• Title/Summary/Keyword: 경사응답

Search Result 81, Processing Time 0.027 seconds

A P-Parallel Controller Design based on P-Control Ramp Response in Machine Tool (비례제어 경사응답에 기반한 공작기계의 비례-병렬 제어기 설계)

  • Gil, Hyeong-Gyeun;Lee, Gun-Bok
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.780-785
    • /
    • 2004
  • The work presented here deals with controller design by graphical method based on proportional control ramp response. The design aims at the improvement of transient response, disturbance rejection capability, steady-state error reduction with stability preservation. The first step is to generate tracking-error curve with proportional control only and decide the added error signal shape on the error curve. The effectiveness of the proposed controller is confirmed through the simulation and experiment.

  • PDF

Long Term Monitoring of Dynamic Characteristics of a Jacket-Type Offshore Structure Using Dynamic Tilt Responses and Tidal Effects on Modal Properties (동적 경사 응답을 이용한 재킷식 해양구조물의 장기 동특성 모니터링 및 조류 영향 분석)

  • Yi, Jin-Hak;Park, Jin-Soon;Han, Sang-Hun;Lee, Kwang-Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.2A
    • /
    • pp.97-108
    • /
    • 2012
  • Dynamic responses were measured using long-term monitoring system for Uldolmok tidal current pilot power plant which is one of jacket-type offshore structures. Among the dynamic quantities, the tilt angle was chosen because the low frequency response components can be precisely measured by dynamic tiltmeter, and the natural frequencies and modal damping ratio were successfully identified using proposed LS-FDD (least squared frequency domain decomposition) method. And the effects of tidal height and tidal current velocity on the variation of natural frequencies and modal damping ratios were investigated in time and frequency domain. Also the non-parametric models were tested to model the relationship between tidal conditions and modal properties such as natural frequencies and damping ratios.

Evaluation of Seismic Performance of Pile-supported Wharves with Batter Piles through Response Spectrum Analysis (응답스펙트럼해석을 통한 경사말뚝이 설치된 잔교식 안벽의 내진성능 평가)

  • Yun, Jung-Won;Han, Jin-Tae;Kim, JongKwan
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.12
    • /
    • pp.57-71
    • /
    • 2021
  • The pile-supported wharf is the port structure in which the upper deck is supported by piles or columns. By installing batter piles in this structure, horizontal load such as earthquake loads can be partially delivered as axial forces. The codes suggests using the response spectrum analysis as a preliminary design method for seismic design of pile-supported wharf, and suggests modeling the piles using virtual fixed points or soil spring methods for this analysis. Recently, several studies have been conducted on pile-supported wharves composed of vertical piles to derive a modeling method that appropriately simulates the dynamic response of structures during response spectrum analysis. However, studies related to the response spectrum analysis of pile-supported wharves with batter piles are insufficient so far. Therefore, this study performed the dynamic centrifuge model test and response spectrum analysis to evaluate the seismic performance according to the modeling method of pile-supported wharves with batter piles. As a result of test and analysis, it is confirmed that modeling using the Terzaghi (1955) constant of horizontal subgrade reaction (nh) most appropriately simulates the actual response in the case of the pile-supported wharf with batter piles.

Analyses of Spectral IP Responses over 20-Degree Dipping Structure (20도 경사구조에 대한 스펙트럴 IP응답의 해석)

  • Kim, Hee Joon
    • Economic and Environmental Geology
    • /
    • v.19 no.3
    • /
    • pp.219-224
    • /
    • 1986
  • Spectral induced polarization (IP) responses for 20-degree dipping body are obtained by both numerical and scale models. The IP responses for the dipping body vary not only with current frequencies but also with resistivity ratios between the body and the surrounding medium. If the ion concentration related to polarizable reaction is constant, the resistivity of polarizable body depends only on the current frequency. This implies that the IP responses to the resistivity ratio are qualitatively equivalent to those to the current frequency. The numerical results with wide-range resistivity ratios, therefore, can be used as standard curves for the interpretation of spectral IP data.

  • PDF

Hybrid Peak-Valley Current Band Control for PSFB Converter Without Response Delay (응답지연 없는 PSFB 컨버터 하이브리드 피크-밸리 전류밴드 제어 기법)

  • Ko, Jae Hak;Baek, Seung-Woo;Kim, Hag-Wone;Cho, Kwan-Yuhl
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.23-25
    • /
    • 2019
  • PSFB 컨버터(Phase Shift Full Bridge converter)는 다양한 전원장치에 응용되고 있다. 또한 빠른 응답과 1차 측 전류 피크의 불 평형을 방지하기 위해 PCMC(Peak Current Mode Control)를 적용해야 한다. 하지만 PCMC는 유효 시비율이 0.5 이상 일 때 저주파 발진이 일어나기 때문에 경사 보상 기법을 이용해 발진을 막아야 한다. 일반적으로 경사보상 기울기는 최댓값을 사용하기 때문에 전류 명령이 과 보상되며, 무효시비율 구간을 고려하지 않기 때문에 응답속도가 지연 되는 문제가 있다. 따라서 본 논문에서는 무효 시비율 구간을 고려한 하이브리드 피크-밸리 전류 밴드 제어를 통해 BUCK 컨버터와 동일한 응답 특성을 가지는 PSFB 컨버터 제어 기법을 제안한다. 제안하는 기법은 PSIM 시뮬레이션을 통해 검증되었다.

  • PDF

Transient Response of a Crack in a Functionally Graded Piezoelectric Strip between Two Dissimilar Piezoelectric Strip (두 개의 서로 다른 압전재료층 사이의 기능경사압전재료 접합층 내부 균열에 대한 과도응답 해석)

  • Shin, Jeong Woo;Lee, Young-Shin;Kim, Sung Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.206-213
    • /
    • 2013
  • Transient response of a crack in a functionally graded piezoelectric material (FGPM) interface layer between two dissimilar homogeneous piezoelectric layers under anti-plane shear is analyzed using integral transform approaches. The properties of the FGPM layer vary continuously along the thickness. Laplace and Fourier transforms are used to reduce the problem to two sets of dual integral equations, which are then expressed to the Fredholm integral equations of the second kind. Numerical values on the dynamic energy release rate (DERR) are presented for the FGPM to show the effects on electric loading, gradient of the material properties, and thickness of the layers. Computed results yield following conclusions: (a) the DERR increases with the increase of the gradient of the material properties of the FGPM layer; (b) certain direction and magnitude of the electric impact loading impedes crack extension; (c) increase of the thickness of the FGPM layer and the homogeneous piezoelectric layer which has larger material properties than those of the crack plane are beneficial to increase of the resistance of transient fracture of the FGPM layer.

  • PDF

Analyses of Dipole-Dipole IP Responses over Dipping Structures (경사구조에 대한 쌍극자 IP 응답의 해석)

  • Kim, Hee Joon
    • Economic and Environmental Geology
    • /
    • v.17 no.1
    • /
    • pp.49-55
    • /
    • 1984
  • This paper describes three-dimensional (3-D) standard curves for conductive dipping buried bodies in induced polarization (IP) method. Dipole-dipole IP responses for the dipping bodies are calculated by the numerical modeling technique using an integral equation solution. Dip angles of the bodies are 0, 20, 45, 70 and 90 degrees, respectively. The horizontal (0-degree dip) and vertical (90-degree dip) bodies produce symmetrical patterns of IP responses. The dipping bodies of 20, 45 and 70 degrees, however, produce asymmertical patterns, with the highest IP contours dipping in the direction opposite to the bodies in pseudo-sections. The most remarkable asymmetrical pattern appears in the model of 20-degree dip. It is difficult to distinguish the body of 70-degree dip from that of 90-degree dip on the basis of dipole-dipole IP data. The IP pattern in pseudo-sections varies when the line moves away from the center of the body along strike, with the anomaly deeper and smaller in amplitude. IP maps seem to be more useful than IP pseudo-sections in predicting the location of target.

  • PDF

Development of tension control systems for warp let-off and take-up (경사송출 및 권취장력제어장치의 개발)

  • Huh, You;Lee, Jae-Won;Lee, Suck-Gyu
    • Journal of the KSME
    • /
    • v.35 no.1
    • /
    • pp.46-52
    • /
    • 1995
  • 지금에 이르기까지 직기개발을 위한 주안점은 새로운 위입시스템(water-jet, air-jet)의 개발과 지속적인 직기의 생산속도증가에 대한 각 위입요소들의 최적동작을 위한 기계요소의 개발에 주 어져 있었다. 반면에 위입동작과 직접 연관되지 않는 직기의 구성요소들은 증가하는 위입속도에 따라 각 기능의 안정성과 동작의 정확성에 대한 요구가 점차 증가되었으며, 특히 경사장력 및 이에 작용하는 기계요소들에 대한 기술적 요구수준은 과거의 북직기에서의 경우에 비교될 수 없을 정도의 한계적 상황을 만족시켜야 하게 되었다. 경사송출의 경우, 위사 1가닥이 공급될 때 마다 직물권취에대응하여 경사장력을 일정하게 유지하며, 경사의 일정 길이를 정확히 공급하여야 하기 때문에 고속 무북직기에서는 빠른 응답속도와 안정된 동작을 행할 수 있는 경사송출기구 및 장력제어시스템의 성능이 직기성능에 가장 큰 영향을 미치게 되었으며 지금까지 사용되어온 기계적 송출장치로는 한계적 기술요건을 만족시킬 수 없게 되었다. 이에 따라 근자에 이르러 경사장력제어형 장력송출장치의 응용이 크게 대두되고 있다. 이 글에서는 이러한 새로운 형태의 송출장치의 개발상황과 경사장력제어에서 해결되지 못한 문제점에 대하여 다루어 보고자 한다.

  • PDF

The Analysis of Hydrological Response Structure Based on Spatial Correlation of Extracted Geomorphic Variables by Using DEM (DEM에 의해 추출된 지형인자의 공간상관성을 기반으로 한 수문학적 응답구조의 해석)

  • Kim, Joo-Cheol;Choi, Yong-Joon;Kim, Jae-Han
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.18 no.2
    • /
    • pp.69-78
    • /
    • 2010
  • The hydrological-geomorphic character is closely related with runoff in basin. A development of GIS greatly helps investigating about mechanism between theirs. We analyze local slope and hillslope length which are related with hydrological response. But variation of these geomorphic variables has very wide range at each pixel. So there's a limit as to use directly. Therefore we investigate a relation between hydrological response and distributed geomorphic variables according to statistical character of distributed map considering spatial correlation. As a result, the local slope affects peak discharge, and the hillslope length affects peak discharge and time, mean and variance of hydrological response. Henceforth these hydrological-geomorphic analyze methods can be improved that hydrology response is directly analogized with DEM data.

Study on the Applicability of Standard Design Response Spectrum Analysis Method for Pile-type Mooring Facilities (말뚝식 계류시설의 표준설계응답스펙트럼 해석법 적용성 연구)

  • Oh, Jeong-Keun;Jeong, Yeong-Seok;Kwon, Min-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.5
    • /
    • pp.27-36
    • /
    • 2020
  • The purpose of this paper is to study on the applicability of the standard design response spectrum from the response spectrum analysis method, mainly applied to pile mooring facilities. To this end, after performing the ProShake 1-dimensional site response considering various geological conditions, the current standard design response spectrum was compared, and the ground-pile model in time history and two-dimensional site response analysis using Abaqus were performed to analyze the dynamic behavior of the ground-pile and to examine the selection method of the reference surface of the response spectrum on the installed slope, respectively. As a result, it was confirmed that no problems were found in the applicability of the current standard design response spectrum and no improvements are needed as well when considering the characteristics of the ground-pile dynamic behavior and the slope of the pile mooring facility.