• Title/Summary/Keyword: 검체

Search Result 651, Processing Time 0.025 seconds

Monitoring of Pulmonary Tuberculosis by Polymerase Chain Reaction After Antituberculous Treatment (항결핵제 투여후 중합효소연쇄반응으로 추적한 폐결핵 환자들의 치료반응 관찰)

  • Jeon, Chang-Ho;Suh, Hun-Suk;Lee, Sang-Chae;Hyun, Dae-Sung;Ahn, Wook-Su
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.5
    • /
    • pp.935-941
    • /
    • 1998
  • Background: As living and dead Mycobacteria could be amplified by polymerase chain reaction(PCR), it was considered that PCR was inappropriate for the monitoring of pulmonary tuberculosis after treatment. But we found negative conversion of PCR after successful treatment. We would like to know about the negative conversion rate of PCR and its conversion time after antituberculous treatment. Methods: We collected 113 sputums from the 16 patients of pulmonary tuberculsosis visiting Catholic University Hospital of Taegu Hyosung. We consecutively tested AFB smear, AFB culture and PCR by 2 to 4 weeks after antituberculous therapy. The patients were classified according to the chest X ray findings. Results: We detected negative conversion of PCR from all 16 patients of the pulmonary tuberculosis within 30 weeks after treatment. The average negative conversion time was $16{\pm}8$ weeks. The conversion time according to the chest X -ray findings were as follows : For the 8 cases of minimum were $9{\pm}5$ weeks, 4 cases of modreate advanced were $20{\pm}8$ weeks, and 4 cases of far advanced were $23{\pm}2$ weeks. The product of PCR was gradually decreased according to the duration of treatment. Conclusions: From the results of our study, we could utilize M. tubercuosis PCR for the prediction of therapy response and monitoring of the patient with pulmonary tuberculosis after treatment.

  • PDF

Transthoracic Fine Needle Aspiration Biopsy in Localized Pulmonary Lesions: Diagnostic Accuracy and Complications (국소적 흉부 병변에서 세침 흡입 생검의 진단 성적 및 합병증)

  • Yang, Suck-Chul;Kim, Yeon-Soo;Kim, Soon-Kil;Kim, Tae-Wha;Lee, Kyung-Sang;Yoon, Ho-Joo;Shin, Dong-Ho;Park, Sung-Soo;Lee, Jung-Hee;Jeon, Seok-Chol;Lee, Jung-Dal
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.5
    • /
    • pp.685-694
    • /
    • 1995
  • Introduction: Transthoracic fine needle aspiration biopsy(TNAB) has shown to be a resonably safe, simple, and accurate procedure in diagnosis of intrathoracic lung lesions. We reviewed the results of 1,005 TNAB of chest lesions performed on 930 patients with 20 or 22-gauze needles over a period of 10 years. Methods: From November 1983 to June 1995, 1,005 cases in 930 patients with an undiagnosed lung lesion underwent TNAB at the Hanyang University Hospital: 66% were men and 34% were women. Most of the patients were 40~60 years old and the youngest patient was 3 years of age. Result: 540 patients had various malignant chest lesions and 322 patients had benign pulmonary lesions. The diagnostic accuracy of TNAB was 96.1 percent in malignant diseases with one false positive result and 90.1% in benign diseases. A definitive diagnosis was not obtained in the remaining 68 patients. The most common diagnoses among 519 malignancy chest lesions with TNAB were the following: squamous cell lung carcinoma, 31.7%; adenocarcinoma, 24.7%; small cell lung carcinoma, 16.7%; metastatic cancer, 14.2%; large cell lung carcinoma, 6.2% and so on. Complications included pneumothorax in 12.3% necessitating chest tube drainage in 0.6%. Minor hemoptysis occurred in 3.6%. There was no death directly attributable to the procedure. Conclusion: We concluded that TNAB permits a direct approach to all kinds of localized lung lesions with a high degree of accuracy and without major complications.

  • PDF

A Study on Heavy Metal Contents in Processed Foods and Their Safety Evaluations (가공식품 중 중금속 함량 및 안전성 평가)

  • Lee, Hyo-Jung;Shim, Jee-Youn;Oh, Hyun-Suk;Jang, Mi-Ran;Lee, Yoon-Ae;Lee, Ryun-Kyung;Kim, Min-A;Lee, Sang-Min;Cho, Tae-Yong;Kang, Ho-Il
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.1
    • /
    • pp.21-27
    • /
    • 2012
  • This research was carried out as a survey on the contents of lead, cadmium, and arsenic in processed foods (milk, vegetable oil, and margarine) in Korea. The limits of quantification (LOQs) were Pb 0.3 ${\mu}g/kg$, Cd 0.15 ${\mu}g/kg$, and As 0.45 ${\mu}g/kg$ for milk and Pb 0.61 ${\mu}g/kg$, Cd 0.31 ${\mu}g/kg$, and As 0.91 ${\mu}g/kg$ for vegetable oil and margarine. The recoveries were 92.6-98.0% for Pb, 91.2-98.9% for Cd, and 97.9-104.7% for As. The average levels of Pb were 2.395 ${\mu}g/kg$ for milk, and 7.656 ${\mu}g/kg$ for vegetable oil. The average levels of Cd were 0.483 ${\mu}g/kg$ for milk, and 0.380 ${\mu}g/kg$ for vegetable oil, and levels of As were 0.781 ${\mu}g/kg$ for milk, and 1.241 ${\mu}g/kg$ for vegetable oil. The results of this study showed that Pb, Cd, and As contents in the whole samples were less than the maximum residual levels in the processed foods that were specified by the Codex standard.

Detection of Lamivudine-Resistant Mutations of HBV DNA Polymerase Gene Using PCR-Direct Sequencing

  • Lee, Kyung-Ok;Lee, Hye-Jung;Byun, Ji-Young;Lee, Sung-Yeun;Kim, Jeong-Sook;Jung, Na-Young;Chung, Soo-Jin;Seong, Hye-Soon;Kim, Kyung-Tae
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.38 no.3
    • /
    • pp.196-202
    • /
    • 2006
  • Treatment of hepatitis B virus (HBV) with lamivudine is effective in suppressing virus replication and results in reduced inflammatory activity. However the most troublesome problem of lamivudine treatment is the emergence of lamivudine-resistant strains with amino acid substitution in the YMDD motif of DNA polymerase gene during the treatment. The aim of this study was to determine the mutation of YMDD motif (codon 552) and codon 528 in chronic HBV patients with lamivudine therapy using PCR-direct sequencing and to investigate the relationship between lamivudine mediated HBV mutation and HBeAg. HBV DNA was extracted from serum samples of HBV patients and amplified by nested PCR with two sets of primer pairs selected in HBV DNA polymerase gene. Amplified PCR product was analyzed by 2% agarose gel electrophoresis and direct sequencing. HBV mutation was detected in 124 out of 207 samples (60%). Single mutation was 50.8% for M552I, 43.5% for M552V, 5.7% for M552I/V and the L528M mutation was 67.0%. Double mutation was 43.6% for M552V/L528M, 33.1% for M552I/L528(wild type), 17.7% for M552I/L528M and 5.6% for M552I/V/L528M. Serine mutation at YMDD motif (M552S) was not found and the L528M mutation frequently accompanied M552V type. In this study, the typical difference of frequencies for HBV mutation depending on HBeAg was not found. Moreover, the PCR-direct sequencing method used in this study might be a powerful tool for the mutation study in clinical reference laboratories with high volume.

  • PDF

Diagnosis of Enteropathogens in Children with Acute Gastroenteritis: One Year Prospective Study in a Single Hospital (소아의 급성 위장관염의 원인균 진단: 단일 병원에서 1년간의 전향적 연구)

  • Chang, Ju Young;Choi, Ji Eun;Shin, Sue;Yoon, Jong Hyun
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.9 no.1
    • /
    • pp.1-13
    • /
    • 2006
  • Purpose: Acute gastroenteritis in children is one of the frequently encountered diseases with relatively high admission rate. The aim of this study is to determine the isolation trends of common and emerging pathogens in acute gastroenteritis in children over a 12-month period in a community hospital. Methods: The study group included the children who were hospitalized to Seoul National University Boramae Hospital from April, 2003 to March, 2004 or visited outpatient clinic from April, 2003 to July, 2003 with presenting features of acute gastroenteritis. Stool specimens were obtained within 2 days after the visit and examined for the following pathogens: rotavirus, adenovirus, Salmonella, Shigella, Vibrio, pathogenic Escherichia coli (E.coli), Campylobacter and Yersinia species. Viral study was done with commercial kits for antigen detection. Identification of the bacterial pathogens was done by culture using selective media. For pathogenic E.coli, polymerase chain reaction (PCR) was done with the target genes related to the pathogenecity of enterotoxigenic E.coli (ETEC), enteropathogenic E.coli (EPEC) and enterohemorrhagic E.coli (EHEC). Results: The 130 hospitalized children and 28 outpatients were included in this study. The majority of children (>93%) were less than 6 years. Pathogens were isolated in 47% of inpatients and 43% of outpatients, respectively. Rotavirus was the most frequently identified pathogen, accounting for 42.3% of inpatients and 29.6% of outpatients. Nontyphoidal salmonella is the most commonly isolated bacterial pathogen (3.9%) in hospitalized children. Pathogenic E.coli (EPEC, ETEC) was detected in 2.1% (2/97) of inpatients and 25% (3/12) of outpatients. EHEC, adenovirus, Campylobacter, Yersinia and Shigella species were not detected in this study. Conclusion: Rotavirus is the most common enteropathogen in children with acute gastroenteritis. Nontyphoidal salmonella and pathogenic E.coli are important bacterial pathogens. Campylobacter species may not be commonly detected organism in hospitalized children with acute diarrhea.

  • PDF

Clinical Usefulness of Serum Uric Acid in Gastroenteritis Patients with lJehydration (급성장염으로 인한 탈수 환아에서 혈청 요산의 염상적 유용성)

  • Song, Jun Ho;Jang, Myung Wan;Yoo, Hwang Jae;Kim, Cheol Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.9 no.1
    • /
    • pp.23-30
    • /
    • 2006
  • Purpose: The estimation of fluid deficit is crucial to the proper management of dehydrated children. Without well-documented serial weights on the same scale, the estimation of any given child's fluid deficit is imprecise and dependent largely on subjective clinical criteria. Despite the abundance of literature on clinical and laboratory evaluation of dehydration, few studies have focused on serum uric acid. So, we examined the usefulness of scrum uric acid in gastroenteritis patients with dehydration. Methods: Medical records of 90 gastroenteritis patients were retrospectively reviewed. By the body weight loss, we classified patients with mild, moderate, and severe dehydration groups. We studied the relevance of laboratory data (BUN, creatinine, serum bicarbonate, glucose, urine specific gravity, and uric acid) with dehydration. Results: 54 children (60%) were dehydrated mildly, 24 (26%) dehydrated and moderately, and 12 (14%) dehydrated severely. Statistically significant differences in BUN, creatinine, serum bicarbonate, glucose, and urine specific gravity could not be observed. But there was significant relationship between uric acid and the degree of dehydration. Data analysis suggested that the level of 7.0 mg/dL is the best cut-off value for predicting the development of moderate or severe dehydration. At this cut-off value, the sensitivity and specificity were 66.6% and 87.1%. Conclusion: Our study supports that the measurement of serum uric acid with traditional scale is useful for predicting the development of dehydration. But, in order 10 be used as the indicator for proper treatment at an earlier stage, further validation about serum uric acid is necessary.

  • PDF

Decrease of Aflatoxin M1 Level in Raw Cow’s Milk using the Hazard Analysis and Critical Control Points (HACCP) System (HACCP 제도에 의한 우유의 아플라톡신 M1의 저감화)

  • Kim, Ki-Hwan;Nam, Myoung Soo
    • Journal of Life Science
    • /
    • v.26 no.2
    • /
    • pp.190-197
    • /
    • 2016
  • Aflatoxin M1 can be produced in cow’s milk when cows eat contaminated produce. Milk is a major source of food for infants and for children who have a weak level of immunity, and the detection of Aflatoxin M1 for risk assessment is necessary in order to reduce the amount of it in milk. In this study, the Aflatoxin M1 level was monitored for one year in raw milk samples obtained from Chungnam Province, Korea. The milk samples were divided into three categories: 1. milk samples from a standard general farm, 2. milk samples from a HACCP controlled farm, and 3. milk samples from the supply of Aflatoxin M1 reduced fodder. The average concentrations of Aflatoxin M1 in milk were 0.023±0.005 ug/l for the standard general farm, 0.017±0.004 ug/l for the HACCP controlled farm, and 0.013±0.003 ug/l for the supply of Aflatoxin M1 reduction fodder. Milk collected from the supply of Aflatoxin M1 reduction fodder had the lowest level of Aflatoxin M1. However, when efficiency and economic aspects are considered the most effective way of reducting Aflatoxin M1, could be taking milk from the HACCP controlled farm and implementing good feed management. Institutional support from the government, careful management of dairy farming, and a strict farm sanitation program are required in order to lower the level of Aflatoxin M1 in milk.

Quality Assessment and Comparison of Several Radioimmunoassay Kits and Chemiluminescence Immunoassay Methods for Evaluating Serum Estradiol (혈중 Estradiol 농도 측정을 위한 여러 방사면역측정 검사키트 및 화학면역발광 검사법의 성능평가 및 상호비교)

  • Choi, Sung Hee;Noh, Gyeong Woon;Kim, Jin Eui;Song, Yoo Sung;Paeng, Jin Chul;Kang, Keon Wook;Lee, Dong Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.72-80
    • /
    • 2015
  • Purpose Serum estradiol ($E_2$) measurement is requested for diagnosing menstrual cycles, ovulation induction, infertility, and menopause. $E_2$ is measured using several methods and kits including radioimmunoassay (RIA) and chemiluminescece immunoassay (CLIA). The purpose of this study was to evaluate quality of these methods and to compare them with each other. Materials and Methods Seven radioimmunoassay kits and two CLIA methods were included in the analysis. Using standard samples and patient samples, intra-assay precision, inter-assay precision, correlation between other methods, sensitivity, and recovery rate were evaluated. Results For all tested kits and methods, coefficients of variance (CVs) of intra-assay precision test were 10.9~13.6% in low-level samples and less than 10% in medium and high-level samples. CVs of inter-assay precision test were 10.8~12.3% in low-level samples and less than 10% in medium and high-level samples with all tested kits and methods. Recovery rates were $92.7{\pm}12.4%$ for SIEMENS, $101.4{\pm}18.4%$ for DIAsource, $95.1{\pm}11.5%$ for AMP, $108.4{\pm}18.5%$ for BECKMAN COULTER, $104.2{\pm}13.5%$ for BECKMAN COULTER Ultra Sensitive, $101.3{\pm}11.6%$ for CIS Bio, and $93.1{\pm}13.2%$ for MP kits. Sensitivity was 7.5, 6.2, 5.7, 6.2, 5.3, 4.5, and 5.5 pg/mL for SIEMENS, DIAsource, AMP, BECKMAN COULTER, BECKMAN COULTER Ultra Sensitive, CIS Bio, and MP kits, respectively. The measurement by MP kit was slightly higher than those by other kits in low-level samples, and the measurement by E170 was slightly higher than those of other kits in medium and high-level samples. In the measurement of standard sample for external quality control, SIEMENS kit produced relatively lower values whereas E170, Architect, and MP kits produced relatively higher values compared with other kits. Conclusion All tested kits for $E_2$ measurement have satisfactory performance for clinical use. However, correlation between kits should be considered when test kits are to be changed, because some pairs of kits do not have correlations with each other.

  • PDF

Efficient Application of Westgard Multi-Rules and Quality Control Implementation Improvement (Westgard Multi-Rules의 효율적 적용과 조치사항의 개선)

  • Jung, Heung Soo;Oh, Youn Jung;Bae, Jin Soo;Baek, Jin Young;Hwang, Bo ra;Shin, Yong Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.60-64
    • /
    • 2017
  • Purpose Westgard multi-rules application based on test quality improvement and commercialized international standard has been widely used in quality control. However, it is difficult to applicate the Westgard multi-rules in nuclear medicine in vitro tests due to the larger sample sizes and the simultaneous measurement of quality control material and patient sample. This study investigated the usefulness of Westgard multi-rules application in nuclear medicine in vitro tests. Materials and Methods A total of 282 systematic error multi-rules (22s, 101s) recorded in the samsung medical center computer system from January 2013 to June 2016 along with 117 cases of corrective measure record was analyzed. The Quality control implementation is recorded in Hospital information system were divided into 4 high-level areas including quality control material error, experimental procedural error, Kit lot number management error, and others. To prevent quality control material error, the existing method that each staff used their own method was changed. The staff who in charge of managing the quality control material was designated and daily consumption amount of every test was strictly controlled by one person. To prevent other errors, every test step was standardized so that the entire test procedures are identically implemented. Results The total quality control implementation was 117 cases; As a result, 62 quality control material errors were 62 cases, experimental process errors were 24 cases, Kit lot number control errors were 18 cases, and other errors were 13 cases. The quality control material error was corrected and could be used fresh materials within 2 days after thawing. The cases of systemic error were decreased to causes as quality control material error. The quality control materials were reduced above 10 vials to a monthly average. In addition, these errors of experimental processing and Kit lot number were improved by test standardization. Consequently, the cases of 101s and 22s in systematic error rules decreased at least 2 cases to a monthly average. Conclusion To confirm of systematic error through multi-rules application quickly, it is necessary to base on management of the QC material, target values and standard deviation. Moreover, in the event of a systematic error, it was found important to record measures based on test cause analysis. The experiment results are expected to contribute to internal quality control improvement and prompt and accurate result reporting through error recording and causal analysis based on Westgard multi-rules analysis.

  • PDF

Comparative Evaluation of 25-OH-VitD and 25-OH-VitD3 by Radioimmunoassay (방사면역 측정법에 의한 25-OH-VitD와 25-OH-VitD3의 비교 평가)

  • Lee, Young-ji;Park, Ji-hye;Lim, Soo-yeon;Cheon, Jun-hong;Lee, Sun-ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.24 no.1
    • /
    • pp.33-38
    • /
    • 2020
  • Purpose Vitamin D is essential for maintaining bone health, controling cell proliferation or differentiation, strengthening immune function by controlling calcium metabolism in the body. Vitamin D deficiency can lead to increase the risk of rickets, osteoporosis, cardiovascular disease, diabetes and cancer. Especially, South Korea is one of the highest population proportion of vitamin D deficiency. Accurate determination of levels of 25-OH-VitD or 25-OH-VitD3 in blood serum is required for the diagnosis and treatment of vitamin D deficiency. In this study, radioimmunoassay of 25-OH-VitD and 25-OH-VitD3 was performed and compared to evaluate the effectiveness of Vitamin D radioimmunoassay. Materials and Methods Serum 25-OH-VitD and 25-OH-VitD3 levels were measured using radioimmunoassay. The interrelationship, reproducibility and population distribution rate were evaluated. In addition, the internal quality control was performed at Asan Medical Center from April 2017 to June 2019 and the result of external quality control (Interagency proficiency evaluation) of first and second half of 2018 hosted by the Korean Society of Nuclear Medicine Technology (KSNMT). Both tests were measured by same manufacturer's reagent. Results 25-OH-VitD showed a strong positive correlation on 97 samples, as 25-OH-VitD3 x 0.9 + 0.3 (R>0.9). In repeated measurement, the average Diff(%) value of the reproducibility evaluation of 25-OH-VitD and 25-OH-VitD3 were 7.7% and 7.4%, respectively. Population distribution results showed no statistically significant differences(p>0.05). The resultant value of internal quality control, which measured from April, 2017 to June 2019 in Blood test room of Nuclear Medicine at Asan Medical Center, showed average (CV%) 6.2% and 6.8%, respectively. As a result of the external quality control (interagency proficiency evaluation) Z value obtained under 2.0, as shown below; Conclusion The interrelationship, reproducibility, population distribution rate, internal quality control and external quality control between 25-OH-VitD and 25-OH-VitD3 radioimmunoassay shows superior outcome. Radioimmunoassay, which can be alone measured in the blood as 25-OH-VitD or 25-OH-VitD3, is considered suitable screening tests for the diagnosis of vitamin D deficiency.