• Title/Summary/Keyword: 계산 AC/A

Search Result 117, Processing Time 0.022 seconds

AC susceptibility of current-carrying iron whiskers : Effect of current variation (전류에 의한 철단결정의 교류 자기감수율 : 전류 변화에 의한 효과 )

  • Jae-Gwang Lee
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.3
    • /
    • pp.179-184
    • /
    • 1995
  • The ac magnetic susceptibility of {100} iron whiskers as a function of currents is studied with and without external field. The ac susceptibility depends on the magnitude and the direction of the applied dc current when a small external field is applied along the magnetization of the central domain of the whisker. Variation of the central domain size accounts for the current-dependent response. The measured magnetic responses are explained, using a micromagnetic calculation based on a simple model, as a function of applied currents over a wide range except critical values.

  • PDF

An Efficient Hardware Design for Scaling and Transform Coefficients Decoding (스케일링과 변환계수 복호를 위한 효율적인 하드웨어 설계)

  • Jung, Hongkyun;Ryoo, Kwangki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.10
    • /
    • pp.2253-2260
    • /
    • 2012
  • In this paper, an efficient hardware architecture is proposed for inverse transform and inverse quantization of H.264/AVC decoder. The previous inverse transform and quantization architecture has a different AC and DC coefficients decoding order. In the proposed architecture, IQ is achieved after IT regardless of the DC or AC coefficients. A common operation unit is also proposed to reduce the computational complexity of inverse quantization. Since division operation is included in the previous architecture, it will generate errors if the processing order is changed. In order to solve the problem, the division operation is achieved after IT to prevent errors in the proposed architecture. The architecture is implemented with 3-stage pipeline and a parallel vertical and horizontal IDCT is also implemented to reduce the operation cycle. As a result of analyzing the proposed ITIQ architecture operation cycle for one macroblock, the proposed one has improved by 45% than the previous one.

Design of MSR for Magnetic Field Shielding of Low Frequency (저주파 자기장 차폐를 위한 자기차폐실 설계)

  • Choi, Hak-Yun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.154-159
    • /
    • 2010
  • In this paper, the magnetically shielded room for low magnetic field shielding is designed and measured by fabricated. The size of magnetically shielded room was 3.0[m](W)$\times$3.0[m](L)$\times$3.0[m](H) to enter the industrial measuring instruments and analyzed DC and AC shielding characteristics of magnetic materials with a high permeability and AC shielding characteristics by eddy current of conductive materials. As a results, shielded room dimensions were obtained. To verify the analysis results, magnetically shielded room is fabricated and the calculated results are compared with the measured results. The Measured results show good agreement with calculated results. According to measurements, 5 times of 0.1[Hz] and 86 times of 60[Hz] is achieved at low frequency. The fabricated shielding room can be used as the magnetically shielding room for low magnetic field shielding.

Calculation of the Induced Voltage and Current for a Human and an Object Close to 765kV AC Double Circuit Transmission Line (765kV 교류 2회선 송전선 인근의 생체 및 물체 유도 전압, 전류 계산)

  • Min, Suk-Wen;Kim, Eung-Sik;Myeong, Sung-Mo;Lee, Byeong-Yoon;Park, Jong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1509-1511
    • /
    • 1994
  • This paper calculates the induced voltage and current for a human and a car under 765 kV AC double circuit transmission line. A human and a car is simulated as two dimension by the use of charge simulation method and as three dimension by using surface charge method. The phase arrangement of transmission line is varied to calculate the induced voltage and current. In two cases a human and a car is grounded or floated, the induced voltage and current is also compared.

  • PDF

A Research on the Estimation Method for the SOC of the Lithium Batteries Using AC Impedance (AC 임피던스를 이용한 리튬 전지의 충전상태 추정에 관한 연구)

  • Lee, Jong-Hak;Kim, Sang-Hyun;Kim, Wook;Choi, Woo-Jin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.457-465
    • /
    • 2009
  • Lithium batteries are widely used in mobile electronic devices due to their higher voltage and energy density, lighter weight and longer life cycle compared to other secondary batteries. In particular, high demand for lithium batteries is expected for electric cars. In case of lithium batteries used in electric cars, driving distance must be calculated accurately and discharging should not be done below the level of making it impossible to crank. Therefore, accurate information about state of charge (SOC) becomes an essential element for reliable driving. In this paper, a new method of estimating the SOC of lithium polymer batteries by using AC impedance is proposed. In the proposed method, parameters are extracted by fitting a curve of impedance measured at each frequency on the equivalent impedance model and extracted parameters are used to estimate SOC. Experiments were conducted on lithium polymer batteries with similar capacities made by different manufacturers to prove the validity of the proposed method.

Load Flow Calculation by Neural Networks (신경회로적인 전력조류 계산법에 대한 연구)

  • Kim, Jae-Joo;Park, Young-Moon
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.329-332
    • /
    • 1991
  • This paper presents an algorithm to reduce the time to solve Power Equations using a Neural Net. The Neural Net is trained with samples obtained through the conventional AC Load Flow. With these samples, the Neural Net is constructed and has the function of a linear interpolation network. Given arbitrary load level, this Neural Net generates voltage magnitudes and angles which are linear interpolation of real and reactive powers. Obtained voltage magnitudes and angles are substituted to Power Equations, Real and reactive powers are found. Thus, a new sample is generated. This new experience modifies weight matrix. Continuing to modify the weight matrix, the correct solution is achieved. comparing this method with AC Load flow, this method is faster. If we consider parallel processing, this method is far faster than conventional ones.

  • PDF

Active Power Filter Type Uninterruptible Power Supply (UPS) (전력용 능동필터형 무정전 전원장치)

  • 김제홍;최재호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.4
    • /
    • pp.100-105
    • /
    • 1998
  • This paper proposes a new control strategy of bidirectional uninterruptible power supply (UPS) with the performance of active power filter which compensates the harmonics and reactive power. With only one power stage, it is working simultaneously as the AC/DC rectifier/battery charger and DC/AC inverter to the operation of battery charging or back-up power supplying. Therefore the operation of the proposed system can be divided into the modes, such as the active power filter mode and the battery back-up power mode. And a novel closed-loop control strategy is used to calculate the reference current. The performance of the proposed 5[kVA] system is verified by the simulation and experimental results.

  • PDF

Reduction of Torque Ripple due to Current-Sensing Errors in Inverter-Fed AC Motor Systems (인버터의 전류측정 오차에 기인하는 교류전동기의 토크리플 저감)

  • 윤덕용;홍순찬
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.280-286
    • /
    • 1998
  • This paper proposes a novel method to reduce the torque ripple due to the non-ideality of the current sensing parts in vector-controlled inverter-fed AC motor drive systems. For PMSM(Permanent Magnet Synchronous Motor), motor output torque equations are derived in terms of their offset voltages and different voltage transducing gains. And the effects of phase current errors on motor torque are analyzed for both salient PMSM and non-salient PMSM. The proposed method can eliminate the torque ripple by nulling the offset voltages and setting the voltage transducing gains to the same value. To verify the proposed method, digital simulations are carried out for non-salient PMSM.

  • PDF

A Study on Vector Control of ac motor using Low-Voltage DSP (저전압용 DSP칩을 이용한 서보 모터의 벡터제어에 관한 연구)

  • Bang, Seoung-Hyun;Choi, Chi-Young;Hong, Sun-Gi
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.76-79
    • /
    • 2002
  • 본 논문에서는 고성능 AC 서보 모터에 대하여 제어 시스템을 구현하고, 제어기를 설계한다. 하드 웨어구성은 모터 전용 저전압 DSP칩인 TMS320LF2407 칩을 이용한다. TMS320LF2407는 최근의 저전력 구동 추세에 따라 3.3V를 구동 전압으로 이용하는 DSP 칩이다 연산 처리 속도는 40MIPS로 빠른 연산 처리능력을 가지고 있지만 주변 소자들과의 인터페이스(보통 5V로 동작)와 노이즈에 대한 대책을 고려하여야 한다. 본 논문에서는 이러한 전압 호환과 노이즈를 가능한 제거한 서보 모터 제어기를 구성하며, 또한 유효 전압 인가시간의 관점에서 바라본 개선된 공간 벡터 PWM방식을 적용함으로써 계산과정과 프로그램을 간단히 하고, 전류제어를 소프트웨어 방식으로 처리하여 복잡한 하드웨어를 간략화 시키고자 한다 이런 과정에 의하여 앞으로 요구될 수 있는 고성능 다기능을 위한 효용성을 높이고자 한다.

  • PDF

A Lecture Note on PU Method thru Calculation of a Simple DC Circuit and Voltage/Fault Analysis of Industrial Power Systems using Actual Data (PU법에 의한 DC 회로계산 및 실계통 데이터를 이용한 전압강하/고장계산 방법)

  • Lee, Sang-Joong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.45-54
    • /
    • 2014
  • This paper presents a lecture note of pu method for power system analysis. The author tries to help students in class better understand the fundamental of pu calculation using a very simple DC circuit. And a voltage drop calculation by pu method for a distribution system is given to help understand the importance of the vector reference in AC circuit analysis. A short current calculation by pu method for a power system with a generator, transformer and transmission line is also presented to show how pu calculation can be applied to real power systems, in which all the data are the ones currently being used by KEPCO and other industrial sites.