• Title/Summary/Keyword: 계면변수

Search Result 256, Processing Time 0.035 seconds

Coolant Leak Effect on Polymer Electrolyte Membrane Fuel Cell (고분자전해질연료전지의 냉각수 누설에 대한 연구)

  • Song, Hyun-Do;Kang, Jung-Tak;Kim, Jun-Bom
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.4
    • /
    • pp.301-305
    • /
    • 2007
  • The performance of polymer electrolyte membrane fuel cell could be decreased due to coolant leaked from connection part. Micro pump was used to put small amount of coolant and investigate the effect on fuel cell. The stoichiometric ratio of hydrogen/air was 1.5/2.0, both side of gas was fully humidified, and current density of $400mA/cm^2$ was used as standard condition in this experiment. Constant current method was used to check performance recovery from coolant effect in 3 cell stack. The performance was recovered when coolant was injected in cathode side. On the other hand, the performance was not recovered when coolant was injected in anode side. Ethylene glycol could be converted to CO in oxidation process and cause poisoning effect on platinum catalyst or be adhered on GDL and cause gas diffusion block effect resulting performance decrease. Water with nitrogen gas was supplied in anode side to check performance recovery. Polarization curve, cyclic voltammetry, electrochemical impedance spectroscopy was used to check performance, and gas chromatography was used to check coolant concentration. Constant current method was not enough in full recovery of performance. However, water injection method was proved good method in full recovery of performance.

Effect of Green Microstructure on Sintered Microstructure and Mechanical Properties of Reaction-Bonded Silicon Carbide (성형미세구조가 반응소결 탄화규소체의 소결미세구조 및 기계적 특성에 미치는 영향)

  • 박현철;김재원;백운규;최성철
    • Journal of the Korean Ceramic Society
    • /
    • v.36 no.1
    • /
    • pp.97-105
    • /
    • 1999
  • In the binary system of SiC and carbon, porosity and pore size distribution of green body was controlled by varying pH, by the addition of polyelectrolyte dispersants, and by using different particle size of starting powders. The preforms having different green microstructure were fabricated by slip casting from suspensions having different dispersion condition. The reaction bonding process was carried out for these preforms. The condition of reaction bonding was 1600$^{\circ}C$ and 20 min. under vacuum atmosphere. The analyses of optical and SEM were studied to investigate the effect of green microstructure on that of reaction bonded silicon carbide and subsequently the mechanical properties of sintered body was investigated. Different green microstructures were obtained from suspensions having different dispersion condition. It was found that the pore size could be remarkably reduced for a fine SiC(0.5$\mu\textrm{m}$). The bimodal microstructure was not found in the present study, which is frequently observed in the typical reaction bonded silicon carbide. It is considered that the ratio between SiC and C was responsible for the formation of bimodal microstructure. For the preform fabricated from the well dispersed suspension, the 3-point bending strength of reaction-bonded silicon carbide was 310${\pm}$40 MPa compared to the specimen fabricated from relatively agglomerated particles having lower value 260${\pm}$MPa.

  • PDF

A Study on the Solubilization of $\alpha$-Chymotrypsin Using AOT Reverse Micelles; Effects of pH and salts (AOT 역미셀을 이용한 $\alpha$-chymotrypsin의 가용화에 대한 연구;pH와 염의 영향)

  • 노선균;강춘형
    • KSBB Journal
    • /
    • v.15 no.6
    • /
    • pp.664-669
    • /
    • 2000
  • Micellar aggregates are known to be useful for the selective isolation of biologically active materials such as amino acids, proteins, and enzymes from crude mixtures sparsely dispersed in water. In this study, the effects of pH, salt type and its concentration on the solubilization of $\alpha$-chymotrypsin into the organic micellar phase, which consisted of AOT (sodium 야(2-ethylhexy)sulfosuccinate) and iso-octane, were comprehensively examined. It was found that maximum extraction efficiency was attained at a pH below the isoelectric point of $\alpha$-chymotrypsin; at pH=5.0 for NaCl and KCl, and at pH=7.0 for $CaCl_2$and $MgCl_2$. In order to avoid complications stemming from the precipitationof protein at low pH interfaces, the protein concentrations in the organic and aqueous phases were directly measured. The size of the micelle water pool was estimated by measuring the molar ratio of the surfactant to the water, W(sub)o. The resulting values of W(sub)o were nearly constant at 30 and 19 for NaCl and KCl, respectively, and were independent of pH. The addition of 1:2 salts like $MgCl_2$and $CaCl_2$ led to much lower, but a constant value of, W(sub)o than the 1:1 salts.

  • PDF

p-Version Finite Element Analysis of Composite Laminated Plates with Geometric and Material Nonlinearities (기하 및 재료비선형을 갖는 적층평판의 p-Version 유한요소해석)

  • 홍종현;박진환;우광성
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.3
    • /
    • pp.491-499
    • /
    • 2002
  • A p-version finite element model based on degenerate shell element is proposed tot the analysis of orthotropic laminated plates. In the nonlinear formulation of the model, the total Lagrangian formulation is adopted with large deflection and moderate rotation being accounted tot in the sense of yon Karman hypothesis. The material model is based on the Huber-Mises yield criterion and Prandtl-Reuss flow rule in accordance with the theory of strain hardening yield function, which is generalized lot anisotropic materials by introducing the parameters of anisotropy. The model is also based on extension of equivalent-single layer laminate theory(ESL theory) with shear deformation, leading to continuous shear strain at the interface of two layers. The integrals of Legendre polynomials are used for shape functions with p-level varying from 1 to 10. Gauss-Lobatto numerical quadrature is used to calculate the stresses at the nodal points instead of Gauss points. The validity of the proposed P-version finite element model is demonstrated through several comparative points of iew in terms of ultimate load, convergence characteristics, nonlinear effect, and shape of plastic tone.

An Experimental Study on the Flexural Behavior of Slab Repaired and Reinforced with Strand and Polymer Mortar (강연선과 폴리머 모르타르에 의해 보수보강된 슬래브의 휨거동에 대한 실험적 고찰)

  • Yang Dong-Suk;Hwang Jeong-Ho;Park Sun-Kyu
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.2 s.86
    • /
    • pp.171-177
    • /
    • 2005
  • Even though the cost associated with the repair and rehabilitation of existing structures are rapidly increasing, vast number of the repaired and rehabilitated structures do not function properly as expected during their remaining service lives. This paper focused on the flexural behavior of reinforced concrete slabs repaired and reinforced by PS strand and polymer mortar in the tension face. The slabs have the size of 700${\times}120{\times}$2200 m and 700${\times}120{\times}$1300 mm. Variables of experiment were space of strengthening, chipping, the number of strand, the kind of mortar in this experimental study. Attention is concentrated upon overall bending capacity, deflection, ductility and failure mode of repaired and reinforced slabs. Test results show that deflection of repaired and reinforced slabs reduced to approximately $40 \%$ comparison to standard slabs. Boundary cracking of chipping slab started ultimate load afterward. Concrete-mortar interface cracked 64.5 kN in repaired slab with AP mortar and 36.0 kN in repaired slab with general polymer mortar. Reinforcement effect increased with reducing space of strand. Also, Reinforcement effects are more by strand than by polymer mortar.

Thermo-Mechanical Analysis of Though-silicon-via in 3D Packaging (Though-silicon-via를 사용한 3차원 적층 반도체 패키징에서의 열응력에 관한 연구)

  • Hwang, Sung-Hwan;Kim, Byoung-Joon;Jung, Sung-Yup;Lee, Ho-Young;Joo, Young-Chang
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.17 no.1
    • /
    • pp.69-73
    • /
    • 2010
  • Finite-element analyses were conducted to investigate the thermal stress in 3-dimensional stacked wafers package containing through-silicon-via (TSV), which is being widely used for 3-Dimensional integration. With finite element method (FEM), thermal stress was analyzed with the variation of TSV diameter, bonding diameter, pitch and TSV height. It was revealed that the maximum von Mises stresses occurred at the edge of top interface between Cu TSV and Si and the Si to Si bonding site. As TSV diameter increased, the von Mises stress at the edge of TSV increased. As bonding diameter increased, the von Mises stress at Si to Si bonding site increased. As pitch increased, the von Mises stress at Si to Si bonding site increased. The TSV height did not affect the von Mises stress. Therefore, it is expected that smaller Cu TSV diameter and pitch will ensure mechanical reliability because of the smaller chance of plastic deformation and crack initiation.

Recent Research Trends of Mixed Matrix Membranes for CO2 Separation (이산화탄소 분리용 혼합 매질 분리막 최신 연구 동향)

  • Chi, Won Seok;Lee, Jae Hun;Park, Min Su;Kim, Jong Hak
    • Membrane Journal
    • /
    • v.25 no.5
    • /
    • pp.373-384
    • /
    • 2015
  • In the past few decades, polymeric membrane has played an important role in gas separation applications. For the separation of $CO_2$, one of greenhouse gases, high permselectivity, long-term stability and scale-up are needed. However, conventional polymeric membranes have shown a trade-off relation between permeability and selectivity while inorganic materials are highly permeable but expensive. Mixed matrix membranes (MMMs) combining the advantages of both polymeric and inorganic materials have become a possible breakthrough for the next-generation gas separation membranes. The MMMs could be either symmetric or asymmetric but the latter is more preferred to improve the permeance. Important factors influencing the MMM fabrication include homogeneous distribution of inorganic particles and good interfacial contact between inorganic filler and organic matrix. Recently, metal organic frameworks (MOFs) have received much attention as a new class of porous crystalline materials and a potential candidate for $CO_2$ separation. Zeolitic imidazolate frameworks (ZIFs), a sub-branch of MOFs, are the most widely used in MMMs due to small particle size and appropriate pore size for $CO_2$ separation. One of the major issues associated with the incorporation of porous particles in a polymeric membrane is to control the microstructure of the porous particle materials such as particle size, orientation, and boundary conditions etc. In this review, major challenges surrounding MMMs and the strategies to tackle these challenges are given in detail.

Thickness Determination of Ultrathin Gate Oxide Grown by Wet Oxidation

  • 장효식;황현상;이확주;조현모;김현경;문대원
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.107-107
    • /
    • 2000
  • 최근 반도체 소자의 고집적화 및 대용량화의 경향에 다라 MOSFET 소자 제작에 이동되는 게이트 산화막의 두께가 수 nm 정도까지 점점 얇아지는 추세이고 Giga-DRAM급 차세대 UNSI소자를 제작하기 위해 5nm이하의 게이트 절연막이 요구된다. 이런 절연막의 두께감소는 게이트 정전용량을 증가시켜 트랜지스터의 속도를 빠르게 하며, 동시에 저전압동작을 가능하게 하기 때문에 게이트 산화막의 두께는 MOS공정세대가 진행되어감에 따라 계속 감소할 것이다. 따라서 절연막 두께는 소자의 동작 특성을 결정하는 중요한 요소이므로 이에 대한 정확한 평가 방법의 확보는 공정 control 측면에서 필수적이다. 그러나, 절연막의 두께가 작아지면서 게이트 산화막과 crystalline siliconrksm이 계면효과가 박막의 두께에 심각한 영향을 주기 때문에 정확한 두께 계측이 어렵고 계측방법에 따라서 두께 계측의 차이가 난다. 따라서 차세대 반도체 소자의 개발 및 양산 체계를 확립하기 위해서는 산화막의 두께가 10nm보다 작은 1nm-5nm 수준의 박막 시료에 대한 두께 계측 방법이 확립이 되어야 한다. 따라서, 본 연구에서는 습식 산화 공정으로 제작된 3nm-7nm 의 게이트 절연막을 현재까지 알려진 다양한 두께 평가방법을 비교 연구하였다. 절연막을 MEIS (Medim Energy Ion Scattering), 0.015nm의 고감도를 가지는 SE (Spectroscopic Ellipsometry), XPS, 고분해능 전자현미경 (TEM)을 이용하여 측정 비교하였다. 또한 polysilicon gate를 가지는 MOS capacitor를 제작하여 소자의 Capacitance-Voltage 및 Current-Voltage를 측정하여 절연막 두께를 계산하여 가장 좋은 두께 계측 방법을 찾고자 한다.다. 마이크로스트립 링 공진기는 링의 원주길이가 전자기파 파장길이의 정수배가 되면 공진이 일어나는 구조이다. Fused quartz를 기판으로 하여 증착압력을 변수로 하여 TiO2 박막을 증착하였다. 그리고 그 위에 은 (silver)을 사용하여 링 패턴을 형성하였다. 이와 같이 공진기를 제작하여 network analyzer (HP 8510C)로 마이크로파 대역에서의 공진특서을 측정하였다. 공진특성으로부터 전체 품질계수와 유효유전율, 그리고 TiO2 박막의 품질계수를 얻어내었다. 측정결과 rutile에서 anatase로 박막의 상이 변할수록 유전율은 감소하고 유전손실은 증가하는 결과를 나타내었다.의 성장률이 둔화됨을 볼 수 있다. 또한 Silane 가스량이 적어지는 영역에서는 가스량의 감소에 의해 성장속도가 둔화됨을 볼 수 있다. 또한 Silane 가스량이 적어지는 영역에서는 가스량의 감소에 의해 성장속도가 줄어들어 성장률이 Silane가스량에 의해 지배됨을 볼 수 있다. UV-VIS spectrophotometer에 의한 비정질 SiC 박막의 투과도와 파장과의 관계에 있어 유리를 기판으로 사용했으므로 유리의투과도를 감안했으며, 유리에 대한 상대적인 비율 관계로 투과도를 나타냈었다. 또한 비저질 SiC 박막의 흡수계수는 Ellipsometry에 의해 측정된 Δ과 Ψ값을 이용하여 시뮬레이션한 결과로 비정질 SiC 박막의 두께를 이용하여 구하였다. 또한 Tauc Plot을 통해 박막의 optical band gap을 2.6~3.7eV로 조절할 수 있었다. 20$0^{\circ}C$이상으로 증가시켜도 광투과율은 큰 변화를 나타내지 않았다.부터 전분-지질복합제의 형성 촉진이 시사되었다.이것으로 인하여 호화억제에 의한 노화 방지효과가 기대되었지만 실제로 빵의 노화는 현저히 진행되었다

  • PDF

Convergence Study on Damage and Static Fracture Characteristic of the Bonded CFRP structure with Laminate angle (적층 각도를 가진 CFRP 접착 구조물의 파손 및 정적 파괴 특성에 관한 융합 연구)

  • Lee, Jung-Ho;Kim, Eundo;Cho, Jae-Ung
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.1
    • /
    • pp.155-161
    • /
    • 2019
  • As composite is the light weight material whose durability and mechanical property are more superior than the existing general material. By taking notice of the composite with light weight, this study was about to investigate the static fracture characteristic of the bonded CFRP structure jointed with adhesive. Also, CFRP double cantilever beam with the variable of laminate angle was designed and the static fracture analysis was carried out. The laminate angles of CFRP double cantilever beam designed for this study were $30^{\circ}$, $45^{\circ}$ and $60^{\circ}$ individually. As the study result, the specimen with the laminate angle of $45^{\circ}$ was shown to have the durability better than those with the layer angles of $30^{\circ}$ and $45^{\circ}$. It was checked that the specimen with the laminate angle of $30^{\circ}$ had the weakest durability among all specimens. The damage data of the bonded CFRP structure by laminate angle could be secured through this study result. As the damage data of bonded interface obtained on the basis of this study result are utilized, the esthetic sense can be shown by being grafted onto the machine or structure at real life.

Study on Adsorption Equilibrium, Kinetic and Thermodynamic Parameters of Murexide by Activated Carbon (입상 활성탄에 의한 Murexide의 흡착 평형, 동력학 및 열역학 파라미터에 관한 연구)

  • Lee, Jong-Jib
    • Clean Technology
    • /
    • v.25 no.1
    • /
    • pp.56-62
    • /
    • 2019
  • The equilibrium, kinetic and thermodynamic parameters of adsorption of murexide by granular activated carbon were investigated. The experiment was carried out by batch experiment with the variables of the amount of the adsorbent, the initial concentration of the dye, the contact time and the temperature. The isothermal adsorption equilibrium was best applied to the Freundlich equation in the range of 293 ~ 313 K. From the separation factor (${\beta}$) of Freundlich equation, it was found that adsorption of murexide by granular activated carbon could be the appropriate treatment method. The adsorption energy (E) obtained from the Dubinin- Radushkevich equation shows that the adsorption process is a physical adsorption process. From the kinetic analysis of the adsorption process, pseudo second order model is more consistent than pseudo first order model. It was found that the adsorption process proceeded to a spontaneous process and an endothermic process through Gibbs free energy change ($-0.1096{\sim}-10.5348kJ\;mol^{-1}$) and enthalpy change ($+151.29kJ\;mol^{-1}$). In addition, since the Gibbs free energy change decreased with increasing temperature, adsorption reaction of murexide by granular activated carbon increased spontaneously with increasing temperature. The entropy change ($147.62J\;mol^{-1}\;K^{-1}$) represented the increasing of randomness at the solid-solution interface during the adsorption reaction of murexide by activated carbon.