• Title/Summary/Keyword: 경로 검출율 측정법

Search Result 10, Processing Time 0.024 seconds

New Fault-detection Methodology of high-level event in VHDL models (VHDL 모델의 상위레벨고장 검출방법)

  • 김강철
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.651-654
    • /
    • 2004
  • In this paper, high-level events that adjust or control the conflicts between blocks or process statement, or job sequences are defined compared to low-level events. This paper proposes that high-level events consist of resources conflicts and protocol or specification-dependent conflicts, and two low-level coverage metrics can be used to defect high-level events.

  • PDF

2D Spatial-Map Construction for Workers Identification and Avoidance of AGV (AGV의 작업자 식별 및 회피를 위한 2D 공간 지도 구성)

  • Ko, Jung-Hwan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.9
    • /
    • pp.347-352
    • /
    • 2012
  • In this paper, an 2D spatial-map construction for workers identification and avoidance of AGV using the detection scheme of the spatial coordinates based on stereo camera is proposed. In the proposed system, face area of a moving person is detected from a left image among the stereo image pairs by using the YCbCr color model and its center coordinates are computed by using the centroid method and then using these data, the stereo camera embedded on the mobile robot can be controlled for tracking the moving target in real-time. Moreover, using the disparity map obtained from the left and right images captured by the tracking-controlled stereo camera system and the perspective transformation between a 3-D scene and an image plane, depth map can be detected. From some experiments on AGV driving with 240 frames of the stereo images, it is analyzed that error ratio between the calculated and measured values of the worker's width is found to be very low value of 2.19% and 1.52% on average.

Measurement of Nondestructive Residual Stress by Acoustoelasticity (음탄성에 의한 비파괴적 잔류응력 측정)

  • 박인근;이철구
    • Journal of Welding and Joining
    • /
    • v.17 no.2
    • /
    • pp.25-28
    • /
    • 1999
  • 국내에 건설되어 거의 20∼30년 가동되고 있는 발전설비, 석유화학 플랜트 등 거대설비 기기의 건전성(integrity) 및 신뢰성 확보와 잔존수명 예측을 위해서는 구조물 내부 또는 표층부에 존재하는 결 함의 특성을 아는 것과 함께 그 재료의 특정 부위에 어느정도의 응력이나 변형이 있는가를 아는 것이 매우 중요하다. 일반적으로 강 용접부의 비파괴적 결함검출에는 주로 SV파(vertically shear wave)와 SH파(horizontally shear wave)라 불리는 횡파를 이용한 초음파사각탐상법이 실용화되어 이용되고 있다. 그러나 비파괴적인 방법에 의한 실험적인 잔류응력 측정, 변형해석법에는 전기 저항 및 자기 스트레인 게이지법, X선회절법, 광탄성법(photoelasticity), 모아레(Mohr's)법, 레이저스펙클(Laser speackle)법, 응 력도료법, Barkhausen Nosise법, Caustics법 등이 제시되어 있으나 그 유용성 면에서는 아직 해결되야할 문제가 많이 남아 있는 실정이다. 응력이나 변형을 해석하는 방법으로 이론적 방법, 계산적 방법 실험적 방법이 잇다. 이론적 방법에는 재료 역학적으로 취급하는 방법, 탄성론 등이 있고, 계산적인 방법에는 유한요소법이 있지만, 이론적 방법이나 계산적 방법만으로는 해석이 불가능한 경우가 많기 때문에 실험 적 방법이 필요하게 된다. 이 글에서는 파괴 시험 또는 다른 비파괴평가기술에 비해 간편한 측정, 높은 측정정도, 시험결과 도출의 신속성, 검사비용의 절감 등 많은 장점을 가지고 있고 실험적으로 유용성이 일부 검증되고 있는 음탄성법(Acoustoelasticity)에 의한 잔류응력 측정법에 관해 소개하고자 한다.TEX> mg/L(평균 49 mg/L)로 비교적 안정적인 처리효율을 보여주었다. 본 연구결과 HVC 공정은 화학약품 사용량의 절감 및 이에 따른 화학슬러지 발생량의 감소를 기대 할 수 있는 친환경기술로 유지관리비를 최소화할 수 있는 장점이 있었다. 않은 사람들 중 미래의 검진실행의지에 건강소식지가 영향을 미친 경우는 48.7%였다. 보건교육을 받은 후 유방암 자가검진 실천율은 사업군에서 53.9%로 받기 전의 27.3%보다 증가하였으나 대조군의 경우는 별 차이가 없었다. 연령별로는 60대가 가장 높았고 사업군에서 검진율의 증가분은 30대가 가장 컸다. 교육수준별로는 사업군은 고졸이, 대조군은 전문대졸이 가장 높았고 사업군에서 검진율의 증가분은 고졸에서 가장 컸다. 보건교육 후 유방암과 관련된 건강지식의 정도는 사업군이 3.7점으로 대조군보다 유의하게 높았으며, 유방암 자가검진법을 실천하는 사람들의 동기는 ‘일반 대중매체의 영향’이 가장 많았으며 건강소식지가 동기인 경우도 20.4%였다. 사업군에서 건강소식지가 유방암 자가검진법 실천에 영향을 미친 경우가 79.6%였으며 유방암 자가검진법에 관한 보건교육을 받고 실천하지 않은 사람들 중 미래의 실천의지에 건강소식지가 영향을 미친 경우는 43.6%였다. 이상의 소견에서 지역주민을 대상으로 인쇄매체를 통한 보건교육은 인쇄물만으로도 쉽게 실천 할 수 있는 유방암 자가검진법이 가장 효과적이었으며, 자궁암검진에 관해서도 검진을 받을 수 있도록 지역사회의 보건의료의 하부구조를 정비하여 제도적 장치를 마련하고 정보를 제공한다면 자궁암검진 실천율도 증가할 것이다.고 12.9% 의 발달율을 보여 유의적인 차이를 보이지 않았다. 이상의 결과로 보아 핵이식 수정란을 효율적으로 생산하기 위하여

  • PDF

Determination of Acethylsalicylic acid (Aspirin) and Salicylic acid in Eel (Anguilla japonica) Plasma by High-performance Liquid Chromatography (HPLC에 의한 뱀장어 (Anguilla japonica) 혈장중의 acethylsalicylic acid (aspirin)과 salicylic acid의 측정)

  • Kim, Dong-Wan;Koo, Jae-Geun;Park, Sung-Woo
    • Journal of fish pathology
    • /
    • v.20 no.2
    • /
    • pp.139-145
    • /
    • 2007
  • To decrease stress in eel (Anguilla japonica) during its culture or transportation, aspirin (ASA) known as analgesic, antiinflammatory and antithrombic agent was administrated by dipping or oral routes. Concentrations of aspirin (ASA) and salicylic acid (SA) in eel plasma were simultaneously measured by a high performance liquid chromatography (HPLC). The plasma was acidified with 0.2 M HCl and 0.2 M orthophosphoric acid, and mixed with acetonitrile. ASA and SA extracted with acetonitrile were analyzed by the HPLC equipped with reversed phase Novapak C18 column (4 ㎛ silica, 150×4 mm) and UV detector(237 nm). The mobile phase consisted of 740 ㎖ water, 900 ㎕ orthophosphoric acid (85%) and 180 ㎖ acetonitrile. The retention times of ASA, SA and 2-methylbenzoic acid(MBA) were 4.8 min, 8.4 min and 11.5 min, respectively. The limit of quantification was 0.01 ㎍/㎖ for SA and 0.05 ㎍/㎖ for ASA. The mean recovery from eel plasma was 70.8~99.6% for ASA and 95.2~100.3% for SA. This HPLC method was applied to analyze ASA and SA of eel plasma after either dipping in a concentration of 20 ppm or feeding the feed supplemented with 50 ㎎/kg BW. Only SA was detected in eel plasma after the administration of ASA by dipping or oral routes because the drug was quickly decomposed into SA in eel plasma. The amount of SA in eel plasma reached the highest value at 3hr in dipping and 7 days in oral administration. When the ASA-administrated eel were kept in ASA free aquaria, 0.02-0.03 ㎍/㎖ of SA were detected 48 hr after the administration in both routes.

The Use of Radioactive $^{51}Cr$ in Measurement of Intestinal Blood Loss ($^{51}Cr$을 사용(使用)한 장관내(賜管內) 출혈량측정법(出血量測定法))

  • Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.4 no.1
    • /
    • pp.19-26
    • /
    • 1970
  • 1. Sixteen normal healthy subjects free from occult blood in the stool were selected and administered with their $^{51}Cr$ labeled own blood via duodenal tube and the recovery rate of radioactivity in feces and urine was measured. The average fecal recovery rate was 90.7 per cent ($85.7{\sim}97.7%$) of the administered radioactivity, and the average urinary excretion rate was 0.8 per cent ($0.5{\sim}1.5%$) 2. There was a close correlation between the amount of blood administered and the recovery rate from the feces; the more the blood administered, the higher the recovery rate was. It was also found that the administration of the tagged blood in the amount exceeding 15ml was suitable for measuring the radioactivity in the stools. 3. In five normal healthy subjects whose circulating erythrocytes had been tagged with $^{51}Cr$, there was little fecal excretion of radioactivity (average 0.9 ml of blood per day). This excretion is not related to hemorrhage and the main route of excretion of such an negligible radioactivity was postulated as gastric juice and bile. 4. A comparison of the radioactivity in the blood and feces of the patients with $^{51}Cr$ labeled erythrocytes seems to be a valid way of estimating intestinal blood loss.

  • PDF

Real-time Reverse Transcription Polymerase Chain Reaction Using Total RNA Extracted from Nasopharyngeal Aspirates for Detection of Pneumococcal Carriage in Children (소아에서 폐렴구균 집락률 측정을 위해 비인두 흡인 물의 총 RNA를 이용한 실시간 중합효소 연쇄반응법)

  • Kim, Young Kwang;Lee, Kyoung Hoon;Yun, Ki Wook;Lee, Mi Kyung;Lim, In Seok
    • Pediatric Infection and Vaccine
    • /
    • v.23 no.3
    • /
    • pp.194-201
    • /
    • 2016
  • Purpose: Monitoring pneumococcal carriage rates is important. We developed and evaluated the accuracy of a real-time reverse transcription polymerase chain reaction (RT-PCR) protocol for the detection of Streptococcus pneumoniae. Methods: In October 2014, 157 nasopharyngeal aspirates were collected from patients aged <18 years admitted to Chung-Ang University Hospital. We developed and evaluated a real-time PCR method for detecting S. pneumoniae by comparing culture findings with the results of the real-time PCR using genomic DNA (gDNA). Of 157 samples, 20 specimens were analyzed in order to compare the results of cultures, real-time PCR, and real-time RT-PCR. Results: The concordance rate between culture findings and the results of real-time PCR was 0.922 (P<0.01, Fisher exact test). The 133 culture-negative samples were confirmed to be negative for S. pneumoniae using real-time PCR. Of the remaining 24 culture-positive samples, 21 were identified as S. pneumonia -positive using real-time PCR. The results of real-time RT-PCR and real-time PCR from 20 specimens were consistent with culture findings for all S. pneumoniae -positive samples except one. Culture and real-time RT-PCR required 26.5 and 4.5 hours to perform, respectively. Conclusions: This study established a real-time RT-PCR method for the detection of pneumococcal carriage in the nasopharynx. Real-time RT-PCR is an accurate, convenient, and time-saving method; therefore, it may be useful for collecting epidemiologic data regarding pneumococcal carriage in children.

Evaluation of 226Ra analysis methods using a gamma-ray spectrometer and a liquid scintillation counter (감마선분광분석기와 액체섬광계수기를 이용한 226Ra 분석법 비교 연구)

  • Ju, Byoung Kyu;Kim, Moon Su;Kim, Hyun Koo;Kim, Dong Su;Cho, Sung Jin;Yang, Jae Ha;Park, Sun Hwa;Kim, Hyoung Seop;Kwon, Oh Sang;Kim, Tae Seung
    • Analytical Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.228-235
    • /
    • 2015
  • The efficiency and applicability of the solid phase extraction disk method in a 226Ra analysis were examined by the gamma ray spectrometer (GRS) method using a Marinelli beaker and the liquid scintillation counter (LSC) method for groundwater. The recovered 226Ra, which was filtered by the solid phase extraction disk, was analyzed using gamma ray spectrometer The disks, which were pretreated for caulking the daughter nuclide, were sealed with polyethylene film. Distilled water was used for the blank value of the 226Ra activity. The recovery values of 214Bi and 214Pb in the solid phase extraction disk, which used 226Ra standard material, were 80% (295.21 Kev) and 104% (351.92 Kev), respectively, which were higher than 75% determined by the LSC. The injection of nitrogen gas into the measuring chamber reduced the interference values by about 10%. The detection limits of the 226Ra activity in a blank sample of 5 L were 0.17~0.40 pCi/L after 80,000 seconds of measuring time. The relationship of the 226Ra activity in the solid phase extraction disk method and in the LSC method in seven groundwater samples showed a correlation coefficient value 0.987, which implies the applicability of the solid phase extraction disk method. The results showed that 226Ra activity in groundwater using the solid phase extraction disk method has the following benefits: simple pretreatment, time saving, high recovery values, a low detection limit, and so on. Compared with the LSC method and the GRS method using the Marinelli beaker for the 226Ra analysis, the solid phase extraction disk method could be useful in groundwater samples with low levels of activities of radionuclides because the method is not restricted by the volume of the sample.

Formaldehyde Monitoring of Hygiene Products in Domestic Market (국내 유통 위생용품 중 포름알데히드 잔류량 모니터링)

  • Na, Young-Ran;Kwon, Hyeon-Jeong;Cho, Hyun-Nho;Kim, Hyeon-Jin;Park, Yon-Koung;Park, Sung-Ah;Lee, Seong-Ju;Kang, Jung-Mi
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.3
    • /
    • pp.225-233
    • /
    • 2020
  • By the standards and specifications for hygiene products, three test methods for formaldehyde are specified for each item type of hygiene product. After derivatization using acetylacetone and 2,4-dinitrophenylhydrazine (2,4-DNPH), formaldehyde is analyzed by spectrophotometer and high-performance liquid chromatography (HPLC). Validation of the three test methods was performed on tissue, diaper lining and waterproof layer, and panty liner products. The results of linearity (R2), limit of detection (LOD), limit of quantification (LOQ), recovery rate (%) and reproducibility (%), showed that all three methods are suitable for analyzing formaldehyde in hygiene products. After derivatization with 2,4-DNPH and cetylacetone, formaldehyde was analyzed at 0, 3, 6, 9, 24 and 48 hours by HPLC. Formaldehyde derivatized with 2,4-DNPH showed no statistically significant change in formaldehyde peak area over time (P>0.05). But, acetylacetone-derivatizated formaldehyde showed a negative correlation coefficient (r) over time (P<0.01). We investigated the residual amounts of formaldehyde in 205 hygiene products distributed in Busan. Among 74 disposable diaper products tested, 73 had low concentrations of formaldehyde (0.13-29.87 mg/kg). Moreover, formaldehyde was not detected in any of 78 tissue, 27 disposable paper towel, 12 disposable dishcloth, 7 paper cup, one brand of paper straw and 6 disposable napkin products.

An analytical method of soap biodegradability with fatty acid p-BPB derivatives (지방산의 p-BPB 유도체에 의한 비누 생분해도 분석 방법)

  • Oh, Se-Woong;Lee, Ja-Kyoung;Chung, Yong;Chang, Sug-Youn;Kim, Yeo-Kyung
    • Analytical Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.9-19
    • /
    • 1993
  • Fatty acid salts derived from soap can be transferred into a typical derivative with p-bromophenacyl bromide using crown ether, a catalizer by the solid-liquid phase transfer reaction in nonpolar, aprotic solvents and separated by the reverse phase high performance liquid Chromatography (RP-HPLC) and determined using UV detector. The minimal limit of detection was defined at approximately 10~50ng in accordance with the chain length. The derivatization reaction in the presence of EDTA can be applied mot only to the calcium salts but also to the other various metal salts. The recoveries of fatty acid derivatizations in the absence and presence of the midium containing the yeast extract were obtained $95.4{\pm}1.2$, and $85.2{\pm}2.4%$ respectively. The analytical method would be applicable to determine the biodegradation of fatty acid salts in nature as well as in artificial condition such as shaker flask-medium method.

  • PDF

Histopathological and Serological Observations on Experimental Anisakiasis of Rabbits (실험적 토끼 아니사키스증에서의 조직학적 병변과 혈청 항체가의 경시적 변동 양상)

  • 홍성태;이손형
    • Parasites, Hosts and Diseases
    • /
    • v.25 no.2
    • /
    • pp.168-180
    • /
    • 1987
  • This study was performed to observe histopathological changes and serological reactions in chronic anisakiasis of rabbits. Each rabbit was infected per os with 30 larvae of Anisakis type I. Their sera were collected chronologically and the rabbits were killed for histopathological examination, 3, 13, 20, 30, 60, 90 and 150 days after the infection. The results were summarized as below. 1. Most of the larvae were recovered from the stomach, but a few from the omentum, intestine, mesentery and abdominal wall. The recovery rates and distribution of worms by organ were not differed by duration of infection. 2. Histologically the lesion was abscess type on 13 days, i.e., the dead worms were surrounded by fibrinous exudate, histiocytes and thick zone of numerous inflammatory cells. After 30 days, histiocytes were found to invade the worms and the lesion was changing into abscessgranulomatous type. Also a calcified worm was found on the 30th day. After then the worms were observed to be dissolved slowly until 90 days. On 150 day, only one calcified worm was observed. 3. The levels of serum IgG antibody by ELISA reached their maximum 30 days after the infection. After then, it decreased slowly until 150 days after the infection. Above serological and histopathological findings indicated that antigenic stimulation from degenerating Anisakis larvae was the greatest during the first 30 days after infection. This period was corresponding with the beginning of worm resolution or calcification. Serologic test by ELISA would be a valuable tool for confirming chronic anisakiasis.

  • PDF