• Title/Summary/Keyword: 경서(經書)

Search Result 108, Processing Time 0.027 seconds

Numerical Analysis of Wasted Heat Recovery Ventilator for Improving the Heat Exchange Efficiency (폐열회수 환기장치의 열교환 효율 개선을 위한 전산수치해석)

  • Kim, Hyun-Il;Kim, Jae-Sung;Park, Chul-Woo;Park, Kyung-Seo
    • Korean Journal of Computational Design and Engineering
    • /
    • v.17 no.1
    • /
    • pp.54-61
    • /
    • 2012
  • In this paper, we performed numerical analysis to improve the heat exchange efficiency of wasted heat recovery ventilator which has a delivery and a exhaustion fan. One of the most important design factors that affect the efficiency of heat exchange is uniform counter-flow between inbound and outbound air flows. We had simulated several types of porous plates which were installed at air intake area. With plate having 45 degrees of installation angle and 15 mm diameter holes which are uniformly arranged, we can generate a uniform air flows at the area of porous media where inbound and outbound air flows are cross over. In addition, we installed a duct to reduce vortex flows at the outlet and to discharge exhaust airs rapidly. By using the proposed numerical assessment, we expect the improvement of the heat exchange efficiency of ventilator.

Performance Improvement of Induction Motor in Voltage Shortage State (전압 부족 상태 시 유도 전동기 성능 개선)

  • Kim, Hye-Seung;Kim, Jeong-Ha;Hong, Chan-Ook;Kim, Kyung-Seo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.466-471
    • /
    • 2009
  • The vector control algorithm has come to be used as induction motor for high performance torque and response improvement. This paper deals with new control algorithm which improves the performance of the rotor flux control by combining the conventional current controller with the flux controller and the hysteresis controller. In voltage shortage condition, proposed algorithm shows that the response and the stability can be improved both in the simulation results and in the experimental results.

Induction motor sensor less speed control by stator flux oriented method (고정자 자속 기준 제어 방식에 의한 속도검출기 없는 유도전동기 속도 제어 시스템)

  • Park, Min-Ho;Kim, Kyoung-Seo;Kim, Heui-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.268-272
    • /
    • 1989
  • To avoid the use of position sensor or flux sensor in a field oriented induction machine drive system, the terminal quantities are often used to estimate the rotor flux. Since the estimation involves the leakage inductance of the machine, the performance of such systems is sensitive to the variations of leakage. Since estimation of the stator flux is independent of the leakage, the steady state performance of the stator flux oriented system is insensitive to the leakage inductance. In this paper, the torque response of stator flux oriented system is compared to that of rotor flux oriented system by digital simulation. And induction motor sensor less speed control by stator flux oriented method is developed. The performance of the speed estimation is showed by digital simulation.

  • PDF

The Method of construction for YoungJong Grand Bridge (영종도 연육교 적용 공법)

  • Shin HyunYang
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.239-253
    • /
    • 2000
  • 영종대교는 2000년대 수도권 항공수요에 대비하여 영종도와 용유도 일원의 간석지에 건설되어, 인천국제공항과 인천 경서동을 연결하는 총연장 4,420m의 해상교량으로 현수교 3경간(550m), Truss교 18경간 (2,250m), 강상형교 27경간(1.620m)로 구성되어 있다. 영종대교는 10개 차선, 철도 2개 차선의 교량으로 건설된다. 교량이 건설되는 해역은 10,000ton급 선박의 통행이 가능하도록 교하공간 35m의 현수교를 계획 하였으며 경제성을 고려하여 Cable을 보강형에 정착시켰다. 미관을 고려한 경간 분할에 따른 교량의 부상을 방지하기 위하여 단부교각에 Link 구조를 설치하고 접속교를 Counterweight로 이용하였으며 Cable 장력이 저감되도록 Sag비를 1/5(=f/1)로 설정하였다.

  • PDF

Least Cost Generation Expansion Planning Methodology and Generation Cost (전원개발계획(電源開發計劃)에서의 비용최소화(費用最小化)와 발전원가(發電原價))

  • Chung, Do-Young;Park, Kyung-Suh;Park, Jong-Bai
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.106-109
    • /
    • 1992
  • This paper Introduces the concept of the generation cost of generating utilities and its calculation methods. Also, the economic evaluation method using generation cost which is called as a screening curve method will be presented along with the benefits and disadvantages of this concept. Next, the least-cost electric utility planning techniques which is used very widely in many countries will be Introduced In comparison with screening curve method. In this aspects, the optimal dynamic mix can be determined as a result. By comparing these two concepts, we will get the concrete concept why the economic evaluation method using generation cost can not be used for the future generation expansion planning.

  • PDF

Experiment and Numerical Study on Thermal Characteristics of UV-NIL Process Considering the Cure Kinetics of Photo-polymer (레진의 경화 반응을 고려한 UV-NIL공정의 열특성에 관한 실험 및 수치해석 연구)

  • Kim, Woo-Song;Park, Gyeong-Seo;Nam, Jin-Hyun;Yim, Hong-Jae;Jang, Si-Yeol;Lee, Kee-Sung;Jeong, Jay;Lim, Si-Hyeong;Shin, Dong-Hoon
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1847-1850
    • /
    • 2008
  • The process conditions during ultraviolet nanoimprint lithography (UV-NIL) process such as temperature, stamping pressure, UV irradiation, etc. are effective factors for successful imprinting of complex and fine patterns. In this study, the effects of aluminum mold on the thermal characteristics of UV-NIL process were investigated through imprinting experiments and numerical simulations. The temperature of polymer resin on mold was measured to study thermal characteristics during UV curing. From the experimental and numerical results, the importance of curing reaction control for UV-NIL process was discussed for deformation characteristics.

  • PDF

Auto-measurement of Motor Parameters for Sensorless Vector Control of Induction Motors (센서리스 벡터제어를 위한 유도전동기 상수의 자동 측정)

  • 김경서;강기호
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.6
    • /
    • pp.552-559
    • /
    • 2000
  • Most of the sensorless vector control methods use the equivalent circuit of induction motors. Therefore parameter auto-measurement of drive motor is essential function in commercial sensorless vector control inverters. The accuracy of motor parameter measurement greatly affects the performance of sensorless vector control. In this paper limitations of conventional measurement methods are examined, and new measurement methods are proposed to solve those limitations.

  • PDF

A Study on Parameter On-line Estimation of Induction Motor using MRAS (MRAS를 이용한 유도전동기의 파라미터 온라인 추정에 관한 연구)

  • Yoon In-Sic;Byun Sung-Hoon;Kim Kyung-Seo
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.188-191
    • /
    • 2002
  • This paper presents a method for on-line estimation of rotor time constant of induction motor. The proposed method applies a model reference adaptive system(MRAS) using rotor flux vector. The MRAS consists of two independent observers to estimate the rotor flux vector; one based on voltage equations of rotor flux vector, the other based on current equations of them. The MRAS utilizes concept of auxiliary variables to normalize observer output and decrease high-frequency components of its input. Experimental results verify the validity and usefulness of proposed method

  • PDF

LSMV Multi-level Inverter development and Application (LSMV 고압인버터 개발 및 현장 적용)

  • Kim, Hyo-Jin;Na, Seung-Ho;Kim, Kyeon-Seo
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.311-313
    • /
    • 2010
  • 에너지 고갈에 따른 대체 에너지 확립이 화두가 되고 있으며 대체 에너지에 대한 급속한 연구가 진행되고 있다. 이러한 연구가 중요함은 물론 현재, 사용하고 있는 에너지를 얼마나 효율적으로 쓸 것인가에 대해서 고민하고 있다. 기존 산업 시설에서는 에너지를 절감하기 위한 방법으로 저압의 산업 시설에서는 인버터를 적용하여 적게는 10%에서 70%까지에 에너지를 절감효과를 보고 있다. 하지만 고압의 대용량 설비 시설에서는 인버터가 적용된 비율이 채 10%가 넘지 않는다. 이러한 대용량 설비 기계 사용처에서 최근 에너지를 절감하기 방안으로 고압인버터를 적용하기 시작하여, 고압 인버터의 수요가 급속히 늘어나는 추세이다. 이러한 시장 동향을 파악하여 LSIS의 저압인버터의 기술을 바탕으로한 LSMV 고압인버터를 출시하게 되었다. 본 기술서에는 LSMV 시리즈의 특징과 산업 현장에 적용된 사례에 대해서 기술하고자 한다.

  • PDF

Development of Continuous Process Control System Using Torque Controlled Vector Inverter (벡터 인버터의 토크 제어를 이용한 연속공정 제어 시스템 개발)

  • Byun, S.H.;Cheong, J.Y.;Hong, C.O.;Kim, K.S.
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.314-315
    • /
    • 2010
  • This paper presents the design and development of Web control algorithm of continuous process control system using torque controlled vector inverter. Web algorithm used tension control with the tension sensor, and it is to calculate diameter of motor speed with maintain Web tension. The performance of Web control in this paper is verified by experiment.

  • PDF