• Title/Summary/Keyword: 경사에코

Search Result 49, Processing Time 0.026 seconds

Clinical Analysis of the Prognosis of the Patients with Cerebral Diffuse Axonal Injuries, Based on Gradient-echo MR Imaging (경사에코자기공명영상을 이용한 뇌미만성 축삭 손상 환자의 예후 분석)

  • Kim, Hyoung Jong;Park, In Sung;Kim, Jae Hyoung;Kim, Ki Jeong;Hwang, Soo Hyun;Kim, Eun-Sang;Jung, Jin-Myung;Han, Jong Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.2
    • /
    • pp.168-172
    • /
    • 2001
  • Objective : The authors have studied the clinical outcome of patients with diffuse axonal injuries(DAI) to evaluate the prognostic value of gradient-echo MR imaging findings. Materials and Methods : From March 1995 to March 1998, there were nineteen patients with DAI whose initial Glasgow coma scales were eight or less. Authors divided them into two groups according to Glasgow outcome scales ; those patients with GOS 3 or less(group A ; 9) and those with 4 or more(group B ; 10). We subdivided the lesions as superficial and deep lesion, and analyzed the numbers, anatomical loci of the lesions on the gradient echo images of each group. Results : Mean numbers of the lesions were 15 per case in group A(135/9) and 10 in group B(100/10). The common loci involved in DAI were cerebral cortex, brain stem, and corpus callosum. Cortical lesions were 31.1% in group A(42/135) and 47% in group B(47/100). Brain stem lesions were 25.9%(35/135) and 15%(15/100) each. Callosal lesions were 31.1%(26/135) and 13%(13/100) each. The frequency of callosal and brain stem lesions was significantly different between two groups(p<0.05). We divided callosal lesions as genu, body, and splenium and body lesions as anterior, middle, posterior, but no significant topographical difference of lesions was observed between two groups. Deep lesions were observed more frequently in group A(58.5%, 79/135) than group B(36%, 36/100). Conclusion : The poor outcome group showed more numbers of lesion and more frequent involvement of brain stem and corpus callosum than favorable outcome group. Gradient-echo MR imaging seems to have predictive value for clinical outcome in patients with DAI.

  • PDF

Susceptibility-Weighted Imaging as a Distinctive Imaging Technique for Providing Complementary Information for Precise Diagnosis of Neurologic Disorder (신경계 질환에 관한 정확한 진단을 위해 다양한 보완 정보를 제공하는 독특한 영상 기법으로서의 자기화율 강조 영상)

  • Byeong-Uk Jeon;In Kyu Yu;Tae Kun Kim;Ha Youn Kim;Seungbae Hwang
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.99-115
    • /
    • 2021
  • Various sequences have been developed for MRI to aid in the radiologic diagnosis. Among the various MR sequences, susceptibility-weighted imaging (SWI) is a high-spatial-resolution, three-dimensional gradient-echo MR sequence, which is very sensitive in detecting deoxyhemoglobin, ferritin, hemosiderin, and bone minerals through local magnetic field distortion. In this regard, SWI has been used for the diagnosis and treatment of various neurologic disorders, and the improved image quality has enabled to acquire more useful information for radiologists. Here, we explain the principle of various signals on SWI arising in neurological disorders and provide a retrospective review of many cases of clinically or pathologically proven disease or components with distinctive imaging features of various neurological diseases. Additionally, we outline a short and condensed overview of principles of SWI in relation to neurological disorders and describe various cases with characteristic imaging features on SWI. There are many different types diseases involving the brain parenchyma, and they have distinct SWI features. SWI is an effective imaging tool that provides complementary information for the diagnosis of various diseases.

The Synthesis and MR Properties of New Macromolecular MR Contrast Agent (새로운 거대분자 MR 조영제의 합성 및 MR 특성에 관한 연구)

  • 장용민;장영환;황문정;박현정;전경녀;이종민;배경수;강봉석
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.35-40
    • /
    • 2002
  • Purpose : To evaluate the NMR relaxation properties and imaging characteristics of tissue-specificity for a newly developed macromolecular MR agent. Materials and methods : Phthalocyanine (PC) was chelated with paramagnetic ion, Mn.2.01g (5.2 mmol) of Phthalocyanine was mixed with 0.37g (1.4 mmol) of Mn chloride at $310^{\circ}C$ for 36 hours and then purified by chromatography (CHC13/CH3OH 98/2 v/v, Rf, 0.76) to obtain 1.04g (46%) of MnPC (molecular weight= 2000d). The $T1}T2$ relaxivity of MnPC was measured in 1.5T(64 MHz) MR using 0.1 mM MnPC. The MR image characteristics of MnPC was evaluated using spin-echo (TR/TE=500/14 msec) and gradient-echo (FLASH) (TR/TE=80/4 msec, flip angle=60) techniques in 1.57 MR scanner. The images of rabbit liver were obtained every 10 minutes up to 4 hours. To study the effect of concentration on image, 20 mM, 50 mM, 100 mM of MnPC were tested. Results : The relaxivities of MnPC at 1.5T(64MHz) were Rl=7.28 $mM^{-1}S^{-1},{\;}R2=55.56mM^{-1}S^{-1}$. Compared to the values of Gd-DTPA (Rl[=4.8 $mM^{-1}S^{-1})$], R2[=5.2 $mM^{-1}S^{-1}])$]), both T1/T2 relaxivities of MnPC were higher than those of Gd-DTPA. For both of SE and FLASH techniques, the contrast enhancement reached maximum at 10 minutes after bolus injection and the enhancement continued for more than 2 hours. When compared with small molecular weight liver agents such as Gd-EOB-DTPA, Gd-BOPTA and MnDPDP, MnPC was characterized by more prolonged enhancement time. The time course of MR images also revealed biliary excretion of MnPC. Conclusion : We developed a new macromolecular MR agent, MnPC. The relaxivities of MnPC were higher than those of small molecular weight Gd-chelate. Hepatic uptake and biliary excretion of MnPC suggests that this agent is a new liver-specific MR agent.

  • PDF

Serial MR Imaging of Magnetically Labeled Humen Umbilical Vein Endothelial Cells in Acute Renal Failure Rat Model (급성 신부전 쥐 모델에서 자기 표지된 인간 제대정맥 내피세포의 연속 자기공명영상)

  • Lee, Sun Joo;Lee, Sang Yong;Kang, Kyung Pyo;Kim, Won;Park, Sung Kwang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.3
    • /
    • pp.181-191
    • /
    • 2013
  • Purpose : To evaluate the usefulness of in vivo magnetic resonance (MR) imaging for tracking intravenously injected superparamagnetic iron oxide (SPIO)-labeled human umbilical vein endothelial cells (HUVECs) in an acute renal failure (ARF) rat model. Materials and Methods: HUVECs were labeled with SPIO and poly-L-lysine (PLL) complex. Relaxation rates at 1.5-T MR, cell viability, and labeling stability were assessed. HUVECs were injected into the tail vein of ARF rats (labeled cells in 10 rats, unlabeled cells in 2 rats). Follow-up serial $T2^*$-weighted gradient-echo MR imaging was performed at 1, 3, 5 and 7 days after injection, and the MR findings were compared with histologic findings. Results: There was an average of $98.4{\pm}2.4%$ Prussian blue stain-positive cells after labeling with SPIOPLL complex. Relaxation rates ($R2^*$) of all cultured HUVECs at day 3 and 5 were not markedly decreased compared with that at day 1. The stability of SPIO in HUVECs was maintained during the proliferation of HUVECs in culture media. In the presence of left unilateral renal artery ischemia, $T2^*$-weighted MR imaging performed 1 day after the intravenous injection of labeled HUVECs revealed a significant signal intensity (SI) loss exclusively in the left renal outer medulla regions, but not in the right kidney. The MR imaging findings at days 3, 5 and 7 after intravenous injection of HUVECs showed a SI loss in the outer medulla regions of the ischemically injured kidney, but the SI progressively recovered with time and the right kidney did not have a significant change in SI in the same period. Upon histologic analysis, the SI loss on MR images was correspondent to the presence of Prussian blue stained cells, primarily in the renal outer medulla. Conclusion: MR imaging appears to be useful for in vivo monitoring of intravenously injected SPIO-labeled HUVECs in an ischemically injured rat kidney.

The Comparative Imaging Study on Mn-phthalocyanine and Mangafodipir trisodium in Experimental VX2 Animal Model (실험적으로 유발시킨 VX2 동물모델에서의 Mn-phthalocyanine과 Mangafodipir trisodium의 비교영상)

  • Park Hyun-Jeong;Ko Sung-Min;Kim Yong-Sun;Chang Yongmin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.1
    • /
    • pp.32-41
    • /
    • 2004
  • Purpose : To measure the NMR relaxation properties of MnPC, to observe the characteristics of liver enhancement patterns on MR images in experimentally implanted rabbit VX2 tumor model, and to estimate the possibility of tissue specific contrast agent for MnPC in comparison with the hepatobiliary agent. Materials and Methods : Phthalocyanine (PC) was chelated with paramagnetic ions, manganese (Mn). 2.01 g (5.2 mmol) of phthalocyanine was mixed with 0.37 g (1.4 nlmol) of Mn chloride at $310^{\circ}C$ for 36 hours and then purified by chromatography ($CHCl_3:\;CH_3OH=98:2$, volume ratio) to obtain 1.04 g $(46\%)$ of MnPC (molecular weight = 2000 daltons). The T1/T2 relaxivity (R1/R2) for MnPC were determined at a 1.5 T (64 MHz) MR spectrometer. VX2 tumor model was experimentally implanted in the liver parenchyma of rabbits. All MR studies were performed on 1.5 T. The human extremity radio frequency coil of a bird cage type was employed. MR images were acquired at 17 to 24 days after VX2 carcinoma implantation.4 mmol/kg MnPC and 0.01 mmol/kg Mn-DPDP were injected via the ear vein of rabbits. T1-weighted images were obtained with spin-echo (TR/TE=516/14 msec) and fast multiplanar spoiled gradient recalled (TR/TE : 80/4 msec, $60^{\circ}$ flip angle) pulse sequence. Fast spin-echo (TR/TE=1200/85 msec) was used to obtain the T2-weighted images. Results : The value of T1/T2 relaxivity (R1/R2) of MnPC was $7.28\;mM^{-1}S^{-1}$ and $55.56\;mM^{-1}S^{-1}$ respectively at 1.5 T (64 MHz). Because the T2 relaxivity of MnPC that bonded strongly, covalently manganese with phthalocyanine was very high, the signal intensity of liver parenchyma was decreased on postcontrast T2-weighted images and we could easily distinguish the VX2 carcinoma within the liver parenchyma. When MnPC was administrated intravenously, the tumor margin delineation was more remarkable than Mn-DPDP-enhanced images. The enhancement of liver parenchyma with MnPC persisted at relatively high levels over at least one hour after injection of the contrast agents. Conclusion : The hepatic uptake and biliary excretion of MnPC, which are similar to Mn-DPDP, suggest that this agent is a new liver-specific agent. Also, MnPC seems to be used as a dual contrast agent (T1 and T2) with high T2 relaxivity. However, it is warranted that MnPC needs further investigation as a potential contrast agent for MR imaging of the liver. That is, further characterizations of MnPC are needed in vivo and in vitro before clinical trials. The diagnostic potential of MnPC will also have to be examined more in the animal models of additional types.

  • PDF

Improving Usage of the Korea Meteorological Administration's Digital Forecasts in Agriculture: 2. Refining the Distribution of Precipitation Amount (기상청 동네예보의 영농활용도 증진을 위한 방안: 2. 강수량 분포 상세화)

  • Kim, Dae-Jun;Yun, Jin I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.15 no.3
    • /
    • pp.171-177
    • /
    • 2013
  • The purpose of this study is to find a scheme to scale down the KMA (Korea Meteorological Administration) digital precipitation maps to the grid cell resolution comparable to the rural landscape scale in Korea. As a result, we suggest two steps procedure called RATER (Radar Assisted Topography and Elevation Revision) based on both radar echo data and a mountain precipitation model. In this scheme, the radar reflection intensity at the constant altitude of 1.5 km is applied first to the KMA local analysis and prediction system (KLAPS) 5 km grid cell to obtain 1 km resolution. For the second step the elevation and topography effect on the basis of 270 m digital elevation model (DEM) which represented by the Parameter-elevation Regressions on Independent Slopes Model (PRISM) is applied to the 1 km resolution data to produce the 270 m precipitation map. An experimental watershed with about $50km^2$ catchment area was selected for evaluating this scheme and automated rain gauges were deployed to 13 locations with the various elevations and slope aspects. 19 cases with 1 mm or more precipitation per day were collected from January to May in 2013 and the corresponding KLAPS daily precipitation data were treated with the second step procedure. For the first step, the 24-hour integrated radar echo data were applied to the KLAPS daily precipitation to produce the 1 km resolution data across the watershed. Estimated precipitation at each 1 km grid cell was then regarded as the real world precipitation observed at the center location of the grid cell in order to derive the elevation regressions in the PRISM step. We produced the digital precipitation maps for all the 19 cases by using RATER and extracted the grid cell values corresponding to 13 points from the maps to compare with the observed data. For the cases of 10 mm or more observed precipitation, significant improvement was found in the estimated precipitation at all 13 sites with RATER, compared with the untreated KLAPS 5 km data. Especially, reduction in RMSE was 35% on 30 mm or more observed precipitation.

Evaluation between 3.0 T vs 1.5 T MRI in Detection of Brain Metastasis using Double Dose Gd-DTPA (뇌전이 종양의 발견에 있어서 Doble dose Gd-DTPA를 이용한 3 T MRI와 1.5 T MRI간의 비교연구)

  • Chung, Woo-Suk;Kim, Hyung-Jung;Ahn, Chul-Min;Lee, Jae-Hoon;Hur, Jin;Cho, Eung-Hyuck;Chung, Tae-Sub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.2
    • /
    • pp.101-108
    • /
    • 2005
  • Purpose : Early detection of small brain metastases is important. The purpose of this study was to compare the detectability of brain metastases according to the size between 1.5 T and 3.0 T MRI. Materials and Methods : We reviewed 162 patients with primary lung cancer who were examined for TNM staging. After administration of double dose of Gd-DTPA, MR imaging was performed with SPGR by 3.0 T MRI and then with T1 SE sequence by 1.5 T MRI. In each patient, three readers performed qualitative assessment. Sensitivity, positive predictive value, and diagnostic accuracy were calculated in 3.0 T and 1.5 T MRI according to size. Using the signal intensity (SI) measurements between the metastatic nodules and adjacent tissue, nodule-to-adjacent tissue SI ratio was calculated. Results : Thirty-one of 162 patients had apparent metastatic nodules in the brain at either 1.5 T or 3.0 T MR imaging. 143 nodules were detected in 3.0 T MRI, whereas 137 nodules were detected at 1.5 T MRI. Six nodules, only detected in 3.0 T MRI, were smaller than 3.0 mm in dimension. Sensitivity, positive predictive value, and diagnostic accuracy in 3.0 T MRI were 100 %, 100 %, and 100 % respectively, and in 1.5 T MRI were 95.8%, 88.3%, and 85.1% respectively. SI ratio was significantly higher in the 3.0 T MRI than 1.5 T MRI (p=0.025). Conclusion : True positive rate of 3.0 T MRI with Gd-DTPA was superior to 1.5 T MRI with Gd-DTPA in detection of metastatic nodules smaller than 3.0 mm.

  • PDF

Preliminary Study on the MR Temperature Mapping using Center Array-Sequencing Phase Unwrapping Algorithm (Center Array-Sequencing 위상펼침 기법의 MR 온도영상 적용에 관한 기초연구)

  • Tan, Kee Chin;Kim, Tae-Hyung;Chun, Song-I;Han, Yong-Hee;Choi, Ki-Seung;Lee, Kwang-Sig;Jun, Jae-Ryang;Eun, Choong-Ki;Mun, Chi-Woong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.131-141
    • /
    • 2008
  • Purpose : To investigate the feasibility and accuracy of Proton Resonance Frequency (PRF) shift based magnetic resonance (MR) temperature mapping utilizing the self-developed center array-sequencing phase unwrapping (PU) method for non-invasive temperature monitoring. Materials and Methods : The computer simulation was done on the PU algorithm for performance evaluation before further application to MR thermometry. The MR experiments were conducted in two approaches namely PU experiment, and temperature mapping experiment based on the PU technique with all the image postprocessing implemented in MATLAB. A 1.5T MR scanner employing a knee coil with $T2^*$ GRE (Gradient Recalled Echo) pulse sequence were used throughout the experiments. Various subjects such as water phantom, orange, and agarose gel phantom were used for the assessment of the self-developed PU algorithm. The MR temperature mapping experiment was initially attempted on the agarose gel phantom only with the application of a custom-made thermoregulating water pump as the heating source. Heat was generated to the phantom via hot water circulation whilst temperature variation was observed with T-type thermocouple. The PU program was implemented on the reconstructed wrapped phase images prior to map the temperature distribution of subjects. As the temperature change is directly proportional to the phase difference map, the absolute temperature could be estimated from the summation of the computed temperature difference with the measured ambient temperature of subjects. Results : The PU technique successfully recovered and removed the phase wrapping artifacts on MR phase images with various subjects by producing a smooth and continuous phase map thus producing a more reliable temperature map. Conclusion : This work presented a rapid, and robust self-developed center array-sequencing PU algorithm feasible for the application of MR temperature mapping according to the PRF phase shift property.

  • PDF

Investigation of the Correlation between Seoul Neuropsychological Screening Battery Scores and the Gray Matter Volume after Correction of Covariates of the Age, Gender, and Genotypes in Patients with AD and MCI (알츠하이머 치매 및 경도인지기능장애 환자에서 나이, 성별, 유전자형을 고려한 뇌 회백질 부피와 표준신경심리검사와의 상관관계 연구)

  • Lee, Seung-Yeon;Yoon, Soo-Young;Kim, Min-Ji;Rhee, Hak Young;Ryu, Chang-Woo;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.4
    • /
    • pp.294-307
    • /
    • 2013
  • Purpose : To investigate the correlations between Seoul Neuropsychological Screening Battery (SNSB) scores and the gray matter volumes (GMV) in patients with Alzheimer's disease (AD) and mild cognitive impairment (MCI) and cognitively normal (CN) elderly subjects with correcting the genotypes. Materials and Methods: Total 75 subjects were enrolled with 25 subjects for each group. The apolipoprotein E (APOE) epsilon genotypes, SNSB scores, and the 3D T1-weighted images were obtained from all subjects. Correlations between SNSB scores and GMV were investigated with the multiple regression method for each subject group using both voxel-based and region-of-interest-based analyses with covariates of age, gender, and the genotype. Results: In the AD group, Rey Complex Figure Test (RCFT) delayed recall scores were positively correlated with GMV. In the MCI group, Seoul Verbal Learning Test (SVLT) scores were positively correlated with GMV. In the CN group, GMV negatively correlated with Boston Naming Test (K-BNT) scores and Mini-Mental State Examimation (K-MMSE) scores, but positively correlated with RCFT scores. Conclusion: When we used covariates of age, gender, and the genotype, we found statistically significant correlations between some SNSB scores and GMV at some brain regions. It may be necessary to further investigate a longitudinal study to understand the correlation.