• Title/Summary/Keyword: 고관절 반치환술

Search Result 5, Processing Time 0.022 seconds

Midterm Results of Bipolar Hemiarthroplasty for Unstable Intertrochanteric Femoral Fractures Using a Type 3C Cementless Stem (불안정성 대퇴골 전자간 골절에 3C형 무시멘트 대퇴 스템을 이용한 고관절 반치환술의 중기 결과)

  • Chung, Woochull;Cho, Hong Man;Kim, Sun do;Park, Jiyeon;Kwon, Kihyun;Lee, Young
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.6
    • /
    • pp.503-510
    • /
    • 2020
  • Purpose: Bipolar hemiarthroplasty is used as an alternative to open reduction and internal fixation for unstable intertrochanteric fractures in elderly patients. Recent advances in medical systems and technologies have resulted in increased survival rates after intertrochanteric fractures of the femur, requiring selection of the appropriate femoral stems considering the mid- to long-term duration of survival. Hemiarthroplasty was performed for unstable intertrochanteric fractures using a double tapered quadrilateral femoral stem (C2 stem), and the clinical and radiological results were evaluated as a five-year follow-up post-surgery. Materials and Methods: From January 2004 to December 2013, 43 patients (43 hips) who underwent hemiarthroplasty with a C2 stem were enrolled in this study. Their mean age was 78.6 years (range, 70-84 years), and the mean follow-up period was 85.4 months (range, 60-96 months). During the follow-up period, clinical parameters, such as the changes in pain, walking ability, and functional status, were examined. Radiologically, changes in the proximal femur, such as osteoporosis and bone resorption of cortical bone, were noted. Complications that occurred during the follow-up period, such as dislocation and prosthetic features, were also reviewed. Results: Initially, the pain was relieved postoperatively, but it increased four years after surgery. The walking ability was reduced by two steps in nine patients after 60 months, and the Harris hip score was reduced significantly postoperatively after two to three years. Radiologically, cortical osteoporosis occurred in 14 patients. Five patients developed cortical bone resorption. Four of them showed nonunion of the trochanteric fracture fragments, and three of them suffered reverse oblique fractures. Conclusion: Careful selection considering the general health condition and remaining lifespan of the patient would be necessary for primary hip hemiarthroplasty using a 3C type cementless femoral stem for unstable intertrochanteric fractures in elderly patients with osteoporosis.

Comparative Study of Compliance for Venous Thromboembolism Prophylaxis (American College of Chest Physicians Guideline and American College of Orthopedic Surgeons Guideline) in High Risk Patients with a Venous Thromboembolism (정맥혈전 색전증 고위험군에서 시행한 혈전색전 예방요법(American College of Chest Physicians 지침 및 American College of Orthopedic Surgeons 지침)의 준수율 비교 연구)

  • Suh, You-Sung;Nho, Jae-Hwi;Jang, Byung-Woong;Kang, Deokwon;Won, Sung-Hun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.4
    • /
    • pp.317-326
    • /
    • 2019
  • Purpose: To compare and analyze the rate of prevention of two venous thromboembolism prophylaxis guidelines in patients with artificial joint arthroplasty and hip joint fracture. Proper prophylaxis for preventing thromboembolism in orthopedic surgery is significant because of this fetal complication. Materials and Methods: This study compared and retrospective analyzed the rate of prevention using the medical records and radiographs of patients who underwent orthopedic surgery from March 2009 to February 2011 according to the American College of Chest Physicians (ACCP) guidelines and from March 2012 to February 2014 according to the American Academy of Orthopedic Surgeons (AAOS) guidelines. Results: The guidelines for venous thromboembolism prophylaxis have been applied to patients with artificial joint replacement and hip joint fracture, the compliance rate of the ACCP guidelines was 56.0% before surgery, 67.0% after surgery with chemical prophylaxis, and 80.5% with mechanical prophylaxis. In addition, the compliance rate of the AAOS guidelines was 74.1% with chemical prophylaxis, and 88.3% with mechanical prophylaxis, which was higher than the ACCP guidelines. The compliance rates of mechanical and chemical prophylaxis before and after surgery of the ACCP guidelines, and the compliance rate of mechanical and chemical prophylaxis of the AAOS guidelines were compared and analyzed. The results revealed statistical significance (p<0.05) before and after total knee replacement arthroplasty and hip joint fracture internal fixation and total high risk orthopedic surgery. Conclusion: Raising the compliance rate of prophylaxis of venous thromboembolism in high risk orthopedic surgery is necessary and people should follow the guidelines for a unified direction depending on which situation they are in.

Learning Curve of the Direct Anterior Approach for Hip Arthroplasty (직접전방 접근법을 통한 인공 고관절 치환술의 학습곡선)

  • Ham, Dong Hun;Chung, Woo Chull;Choi, Byeong Yeol;Choi, Jong Eun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.2
    • /
    • pp.143-153
    • /
    • 2020
  • Purpose: To evaluate the timing of the improvement in surgical skills of the direct anterior approach for hip arthroplasty through an analysis of the clinical features and learning curve in 58 cases. Materials and Methods: From November 2016 to November 2018, 58 patients, who were divided into an early half and late half, and underwent hip arthroplasty by the direct anterior approach, were enrolled in this retrospective study. The operation time and complications (fracture, lateral femoral cutaneous nerve injury, heterotopic ossification, infection, and dislocation) were assessed using a chi-square test, paired t-test, and cumulative sum (CUSUM) test. Results: The mean operation times in total hip arthroplasty (26 cases) and bipolar hemi-arthroplasty were 132.1 minutes and 79.7 minutes, respectively, demonstrating a significant difference between the two groups. CUSUM analysis based on the results revealed breakthrough points of the operation time, decreasing to less than the mean operation time because of the 16th case in total hip arthroplasty and 14th case in bipolar hemiarthroplasty. Complications were encountered in the early phase and late phase: five cases of fractures in the early phase, no case in the late phase; eight and two cases of lateral femoral cutaneous nerve injury, respectively; three and two cases of heterotopic ossification, respectively; and one case of dislocation, one case of infection and three cases of others in the early phase. The CUSUM chart for the fracture rate during operation in the early phase revealed the following: five cases fracture (17.2%) in the early phase and no case in the late phase (0%). This highlights the learning curve and the need for monitoring the inadequacy of operation based on the complications. Conclusion: Hip arthroplasty performed by the direct anterior approach based on an anatomical understanding makes it difficult to observe the surgical field and requires a learning curve of at least 30 cases.

Surgical Treatment of Metastatic Tumor in Proximal Femur with Recycling Autograft Prosthetic Composite after Wide Excision (근위 대퇴골 전이성 종양의 수술적 치료로서 광범위 절제술 후 재활용 자가골을 이용한 복합 고관절 성형술)

  • Kim, Jae-Do;Park, Pil-Jae;Kwon, Young-Ho;Jang, Jae-Ho;Lee, Young-Gu
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.11 no.1
    • /
    • pp.71-81
    • /
    • 2005
  • Purpose: Due to local recurrence of tumor, metal failure usually develops in patients who underwent internal fixation or hip joint arthroplasty after curettage in the case of metastatic tumor of proximal femur. The aim of this study is to find out the appropriateness of reconstruction using recycling autograft after wide excision in the case of metastatic bone tumor by performing recycling autograft and hip joint arthroplasty after wide excision, and through presence or absence of local recurrence, functions of lower limbs and occurrence of complications. Materials and Methods: Five patients, in 6 cases, who had undergone reconstruction using recycling autograft prosthetic composite after wide excision in the metastatic tumor from May 2000 to May 2003 were included in this study. The average age of the patients was 60.8 years of age with male to female ratio of 3:2. Average duration of lives following surgery was 23.3 month (7-57 months). Primary lesion included 2 cases of lung cancer, and 1 each of stomach cancer, renal cancer and multiple myeloma. After wide excision, the hip joint was reconstructed with recycling autograft prosthetic composite ; 4 cases of extracorporeal irradiation and 2 cases of pasteurization. Musculoskeletal Tumor Society (MSTS) score(1993) for 6-month period after surgery, as well as presence of complication and local recurrence during the rest of their lives, were studied. Results: Average Musculoskeletal Tumor Society (MSTS) score over the 6-month period after surgery was 63.3% and 1 case of dislocation of hip joint, as a complication following surgery, was discovered. Local recurrence during the lives of the patients was not observed. Conclusion: In the case of metastatic tumor of proximal femur, in which the life span following surgery is expected to be more than 6 months, undergoing reconstruction using recycling autograft after wide excision, in comparison to internal fixation or hip joint arthroplasty after curettage, is deemed to have better results in prevention of local recurrence, and preservation of the functions of all limbs during the life span of the patient.

  • PDF

A Clinical Analysis of Femur Neck Fracture in Elderly Patients (노년층에서 대퇴경부 골절의 치료)

  • Ihin, Joo-Choul;Ahn, Myun-Whan;Seo, Jae-Sung
    • Journal of Yeungnam Medical Science
    • /
    • v.2 no.1
    • /
    • pp.11-22
    • /
    • 1985
  • Femur neck fracture is well known as one of the major death cause after trauma in elderly patients, and unsolved fracture due to its frequent association with complications such as avascular necrosis and nonunion. Through meticulous evaluation of the patient, hip and surgeon's experiences, reduction of mortality and morbidity as well as rapid recovery of the patient to the preinjury social and ambulatory status without local complications and revision after treatment is urgently needed. Many factors about this fracture In itself were noted, but we have analyzed 18 femur neck fractures of the patients older than 50 years preliminarily according to age, fracture pattern, osteoporosis, etiology and method of treatment with its delay in association with major complications especially avascular necrosis and nonunion. The results are as follows; 1. Of these 18 fractures, 11 were in females, 8 were caused by minor trauma such as slip-down accident and 4 were associated with definite osteoporosis according to the Sing's classification. 2. Fracture pattern of these 18 are undisplaced in 4, displaced subcapital in 11, displaced transcervical in 3. 11 fractures in the patients older than 60 year are composed of 3 undisplaced or impacted fractures and 8 displaced subcapital fractures. 3. These 18 fractures were treated by closed reduction and Internal fixation with multiple pins in 13, and hemiarthroplasty in 4, but one was not treated to die after discharge from hospital. 4. 4 undisplaced or impacted fractures and 3 displaced transcervical fractures were not associated with any complications such as avascular necrosis or nonunion. But 4 of 6 displaced subcapital fractures were complicated by avascular necrosis, 3 of which were reduced in the varus position within 1 week, and the other was reduced in the good position on 1 week after trauma. There was no complication in 2 displaced subcapital fractures reduced in valgus position within 3 days after trauma. According to the above results, the prognosis of the femur neck fracture is dependent upon the fracture pattern and delay in its treatment. So it is inevitable to reduce the fracture in anatomical or valgus position as early as possible. But the arthroplasty may be needed in displaced subcapital fractures delayed for several days, with its reluction in extreme varus position or impossible and with pre-existing disease in the same hip Joint (total hip replacement).

  • PDF