• Title/Summary/Keyword: 검.교정

Search Result 112, Processing Time 0.026 seconds

Review on Pre-processing of Earthquake Data from KEPRI Seismic Monitoring System (전력연구원 지진관측자료의 사전자료처리 기법 및 효과적인 활용에 관한 고찰)

  • 연관희;박동희;최원학;장천중
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.2
    • /
    • pp.39-50
    • /
    • 2002
  • Several pre-processing techniques for earthquake data from earthquake monitoring institutes in Korea including Korea Electric Power Research Institute are thoroughly reviewed. Among these techniques for removing an instrumental response, removing the non-causal ringing distortion by FIR filter, checking calibration status of seismic stations, and minimizing the window effect are introduced and applied to real data. It is also recommended that analysts evaluate S/N ratio in the frequency domain and consider the possibility of using the saturated earthquake data.

A COMPARATIVE STUDY ON THE PHYSICAL PROPERTIES OF ORTHODONTIC PLIERS ACCORDING TO TYPES OF STERILIZATION (멸균 방법에 따른 교정용 플라이어의 물성 변화에 대한 비교 연구)

  • Cho, Il-Je;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.28 no.2 s.67
    • /
    • pp.329-341
    • /
    • 1998
  • Sterilization has received much attention in orthodontic practices over the past several years. The present study was undertaken to investigate the effects of sterilization on the physical properties of orthodontic pliers-AEZ, Unitek, and Dentronix ligature cutters. This study was designed to examine the tips of ligature cutters before and after 200 and 400 sterilization cycles using the Bowmar RHT-1000, the Dentronix DDS-5000, and the Eschmann SES-2000. The tip surface and the fracture surface were observed with a scanning electron microscope. The microstructure was observed with an optical microscope. The hardness test was carried out with the mic개-Vickers hardness tester and the Rockwell C Scale hardness tester. The chemical composition was analyzed by energy dispersive X-ray spectrometer. The results of this study were as follows : 1. The number and the size of corrosion products on the tip surface and the proportion of cleavage planes in fractured specimen increased, but the hardness of the tip decreased in proportion to sterilization cycles. From these observations, it was considered that mechanical properities decreased in proportion to sterilization cycles. 2. The number and the size of chromium carbides increased in proportion to sterilization cycles. Coarse microstructure decreased mechanical properities. 3. The AEZ and Unitek ligature cutters were Fe-Cr stainless steels, but the Dentronix ligature cutter was Co-Cr alloy. There were many differences among manufactures, but the chemical composition was .not changed after sterilization cycles. 4. The tip edge of ligature cutter used in a clinic revealed microcracks with the SEM observation. Clinical experience confirmed that ligature cutters were gradually degraded by sterilization.

  • PDF

Correlation between Corneal Ablation Amount and Intraocular Pressure after Corneal Refractive Surgery (각막굴절교정수술 후 각막절삭량과 안압변화의 상관관계)

  • Jung, Mi-A;Lee, Eun-Hee
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.543-551
    • /
    • 2018
  • Purpose : The purposes of this study were to evaluate the changes of intraocular pressure according to corneal ablation amount after corneal refractive surgery and the changes of intraocular pressure according to refractive errors before corneal refractive surgery. Methods : The mean age of adults who underwent LASIK corneal refractive surgery were $37.34{\pm}7.42years$, and 108 adults(48 males, 60 females) were participated in this study. Refractive errors, intraocular pressure, and corneal ablation amount were measured using an autorefractor, a noncontact tonometer, and an excimer laser. All test values were considered statistically significant when p<0.05. Results : The mean intraocular pressure before corneal refractive surgery was $15.08{\pm}2.60mmHg$ in males and $14.16{\pm}2.67mmHg$ in females. The decrease of intraocular pressure after corneal refractive surgery were 4.22mmHg in males and 3.61mmHg in females. Spherical equivalent power were $-3.89{\pm}2.17D$ in males and $-4.45{\pm}2.92D$ in females before corneal refractive surgery, and $-0.10{\pm}0.46D$ in males and $-0.04{\pm}0.46D$ in females after corneal refractive surgery. The corneal ablation amount after corneal refractive surgery were statistically significant, with $53.95{\mu}m$ in males and $61.26{\mu}m$ in females. There was significant correlation between corneal ablation amount and decrease of intaocluar pressure(r=0.2299, p<0.001). As the growth of corneal ablation amount in males, the decrease of intraocular pressure was significantly increased. As the growth of refractive error, the amount of decrease in intraocular pressure was also significant. The decrease of intraocualr pressure were $3.04{\pm}2.18mmHg$ in low refractive error, $4.10{\pm}2.16mmHg$ in middle refractive error, and $4.65{\pm}3.29mmHg$ in high refractive error. Conclusion : We found that intraocular pressure decreased after corneal refractive surgery by noncontact tonometer and the change of intraocular pressure which is an important index for glaucoma diagnosis, may affect the judgment of eye disease. We think that a preliminary questionnaire whether corneal refractive surgery is necessary for the measurement of intraocular pressure.

The Development of Air-kerma Strength Calculation Algorithm in Terms of the Absorbed Dose to Water for HDR Ir-192 Source (기준점에서의 물 흡수선량을 이용한 Ir-192 선원의 공기커마 세기 계산을 위한 알고리즘 개발)

  • Huh, Hyun-Do;Kim, Woo-Chul;Loh, John-Jk;Lee, Suk;Lee, Sang-Hoon;Cho, Sam-Ju;Shin, Dong-Oh;Choi, Jin-Ho;Kwon, Soo-Il;Kim, Seong-Hoon
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.232-237
    • /
    • 2006
  • The aim of this study was to develop the calculation algorithm of source strength of Ir-192 source In terms of the absorbed dose to water instead of an apparent activity (Ci). For this work the Multi Purpose Brachytherapy Phantom(MPBP) was developed, which was designed to locate the source and the chamber precisely at a specific position Inside the water phantom. The reference point of measurement was set at the 5 cm distance along the transverse axis of the source. For a brachytherapy source calibration, the absorbed dose to water calibration factor ($N_{D.W.Q}$) of an lonization chamber were determined and then apply standard protocols of absorbed dose to water. The calibration factor ($N_{D.W.Q}$) of the ion chamber (TM30013, PTW, Germany) was determined using the EGSnrcCPP Monte Carlo Code. The calculated calibration factor ($N_{D.W.Q}$) was 5.28 cGy/nC. The calculated factor was then used to determine the absorbed dose to water from which the air kerma strength for an Ir-192 source can be easily derived at the reference point (5 cm). The calculated air kerma strength showed discrepancies of -0.6% to +1.8% relative to the air kerma strength provided by the vendor, In this work we demonstrated that the air kerma strength ($S_k$) could be determined from the absorbed dose to water calibration factor for Ir-192 source. In audition, this source calibration method could be applied directly to the dose Calculation formalism of AAPM report TG-43.

  • PDF

Increasing Surveyed Area using Tilted Multi Beam Echo Sounder (멀티빔 음향측심기의 기울임 시스템을 이용한 계측영역 확대)

  • Park, Yosup;Hong, Jun-Pyo;Kong, Seong-Kyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.5D
    • /
    • pp.739-747
    • /
    • 2011
  • The paper presents implementation & evaluation of survey method with tilted transducer of Multi Beam Echo Sounder (MBES) to increase horizontal & vertical coverage over obstructed port environments with limited physical properties of MBES. Proposed method ($25^{\circ}$ titled transducer) have some discrepancy of bathymetric profiles between normal and tilting method, but we proved average difference is less than IHO Special Order requirements with survey data at port of Dong Ho Port, Masan, Korea. For horizontal mapping coverage of total survey area ($114,961m^2$), normal method covered 53%, $60,895m^2$ of total area but tilting method covered 75%, $5.933m^2$. It is 22% efficient than normal method with similar environments. For vertical mapping coverage of total vertical structure face ($7,421m^2$), normal method covered 14%, $1,046m^2$, proposed methods covered 60%, $4,450m^2$. And we adapt longitudal steel bar to validate MBES results, and provide calibration method with titled transducer of MBES.

THE EFFECTS OF SALIVARY CONTAMINATION OF ACID-ETCHED ENAMEL ON BRACKET BOND STRENGTH (산부식 후 타액오염이 교정용 접착제의 결합강도에 미치는 영향)

  • Kim, Hyun-Deog;Kim, Jong-Sung;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.26 no.3
    • /
    • pp.309-316
    • /
    • 1996
  • The purpose of this study was to determine the effect of salivary contamination of etched enamel on shear bond strength of a bracket adhered to etched enamel. Eighty extracted human permanent premolars were used in this study. These samples were divided into two groups. Buccal surface of samples were etched in vitro with 38% phosphoric acid for 15 seconds and 60 seconds. Each group was divided into four subgroups. Etched enamel surfaces were contaminated with saliva for 0, 1, 20, 60 seconds, washed and dried. Test surfaces were examined using scanning electron microscope(SEM). The shear bond strength of each sample was determined with a universal testing instrument(Instron Co. Model 4201). Results were as follows; 1. Salivary contamination for 1, 20, 60 seconds did not affect shear bond strength when compared with the uncontaminated enamel group. 2 There was no significant difference(P>.05) in shear bond strength between 15 sec. and 60 sec. etching in uncontaminated enamel groups. 3. When samples were examined using SEM, organic materials coated enamel surface masked the etched pattern partially.

  • PDF

A Clinical Report on the Effect of CRS Usage in Degenerative Temporomanibular Joint Disease with Anterior Open Bite Applying Bone Scan (전치부 개교합을 보이는 퇴행성 관절질환에서 골스캔을 이용한 중심위교합장치의 효과 평가에 대한 임상례)

  • 박상배;김병국
    • Journal of Oral Medicine and Pain
    • /
    • v.23 no.3
    • /
    • pp.289-294
    • /
    • 1998
  • 본 증례는 측두하악관절의 퇘행성 변화를 보이는 환자에서 악교정 수술의 시행 전에 중심위교합장치를 통해 측두하악관절의 안정화를 유도하고, 또한 골스캔을 이용하여 장치의 치료효과를 평가한 임상증례이다. 환자는 24세의 여성으로 5년 전부터 전치부 개교합이 발생되기 시작하였고, 고형식 저작시 좌측 전이부에 간헐적인 통증이 발생한다는 주소로 본원에 내원하였다. 임상검사상 촉진시 양측 관절낭 후방부에 압통을 호소하였으며, 각각 50, 45mm의 최대개구량 및 최대무통성 개구량을 보였다. 좌측 악관절부에서 단순 관절 잡음, 우측 악관절부에서 염발음이 청취되었으며, 저항검사 및 부하 검사에서는 특기할 반응을 보이지 않았다. 약 7mm의 전치부 개교합의 소견을 보였으며, 파노라마 사진과 횡두개 방사선 사진 소견상 양측 과두의 크기 및 하악지의 높이가 다소 작은 소견이 관찰되었고 자기공명영상 소견상 양측성 비정복성 관절원판의 전방전위가 관찰되었다. 1997년 10월 27일 첫 번째 골스캔 소견상 양측성 비정복성 관절원판의 전방위가 관찰되엇다. 골스캔의 전방 사진에서 Densitometer를 이용하여 좌, 우측 과두부위와 상악 골부위의 가장 어두운 부분의 흑화도를 측정하였다. 각각 3회씩 구하여 평균을 구하고 좌, 우측 과두 대 상악골의 흑화도의 비율을 계산하였다. 첫번째 골스캔의 평균 흑화도는 우측 과두, 좌측과두, 상악골이 각각 0.88, 0.81, 1.32 였다. 1997년 11월 4일 중심위교합장치를 장착하였고 지속적인 물리치료를 시행하였다. 1997년 12월 10일 두 번째 골 스캔을 평균 흑화도는 우측 과두, 좌측 과두, 상악골이 각각 0.33, 0.37, 088 이었다. 1998년 1월 30일 세 번째 골스캔 소견상 두 번째 골스캔과 비교하여 활성도가 감소된 소견을 보였다. 임상검사시 무통이었다. 1998년 2월 25일 술 전 교정 위해 중심위교합장치의 장작을 중지시켰다. 1998년 6월 5일 네 번째 골스캔 소견상 이전 검사들과 비교시 흡수가 감소된 소견을 보였다. 네 번째 골스캔의 평균 흑화도는 우측 과두, 좌측 과두, 상악골이 각각 0.24, 0.19, 0.85 였다. 현재 지속적인 관찰 중이며 본원 교정과에서 악교정수술 위한 술 전 교장을 시행중이다. 결국 첫 번째 골스캔의 과두 대 상악골의 평균 흑화도의 비율은 우측과 좌측이 각각 0.66, 0.61이었고 두 번째 골스캔에서는 우측과 좌측이 각각 0.37, 0.42였고, 네번째 골스캔에서는 우측과 좌측이 각각 0.28, 0.23 이었다. 각 골스캔의 과두 대 상악골의 평균 흑화도의 비율 사이에 유의한 차이가 있는지 검증하기 위해 Standard t-test 와 ANOVA를 시행하였다. 이상의 결과에서 첫 번째, 두 번째, 네 번째 골스캔으로 갈수록 좌, 우측 과두 대 상악골의 흑화도의 비율이 유의하게 감소했음을 알 수 있었다. 결론적으로 본 증례에서는 전치부 개교합이 발생되어 악교정수술이 필요한 환자에게 측두하악관절의 안정화를 위해 중심위교합장치를 사용함으로써 퇴행성 관절질환의 진행을 억제시킬 수 있고, 퇴행성 관절질환의 활성도에 대한 평가시 골스캔이 유용할 수 있음을 보여주었다고 사료된다.

  • PDF

DESIGN OF A RISE TIME DISCRIMINATION CIRCUIT FOR X-RAY PROPORTIONAL COUNTER (X-선 비례계수관용 상승시간 선별회로 제작)

  • 남욱원;최철성
    • Journal of Astronomy and Space Sciences
    • /
    • v.12 no.1
    • /
    • pp.66-77
    • /
    • 1995
  • It is possible to distinguish X-ray events from non X-ray events in proportional conters using the method of rise time discrimination (RTD). In order to subtract non X-ray background, we have developed a simple RTD circuit which will be applied to the proportional counter planned for a sounding rocket experiment. The entire circuit consists of two parts ; the rise time measurement circuit and the time to amplitude conversion circuit which includes the self-calibration mode. From the test with X-ray detecting system, we obtained that the background can be rejected more than 80% in the energy band 2∼12 keV. However we confirmed that the RDT method is not proper to be used for the energy range above 12kV.

  • PDF

Design Conformance Verification of Military FM Radio Set Automatic Test Equipment (군용 FM 무전기 세트 자동시험장비(ATE) 설계 적합성 검증)

  • Kim, Byung-Jun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.3
    • /
    • pp.389-396
    • /
    • 2020
  • In order to obtain a good quality product, a proper verification of production/test facilities must be preceded before the quality conformity inspection of the product. Among the various production/test facilities, ATE is widely used in the civilian industry such as the automotive industry, aerospace industry, semiconductor industry today. In addition, ATE is actively used in the defense industry production and performance tests. This paper is the result of systematically verifying the Design Conformance of ATS which is ATE of military FM radio set using various methods. And It is expected to be a good reference at the present time when the design conformity verification procedure for ATE for military supplies is not documented.

MIRIS 우주관측 카메라 Noise Test

  • Park, Yeong-Sik;Lee, Dae-Hui;Mun, Bong-Gon;Jeong, Ung-Seop;Lee, Chang-Hui;Park, Seong-Jun;Lee, Deok-Haeng;Pyo, Jeong-Hyeon;Nam, Uk-Won;Park, Jang-Hyeon;Lee, Seung-U;Matsumoto, Toshio;Han, Won-Yong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.126.2-126.2
    • /
    • 2011
  • MIRIS(Multipurpose InfraRed Imaging System)는 과학기술위성 3호의 주 탑재체이며 2012년 하반기 발사예정이다. MIRIS 우주관측 카메라는 0.9-2.0 ${\mu}m$ 영역에서 3.67 deg. x 3.67 deg. FOV로 우리 은하평면 survey 관측과 우주배경복사(CIB) 관측을 수행할 것이다. 현재 MIRIS는 비행모델 개발 마무리 단계에 있으며, 검교정 시험, 열-진공 시험, 진동 시험 등을 수행하고 나면 2011년 말 위성 본체와의 조립을 진행할 것이다. 망원경이 복사냉각(Passive Cooling)을 통해 200K 이하로 냉각되면, dewar에 설치된 소형 냉각기를 가동하여 적외선 센서를 90K 정도로 냉각한다. MIRIS 우주관측카메라에는 PICNIC($256{\times}256$ pixel) 센서를 사용하였고, 상온과 냉각된 상태에서의 노이즈 특성을 측정하였다. PICNIC 센서와 dewar내부를 냉각하기 위해 RICOR사의 K-508 micro stirling cooler를 사용하는데, cooler가 동작하면서 전자부에 영향을 주어 주된 잡음으로 나타남을 확인하였다. Cooler에서 발생하는 잡음을 최소화 하기위해 fanout B/D와 LVPS 부분을 개선하였으며, 본 발표에서는 잡음 측정 결과에 대해 논의 하고자 한다.

  • PDF