• Title/Summary/Keyword: 경조직의 안정성

Search Result 13, Processing Time 0.036 seconds

A Study on the Postoperative Stability of Hard Tissue in Orthognathic Surgery Patients Depending on the Difference of Occlusal Plane (악교정 수술시 교합평면의 차이에 따른 술후 경조직의 안정성에 관한 연구)

  • Hwang, Chung-Ju;Lim, Seon-A;Moon, Jeong-Lyon
    • The korean journal of orthodontics
    • /
    • v.29 no.2 s.73
    • /
    • pp.239-249
    • /
    • 1999
  • In orthognathic surgery to obtain proper functional and esthetic form after skeletal discrepancy treatment, precise diagnosis and treatment plan are essential. Especially in two jaw surgeries that have serious upper and lower jaw problems, maxilla and mandible are arranged in three dimensions. Based on the maxillary rearrangement, mandibular sagittal and transverse positions are determined, and thus new occlusal plane is established. The object of this study is to evaluate the stability of the indiviual ideal occlusal plane based on the architectural and structural craniofacial analysis of Delaires. The subjects of this study were 48 patients who underwent two jaw surgeries, and they were equally divided into two groups, A and B. A group was operated with ideal occlusal plane and B group was not. Two groups were compared at the preoperative, immediate postoperative (average 4.3days), and long-term postoperative (average 1.3years) lateral cephalometric radiographs. The following results were obtained: 1. ANS was lower than that of PNS for both A and B after the surgery. That is, maxilla and mandible are rotated in posterior and superior direction. 2. Significances were found between $T_2$ and $T_3$ for both A and B are HRP-Me at vortical measurements, articular angle(p<0.01), gonial angle(p<0.01), and Mn. plane angle(p<0.05) at angular measurement. Mn. plane angle is increased at HRP-Me is decreased for both A and B. 3. There is no significance in skeletal stability aster the surgery between group A and B. 4. Horizontal movements of B and Pog by surgery have statistically significant inverse correlations with horizontal relapse of B and Pog, and vertical relapse of PNS, as well as Mn. Plane angle, and gonial angle after the surgery.

  • PDF

THE STDUY OF THE RELAPSE OF HARD AND SOFT TISSUE AFTER MAXILLARY PROTRACTION (상악골 전방견인 후 경조직과 연조직의 재발에 관한 연구)

  • Yang, Jun-Ho;Park, Soo-Byung;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.27 no.3 s.62
    • /
    • pp.373-389
    • /
    • 1997
  • The purpose of this stdudy was to evaluate the effect of maxillary protraction and the relapse of hard and soft tissue after maxillary protraction. For this study 29 patients who were treated with maxillary protractor and labiolingual archwire were selected. Their mean age was 9 years 4 months and mean treatment period was 8.5 months. Lateral cephalograms were taken at pretreatment, immediately after treatment and one to three months after removal of the maxillary protractor. They were traced on skeletodental and soft tissue structures based on Burstone's analysis and analyzed by Quick-Ceph Image Digitizing System(ORTHODONTIC PROCESSING). The mean and standard deviation between pretreatment and posttreatment and between posttreatment and retention period for each cephalometric variable were calculated. Student t-test was used to determine the statistical significance of the changes in each variable. Correlation coefficients between hard tissue and soft tissue were used to determine interrelationship. The results were as follows. 1. After maxillayy protraction, the maxilla and maxillary dentition moved antero-inferiorly, the mandibld and mandibular dentition moved postero-interiorly and palatal plane rotated antero-superiorly by $0.59^{\circ}$. 2. After maxillary protraction, the soft tissue of upper lip moved antero-interiorly with the movement of hard tissue but the antero-posterior position of lower lip was stable in spite of the change of hard tissue. The thickness of upper lip was decreased and that of lower lip was increased after maxillary Protraction. 3. During the retention period, the position of jaws was relatively stable but upper and lower anterior teeth and antero-superiorly rotated palatal plane relapsed to original position. 4. During the retention period, the soft tissue of lips was stable antero-posteriorly and moved mote inferiorly than posttreatment. 5. The correlation coefficients between the postion of upper and lower incisal edge and that position of lips were high, especially in horizontal change.

  • PDF

전치부 심미 임프란트에서 연조직 인상 채득법

  • Lee, Jong-Hyeok
    • The Journal of the Korean dental association
    • /
    • v.47 no.4
    • /
    • pp.206-210
    • /
    • 2009
  • 앞에서 임프란트 주변 연조직의 형태를 작업모형에서 재현하기 위한 몇가지 방법을 살펴 보았다. 심미성이 점차 강조되고 있는 추세에 비추어 단순하게 치아의 심미성 보다는 전반적으로 연조직과 경조직이 잘 조화되는 수복물이 요구되고 있다. 잘 만들어진 작업모형은 좀 더 심미적이고 안정된 결과를 얻을 수 있도록 도움이 될 것이다.

  • PDF

Three key factors for successful esthetic anterior implant restoration (성공적인 전치부 심미 임플란트를 위한 3가지 요소)

  • Lim, Pil
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.25 no.1
    • /
    • pp.35-49
    • /
    • 2016
  • With the increasing demand for aesthetic implant dentistry, the importance of implant restoration is emphasized not only in the functional aspect but also in the aesthetic aspect. The aesthetic restoration of dental implants in the anterior maxilla is a challenge for clinicians because it requires proper harmony in three following conditions; reconstruction of hard tissue, soft tissue, and aesthetic prosthesis. The soft tissue aesthetics are dependent upon the condition of the supporting hard tissue because the osseous structure provides a framework for the development of a healthy and aesthetic soft tissue interface. Therefore, the augmentation of hard tissue is a first step and especially, optimal 3-dimensional position of implant is the most important factor in aesthetic implant restoration. The management of soft tissue is a second step, and the final step is a restoration of harmonic prosthesis using provisional restoration with proper emergence profile. This clinical report describes the procedure of bone augmentation in labial dehiscence defect, Vascularized Interpositional Periosteal-Connective Tissue (VIP-CT) flap for aesthetic anterior soft tissue, and the importance of provisional restoration and impression taking stage with customized impression coping.

Preparation of Biodegradable Porous Calcium Metaphosphate Matrix (생분해성 다공질 Calcium Metaphosphate Matrix의 제조)

  • 이중환;김석영
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.449-454
    • /
    • 1998
  • It is well known that new tissue or blood vessel is grown into a porous calcium phosphate ceramics used as a bone graft substitute due to their excellent biocompatibility. In this study, the most chemically stable porous $\beta$-crystalline form in various forms of calcium metaphosphate, Ca(PO$_3$)$_2$is prepared by the controlled thermolysis of monocalcium phosphate, Ca(H$_2$PO$_4$)$_2$.The diameter of cylindrical pores formed during cooling was controlled by a holding time at the melting point of a monocalcium phosphate and by the change of a crystallization temperature, to obtain the most appropriate size (about 200$\mu$m) of pores for the application of bone substitutes and matricuts. It was observed that the increasing holding time at the melting point of monocalcium phosphate results in the decreases of cylindrical pore sizes.

  • PDF

Full mouth rehabilitation of a panfacial fracture patient with bilateral condylar fracture (다발성 안면골절환자의 교합회복 증례)

  • Park, Go-Woon;Cha, Min-Sang;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.159-169
    • /
    • 2014
  • Panfacial fractures require complex multidisciplinary approaches for treatment. Functional stability of bilateral condylar-disc complex should be the goal of the treatment. A patient with complex clinical panfacial fractures, including a bilateral condylar fractures visited our clinic. Facial asymmetry, insufficient vertical space and multiple missing teeth of the patient were major problems. Closed reduction and splint treatment were tried for stable condylar position. A functional and esthetic rehabilitation was accomplished by using implants and full mouth rehabilitaion. Potential possibilities of unstable occlusion should be prevented with night guard and periodic occlusal adjustment.

Esthetic complete denture fabrication utilizing Biofunctional Prosthetic System (BPS) (Biofunctional Prosthetic System(BPS) 를 이용한 심미 총의치 제작)

  • Noh, Kwantae
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.24 no.1
    • /
    • pp.68-74
    • /
    • 2015
  • The growing of healthy aged edentulous peoples in these days increases the demands of denture which is excellent in function and aesthetic. The Biofunctional Prosthetic System(BPS) is being introduced as a curriculum in a large number of schools in the United States, Europe and Japan. Each stages of BPS are standardized and systematized, on this account BPS is the system that even less experienced clinicians is able to produce highly satisfactory denture for patients. Additionally, the combination of BPS and suction mechanism of mandibular complete denture would make it possible to produce stabilized mandibular denture during oral function. The purpose of this article is to describe a process of producing fuctionally and aesthetically outstanding denture by using BPS combined with mandibular suction mechanism.

티타늄 임플란트와 수산화아파타이트 사이의 접착력 향상을 위한 Yttria-stabilized Zirconia Buffer Layer에 관한 연구

  • Park, Hyeong-Seok;Gang, Seong-Geun;Lee, Won-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.386-386
    • /
    • 2010
  • 최근 널리 보급되고 있는 치과용 임플란트는 티타늄(Ti) 또는 티타늄 합금(Ti-6Al-4V) 보철과 크라운을 연결하여 사용하고 있다. 티타늄은 생체 친화성이 우수하나, 생체 활성도가 없어 치유기간이 긴 단점이 있다. 이를 보완하기 위해 인체 경조직과 유사한 수산화아파타이트(hydroxyapatite, $Ca_{10}(PO_4)_6(OH)_2)$를 티타늄 임플란트 표면에 코팅하는 방법이 연구되고 있으나 수산화아파타이트 코팅은 티타늄과의 접착성이 나쁘기 때문에 시술 및 사용과정에서 코팅층이 임플란트로부터 박리되는 문제점이 있다. 본 연구에서는 티타늄과 수산화아파타이트 사이에서 접착력을 향상시키는 buffer layer로서 지르코니아(8YSZ, 8mol% Yttria-stabilized zirconia)를 연구하였다. 지르코니아는 고온에서 안정하며, 티타늄 합금과 수산화아파타이트 사이의 반응을 방지하며, 박막밀도와 기계적 강도가 좋은 생체세라믹스이다. 지르코니아 박막을 펄스 레이저 증착법을 이용하여 증착 온도 $600^{\circ}C$, 레이저 fluence $2\;J/cm^2$에서 산소($O_2$) 분압을 바꿔 가며 증착하였다. 그 위에 수산화아파타이트 박막을 역시 펄스 레이저 증착법으로 증착하였다. Scratch test와 Pull-off test를 통해 접착력을 평가한 결과 지르코니아 buffer layer 삽입에 의해 티타늄 합금과 수산화아파타이트 사이의 접착력이 향상되었음을 확인하였다. 또한 산소분압이 박막의 특성 및 접착력에 미치는 영향을 고찰하였다.

  • PDF

Implant-supported fixed prosthesis in patient with severe defects using staged GBR via 2-step augmentations: A case report (심한 결손부의 단계적 골증대술을 통한 임플란트 지지 고정성 보철 수복 증례 보고)

  • Oh, SaeEun;Jun, Ji Hoon;Park, YoungBum
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.382-394
    • /
    • 2022
  • The treatment of patients with severe periodontitis should be proceeded step-bystep through an accurate diagnosis of each patients' individual tooth and with a strategic treatment plan. Implant-supported fixed prosthetic restoration has the advantage of high patient satisfaction and stable vertical dimension compared to the removable partial denture. However, multiple teeth defect areas lacking hard tissue may be disadvantageous in aesthetic failure and longer treatment time. In addition, it takes a certain period of time to manufacture and install a conventional fixed prosthesis, and during this process, the provisional prosthesis must satisfy the mechanical, biological, and aesthetic requirements of teeth. The purpose of this article is to describe the fabrication of implant-supported fixed prosthesis through a step-by-step approach in a partially edentulous patient.

The experimental study of early loading on the Miniplate in the beagle dog (성견의 하악골에 식립된 Miniplate에 가한 조기 부하의 영향에 관한 실험적 연구)

  • Chung, Yong-Koo;Lee, Young-Jun;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.33 no.4 s.99
    • /
    • pp.307-317
    • /
    • 2003
  • Conventional osseointegrated titanium implants have many limitations; large size, limited location for placement of the implant, severity of the surgery, discomfort of initial healing, difficulty of oral hygiene and uncontrollable force direction. Recently titanium miniscrew and miniplate have been used for an alternative to conventional dental implant. But in relation to miniplate, miniscrew has disadvantages in that more potential inflammation, light orthodontic force application and limited orthodontic application. This study was conducted to evaluate the effectiveness of miniplate by observing the reactions of peri-implant tissues to early orthodontic and orthopedic loading of titanium miniplate. In four adult beagle dogs 10 miniplates were inserted into the alveolar bone using 20 osseointegrated titanium screws. 4 miniplates were placed in two dogs(dogA, B) and 6 miniplates in two dogs(dogC, D). In dogA, B miniplates were loaded with 200gm of force immediately after placement for 15 weeks. In dogc, D, miniplates were loaded with 400gm of force immediately after placement for 8 weeks. Miniplates of dogA were removed, dogA was healed for 4 weeks, and the area which was removed of miniscrew was examined. Following an observation period, the miniplates including miniscrews and the surrounding bone of dogB and dogC, D were removed, respectively. Undecalcified section along the long axis of miniscrews were made and the degree of osseointegration was examined under the light microscope. The results were as follows. 1. In the histologic features there was direct contact between bone and miniscrew in all groups except one, dogC control group. The loaded miniscrew demonstrated only a slight increase of the osseous proximaty when compared with unloaded miniscrew 2. There was no significant difference of the osseointegration of Peri-miniscrew surface between dogB and dogC, D. But dogB showed slightly more increased bone apposition than dogC, D 3. The gingiva overlapping the miniplate and miniscrew showed no inflammatory sign in clinical and histological aspects. 4. The impaled hard and soft tissues at the area which was removed of miniscrews showed good healing without inflammatory reaction. 5. The mobility showed slight increase in un-loaded miniplate but that was insignificant. Based on the results of this study, miniplate(C-tube) can be used as a firm osseous orthodontic and orthopedic anchorage unit immediately after insertion.