• Title/Summary/Keyword: 검출율 측정법

Search Result 190, Processing Time 0.03 seconds

New Fault-detection Methodology of high-level event in VHDL models (VHDL 모델의 상위레벨고장 검출방법)

  • 김강철
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.651-654
    • /
    • 2004
  • In this paper, high-level events that adjust or control the conflicts between blocks or process statement, or job sequences are defined compared to low-level events. This paper proposes that high-level events consist of resources conflicts and protocol or specification-dependent conflicts, and two low-level coverage metrics can be used to defect high-level events.

  • PDF

시간특성을 고려한 음성신호의 발성율 검출에 관한 연구

  • 김익성;서지호;배명진
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.109-111
    • /
    • 2004
  • 발성율은 일정한 시간동안 발성되는 음성신호 내에 몇 개의 음절이 포함되어 있는 지를 나타낸다. 발성율은 화자마다 다르고 각 음소들의 특징에 따라 변화할 수 있다. 발성율의 사전 측정이 이루어 진다면 음성부호화 측면에서도 중용한 정보로 사용될 수 있다. 기존의 음성부호화기는 발성율에 관계없이 고정적인 분석 구간을 정하여 전송률을 결정하고 있다. 따라서, 발성율을 미리 측정한다면, 발성율이 느린 부분과 빠른 부분에 각기 다른 부호화 방법을 적용하여 음질을 향상할 수도 있고 전송률을 가변적으로 적용할 수 도 있게 된다. 정확한 발성율을 측정하기 위해서는 음절의 변화를 추정하여야 한다. 음절의 변화를 추정하기 위한 방법으로 음성신호의 에너지 포락선 측정법과 LSP를 이용한 측정법이 각각 제안된 바 있으나, 본 논문에서는 위 두 가지 방법을 혼합한 방법을 사용하였다. 에너지 변동은 음성신호의 시간영역 처리방법으로 LSP 파라미터는 음성신호의 선형예측 분석에 의해 구해질 수 있다.

  • PDF

A Sensitivity Verification Method for the UHF Partial Discharge Detection System in the Gas Insulated Switchgear (GIS용 UHF 부분방전검출장치의 감도 측정법)

  • Goo, Sun-Geun;Park, Ki-Jun;Yoon, Jin-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1558-1560
    • /
    • 2001
  • 네트워크 분석기를 이용하여 GIS용 UHF 부분방전 검출장치가 CIGRE 권고안을 만족시킴을 보일 수 있는 방법을 제안하였다. 이 방법은 운전중인 GIS에서도 활용이 가능하며 주파수 영역에서 GIS 내 부분방전신호의 감쇠율을 정확히 측정할 수 있고 측정 시스템의 개별부품에 대한 교정이 필요치 않다. 또한 측정한 GIS의 구간별 감쇠율을 이용해 센서의 종류와 부분방전검출장치 및 GIS의 구성에 따라 센서의 위치를 손쉽게 결정할 수 있다.

  • PDF

Analysis of HBeAg and HBV DNA Detection in Hepatitis B Patients Treated with Antiviral Therapy (항 바이러스 치료중인 B형 간염환자에서 HBeAg 및 HBV DNA 검출에 관한 분석)

  • Cheon, Jun Hong;Chae, Hong Ju;Park, Mi Sun;Lim, Soo Yeon;Yoo, Seon Hee;Lee, Sun Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.35-39
    • /
    • 2019
  • Purpose Hepatitis B virus (hepatitis B virus, HBV) infection is a worldwide major public health problem and it is known as a major cause of chronic hepatitis, liver cirrhosis and liver cancer. And serologic tests of hepatitis B virus is essential for diagnosing and treating these diseases. In addition, with the development of molecular diagnostics, the detection of HBV DNA in serum diagnoses HBV infection and is recognized as an important indicator for the antiviral agent treatment response assessment. We performed HBeAg assay using Immunoradiometric assay (IRMA) and Chemiluminescent Microparticle Immunoassay (CMIA) in hepatitis B patients treated with antiviral agents. The detection rate of HBV DNA in serum was measured and compared by RT-PCR (Real Time - Polymerase Chain Reaction) method Materials and Methods HBeAg serum examination and HBV DNA quantification test were conducted on 270 hepatitis B patients undergoing anti-virus treatment after diagnosis of hepatitis B virus infection. Two serologic tests (IRMA, CMIA) with different detection principles were applied for the HBeAg serum test. Serum HBV DNA was quantitatively measured by real-time polymerase chain reaction (RT-PCR) using the Abbott m2000 System. Results The detection rate of HBeAg was 24.1% (65/270) for IRMA and 82.2% (222/270) for CMIA. Detection rate of serum HBV DNA by real-time RT-PCR is 29.3% (79/270). The measured amount of serum HBV DNA concentration is $4.8{\times}10^7{\pm}1.9{\times}10^8IU/mL$($mean{\pm}SD$). The minimum value is 16IU/mL, the maximum value is $1.0{\times}10^9IU/mL$, and the reference value for quantitative detection limit is 15IU/mL. The detection rates and concentrations of HBV DNA by group according to the results of HBeAg serological (IRMA, CMIA)tests were as follows. 1) Group I (IRMA negative, CMIA positive, N = 169), HBV DNA detection rate of 17.7% (30/169), $6.8{\times}10^5{\pm}1.9{\times}10^6IU/mL$ 2) Group II (IRMA positive, CMIA positive, N = 53), HBV DNA detection rate 62.3% (33/53), $1.1{\times}10^8{\pm}2.8{\times}10^8IU/mL$ 3) Group III (IRMA negative, CMIA negative, N = 36), HBV DNA detection rate 36.1% (13/36), $3.0{\times}10^5{\pm}1.1{\times}10^6IU/mL$ 4) Group IV(IRMA positive, CMIA negative, N = 12), HBV DNA detection rate 25% (3/12), $1.3{\times}10^3{\pm}1.1{\times}10^3IU/mL$ Conclusion HBeAg detection rate according to the serological test showed a large difference. This difference is considered for a number of reasons such as characteristics of the Ab used for assay kit and epitope, HBV of genotype. Detection rate and the concentration of the group-specific HBV DNA classified serologic results confirmed the high detection rate and the concentration in Group II (IRMA-positive, CMIA positive, N = 53).

Measurement of Ventilatory Threshold in the Patients with Chronic Airway Obstruction (만성기도폐쇄를 보이는 환자에서 환기성역치 측정)

  • Lee, Kye-Young;Jee, Young-Koo;Kim, Keun-Yeol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.2
    • /
    • pp.309-320
    • /
    • 1997
  • Background : There are many suggested methods for the indirect determination of anaerobic threshold(AT) using the changes of ventilatory parameters in response to ventilatory load accompanying the increase of blood lactic acid level during exercise and the threshold derived from them is called ventilatory threshold(VT). They include ventilatory equivalent method(VEM), End-tidal $PO_2$ method($PETO_2$). V-slope method(VSM), and respiratory quotient method(RQ). But in the patients with chronic airway obstruction(CAO), the AT determined by ventilatory methods may not reflect true AT because the patients with CAO show inadequate ventilatory response to the increase of blood lactic acid level during excercise. Methods : For the investigation of detection rate and reliability of above four VT determination methods in the patients with CAO, we performed the symptom-limited and maximal incremental exercise test in 17 patients with CAO and 12 normal controls. The incremental workload was 10 W /min in CAO group and 25 W/min in control group. The reliability of VT in each group was investigated by the calculation of Spearman correlation coefficient. Results : The detection rates of VT were 100% by RQ, 91.7% by both VEM and $POETO_2$, and 83.3% by VSM in normal control group, while 94.1% by RQ, 64.7% by VEM and $PETO_2$, and 83.3% by VSM in CAO group. Good correlations were noted among VEM, $POETO_2$, and VSM except RQ in normal control group. But there was no significant correlation except between VEM and $PETO_2$ in CAO group. Conclusions : RQ is very sensitive but crude and VEM is near similar to $PETO_2$. The clinical usefulness of VT determined by ventilatory method might be limited in patients with severe CAO.

  • PDF

Field Map Estimation for Effective Fat Quantification at High Field MRI (고자장 자기공명영상에서 효율적인 지방 정량화를 위한 필드 맵 측정 기술)

  • Eun, Sung-Jong;Whangbo, Taeg-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.11
    • /
    • pp.558-574
    • /
    • 2014
  • The number of fatty liver patients is sharply growing due to the rapid increase in the incidence of metabolic syndrome, which can lead to diseases such as abdominal obesity, hypertension, diabetes, and hyperlipidemia. Early diagnosis requires examinations using magnetic resonance imaging (MRI), wherein quantitative analyses are implemented through a professional water-fat separation method in many cases, as the intensity values of the areas of interest and non-interest are considerably similar or the same. However, such separation method generates inaccurate results in high magnetic fields, where the inhomogeneity of the fields increases. To overcome the limits of such conventional fat quantification methods, this paper proposes a field map estimation method that is effective in high magnetic fields. This method generates field maps through echo images that are obtained using the existing IDEAL sequences, and considers the wrapping degree of the field maps. Then clustering is performed to separate calibration areas, the least square fits based on the region growing method schema of the separated calibration areas, and the histograms are adjusted to separate the water from the fats. In experiment results, our proposed method had a superior fat detection rate of an average of 86.4%, compared to the ideal method with an average of 61.5% and Yu's method with an average of 62.6%. In addition, it was confirmed that the proposed method had a more accurate water detection rate of 98.4% on the average than the 88.6% average of the fat saturation method.

Automated algorithm of automated auditory brainstem response for neonates (신생아 청성뇌간 반응의 자동 판독 알고리즘)

  • Jung, Won-Hyuk;Hong, Hyun-Ki;Nam, Ki-Chang;Cha, Eun-Jong;Kim, Deok-Won
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.1
    • /
    • pp.100-107
    • /
    • 2007
  • AABR(automated auditory brainstem response) test is used for the screening purpose of hearing ability of neonates. In this paper, algorithm using Rolle's theorem is suggested for automatic detection of the ensemble averaged ABR waveform. The ABR waveforms were recorded from 55 normal-hearing ears of neonates at screening levels varying from 30 to 60 dBnHL. Recorded signals were analyzed by expert audiologist and by the proposed algorithm. The results showed that the proposed algorithm correctly identified latencies of the major ABR waves (III, V) with latent difference below 0.2 ms. No significant differences were found between the two methods. We also analyzed the ABR signals using derivative algorithm and compared the results with proposed algorithm. The number of detected candidate waves using the proposed algorithm was 47 % less than that of the existing one. The proposed method had lower relative errors (0.01 % error at 60dBnHL) compared to the existing one. By using proposed algorithm, clinicians can detect and label waves III and V more objectively and quantitatively than the manual detection method.

HPLC를 이용한 축육(Pork Muscle)내의 Dihydrostreptomycin 검출법

  • Choe, Ji-Hyeon;Han, Eun-Yeong;Park, Jin-Gwan;Lee, Su-Yeon;Choe, Dong-Mi;Sin, Ho-Cheol;Lee, Chi-Ho
    • Proceedings of the Korean Society for Food Science of Animal Resources Conference
    • /
    • 2005.10a
    • /
    • pp.196-203
    • /
    • 2005
  • 축산식품 고기내의 잔류항생물질을 신속하고 간편하고 정확하게 분석하기 위한 시험법 개발 을 목적으로 하였다. 축산식품내의 일반적인 잔류항생물질에 대한 지금까지의 분석법으로는 Bioassay법, TLC법, ELISA법, GC법 및 HPLC법 등이 있지만 Streptomycin/Dihydro streptomycin, Neomycin에 대한 HPLC법은 거의 확립되어 있지 않은 실정이다. 우리나라의 공인 검사법으로는 Bioassay법 및 HPLC법 등이 있지만 그러나 지금까지의 방법으로는 검출감도가 낮은 것이 큰 문제점으로 되어 왔다. 본 연구에서는 DST에 대한 HPLC법에 대한 보고한 P. Edder 방법 중에 clean-up과정 및 이동상 조건을 대폭 수정하여 DST의 분리 및 검출감도를 낮추려고 시도하였다. 본 연구에 사용된 유도체화 장치 Post-Column Derivatization Instrument PCX 5100 (Pickering Laboratories, Inc.)의 컬럼온도는 $40^{\circ}C$, 오븐온도 $55^{\circ}C$, reagent 유속 0.6ml/min mobile phase 유속 0.8ml/min으로 검출기는 형광검출기를 이용하여 DST 검출에 대해 만족할 만한 결과를 얻었다. 이때의 분석소요시간은 약 15분이었다. 표준시료 DST의 검량선은 넓은 농도범위(0.02${\sim}$1.0ppm)에서 양호한 직선성을 나타냈다. 본 시험법에 의한 검출한계는 limit of detection (LOD)은 0.02ppm이었으며, 적어도 고기에서의 MRL이 0.6ppm임을 감안하면 DST를 정량적으로 정도 좋게 측정할 수 있다는 것을 확인했다. 상기의 조건하에서 실제시료인 고기에 표준 DST를 1ppm을 spiking한 후 SPE상에서 SCX(Strong cation exchange column)을 통한 clean-up과정을 거친 후의 DST의 limit of quantification(LOQ)는 약 0.47ppm이었으며, 이에 대한 회수율은 97.7%(n= 8)를 나타냈다. 실제 codex에서 권장한 고기의 MRL이 0.6ppm인 점을 감안하면 codex 권고치에 도달할 수 있는 것으로 판단되었다. 따라서 본 연구에서 개발된 시험법은 지금까지 국내적으로 DST에 대한 시험법이 확립되어 있지 않은 것으로 이와 아울러 간편한 parallux와 병용해 DST에 대한 정량 및 정성 분석을 유도체화 장치 및 형광검출기를 이용해 잔류항생물질 DST에 대한 분석시험법의 개발이 가능하다고 여겨진다.

  • PDF

HPLC를 이용한 우유 중에 잔류 항생물질(Streptomycin)의 정량 분석

  • Byeon, Jang-Won;Park, Hwan-Seok;Hong, Go-Eun;Hong, Mu-Gi;Park, Gwan-Ha;Lee, Chi-Ho
    • Proceedings of the Korean Society for Food Science of Animal Resources Conference
    • /
    • 2005.10a
    • /
    • pp.310-316
    • /
    • 2005
  • 축산식품(우유)내의 잔류항생물질을 신속하고 간편하고 정확하게 분석하기 위한 시험법 개발을 목적으로 하였다. 축산식품내의 일반적인 잔류항생물질에 대한 지금까지의 분석법으로는 Bioassay법, TLC법, ELISA법, GC법 및 HPLC법 등이 있지만 Streptomycin/dihydrostreptomycin, neomycin에 대한 HPLC법은 거의 확립되어 있지 않은 실정이다. 우리나라의 공인 검사법으로는 Bioassay법 및 HPLC법등이 있지만 그러나 지금까지의 방법으로는 검출감도가 낮은 것이 큰 문제점으로 되어 왔다. 본 연구에서는 STP에 대한 HPLC법에 대한 보고한 Edder 방법 중에 clean-up 과정 및 이동상 조건을 대폭 수정하여 STP의 분리 및 검출감도를 낮추려고 시도하였다. 본 연구에 사용된 유도체화 장치 Post-Column Derivatization Instrument PCX 5100 (Pickering La-boratories, Inc.)의 컬럼 온도는 $40^{\circ}C$, 오븐온도 $55^{\circ}C$, 유도체화 용매 유속 0.6ml/min 이동상 유속 0.8ml/min으로 검출기는 형광검출기를 이용하여 STP 검출에 대해 만족할 만한 결과를 얻었다. 이때의 분석소요시간은 약 15분이었다. 표준시료 STP의 검량선은 넓은 농도범위(0.02${\sim}$1.0ppm)에서 양호한 직선성을 나타냈다. 본 시험법에 의한 검출한계는 limit of detection(LOD)은 0.02ppm이었으며, 적어도 우유에서의 MRL이 0.6ppm임을 감안하면 STP를 정량적으로 정도 좋게 측정할 수 있다는 것을 확인했다. 상기의 조건하에서 실제시료인 우유에 표준 STP를 0.5ppm을 spiking한 후 SPE상에서 SCX(Strong cation exchange column)을 통한 clean-up과정을 거친 후의 STP의 limit of quantification(LOQ)는 약 0.44ppm이었으며, 이에 대한 회수율은 89.7${\pm}$2.3%(n=6)를 나타냈다. 실제 CODEX에서 권장한 우유의 MRL이 0.6ppm인 점을 감안하면 CODEX권고치에 도달할 수 있는 것으로 판단되었다. 따라서 본 연구에서 개발 된 시험법은 지금까지 국내적으로 STP에 대한 시험법이 확립되어 있지 않은 것으로 이와 아울러 간편한 parallux와 병용해 STP에 대한 정량 및 정성 분석을 유도체화 장치 및 형광검출기를 이용해 잔류항생물질 STP에 대한 분석시험법을 개발하였다.

  • PDF

Measurement of Nondestructive Residual Stress by Acoustoelasticity (음탄성에 의한 비파괴적 잔류응력 측정)

  • 박인근;이철구
    • Journal of Welding and Joining
    • /
    • v.17 no.2
    • /
    • pp.25-28
    • /
    • 1999
  • 국내에 건설되어 거의 20∼30년 가동되고 있는 발전설비, 석유화학 플랜트 등 거대설비 기기의 건전성(integrity) 및 신뢰성 확보와 잔존수명 예측을 위해서는 구조물 내부 또는 표층부에 존재하는 결 함의 특성을 아는 것과 함께 그 재료의 특정 부위에 어느정도의 응력이나 변형이 있는가를 아는 것이 매우 중요하다. 일반적으로 강 용접부의 비파괴적 결함검출에는 주로 SV파(vertically shear wave)와 SH파(horizontally shear wave)라 불리는 횡파를 이용한 초음파사각탐상법이 실용화되어 이용되고 있다. 그러나 비파괴적인 방법에 의한 실험적인 잔류응력 측정, 변형해석법에는 전기 저항 및 자기 스트레인 게이지법, X선회절법, 광탄성법(photoelasticity), 모아레(Mohr's)법, 레이저스펙클(Laser speackle)법, 응 력도료법, Barkhausen Nosise법, Caustics법 등이 제시되어 있으나 그 유용성 면에서는 아직 해결되야할 문제가 많이 남아 있는 실정이다. 응력이나 변형을 해석하는 방법으로 이론적 방법, 계산적 방법 실험적 방법이 잇다. 이론적 방법에는 재료 역학적으로 취급하는 방법, 탄성론 등이 있고, 계산적인 방법에는 유한요소법이 있지만, 이론적 방법이나 계산적 방법만으로는 해석이 불가능한 경우가 많기 때문에 실험 적 방법이 필요하게 된다. 이 글에서는 파괴 시험 또는 다른 비파괴평가기술에 비해 간편한 측정, 높은 측정정도, 시험결과 도출의 신속성, 검사비용의 절감 등 많은 장점을 가지고 있고 실험적으로 유용성이 일부 검증되고 있는 음탄성법(Acoustoelasticity)에 의한 잔류응력 측정법에 관해 소개하고자 한다.TEX> mg/L(평균 49 mg/L)로 비교적 안정적인 처리효율을 보여주었다. 본 연구결과 HVC 공정은 화학약품 사용량의 절감 및 이에 따른 화학슬러지 발생량의 감소를 기대 할 수 있는 친환경기술로 유지관리비를 최소화할 수 있는 장점이 있었다. 않은 사람들 중 미래의 검진실행의지에 건강소식지가 영향을 미친 경우는 48.7%였다. 보건교육을 받은 후 유방암 자가검진 실천율은 사업군에서 53.9%로 받기 전의 27.3%보다 증가하였으나 대조군의 경우는 별 차이가 없었다. 연령별로는 60대가 가장 높았고 사업군에서 검진율의 증가분은 30대가 가장 컸다. 교육수준별로는 사업군은 고졸이, 대조군은 전문대졸이 가장 높았고 사업군에서 검진율의 증가분은 고졸에서 가장 컸다. 보건교육 후 유방암과 관련된 건강지식의 정도는 사업군이 3.7점으로 대조군보다 유의하게 높았으며, 유방암 자가검진법을 실천하는 사람들의 동기는 ‘일반 대중매체의 영향’이 가장 많았으며 건강소식지가 동기인 경우도 20.4%였다. 사업군에서 건강소식지가 유방암 자가검진법 실천에 영향을 미친 경우가 79.6%였으며 유방암 자가검진법에 관한 보건교육을 받고 실천하지 않은 사람들 중 미래의 실천의지에 건강소식지가 영향을 미친 경우는 43.6%였다. 이상의 소견에서 지역주민을 대상으로 인쇄매체를 통한 보건교육은 인쇄물만으로도 쉽게 실천 할 수 있는 유방암 자가검진법이 가장 효과적이었으며, 자궁암검진에 관해서도 검진을 받을 수 있도록 지역사회의 보건의료의 하부구조를 정비하여 제도적 장치를 마련하고 정보를 제공한다면 자궁암검진 실천율도 증가할 것이다.고 12.9% 의 발달율을 보여 유의적인 차이를 보이지 않았다. 이상의 결과로 보아 핵이식 수정란을 효율적으로 생산하기 위하여

  • PDF