and measuring heights chosen by each organization. This paper further examines how ACCEH and NIER mobilized various standards(EMF exposure limit, measurement guideline, categorization of carcinogens) differently. This controversy on the EMF from underground power lines of Seoul has raised concerns on the non-thermal effects of EMF in the long-term exposure and has led people to question whether burying the power lines is the safe alternative to building power line towers. Furthermore, this suggests conflicting answers on whether Seoul, where 90 % of transmission lines were already buried, is a safely managed place or not.

Study of social expenses measurement for extremely Low Frequency Electromagnetic field (극저주파 전자계관련 사회적기용의 계량화에 관한 연구)

  • Yoon, Byeong-Don;Seo, Jong-Wan;Lee, Jong-Soo;Kim, Jung-Bu;Shin, Myeong-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.319-321
    • /
    • 2007
  • 사회에서 지대한 관심과 논란의 대상이 되고 있는 한전의 고압전력 설비 중 송전선에서 발생하는 ELF(Extremely Low Frequency)전자계 저감을 위한 사회적비용의 계량화에 관한 연구를 하였다. 송전선로에서 발생되는 극저주파 전자계와 토지가격 사이의 관계론 규명하는 본 연구는 분서의 틀로서 극저주파 전자계 저감을 위한 다양한 기법에 대해서 제시하였다. 또한 다양한 황경가치 평가기법을 비교 분석한 결과, 헤도닉가격법이 가장 적정한 것으로 판단되어 이 분석법을 본 연구의 주된 분석도구로 삼고자 한다. 최근 환경질의 가치평가 기법으로 가장 광범위하게 사용되고 있는 기법중 하나인 헤도닉가격법은 기본적으로 주택, 토시 같은 재화는 그 자체가 가진 물리적 특성뿐만 아니라 외적인 환경 등 다양한 특성으로 이루어진 차별적 재화(differentiated product)라는 헤도닉가설(hedonic hypothesis)을 전제로 한다.

  • PDF

The Development Status of Power Conversion Technology for Power Grid (전력계통용 전력변환기술 개발 현황)

  • Lee, Eun-Jae;Baek, Seung-Taek;Choi, Ho-Seok;Kim, Young-Woo;Shim, Jae-Hyeok;Song, Sang-Wook
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.551-554
    • /
    • 2019
  • 국내 전력 계통은 경제의 성장과 더불어 생활 수준의 향상에 따라 지속적인 증설과 발전이 이루어졌다. 전력설비의 밀도 측면에서 비추어보면 미국이나 일본 대비 적게는 2배에서 많게는 4배에 이르는 최고 수준의 설비 밀도를 보이고 있다. 또한 전체 전력 생산량의 40%이상이 수도권에서 소비되고 있지만 발전설비는 최대 전력 수요지인 수도권과 먼 해안에 인접한 지역에 편재되어 있기 때문에 발생하는 수요와 공급지의 불균형, 장거리 선로를 통한 전력 전송에서 야기되는 전력계통 운영 측면에서의 문제가 발생하게 된다. 최근 화두가 되고 있는 원전 축소, 노후 화력 발전소 정지, 송전선로 경과지에서의 건설 고압 송전선로 건설 반대 등의 요인으로 인하여 전력계통을 최대한 효율적이고 안정적으로 운영하여야 하는 대전제를 만족시키기 위한 방안으로 기존 AC 기반의 계통 설비에 전력변환기술을 기반으로 하는 DC 계통 및 FACTS 설비의 확대 적용하는 방안이 제시되고 있다. 본 논문에서는 다가올 MV급 이상의 전력변환설비의 개념 및 개발 현황에 대한 소개를 하고자 한다.

  • PDF

A Study on Selection of an Overhead Electrical Transmission Line Corridor with Social Conflict (사회적 갈등을 갖는 송전선로 경과지 선정에 관한 연구)

  • Son, Hong-Chul;Moon, Chae-Joo;Kim, Hak-Jae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.4
    • /
    • pp.577-584
    • /
    • 2021
  • Electrical energy is an essential component in present societies, which is an important basis for our technological society. In the design of new power infrastructure, it is important to consider the psychological aspects of how our culture considers and aspects its development as an integral component of the community environment. The construction of new high voltage overhead transmission lines has become a controversial issue for public policy of government due to social opposition. The members of community are concerned about how these power lines may have an impact on their lives, basically caused by their effects on health and safety. The landscape and visual impact is one of the most impact that can be easily perceived for local community. The computer 3D simulation of new landscape is illustrated by a real life use corresponding to the selection of the power line route with least observability for local community. This paper used ArcGIS(geographic information system tool) for planning, survey, basic route and detailed route, route for implementation of transmission line corridor. Also, the paper showed the map of natural environment, living environment, safety and altitude using database of power line corridor, and transmission siting model was developed by this study. The suggested landscape of computer simulation with lowest visibility on a power line zone can contribute to reducing oppositions of local community and accelerating the construction of new power lines.