• Title/Summary/Keyword: 검출기 조합

Search Result 80, Processing Time 0.025 seconds

A study on the metamictization and color change in zircon by spectroscopic analysis (분광분석을 통한 지르콘의 메타믹상태와 색상 변화 분석)

  • Kim, Seong-Ki;Ahn, Yong-Kil;Seo, Jin-Gyo;Kim, Jong-Gun;Park, Jong-Wan
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.20 no.1
    • /
    • pp.12-20
    • /
    • 2010
  • Metamictization and color change in zircons from Cambodia and Tanzania were investigated. Elements analysis to detect radioactivity of elements such as U and Th, and spectroscopic analysis using UV-VIS and Fourier transform infrared spectroscopy were performed. According to the UV-VIS spectroscopic analysis, it was perceived that many and high intense absorption peaks appeared in blue and colorless zircons, while less and low intense absorption peaks appeared in uranium contained green and yellow zircons. It was found that those stones have made progress to the metamictization. After heat treatment, we could detect opposite results. As the results of FTIR spectroscopy analysis, in the metamict green and yellow zircon, it is showed that 3-phonon combination mode bands of $[SiO_4]^{4-}$ internal vibration in the region of 3100~3400 $cm^{-1}$ are broad and some of them disappear. However, the disappeared bands are observed again due to restored crystal lattice by the heat treatment. Also, $U^{4+}$ peaks that can detect the uranium content in zircon appears at near 4800 $cm^{-1}$ in the green and yellow samples. From this investigation, we could observe the metamictization effect and color change in uranium-bearing zircon by heat treatment using spectroscopic analysis.

Clinicoradiological Features of Pulmonary Cryptococcosis in Immunocompetent Patients (정상 면역 환자에서 폐 크립토코쿠스증의 임상방사선학적 특징)

  • Hong Seok Choi;Yun-Hyeon Kim;Won Gi Jeong;Jong Eun Lee;Hye Mi Park
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.253-262
    • /
    • 2023
  • Purpose To assess the clinicoradiological features of pulmonary cryptococcosis in immunocompetent patients. Materials and Methods This retrospective study included immunocompetent patients who had been diagnosed with pulmonary cryptococcosis on the histopathologic exam and underwent chest CT between January 2008 and November 2019. Imaging features were divided into major imaging patterns, distributions, and ancillary imaging findings. Univariable analysis was performed to evaluate clinicoradiological features according to the presence of serum cryptococcal antigen. Results Thirty-one patients were evaluated (mean age: 60 years, range: 19-78 years). A single nodular lesion confined to a single lobe was the most common imaging pattern (14/31, 45.2%). Serum cryptococcal antigen tests were performed in 19 patients (19/31, 61.3%). The presence of serum cryptococcal antigen was observed in six patients (6/19, 31.6%), all of whom showed a consolidation-dominant pattern. The presence of serum cryptococcal antigen was significantly associated with the consolidationdominant pattern compared to those associated with a nodule-dominant pattern (p = 0.011). Conclusion A combination of CT findings of consolidation and a positive serum cryptococcal antigen test may be helpful for diagnosing pulmonary cryptococcosis in immunocompetent patients.

Establishment of the Monoenergetic Fluorescent X-ray Radiation Fields (교정용 단일에너지 형광 X-선장의 제작)

  • Kim, Jang-Lyul;Kim, Bong-Hwan;Chang, Si-Young;Lee, Jae-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.1
    • /
    • pp.33-47
    • /
    • 1998
  • Using a combination of an X-ray generator Installed in radiation calibration laboratory of Korea Atomic Energy Research Institute (KAERI) and a series of 8 radiators and filters described in ISO-4037, monoenergetic fluorescent X-rays from 8.6 keV to 75 keV were produced. This fluorescent X-rays generated by primary X-rays from radiator were discriminated $K_{\beta}$ lines with the aid of filter material and the only $K_{\alpha}$ X-rays were analyzed with the high purity Ge detector and portable MCA. The air kerma rates were measured with the 35 co ionization chamber and compared with the calculational results, and the beam uniformity and the scattered effects of radiation fields were also measured. The beam purities were more than 90 % for the energy range of 8.6 keV to 75 keV and the air kerma rates were from 1.91 mGy/h (radiator : Au, filter : W) to 54.2 mGy (radiator : Mo, filter : Zr) at 43 cm from center of the radiator. The effective area of beam at the measurement point of air kerma rates was 12 cm ${\times}$ 12 cm and the influence of scattered radiation was less than 3 %. The fluorescent X-rays established in this study could be used for the determination of energy response of the radiation measurement devices and the personal dosemeters in low photon energy regions.

  • PDF

Image Based Damage Detection Method for Composite Panel With Guided Elastic Wave Technique Part I. Damage Localization Algorithm (복합재 패널에서 유도 탄성파를 이용한 이미지 기반 손상탐지 기법 개발 Part I. 손상위치 탐지 알고리즘)

  • Kim, Changsik;Jeon, Yongun;Park, Jungsun;Cho, Jin Yeon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.1
    • /
    • pp.1-12
    • /
    • 2021
  • In this paper, a new algorithm is proposed to estimate the damage location in the composite panel by extracting the elastic wave signal reflected from the damaged area. The guided elastic wave is generated by a piezoelectric actuator and sensed by a piezoelectric sensor. The proposed algorithm adopts a diagnostic approach. It compares the non-damaged signal with the damaged signal, and extract damage information along with sensor network and lamb wave group velocity estimated by signal correlation. However, it is difficult to clearly distinguish the damage location due to the nonlinear properties of lamb wave and complex information composed of various signals. To overcome this difficulty, the cumulative summation feature vector algorithm(CSFV) and a visualization technique are newly proposed in this paper. CSFV algorithm finds the center position of the damage by converting the signals reflected from the damage to the area of distance at which signals reach, and visualization technique is applied that expresses feature vectors by multiplying damage indexes. Experiments are performed for a composite panel and comparative study with the existing algorithms is carried out. From the results, it is confirmed that the damage location can be detected by the proposed algorithm with more reliable accuracy.

Study on the Safety of Firefly Luciferase in Human as a Transient Reporter Gene of Oncolytic Virotherapy (항암 바이러스 치료제의 보고유전자로써 반딧불이 루시퍼레이즈의 인체 내 안전성에 대한 연구)

  • Hong, Young Mi;Yoon, Woong Hee;Lee, You Ra;Kim, Soo Ji;Ngabire, Daniel;Narayanasamy, Badrinath;Ornella, Mefotse Saha Cyrelle;Kim, Myunghee;Cho, Euna;Lee, Bora;Hwang, Tae-Ho
    • Journal of Life Science
    • /
    • v.31 no.11
    • /
    • pp.1028-1036
    • /
    • 2021
  • Firefly luciferase (FLuc) can function as an efficient marker in the gene and viral therapies. Nonetheless, its clinical translation has been unaccomplished with the concerns on its exogenous nature and the similarity with human fatty acyl-CoA synthetase. In this study, we aimed to show safety of FLuc by conducting a set of preclinical experiments and a human use. Initially, FLuc permeability across the plasma membrane was investigated by delivering the FLuc-carrying viral vector, OTS-412, or the FLuc recombinant protein. After in vitro infection of OTS-412 into different cancer cell lines, FLuc activity was detected only in the cell lysates, but not in culture media. In addition, recombinant FLuc protein further showed the impermeability against the plasma membrane. Similar result was also observed in the in vivo experiment. After being injected into the VX2 tumor-bearing rabbit, the FLuc exclusively resided within the tumor tissue without being detected in the blood plasma or other organs. Human cancer cell lines originated from various organs were lysed and treated to the FLuc, and none of the human substrates was reactive against the FLuc. As a final step, FLuc recombinant protein was intravenously injected into a human. The luciferase was degraded with the half-life of 20 to 30 minutes in blood, and was untraceable from 1.5 hr after the injection. In addition, the blood plasma was nonresponsive against the fatty acids. Hematological analysis was also comparable between the pre- and post-injection. Altogether, our study collectively demonstrates the safety of the firefly luciferase.

Use of Auxins for Rhizome Propagation and Shading Effect on Growth of Asarum sieboldii Mio. (세신(細辛)의 근경삽(根莖揷)번식에 있어서 오옥신의 이용과 차광재배(遮光栽培))

  • Kim, Sun-Gon;Park, Chung-Heon;Choi, Dong-Geun;Hwang, Chang-Ju;Chin, Seong-Kye
    • Korean Journal of Medicinal Crop Science
    • /
    • v.2 no.3
    • /
    • pp.198-204
    • /
    • 1994
  • This study was carried out to investigate the auxin(IAA, IBA, NAA) treatment and the effect of shading rate in Asarum sieboldii. The results obtained were summerized as follows: By the soaking treatment of auxins to the cutted rhizome enhanced root growth and plant weight. By the increment of shading rate, plant growth was much better compare to the control. Leaf fallen times appeared about 20 days more earlier at plain area then the alpain area. Root yield was much higher by the treatment of shading then the conventional cultivation so it seem to be the useful for large scale cultivations of A. sieboldii.

  • PDF

Evaluation of Image Quality & Absorbed Dose using MCNPX Simulation in the Digital Radiography System (디지털방사선영상시스템에서 MCNPX 시뮬레이션을 이용한 영상 품질 및 선량평가)

  • An, Hyeon;Lee, Dongyeon;Ko, Sungjin;Kim, Changsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.327-335
    • /
    • 2016
  • The study is enforce to study image quality evaluation of condition provide the IEC and combination of clinical conditions each quality of radiation that image quality to assess the conditions provided to IEC in the clinical environment to conduct image quality assessment of the digital radiography system in the detector have environmental limits. First, image quality evaluation was evaluated by measuring the MTF, NPS using four quality of radiation and Using MCNPX simulation lastly DQE make a image quality evaluation after calculating the particle fluence to analyze spectrum quality of radiation. Second, Using MCNPX simulation of four quality of radiation was evaluated absorbed dose rate about electronic 1 per unit air, water, muscle, bone by using Radiation flux density and energy, mass-energy absorption coefficient of matter. Results of evaluation of image quality, MTF of four quality of radiation was satisfied diagnosis frequency domain 1.0 ~ 3.0 lp/mm of general X-ray that indicated 1.13 ~ 2.91 lp/mm spatial frequency. The NPS has added filter, spatial frequency 0.5 lp/mm at standard NPS showed a tendency to decrease after increase. Unused added filter, spatial frequency 0.5 lp/mm at standard NPS showed a certain NPS result value after decrease. DQE in 70 kVp / unuesd added filter(21 mm Al) / SID 150 cm that patial frequency 1.5 lp/mm at standard showed a tendency to decrease after certain value showed. Patial frequency in the rest quality of radiation was showed a tendency to decrease after increase. Results of evaluation of absorbed dose, air < water < muscle < bone in the order showed a tendency to increase. Based on the results of this study provide to basic data that present for the image quality evaluation method of a digital radiation imaging system in various the clinical condition.

Effects of Field Configuration Shielding Area and Changing of Density and Sensitivity on Tube Current and Image Quality in Automatic Exposure Control System (자동노출제어장치의 채광창 차폐정도와 농도, 감도의 변화가 관전류량과 영상품질에 미치는 영향)

  • Jeong, Min-Gyu;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.635-642
    • /
    • 2020
  • The purpose of this study was to analysis the effects of shielding area of field configuration with changing of sensitivity and density on tube current (milliampere-seconds, mAs) and image quality in automatic exposure control (AEC) system. The equipment used a digital radiography device (Digital Diagnost, Philips, Netherlands), which has a integral type with an X-ray tube and an indirect digital detector. The AEC system conditions were consisted of 9 setting environments, that mode changing of the sensitivity (S200, S400, S800) and the density (+2.5, 0, -2.5). The tube current evaluated automatically exposed mAs under 81 combination conditions crossed by AEC conditions in fixed at 40 kVp. The image quality evaluated the radiographic images that selected valid images by visual assessment the radiographic images of the self-produced conical pyramid phantom and then measured their signal to noise ratio (SNR). As a result, the maximum tube current was 60.0 mAs that automatically exposed conditions were the 100% of shielding area and the sensitivity of S200 and the density of +2.5. The minimum tube current was 0.9 mAs with non-shielding area and the sensitivity of S800 and the density of -2.5. When the shielded area 0% with the sensitivity of S200 and the density of +2.5, the maximum SNR was the highest as 25.2. But when the shielded area 25% with the sensitivity of S800 and the density of -2.5, the minimum SNR was the lowest as 4.7.

Element Dispersion and Wallrock Alteration Analysis Using Portable XRF and SWIR in the Samgwang Au Deposit (휴대용 XRF와 단파장적외선 분광분석을 이용한 삼광 금광상의 원소분산 및 모암변질 분석)

  • Kim, Junkyum;Shin, Dongbok;Yoo, Bongchul;Im, Heonkyung;Kim, Ilkyu
    • Economic and Environmental Geology
    • /
    • v.52 no.4
    • /
    • pp.259-274
    • /
    • 2019
  • Using portable XRF and SWIR analyzer, the characteristics of element dispersion and wallrock alterations induced by interaction between hydrothermal fluids and host rocks were investigated and ore exploration factors were estimated for the orogenic-type Samgwang Au deposits. On this purpose, in-situ measurements were conducted for 804 spots at regular intervals with a total of 4,824 times for host rocks, consisting of schist and gneiss, and altered wallrocks contacted with quartz veins in the Bonhang adit of the deposit, and the results were compared with quantitative data obtained by XRF and ICP analysis. The regression coefficients are 0.88 for major elements and 0.56 for trace elements, excluding V. For polished rock slabs, better results came out for major elements, 0.97 and for trace elements, 0.65. In altered wallrocks contacted with quartz veins, elements such as Fe, Zn, and Rb exhibit positive correlations with As in concentrations, while V forms a negative trend. Contour maps demonstrate that As, Zn, Rb, Fe, Ti, Cr, and Ni are enriched together near quartz veins, showing similar elemental behaviors. In-situ analysis using portable SWIR analyzer represents that schist and gneiss contain mica, illite, chlorite, sericite, amphibole, and epidote, while illite, sericite, gypsum, and mica are present in the altered rocks contacted with quartz veins. In contour maps, chlorite occurs mostly in host rocks, while sericite is concentrated near quartz veins. These results are similar to those of previous studies for element dispersion and hydrothermal alteration, and support the possibility for application of in-situ analysis on the exploration of orogenic gold deposit.

Studies on Selenium-fortified Functional Hanwoo-Beef by Utilizing Spent Mushroom Composts I. Studies on the Manufacture of Fermented Feeds by Using Spent Mushroom Composts and Fortification of Organic Selenium (버섯폐배지를 이용한 셀레늄강화 기능성 한우고기 생산에 관한 연구 I. 버섯폐배지 이용 발효사료제조와 유기셀레늄 강화에 관한 연구)

  • Lee, Jang-Hyung;Kim, Wan-Young
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.6 no.1
    • /
    • pp.102-115
    • /
    • 2004
  • Main objectives of this study were to increase digestibilities of indigestible ingredients in spent mushroom composts (SMC) consisted of sawdust mainly as well as to fortify conversion of inorganic Se present in SMC to organic Se via fermentable microbial actions. Experimental feeds were designed to contain the increasing level of selenium (0.06ppm, 0.54ppm, 1.26ppm and 1.86ppm) in combination with SMCs of Se-enriched and non-Se mushrooms. Feeds were also fermented using commercial microbial feed additives (Sambae, Ltd., Korea) comprised Saccharomyces, Bacillus, Aspergillus, Streptococcus and Actinomycetes before feeding trial for Hanwoo (Korean native cattle). Those were fermented for 0, 12, 24, and 48 hrs. Initial pH was linearly increased as Se concentration increases or the proportion of SMC of Se-enriched mushroom increased (p<0.0001). pH values of fermented feeds (0.54ppm, 1.26ppm and 1.86ppm) containing SMC of Se-enriched mushroom were not different since 12 hrs of fermentation time and their pH was significantly lowered compared to control group. The increasing level of Se concentration in fermented feeds showed significant differences in organic and inorganic Se contents and proportion of organic Se among treatments. As a SMC proportion of Se-enriched mushrooms in the fermented feed was increased, organic Se proportion was significantly decreased (p<0.0001). The control treatment (0.06ppm) comprising the non-Se SMC only was estimated of the organic Se to be 100% and the treatment groups containing the increasing level of Se were estimated of organic Se to be approximately 70%.