• Title/Summary/Keyword: 게인 제어

Search Result 454, Processing Time 0.028 seconds

Postoperative Radiation Therapy in the Management of Early Cervical Cancer (초기 자궁경부암의 수술 후 방사선치료의 효과)

  • Kim, Jae-Chul
    • Radiation Oncology Journal
    • /
    • v.24 no.3
    • /
    • pp.164-170
    • /
    • 2006
  • [ $\underline{Purpose}$ ]: This study identified the result of postoperative radiation therapy and the prognostic factors to affect survival rates in cancer patients. $\underline{Materials\;and\;Methods}$: One hundred and thirty three patients with cervical cancer who were treated with postoperative radiation therapy following surgery at our institution between June 1985 and November 2002 were retrospectively analyzed. One hundred and thirteen patients had stage IB disease, and 20 patients had stage IIA disease. Histological examination revealed 118 squamous cell carcinoma patients and 15 adenocarcinoma patients. Sixty seven patients were noted to have stromal invasion greater than 10 mm, and 45 patients were noted to have stromal Invasion 10 mm or less. Positive lymphovascular invasion was found in 24 patients, and positive pelvic lymph nodes were noted in 39 patients. Positive vaginal resection margin was documented in 8 patients. All of the patients were treated with external beam radiation therapy to encompass whole pelvis and primary surgical tumor bed. Intracavitary radiation therapy was added to 19 patients who had positive or close surgical margins. $\underline{Results}$: Actuarial overall and disease-free survival rates for entire group of the patients were 88% and 84% at 5 years, respectively. Five-year disease-free survival rates for patients with stromal invasion greater than 10 mm and 10 mm or less were 76% and 97%, respectively (p<0.05). Also there was a significantly lower survival in patients with positive pelvic lymph nodes compared with patients with negative pelvic lymph nodes (p<0.05). However, lymphovascular invasion, positive vaginal resection margins were not statistically significant prognostic factors. Addition of neoadjuvant chemotherapy or type of surgery did not affect disease-free survival. $\underline{Conclusion}$: Postoperative radiation therapy appears to achieve satisfactory local control with limited morbidity in cervical cancer patients with high pathologic risk factors. Distant metastasis was a dominant failure pattern to affect survival in cervical cancer patients after radical surgery and radiation and more effective systemic treatment should be investigated in these high-risk patients.

Analysis and Improvement of System Efficiency for the Moving-actuator type Bi-Ventricular Assist Device ($AnyHeart^{TM}$) (한국형 양심실 보조 인공 심장의 효율 분석 및 개선에 관한 연구)

  • Chung, J.H.;Nam, K.W.;Choi, S.W.;Lee, J.J.;Park, C.Y.;Kim, W.E.;Choi, J.S.;Min, B.G.
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.5
    • /
    • pp.449-458
    • /
    • 2001
  • This is a test report of system efficiency for the moving-actuator type Bi-ventricular assist device (AnyHear $t^{MT}$ ) Seoul National University). $AnyHeart^{TM}$), as an energy converter. utilities a brushless DC motor(S/M 566-26A. Sierracin/ Magnedyne, Carlsbad, CA. U.S.A.) generating their pendulous motion in the epicyclic gear train. It is necessary to know about the overall efficiency of the system. The system is subdivided into three parts: motor part, actuator part and blood sac part (including valves, etc.) according to system mechanism. The motor was operated with a variable range of torque. angular speed and width of voltage Pulse In this report. $AnyHeart^{TM}$ is focused on the efficiency of the motor and actuator parts. 4 $\ell/min$ pump output. which is normal condition of $AnyHeart^{TM}$ system, the total system efficiency is 8%, which is composed of 50%, 85% and 17% efficiency (motor Part, actuator Part and blood sac Part) respectively. In the analyzed result. applied input voltage on normal condition of $AnyHeart^{TM}$ is determined. Also speed Profile with considering filling state of blood sac is Provided. In the test of the in vitro mock circulation. some experimental results are Provided to demonstrate the effectiveness of the Presented approach.

  • PDF

A Design and Fabrication of the X-Band Transmit/Receive Module for Active Phased Array SAR Antennas (능동 위상 배열 SAR 안테나를 위한 X-대역 송수신 모듈의 설계 및 제작)

  • Chong, Min-Kil;Kim, Sang-Keun;Na, Hyung-Gi;Lee, Jong-Hwan;Yi, Dong-Woo;Baik, Seung-Hun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.10
    • /
    • pp.1050-1060
    • /
    • 2009
  • In this paper, a X-Band T/R-module for SAR(Synthetic Aperture Radar) systems based on active phased array antennas is designed and fabricated. The T/R modules have a and width of more than 800 MHz centered at X-Band and support dual, switched polarizations. The output power of the module is 7 watts over a wide bandwidth. The noise figure is as low as 3.9 dB. Phase and amplitude are controlled by a 6-bit phase shifter and a 6-bit digital attenuator, respectively. Further the fabricated T/R module has est and calibration port with directional coupler and power divider. Highly integrated T/R module is achieved by using LTCC(Low Temperature Co-fired Ceramic) multiple layer substrate. RMS gain error is less than 0.8 dB max. in Rx mode, and RMS phase error is less than $4^{\circ}$ max. in Rx/Tx phase under all operating frequency band, or the T/R module meet the required electrical performance m test. This structure an be applied to active phase array SAR Antennas.

Characteristics of Nutrient Concentrations of Outflow during Storms in a Rural Watershed (비점원 농촌유역으로부터 강우시 유출수의 농도특성)

  • Oh, Kwang-Young;Kim, Jin-Soo;JiAng, Jie
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.457-461
    • /
    • 2006
  • 비점원 농촌유역으로부터 강우시 영양물질(질소, 인)의 유출특성을 파악하기 위해 2002년부터 2005년까지 5개의 강우사상을 대상으로 $2{\sim}12$시간 간격으로 유량 및 수질을 측정하였다. 강우사상시 TN농도는 유량이 증가함에 따라 상승하여 최대농도를 보인 후, 유량감소에 따라 농도가 감소하는 경우와 초기농도보다 높은 농도로 유지되는 경우의 두 가지 경향을 보였다. TP농도는 유량의 증가에 따라 급격한 상승을 보였고, 최대 값 이후 농도가 낮아져 거의 초기농도에 도달하였다. 또한, 초기농도에 대한 최대농도값의 비는 TP가 TN보다 크게 나타났다. 농촌 소유역에서의 초기유출현상(first-flush)은 40%의 누적유출량을 나타낼 때 TP의 누적유출부하량은 $70{\sim}86%$를 기록하여, 도시유역(60%)과 광역논(50%)보다 크게 나타났는데, 이는 농촌 소유역이 경사가 크고 밭 등에서 강우로 인한 토양침식 등의 영향을 크게 받기 때문으로 사료된다. 4개의 강우사상에 대한 질소의 용존성 성분의 비(TN/TDN비)는 93.6%를 나타내 질소는 대부분 용존성 형태로 유출되는 것으로 나타났고, 인의 용존성 성분의 비(TP/TDP비)는 25.4%를 나타내 인의 대부분 입자성 형태로 유출되는 것으로 나타났다. 따라서, 비점원 농촌유역으로부터 TN부하를 저감시키기 위해서는 용존성 성분을 제공하는 비료의 시용량을 줄여야 하며, TP부하를 저감시키기 위해서는 강우시 입자성 인의 유출을 제어해야 한다. 이를 위해서는 비가 많이 오는 여름철에 나지(裸地)나 밭에 식생이나 멀칭(mulching) 등으로 토양침식을 방지하는 대책이나 하천변에 완충역(riparian buffer zone)을 설치하는 대책이 필요하다. 저수지 관리를 효과적으로 수행하기 위해서는 저수지 내부의 탁도 거동을 정확히 예측할 수 있어야 한다. 따라서 추후 동수역학 및 열역학에 기초한 3차원 수치모형 연구와 성층흐름에 정밀한 밀도류 실험연구 및 이에 대한 적용이 필요할 것으로 판단된다.함으로써 정보의 질적보장과 정보전환의 표준화방안을 제시하는 정보분석시스템이다.이용, 수자원의 지속적 확보기술의 특성에 따른 4개의 평가기준과 26개의 평가속성으로 이루어진 2단계 기술가치평가 모형을 구축하였으며 2개의 개별기술에 대한 시범적용을 실행하였다.하는 것으로 추정되었다.면으로의 월류량을 산정하고 유입된 지표유량에 대해서 배수시스템에서의 흐름해석을 수행하였다. 그리고, 침수해석을 위해서는 2차원 침수해석을 위한 DEM기반 침수해석모형을 개발하였고, 건물의 영향을 고려할 수 있도록 구성하였다. 본 연구결과 지표류 유출 해석의 물리적 특성을 잘 반영하며, 도시지역의 복잡한 배수시스템 해석모형과 지표범람 모형을 통합한 모형 개발로 인해 더욱 정교한 도시지역에서의 홍수 범람 해석을 실시할 수 있을 것으로 판단된다. 본 모형의 개발로 침수상황의 시간별 진행과정을 분석함으로써 도시홍수에 대한 침수위험 지점 파악 및 주민대피지도 구축 등에 활용될 수 있을 것으로 판단된다. 있을 것으로 판단되었다.4일간의 기상변화가 자발성 기흉 발생에 영향을 미친다고 추론할 수 있었다. 향후 본 연구에서 추론된 기상변화와 기흉 발생과의 인과관계를 확인하고 좀 더 구체화하기 위한 연구가 필요할 것이다.게 이루어질 수 있을 것으로 기대된다.는 초과수익률이 상승하지만, 이후로는 감소하므로, 반전거래전략을 활용하는 경우 주식투자기간은 24개월이하의 중단기가 적합함을 발견하였다. 이상의 행태적 측면과 투자성과측면의 실증결과를 통하여 한국주식시장에

  • PDF

Influence of Strain-Hardening Cement Composite's Tensile Properties on the Seismic Performance of Infill Walls (변형경화형 시멘트 복합체의 인장성능에 따른 끼움벽의 내진성능)

  • Cha, Jun-Ho;Yun, Hyun-Do
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.1
    • /
    • pp.3-14
    • /
    • 2012
  • This paper describes experimental results on the seismic performance of SHCC (strain-hardening cement composite) infill wall for improving damage tolerance capacity of non-ductile frame. To investigate the effect of tensile strain capacity and cracking behavior of SHCC materials on the shear behavior of SHCC infill wall, three infill walls were fabricated and tested under cyclic loading. The test parameter in this study is a type of cement composites; concrete and SHCCs. The two types of SHCC materials were prepared for infill walls. In order to induce crack damages into the mid-span of the infill wall, each infill wall had two 100-mm-deep-notches on both sides. Test results indicated that SHCC infill walls showed superior crack control capacities and much larger drift ratios at the peak loads than RC (reinforced concrete) infill wall, as expected. In particular, due to the bridging actions of the reinforcing fibers, SHCC matrix used in this study would delay the stiffness degradation of infill wall after the first inclined cracking. Moreover, from the damage classes based on the cracks' maximum width in the infill walls, it was observed that PIW-SHD specimen possessed nearly threefold seismic capacities compared to PIW-SLD specimen. Also, from the results on the strain of diagonal reinforcements, it can be concluded that the SHCC matrix would resist a part of tensile stresses transferred along steel rebar in the infill wall.

Design and Implementation of Bio-data Monitering System Based on ISO/IEEE 11073 DIM/REST for IoT Healthcare Service (IoT 헬스케어 서비스를 위한 ISO/IEEE 11073 DIM/REST 기반 생체정보 모니터링 시스템 설계 및 구현)

  • Choi, Ju-Hyun;Chun, Seung-Man;Jang, Dong-Hyun;Park, Jong-Tae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.3
    • /
    • pp.3-12
    • /
    • 2015
  • Recently, various studies have been attempted to provide a biological information monitoring service through integrating with the web service. The medical information transmission standard ISO/IEEE 11073 PHD defines the optimized exchange protocol ISO/IEEE 11073-20601 based on the No-IP to exchange the biometric information between the ISO/IEEE 11073 agent and the manager. It's system structure based on the No-IP using ISO/IEEE 11073-20601 is not suitable for providing a remote biological information monitoring services. That is because it is difficult to provide to control and manage the biological information measurement devices, which have installed IP protocol stack at the remote. Furthermore, ACSE and CMDISE in ISO/IEEE 11073-20601 are not suitable to provide U-healthcare services based on IoT because they are complicated and difficult to implement it caused by the structural complexity. In order to solve the problems, in this paper, we propose the biological information monitoring architecture based on ISO/IEEE 11073 DIM/REST of IoT environment to provide the biological information monitoring service based on IoT. To do this, we designed biological information monitoring system architecture based on IoT and the message exchange protocol of ISO/IEEE 11073 DIM/REST between the ISO/IEEE 11073 agent and the ISO/IEEE 11073 manager. In order to verify the realistic possibility of the proposed system architecture, we developed the service prototype.

Antioxidant, anti-inflammatory, and anti-pruritic effects of grape branch extract (포도가지 추출물의 산화방지, 항염증 및 항가려움 효과)

  • Cho, Byoung Ok;Yin, Hong Hua;Che, Denis Nchang;Kim, Sang Jun;Ryu, Cheol;Jang, Seon Il
    • Korean Journal of Food Science and Technology
    • /
    • v.48 no.6
    • /
    • pp.590-596
    • /
    • 2016
  • This study was designed to investigate the antioxidant activities of the ethanol extracts (GBE) of grape branches (Campbell Early). The total polyphenol and flavonoid content of GBE was $201.42{\pm}4.16$ and $11.85{\pm}0.44mg\;GAE/g$, respectively. The antioxidant activity of GBE was measured using the ABTS and DPPH assays, and the $IC_{50}$ values were $45.60{\pm}0.09$ and $299.13{\pm}0.22$, respectively. GBE inhibited the production of pro-inflammatory mediators (NO, iNOS, $PGE_2$, COX-2, $IL-1{\beta}$, and IL-6) in lipopolysaccharide-stimulated RAW 264.7 macrophages in a dose-dependent manner. Moreover, GBE treatment significantly suppressed the production of $TNF-{\alpha}$ and IL-6 cytokines in phorbol 12-myristate 13-acetate plus calcium ionophore A23187-stimulated HMC-1 human mast cells. Furthermore, the administration of GBE markedly inhibited the scratching behavior induced by the compound 48/80 in ICR mice. These results suggested that GBE has potential as a therapeutic agent against inflammation and itch-related skin diseases.

Control of histamine-forming bacteria by probiotic lactic acid bacteria isolated from fish intestine (생선 내장으로부터 분리된 프로바이오틱 유산균에 의한 히스타민 생산균의 제어)

  • Lim, Eun-Seo;Lee, Nahm-Gull
    • Korean Journal of Microbiology
    • /
    • v.52 no.3
    • /
    • pp.352-364
    • /
    • 2016
  • In this study, we examined in vitro the potential probiotic properties of lactic acid bacteria (LAB) obtained from the fish intestine and their ability to degrade histamine through the production of diamine oxidase (DAO) enzymes and bacteriocin. Among 97 LAB strains isolated from the intestine of croaker, flatfish, pollack, and rockfish, CIL08, CIL16, FIL20, FIL31, PIL45, PIL49, PIL52, and RIL60 isolates exhibited excellent survival rates under simulated gastrointestinal tract conditions, high adhesion ability to HT-29 epithelial cells, and resistance to the antibiotics such as amoxicillin, ampicillin, erythromycin, penicillin G, streptomycin, tetracycline, or vancomycin. In addition, these strains did not produce histamine in decarboxylating broth containing histidine. In particular, 4 strains (CIL08, FIL20, PIL52, and RIL60) that may produce DAO were significantly able to degrade histamine. The bacteriocins produced by FIL20, FIL31, and PIL52 LAB inhibited the growth and histamine production of Enterococcus aerogenes CIH05, Serratia marcescens CIH09, Enterococcus faecalis FIH11, Pediococcus halophilus FIH15, Lactobacillus sakei PIH16, Enterococcus faecium PIH19, Leuconostoc mesenteroides RIH25, or Aeromonas hydrophilia RIH28. Histamine-producing strains isolated from fish intestine were found to reduce histamine accumulation during co-culture with CIL08, FIL20, PIL52, and RIL60 LAB showing histamine degradation or bacteriocin production ability. The probiotic strains preventing histamine formation were identified as Pediococcus pentosaceus CIL08, Lactobacillus plantarum FIL20, Lactobacillus paracasei FIL31, Lactobacillus sakei PIL52, and Leuconostoc mesenteroides RIL60 with high similarity based on 16S rRNA gene sequencing.

A Study on the Installation of a Sewage Separator Pipe inside an Existing Combined Sewer System for CSO Control (기존 합류식 하수관거에 CSO 제어를 위한 하수분리관의 설치에 관한 연구)

  • Guerra, Heidi B.;Kim, Youngchul
    • Journal of Wetlands Research
    • /
    • v.23 no.1
    • /
    • pp.85-93
    • /
    • 2021
  • Sewage separation which often involves installing a new pipe to separate wastewater flow from stormwater runoff flow can be costly and depends highly on its feasibility in a site. To be able to develop a potentially more economical alternative that can also lessen major road traffic disturbance during this process, a different approach where a smaller sewage separator pipe is installed inside an existing combined sewer pipe was investigated. A small-scale of a box sewer and the proposed sewage separator pipe was constructed in the laboratory to observe and compare the deposition of solids and other solid-associated major pollutants at different flow rates. In addition, three-dimensional flow simulations considering five different scenarios were conducted using Ansys Fluent to observe the effect of the proposed sewage separator pipe to the hydraulic flow if installed inside the combined sewer pipe. Results revealed that the deposition of TSS, TCOD, TN, and TP were reduced by at least 60% when the wastewater was conveyed by the sewage separator pipe instead of the combined sewer pipe. Moreover, the flow simulations conducted showed that there was little to no major disturbance in hydraulic flow and velocity distribution when the sewage separator was installed inside a straight pipe and even at pipe transitions such as intersections, turns, and drop in elevation. Considering the pipe dimensions and the results of the study, the proposed approach can be promising in terms of reduction in pollutant deposition without a major effect on the hydraulic flow. Further investigation and cost-analysis should be done in the future to support these preliminary findings and help alleviate the problems caused by combined sewer overflows by introducing an alternative approach.

A study on process optimization of diffusion process for realization of high voltage power devices (고전압 전력반도체 소자 구현을 위한 확산 공정 최적화에 대한 연구)

  • Kim, Bong-Hwan;Kim, Duck-Youl;Lee, Haeng-Ja;Choi, Gyu-Cheol;Chang, Sang-Mok
    • Clean Technology
    • /
    • v.28 no.3
    • /
    • pp.227-231
    • /
    • 2022
  • The demand for high-voltage power devices is rising in various industries, but especially in the transportation industry due to autonomous driving and electric vehicles. IGBT module parts of 3.3 kV or more are used in the power propulsion control device of electric vehicles, and the procurement of these parts for new construction and maintenance is increasing every year. In addition, research to optimize high-voltage IGBT parts is urgently required to overcome their very high technology entry barrier. For the development of high-voltage IGBT devices over 3.3 kV, the resistivity range setting of the wafer and the optimal conditions for major unit processes are important variables. Among the manufacturing processes to secure the optimal junction depth, the optimization of the diffusion process, which is one step of the unit process, was examined. In the diffusion process, the type of gas injected, the injection time, and the injection temperature are the main variables. In this study, the range of wafer resistance (Ω cm) was set for the development of high voltage IGBT devices through unit process simulation. Additionally, the well drive in (WDR) condition optimization of the diffusion process according to temperature was studied. The junction depth was 7.4 to7.5 ㎛ for a ring pattern width of 23.5 to25.87 ㎛, which can be optimized for supporting 3.3 kV high voltage power devices.