• Title/Summary/Keyword: 견관절와

Search Result 137, Processing Time 0.028 seconds

Reverse Total Shoulder Arthroplasty: Where we are? "Principles" (견관절 역행성 인공관절 치환술의 원칙)

  • Noh, Kyu-Cheol;Suh, Il-Woo
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.105-110
    • /
    • 2011
  • Purpose: The purpose of this article is to identify and understand the complications of RTSA and to review the current methods of preventing and treating this malady. Materials and Methods: Previous constrained prostheses (ball-and-socket or reverse ball-and-socket designs) have failed because their center of rotation remained lateral to the scapula, which has limited of the motion of the prostheses and produced excessive torque on the glenoid component, and this leads to early loosening. The Grammont reverse prosthesis imposes a new biomechanical environment for the deltoid muscle to act, thus allowing it to compensate for the deficient rotator cuff muscles. Results: The clinical experience does live up to the lofty biomechanical concept and expectations: the reverse prosthesis restores active elevation above $90^{\circ}$ in patients with a cuff-deficient shoulder. However, external rotation often remains limited and particularly in patients with an absent or fat-infiltrated teres minor. Internal rotation is also rarely restored after a reverse prosthesis. Failure to restore sufficient tension in the deltoid may result in prosthetic instability. Conclusion: Finally, surgeons must be aware that the results are less predictable and the complication/revision rates are higher in revision surgery than that in the first surgery. A standardized monitoring tool that has clear definitions and assessment instructions is surely needed to document and then prevent complications after revision surgery.

Glenoid Labral Cyst with Anterior Labral Tear in the Shoulder - A Case Report - (견관절 전방 관절과 순 파열을 동반한 관절와 순 낭종 - 1례 보고-)

  • Kim Young Kyu;Song Min Ho
    • Clinics in Shoulder and Elbow
    • /
    • v.3 no.1
    • /
    • pp.49-53
    • /
    • 2000
  • There are few case reports of glenoid labral cysts related to the labral tear in the shoulder. Glenoid labral cyst is often overlooked in the diagnosis of shoulder pain. We are reporting a case of a glenoid labral cyst accompanying with anterior labral tear in the right shoulder of a 42 years old woman with the history of trauma. The cyst and anterior labral tear was successfully treated with arthroscopic excision and repair.

  • PDF

Revision of Failed Shoulder Instability Repair (실패한 견관절 불안정증의 봉합술에 대한 재수술)

  • Park, Jin-Young;Park, Hong-Geun;Oh, Jeong-Hwan
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.2
    • /
    • pp.135-140
    • /
    • 2006
  • Diagnosis and treatment of the unstable shoulder is one of the more difficult problems in orthopaedic surgery. There is confusion between the normal laxity with translation and subluxation of the humeral head relative to the glenoid and an abnormal amount of laxity, leading to pain and dysfunction. Unfortunately, there is no single treatment that applied to all lesions that cause the instability. It is imperative, therefore, that an accurate diagnosis be made, including the directions and degree of shoulder instability as well as any coexisting problems. Anatomical defects must be defined. Common factors that could most readily compromised instability repair are examined. These include techniques for making an accurate diagnosis with identification of the precise anatomical pathology, and the rationale for appropriate surgical treatment with the avoidance of technical complication such as unnecessary hardware or exposures that might lead to residual instability, arthritis, and nerve or vascular injuries. Additional injuries may be prevented by careful rehabilitation postoperatively to restore shoulder stability, flexibility, and endurance prior to an individual's return to stressful sports or work.

  • PDF

Alternative Fixation Technique for Bony Bankart Lesion with Using Suture Anchor (봉합나사와 골터널을 이용한 골성 반카르트 병변의 고정)

  • Kim, Byung-Kook;Lee, Ho-Jae;Kim, Go-Tak;Dan, Jinmyoung
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.6
    • /
    • pp.574-578
    • /
    • 2019
  • For the treatment of a bony Bankart lesion accompanied by an acute traumatic shoulder dislocation, anatomical reduction and stable fixation of the bone fragment and glenohumeral ligament are essential to avoid chronic instability or degenerative changes. If the Bankart lesion has large bony pieces or comminuted fragments, it can be difficult to perform precise and secure fixation of the big intraarticular fragment to the fracture site because of the limited visualization of the arthroscopic procedure. In addition, in the case of the open procedure, it requires an extensive surgical dissection to access the fractured fragment, which may cause surgical approach-related morbidity, such as neurovascular complications, delayed subscapularis healing, and increased risk of stiffness. This paper describes an alternative open suture anchor technique for a large bony Bankart lesion, which was secured anatomically with squared knots after a shuttle relay through bony tunnels and adjacent soft tissue and labrum. This technique can achieve anatomical and firm fixation under direct vision, and reduce the number of surgery related morbidities.

Arthroscopic Reconstruction in Anterior Shoulder Instability - Prospective Comparison of Anteroinferior Plication Versus Inferior Plication - (견관절 전방 불안정성의 관절경하 재건술 - 전하방 관절낭 중첩술과 하방 관절낭 중첩술의 전향적 비교 -)

  • JP, Warner Jon;Ko, Sang-Hun;Jeon, Hyung-Min
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.1
    • /
    • pp.27-32
    • /
    • 2009
  • Purpose: We wanted to evaluate the effectiveness of inferior capsular plication for treating the anterior instability of the shoulder by comparing the prospective outcomes and the incidence of complications of the group (group1) that underwent arthroscopic vertical shift of the anteroinferior capsulo-labral complex and plication of the anterior band of inferior glenohumeral ligament and the group (group2) that underwent inferior capsular plication that was augmentated by the same method. Materials and Methods: From March 2005 to August 2007, we compared group 1 (42 cases) that underwent arthroscopic vertical shift of the anteroinferior capsulo-labral complex and plication of the anterior band of the inferior glenohumeral ligament and group 2 (33 cases) that underwent augmentated inferior capsular plication for recurrent anterior instability of the shoulder. The mean age was 22.5 years (range: 17~31 years) in group I, and 21.8 years (range: 16~30 years) in group II. The mean follow up was 23.5 months (range: 12~45 months in group I, and 20.1 months (range: 12~49 months) in group II. We checked the Rowe score and ROM preoperatively and at postoperative 6 months, 1 year and at the last follow up and we compared the incidence of complications. Results: The Rowe score increased from a preoperative mean of 20.6 to the last follow up mean of 86.8 after surgery in group I, and the Rowe score increased from a preoperative mean of 20.5 to the last follow up mean of 94.1 after surgery in group II. For the anterior instability of the shoulder, arthroscopic reconstruction had a good outcome in all of the cases, but group II had better outcomes and less complications than did group I (p<0.05). Conclusion: We thought that arthroscopic vertical shift of the anteroinferior capsulo-labral complex and plication of the anterior band of the inferior glenohumeral ligament with inferior capsular plication can lower the complication rate and show better outcomes.

Arthroscopic Reduction and Internal Fixation with Cannulated Screw of a Transverse Glenoid Fracture (유경 나사를 이용한 견갑골 관절와 횡골절의 관절경적 정복 밑 내고정)

  • Noh Kyu Cheol;Yoo Jung Han;Kang Ki Man
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.2
    • /
    • pp.176-180
    • /
    • 2003
  • We describe in this report the accurate reduction of a transverse displaced glenoid fracture through arthroscopic control . We used the lateral and superior (Neviaser portal) portal of the arthroscopic surgery in the shoulder joint for the U 4.0-mm titanium cannulated cancellous screw fixation. The advantages of this treatment are excellent intra-articular visualiBation, decreased soft tissue dissection ,less blood loss, shortened postoperative recovery and early ROM exercise. There(ore, we report the method of operation and the cases .

  • PDF

The Usefulness of Multidetector CT Arthrography in the Diagnosis of Shoulder Pathology -Comparison with MR Arthrography and Arthroscopic Findings in the Same Patient- (견관절 병변의 진단에서 다중 검출 전산화 단층촬영을 이용한 관절조영술의 유용성 - 동일 환자에서 시행한 자기공명 관절조영술 및 관절경 소견과의 비교 -)

  • Kim, Dong-Soo;Park, Kyoung-Jin;Kim, Yong-Min;Choi, Eui-Sung;Shon, Hyun-Chul;Cho, Byung-Ki;Park, Ji-Kang;Kim, Seok-Won
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.115-125
    • /
    • 2009
  • Purpose: The purpose of the study is to evaluate the usefulness of CT arthrography (CTA) by conducting a comparative study of CTA and MR arthrography (MRA) with the arthroscopic findings in the same patients. Materials and methods: Forty nine patients who suffered from shoulder disease underwent MRA and CTA concurrently. The sensitivity and specificity of CTA was evaluated, as compared to MRA, in the case of four types of shoulder pathological lesions. The accuracy of CTA was evaluated by analyzing the arthroscopic findings of thirty four patients. Results: Compared to MRA, CTA showed a sensitivity of 90% and a specificity of 100% for diagnosing supraspinatus tendon (SST) full thickness tear, and CTA showed a sensitivity of 100% and a specificity of 97.5% for making the diagnosis of superior labrum anterior to posterior (SLAP) lesion. For diagnosing partial articular side supraspinatus avulsion (PASTA) lesion, some studies have shown the usefulness of CTA with a sensitivity of 71.4% and a specificity of 97.7%. However, for diagnosing SST bursal side partial tear, the sensitivity of CTA was as low as 10%. CTA has been shown to be relatively accurate when the diagnoses were verified with the arthroscopic findings; diagnosing SST full thickness tear and SLAP lesion with CTA has shown an accuracy of 100% and87.5% respectively, and CTA showed 71.4% diagnostic accuracy for PASTA lesion. Conclusion: CTA was a useful tool and it was equivalent to MRA for the assessment of SST full thickness tear, SLAP lesion and PASTA lesion, but not bursal side partial tear. Thus, it may be used preferably to diagnose shoulder pathology and for follow up as an inexpensive tool after operation.

Investigation for Shoulder Kinematics Using Depth Sensor-Based Motion Analysis System (깊이 센서 기반 모션 분석 시스템을 사용한 어깨 운동학 조사)

  • Lee, Ingyu;Park, Jai Hyung;Son, Dong-Wook;Cho, Yongun;Ha, Sang Hoon;Kim, Eugene
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.68-75
    • /
    • 2021
  • Purpose: The purpose of this study was to analyze the motion of the shoulder joint dynamically through a depth sensor-based motion analysis system for the normal group and patients group with shoulder disease and to report the results along with a review of the relevant literature. Materials and Methods: Seventy subjects participated in the study and were categorized as follows: 30 subjects in the normal group and 40 subjects in the group of patients with shoulder disease. The patients with shoulder disease were subdivided into the following four disease groups: adhesive capsulitis, impingement syndrome, rotator cuff tear, and cuff tear arthropathy. Repeating abduction and adduction three times, the angle over time was measured using a depth sensor-based motion analysis system. The maximum abduction angle (θmax), the maximum abduction angular velocity (ωmax), the maximum adduction angular velocity (ωmin), and the abduction/adduction time ratio (tabd/tadd) were calculated. The above parameters in the 30 subjects in the normal group and 40 subjects in the patients group were compared. In addition, the 30 subjects in the normal group and each subgroup (10 patients each) according to the four disease groups, giving a total of five groups, were compared. Results: Compared to the normal group, the maximum abduction angle (θmax), the maximum abduction angular velocity (ωmax), and the maximum adduction angular velocity (ωmin) were lower, and abduction/adduction time ratio (tabd/tadd) was higher in the patients with shoulder disease. A comparison of the subdivided disease groups revealed a lower maximum abduction angle (θmax) and the maximum abduction angular velocity (ωmax) in the adhesive capsulitis and cuff tear arthropathy groups than the normal group. In addition, the abduction/adduction time ratio (tabd/tadd) was higher in the adhesive capsulitis group, rotator cuff tear group, and cuff tear arthropathy group than in the normal group. Conclusion: Through an evaluation of the shoulder joint using the depth sensor-based motion analysis system, it was possible to measure the range of motion, and the dynamic motion parameter, such as angular velocity. These results show that accurate evaluations of the function of the shoulder joint and an in-depth understanding of shoulder diseases are possible.

Accuracy and Clinical Outcomes of Ultrasound-guided Glenohumeral joint Injection: Acromioclavicular Approach in Patients with Adhesive Capsulitis (초음파를 이용한 견관절 관절강내 주사의 정확성과 임상적 결과: 유착성 관절낭염 환자의 견봉 쇄골 접근법)

  • Lhee, Sang-Hoon;Hwang, Seok-Min
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.5 no.1
    • /
    • pp.9-14
    • /
    • 2012
  • Purpose: The purpose of the study was to evaluate the accuracy and clinical outcome of ultrasound-guided glenohumeral joint steroid injection on adhesive capsulitis. Materials and Methods: Patients who were diagnosed as adhesive capsulitis by MRI and physical examination and did not improve their symptom with physical therapy and NSAIDS treatment more than 6 months were included in the study. Patients who showed any other shoulder pathology or history if trauma were excluded from the study. 33 patients including 15 males and 18 females were enrolled in the study, the average age being 55.1 (age 42~72). Cocktail of steroid, lidocaine, saline and contrast medium injected inside shoulder glenohumeral joint using novel approach (which we called acromioclavicular approach) under ultrasound guidance. Clinical outcome was measured through passive range of motion and VAS scoring system. Results: Based on radiographic findings, cases were classified according to the leakage of contrast medium; perfect confinement of contrast-medium inside the capsule, partial leakage of the medium and contrast-medium found at outside the joint. Total 25 cases (76%) out of 33 cases showed perfect confinement of contrast-medium inside the glenohumeral joint. Partial leakage was observed in 6 cases (18%), and contrast medium was observed outside of the glenohumeral joint in 2 cases (6%). Perfect-confinement group showed $111^{\circ}$($80{\sim}140^{\circ}$) of forward flexion and $48^{\circ}$($0{\sim}90^{\circ}$) of external rotation before injection, and improved to $134^{\circ}$($90{\sim}150^{\circ}$) of forward flexion and $70^{\circ}$($30{\sim}90^{\circ}$) of external rotation after injection (p<0.01). Partial leakage showed $120^{\circ}$($90{\sim}150^{\circ}$) of forward flexion and $70^{\circ}$($10{\sim}90^{\circ}$) of external rotation before injection, and improved to $139^{\circ}$($135{\sim}140^{\circ}$) of forward flexion and $78^{\circ}$($50{\sim}90^{\circ}$) of external rotation after injection (p<0.01). VAS score improved from 7.1 (score 3~9) to 2.6 (score 0~5) (p<0.01) in perfect confinement group, from 7.5 (score 7~9) to 3.3 (score 2~4) (p<0.01) in partial leakage group. Two group showed no significant difference. Conclusion: Accuracy of Acromioclavicular approach was 94% which is better than any other methods published so far. Partial leakage of the injection material did not show inferior result compared to perfect injection.

  • PDF